    Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system

    by Jessica L. Nute, Megan C. Jacobsen, Wolfgang Stefan, Wei Wei, Dianna D. Cody

    PurposeA prototype QC phantom system and analysis process were developed to characterize the spectral capabilities of a fast kV-switching dual-energy computed tomography (DECT) scanner. This work addresses the current lack of quantitative oversight for this technology, with the goal of identifying relevant scan parameters and test metrics instrumental to the development of a dual-energy quality control (DEQC). MethodsA prototype elliptical phantom (effective diameter: 35 cm) was designed with multiple material inserts for DECT imaging. Inserts included tissue equivalent and material rods (including iodine and calcium at varying concentrations). The phantom was scanned on a fast kV-switching DECT system using 16 dual-energy acquisitions (CTDIvol range: 10.3-62 mGy) with varying pitch, rotation time, and tube current. The circular head phantom (22 cm diameter) was scanned using a similar protocol (12 acquisitions; CTDIvol range: 36.7-132.6 mGy). All acquisitions were reconstructed at 50, 70, 110, and 140 keV and using a water-iodine material basis pair. The images were evaluated for iodine quantification accuracy, stability of monoenergetic reconstruction CT number, noise, and positional constancy. Variance component analysis was used to identify technique parameters that drove deviations in test metrics. Variances were compared to thresholds derived from manufacturer tolerances to determine technique parameters that had a nominally significant effect on test metrics. ResultsIodine quantification error was largely unaffected by any of the technique parameters investigated. Monoenergetic HU stability was found to be affected by mAs, with a threshold under which spectral separation was unsuccessful, diminishing the utility of DECT imaging. Noise was found to be affected by CTDIvol in the DEQC body phantom, and CTDIvol and mA in the DEQC head phantom. Positional constancy was found to be affected by mAs in the DEQC body phantom and mA in the DEQC head phantom. ConclusionA streamlined scan protocol was developed to further investigate the effects of CTDIvol and rotation time while limiting data collection to the DEQC body phantom. Further data collection will be pursued to determine baseline values and statistically based failure thresholds for the validation of long-term DECT scanner performance.


  • Open Access

    "How to" incorporate dual-energy imaging into a high volume abdominal imaging practice.

    by Eric P. Tamm, Ott Le, Xinming Liu, Rick R. Layman, Dianna D. Cody, Priya R. Bhosale


  • Management of auto exposure control during pediatric computed tomography

    by Dianna D. Cody

    Automatic exposure control (AEC) is particularly well-suited for pediatric CT scanning. However the importance of the localizer scan portion of exams that relies on AEC is frequently underestimated. This paper explains in detail several crucial aspects of the localizer and their effect on the subsequent cross-sectional (axial or helical) image acquisition. The paper also covers general suggestions regarding AEC influence on the cross-sectional images. AEC systems on CT scanners are becoming more complex; using them effectively in the setting of pediatric CT requires careful selection of scan parameters.


  • Development of pediatric CT protocols for specific scanners: why bother?

    by Dianna D. Cody

    When determining a strategy for pediatric CT scanning, clinical staff can either elect to adjust routine adult-protocol parameter settings on a case-by-case basis or rely on pre-set pediatric protocol parameters. The advantages of the latter approach are the topic of this manuscript. This paper outlines specific options to consider, including the need for regular protocol review.

  • Varying kVp as a means of reducing CT breast dose to pediatric patients

    by K B Mathieu, A C Turner, M Khatonabadi, M F McNitt-Gray, C H Cagnon, D D Cody

    We investigated the possibility of reducing radiation dose to the breast tissue of pediatric females by using multiple tube voltages within a single CT examination. The peak kilovoltage (kVp) was adjusted when the x-ray beam was directly exposing the representative breast tissue of a 5-year-old, 10-year-old, and an adult female anthropomorphic phantom; this strategy was called kVp splitting and was emulated by using a different kVp over the anterior and posterior tube angles. Dose savings from kVp splitting were calculated relative to using a fixed kVp over all tube angles and the results indicated savings in all three phantoms when using 80 kVp over the posterior tube angles regardless of the anterior kVp. Monte Carlo (MC) simulations with and without kVp splitting were performed to estimate absorbed breast dose in voxelized models constructed from the CT images of pediatric female patients; 80 kVp was used over the posterior tube angles. The MC simulations revealed breast dose savings of between 9.8% and 33% from using kVp splitting compared to simulations using a fixed kVp protocol with the anterior technique. Before this strategy could be implemented clinically, the development of suitable image reconstruction algorithms and the image quality of scans with kVp splitting would need further study.


  • Evaluation of over 100 scanner‐years of computed tomography daily quality control data

    by Jessica L. Nute, John Rong, Donna M. Stevens, Brandan J. Darensbourg, Jing Cheng, Wei Wei, Brian P. Hobbs, Dianna D. Cody

    Purpose:: The results of a long‐term, comprehensive CT quality control (QC) program were analyzed to investigate differences in failure rates based on QC test, scanner utilization pattern, and number of channels, as well as explore issues regarding testing frequency.Methods:: CT QC data were collected over a 4‐yr period for 26 CT scanners representing two different vendors and using three different QC programs culminating in over 100 scanner‐years of QC data. QC tests analyzed included water tests [mean CT number, standard deviation, and uniformity], linearity tests [air, water, and acrylic], and artifact analysis [water phantom and large phantom]. The data were organized based on scanner use, number of channels, scanner modality, and QC test. Logistic regression model analysis with generalized estimating equation method was used to estimate failure rates for each group.Results:: A significant difference between failure rates with respect to QC test was found (p‐value = 0.02). Large phantom artifacts, standard deviation of water, and water phantom artifacts had the three highest failure rates. No significant difference was found between failure rates organized by scanner use, scanner modality, or number of channels.Conclusions:: Standard deviation of water is the most important quantitative value to collect as part of a daily QC program. Uniformity and linearity tests have relatively low failure rates and, therefore, may not require daily verification. While its failure rates were moderate, daily artifact analysis is suggested due to its potentially high impact on clinical image quality. Weekly or monthly large phantom artifact analysis is encouraged for those sites possessing an appropriate phantom.


