Richard M. Treger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Richard M. Treger has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Craig L. Anderson
Department of Emergency Medicine, University of California, Irvine, CA, USA
1 shared publicationDalila Corry
David Geffen School of Medicine University of California Los Angeles Los Angeles California
1 shared publicationDavid A. Elashoff
Department of Medicine Statistics Core, University of California, Los Angeles, CA, USA
1 shared publicationNader Kamangar
David Geffen School of Medicine University of California Los Angeles Los Angeles California
1 shared publicationScott E. Rudkin
Department of Emergency Medicine, University of California, Irvine, CA, USA
1 shared publicationShahriar Pirouz
David Geffen School of Medicine University of California Los Angeles Los Angeles California
1 shared publication
Latest Publications
- 7 March 2018
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 35 (5) , 511-518
Assessing Acid–Base Status in Circulatory Failure: Relationship Between Arterial and Peripheral Venous Blood Gas Measurements in Hypovolemic Shock
Background and Objectives: In severe circulatory failure agreement between arterial and mixed venous or central venous values is poor; venous values are more reflective of tissue acid–base imbalance. No prior study has examined the relationship between peripheral venous blood gas (VBG) values and arterial blood gas (ABG) values in hemodynamic compromise. The objective of this study was to examine the correlation between hemodynamic parameters, specifically systolic blood pressure (SBP) and the arterial–peripheral venous (A-PV) difference for all commonly used acid–base parameters (pH, Pco 2, and bicarbonate). Design, Setting, Participants, and Measurements: Data were obtained prospectively from adult patients with trauma. When an ABG was obtained for clinical purposes, a VBG was drawn as soon as possible. Patients were excluded if the ABG and VBG were drawn >10 minutes apart. Results: The correlations between A-PV pH, A-PV Pco 2, and A-PV bicarbonate and SBP were not statistically significant ( P = .55, .17, and .09, respectively). Although patients with hypotension had a lower mean arterial and peripheral venous pH and bicarbonate compared to hemodynamically stable patients, mean A-PV differences for pH and Pco 2 were not statistically different ( P = .24 and .16, respectively) between hypotensive and normotensive groups. Conclusions: In hypovolemic shock, the peripheral VBG does not demonstrate a higher CO2 concentration and lower pH compared to arterial blood. Therefore, the peripheral VBG is not a surrogate for the tissue acid–base status in hypovolemic shock, likely due to peripheral vasoconstriction and central shunting of blood to essential organs. This contrasts with the selective venous respiratory acidosis previously demonstrated in central venous and mixed venous measurements in circulatory failure, which is more reflective of acid–base imbalance at the tissue level than arterial blood. Further work needs to be done to better define the relationship between ABG and both central and peripheral VBG values in various types of shock.
- 7 March 2018
- Published by SAGE Publications in Journal of Intensive Care Medicine
- Vol. 35 (5) , 511-518
Assessing Acid–Base Status in Circulatory Failure: Relationship Between Arterial and Peripheral Venous Blood Gas Measurements in Hypovolemic Shock
Background and Objectives: In severe circulatory failure agreement between arterial and mixed venous or central venous values is poor; venous values are more reflective of tissue acid–base imbalance. No prior study has examined the relationship between peripheral venous blood gas (VBG) values and arterial blood gas (ABG) values in hemodynamic compromise. The objective of this study was to examine the correlation between hemodynamic parameters, specifically systolic blood pressure (SBP) and the arterial–peripheral venous (A-PV) difference for all commonly used acid–base parameters (pH, Pco 2, and bicarbonate). Design, Setting, Participants, and Measurements: Data were obtained prospectively from adult patients with trauma. When an ABG was obtained for clinical purposes, a VBG was drawn as soon as possible. Patients were excluded if the ABG and VBG were drawn >10 minutes apart. Results: The correlations between A-PV pH, A-PV Pco 2, and A-PV bicarbonate and SBP were not statistically significant ( P = .55, .17, and .09, respectively). Although patients with hypotension had a lower mean arterial and peripheral venous pH and bicarbonate compared to hemodynamically stable patients, mean A-PV differences for pH and Pco 2 were not statistically different ( P = .24 and .16, respectively) between hypotensive and normotensive groups. Conclusions: In hypovolemic shock, the peripheral VBG does not demonstrate a higher CO2 concentration and lower pH compared to arterial blood. Therefore, the peripheral VBG is not a surrogate for the tissue acid–base status in hypovolemic shock, likely due to peripheral vasoconstriction and central shunting of blood to essential organs. This contrasts with the selective venous respiratory acidosis previously demonstrated in central venous and mixed venous measurements in circulatory failure, which is more reflective of acid–base imbalance at the tissue level than arterial blood. Further work needs to be done to better define the relationship between ABG and both central and peripheral VBG values in various types of shock.
