RKRandell Kruger

Randell Kruger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Randell Kruger has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effective Dose Assessment for Participants in the National Lung Screening Trial Undergoing Posteroanterior Chest Radiographic Examinations

    by Randell Kruger, Michael J. Flynn, Phillip F. Judy, Christopher H. Cagnon, J. Anthony Seibert

    OBJECTIVE. The National Lung Screening Trial (NLST) is a multicenter randomized controlled trial comparing low-dose helical CT with chest radiography in the screening of older current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004, when 53,454 participants had been randomized at 33 screening sites. The objective of this study was to determine the effective radiation dose associated with individual chest radiographic screening examinations. SUBJECTS AND METHODS. A total of 73,733 chest radiographic examinations were performed with 92 chest imaging systems. The entrance skin air kerma (ESAK) of participants' chest radiographic examinations was estimated and used in this analysis. The effective dose per ESAK for each examination was determined with a Monte Carlo–based program. The examination effective dose was calculated as the product of the examination ESAK and the Monte Carlo estimate of the ratio of effective dose per ESAK....


    • 15 July 2003
      • Vol. 28  (14) , 1608-13

    Radiation dose reduction to medical staff during vertebroplasty: a review of techniques and methods to mitigate occupational dose.

    by Randell Kruger, Thomas Faciszewski

    Case crossover design was conducted. The purpose of the current study was to determine the radiation exposure level of operators performing fluoroscopically assisted vertebroplasty and to determine optimal techniques to reduce this exposure. The use of ionizing radiation to provide quality imaging during minimally invasive orthopedic procedures has dramatically increased. One such procedure, vertebroplasty, which is the percutaneous fixation of fractured vertebrae with polymethylmethacrylate, requires the use of ionizing radiation of biplanar fluoroscopy. The adverse effects of excessive radiation exposure to occupational personnel may not be realized for several years. Twelve months of occupational dose data for a single operator were evaluated and correlated to the modifications of practice habits implemented and shielding techniques used to reduce the operator's exposure while maintaining adequate image quality. Before the implementation of radiation-reduction procedures, the average whole-body dose per vertebroplasty procedure was 1.44 mSv/vertebrae, and the measured hand dose was 2.04 mSv/vertebrae. After implementation of radiation-reducing procedures and shielding techniques, the average whole-body dose per vertebroplasty procedure was 0.004 mSv/vertebrae, and the average hand dose was 0.074 mSv/vertebrae. Testing of the shielding device indicated a significant reduction in whole-body and hand doses. For the fluoroscopic modes investigated, the shielding used resulted in reductions ranging from 42.9% to 86.1%. It is critical that operators performing vertebroplasty procedures have a fundamental understanding of radiation physics and radiation protection to minimize radiation exposure.