  • Partial Arc Beam Filtration: A Novel Approach to Reducing CT Breast Radiation Dose

    by Kelsey B. Mathieu, Dianna D. Cody

    OBJECTIVE. We sought to assess the effectiveness of a novel CT radiation dose reduction strategy in which filtration was added at the x-ray tube output port between the x-ray beam and the breast area of three sizes of anthropomorphic phantoms. MATERIALS AND METHODS. To evaluate the dose-reduction potential of partial arc x-ray beam filtration, copper foil filtration or lead foil filtration was placed over CT scanners' covers when scanning anthropomorphic phantoms representative of a 5-year-old child, a 10-year-old child, and an adult female. Dose reduction was calculated as the percentage difference between the mean entrance radiation dose (on the phantoms' surfaces at locations representing the sternum and left breast) in unshielded scans compared with the mean dose in scans shielded by copper or lead foil. We also compared the CT numbers and noise sampled in regions representing the lung and the soft tissues near the sternum, left breast, and spine in CT images of the phantoms during unshielded scans relative to acquisitions shielded by copper or lead foil. RESULTS. Entrance dose at the sternum and left breast in the three anthropomorphic phantoms was reduced by 28–66% and 54–79% when using copper or lead foil filtration, respectively. However, copper foil filtration affected the CT numbers and noise in the CT images less than the lead foil filtration did (8.2% vs 32% mean increase in noise). CONCLUSION. By incorporating partial arc beam filtration into CT scanners, substantial dose reductions may be achieved with a minimal increase in image noise.


  • An empirical model of diagnostic x-ray attenuation under narrow-beam geometry

    by Kelsey B. Mathieu, S. Cheenu Kappadath, R. Allen White, E. Neely Atkinson, Dianna D. Cody

    The purpose of this study was to develop and validate a mathematical model to describe narrow-beam attenuation of kilovoltage x-ray beams for the intended applications of half-value layer (HVL) and quarter-value layer (QVL) estimations, patient organ shielding, and computer modeling. An empirical model, which uses the Lambert W function and represents a generalized Lambert-Beer law, was developed. To validate this model, transmission of diagnostic energy x-ray beams was measured over a wide range of attenuator thicknesses [0.49-33.03 mm Al on a computed tomography (CT) scanner, 0.09-1.93 mm Al on two mammography systems, and 0.1-0.45 mm Cu and 0.49-14.87 mm Al using general radiography]. Exposure measurements were acquired under narrow-beam geometry using standard methods, including the appropriate ionization chamber, for each radiographic system. Nonlinear regression was used to find the best-fit curve of the proposed Lambert W model to each measured transmission versus attenuator thickness data set. In addition to validating the Lambert W model, we also assessed the performance of two-point Lambert W interpolation compared to traditional methods for estimating the HVL and QVL [i.e., semi-logarithmic (exponential) and linear interpolation]. The Lambert W model was validated for modeling attenuation versus attenuator thickness with respect to the data collected in this study (R2 > 0.99). Furthermore, Lambert W interpolation was more accurate and less sensitive to the choice of interpolation points used to estimate the HVL and/or QVL than the traditional methods of semilogarithmic and linear interpolation. The proposed Lambert W model accurately describes attenuation of both monoenergetic radiation and (kilovoltage) polyenergetic beams (under narrow-beam geometry).


  • Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

    by Kelsey B. Mathieu, Michael F. McNitt-Gray, Di Zhang, Hyun J. Kim, Dianna D. Cody

    Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI100,air); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDIW) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI100,air values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI100,air ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDIW for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well under 5%).


  • Normalized CT Dose Index of the CT Scanners Used in the National Lung Screening Trial

    by Dianna D. Cody, Hyun-Jung Kim, Christopher H. Cagnon, Frederick J. Larke, Michael M. McNitt-Gray, Randell L. Kruger, Michael J. Flynn, J. Anthony Seibert, Philip F. Judy, Xizeng Wu

    OBJECTIVE. The National Lung Screening Trial includes 33 participating institutions that performed 75,133 lung cancer screening CT examinations for 26,724 subjects during 2002–2007. For trial quality assurance reasons, CT radiation dose measurement data were collected from all MDCT scanners used in the trial.MATERIALS AND METHODS. A total of 247 measurements on 96 MDCT scanners were collected using a standard CT dose index (CTDI) measurement protocol. The scan parameters used in the measurements (tube voltage, milliampere-seconds [mAs], and detector–channel configuration) were set according to trial protocol for average size subjects. The normalized weighted CT dose index (CTDIw) (computed as CTDIw/mAs) obtained from each trial-participating scanner was tabulated.RESULTS. We found a statistically significant difference in normalized CT dose index among CT scanner manufacturers, likely as a result of design differences, such as filtration, bow-tie design, and geometry. Our findings also indicated a statist...