- Open Access
- 1 March 2010
- Published by Wolters Kluwer Health in Clinical Journal of the American Society of Nephrology
- Vol. 5 (3) , 390-394
Agreement between Central Venous and Arterial Blood Gas Measurements in the Intensive Care Unit
Background and objectives: Venous blood gas (VBG) analysis is a safer procedure than arterial blood gas (ABG) analysis and may be an alternative for determining acid-base status. The objective of this study was to examine the agreement between ABG and central VBG samples for all commonly used parameters in a medical intensive care unit (ICU) population. Design, setting, participants, & measurements: We performed a single-center, prospective trial to assess the agreement between arterial and central VBG measurements in a medical ICU. Adult patients who were admitted to the ICU and required both a central venous line and an arterial line were enrolled. When an ABG was performed, a central venous sample was obtained to examine the agreement among the pH, Pco2, and bicarbonate. Data comparing central and peripheral VBG values were also obtained. Results: The mean arterial minus venous difference for pH, Pco2, and bicarbonate was 0.027, −3.8, and −0.80, respectively. Bland-Altman plots for agreement of pH, Pco2, and bicarbonate showed 95% limits of agreement of −0.028 to 0.081, −12.3 to 4.8, and −4.0 to 2.4, respectively. Regression equations were derived to predict arterial values from venous values as follows: Arterial pH = −0.307 + 1.05 × venous pH, arterial Pco2 = 0.805 + 0.936 × venous Pco2, and arterial bicarbonate = 0.513 + 0.945 × venous bicarbonate. The mean central minus peripheral differences for pH, Pco2, and bicarbonate were not clinically important. Conclusions: Peripheral or central venous pH, Pco2, and bicarbonate can replace their arterial equivalents in many clinical contexts encountered in the ICU.
- 1 March 2010
- Published by Wolters Kluwer Health in Clinical Journal of the American Society of Nephrology
- Vol. 5 (3) , 390-394
Open AccessAgreement between Central Venous and Arterial Blood Gas Measurements in the Intensive Care Unit
Background and objectives: Venous blood gas (VBG) analysis is a safer procedure than arterial blood gas (ABG) analysis and may be an alternative for determining acid-base status. The objective of this study was to examine the agreement between ABG and central VBG samples for all commonly used parameters in a medical intensive care unit (ICU) population. Design, setting, participants, & measurements: We performed a single-center, prospective trial to assess the agreement between arterial and central VBG measurements in a medical ICU. Adult patients who were admitted to the ICU and required both a central venous line and an arterial line were enrolled. When an ABG was performed, a central venous sample was obtained to examine the agreement among the pH, Pco2, and bicarbonate. Data comparing central and peripheral VBG values were also obtained. Results: The mean arterial minus venous difference for pH, Pco2, and bicarbonate was 0.027, −3.8, and −0.80, respectively. Bland-Altman plots for agreement of pH, Pco2, and bicarbonate showed 95% limits of agreement of −0.028 to 0.081, −12.3 to 4.8, and −4.0 to 2.4, respectively. Regression equations were derived to predict arterial values from venous values as follows: Arterial pH = −0.307 + 1.05 × venous pH, arterial Pco2 = 0.805 + 0.936 × venous Pco2, and arterial bicarbonate = 0.513 + 0.945 × venous bicarbonate. The mean central minus peripheral differences for pH, Pco2, and bicarbonate were not clinically important. Conclusions: Peripheral or central venous pH, Pco2, and bicarbonate can replace their arterial equivalents in many clinical contexts encountered in the ICU.