Shale Dames
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shale Dames has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Jacob Durtschi
2 shared publications- Karen Eilbeck
Department of Biomedical Informatics, University of Utah, 421 Wakara Way, Salt Lake City, UT, 84108, United States, 1 801 5814080
2 shared publications Karl V Voelkerding
2 shared publicationsKarl V. Voelkerding
2 shared publicationsRong Mao
2 shared publicationsCarl T Wittwer
ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT
1 shared publication
Latest Publications
- 6 January 2015
- Published by Springer Nature
- Vol. 1264, 77-88
A High-Throughput Next-Generation Sequencing Assay for the Mitochondrial Genome
Next-generation sequencing (NGS) is an effective method for mitochondrial genome (mtDNA) sequencing and heteroplasmy detection. The following protocol describes an mtDNA enrichment method up to library preparation and sequencing on Illumina NGS platforms. A short command line alignment script is available for download via FTP.
- 6 January 2015
- Published by Springer Nature
- Vol. 1264, 77-88
A High-Throughput Next-Generation Sequencing Assay for the Mitochondrial Genome
Next-generation sequencing (NGS) is an effective method for mitochondrial genome (mtDNA) sequencing and heteroplasmy detection. The following protocol describes an mtDNA enrichment method up to library preparation and sequencing on Illumina NGS platforms. A short command line alignment script is available for download via FTP.
- 1 July 2013
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 15 (4) , 526-534
The Development of Next-Generation Sequencing Assays for the Mitochondrial Genome and 108 Nuclear Genes Associated with Mitochondrial Disorders
- 1 July 2013
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 15 (4) , 526-534
The Development of Next-Generation Sequencing Assays for the Mitochondrial Genome and 108 Nuclear Genes Associated with Mitochondrial Disorders
- 1 July 2010
- Vol. 21 (2) , 73-80
Comparison of the Illumina Genome Analyzer and Roche 454 GS FLX for resequencing of hypertrophic cardiomyopathy-associated genes.
Next-generation sequencing (NGS) is widely used in biomedical research, but its adoption has been limited in molecular diagnostics. One application of NGS is the targeted resequencing of genes whose mutations lead to an overlapping clinical phenotype. This study evaluated the comparative performance of the Illumina Genome Analyzer and Roche 454 GS FLX for the resequencing of 16 genes associated with hypertrophic cardiomyopathy (HCM). Using a single human genomic DNA sample enriched by long-range PCR (LR-PCR), 40 GS FLX and 31 Genome Analyzer exon variants were identified using >or=30-fold read-coverage and >or=20% read-percentage selection criteria. Twenty-seven platform concordant variants were Sanger-confirmed. The discordant variants segregated into two categories: variants with read coverages >or=30 on one platform but or=20% on one platform but or=30-fold is too stringent for variant discovery. The variants with <20% read percentage were identified as reference sequence based on Sanger sequencing. These variants were found in homopolymer tracts and short-read misalignments, specifically in genes with high identity. The results of the current study demonstrate the feasibility of combining LR-PCR with the Genome Analyzer or GS FLX for targeted resequencing of HCM-associated genes.
- 1 July 2010
- Vol. 21 (2) , 73-80
Comparison of the Illumina Genome Analyzer and Roche 454 GS FLX for resequencing of hypertrophic cardiomyopathy-associated genes.
Next-generation sequencing (NGS) is widely used in biomedical research, but its adoption has been limited in molecular diagnostics. One application of NGS is the targeted resequencing of genes whose mutations lead to an overlapping clinical phenotype. This study evaluated the comparative performance of the Illumina Genome Analyzer and Roche 454 GS FLX for the resequencing of 16 genes associated with hypertrophic cardiomyopathy (HCM). Using a single human genomic DNA sample enriched by long-range PCR (LR-PCR), 40 GS FLX and 31 Genome Analyzer exon variants were identified using >or=30-fold read-coverage and >or=20% read-percentage selection criteria. Twenty-seven platform concordant variants were Sanger-confirmed. The discordant variants segregated into two categories: variants with read coverages >or=30 on one platform but or=20% on one platform but or=30-fold is too stringent for variant discovery. The variants with <20% read percentage were identified as reference sequence based on Sanger sequencing. These variants were found in homopolymer tracts and short-read misalignments, specifically in genes with high identity. The results of the current study demonstrate the feasibility of combining LR-PCR with the Genome Analyzer or GS FLX for targeted resequencing of HCM-associated genes.
- Open Access
- 1 October 2007
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 53 (10) , 1847-1854
Unlabeled Probes for the Detection and Typing of Herpes Simplex Virus
Background: Unlabeled probe detection with a double-stranded DNA (dsDNA) binding dye is one method to detect and confirm target amplification after PCR. Unlabeled probes and amplicon melting have been used to detect small deletions and single-nucleotide polymorphisms in assays where template is in abundance. Unlabeled probes have not been applied to low-level target detection, however. Methods: Herpes simplex virus (HSV) was chosen as a model to compare the unlabeled probe method to an in-house reference assay using dual-labeled, minor groove binding probes. A saturating dsDNA dye (LCGreen® Plus) was used for real-time PCR. HSV-1, HSV-2, and an internal control were differentiated by PCR amplicon and unlabeled probe melting analysis after PCR. Results: The unlabeled probe technique displayed 98% concordance with the reference assay for the detection of HSV from a variety of archived clinical samples (n = 182). HSV typing using unlabeled probes was 99% concordant (n = 104) to sequenced clinical samples and allowed for the detection of sequence polymorphisms in the amplicon and under the probe. Conclusions: Unlabeled probes and amplicon melting can be used to detect and genotype as few as 10 copies of target per reaction, restricted only by stochastic limitations. The use of unlabeled probes provides an attractive alternative to conventional fluorescence-labeled, probe-based assays for genotyping and detection of HSV and might be useful for other low-copy targets where typing is informative.
- 1 October 2007
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 53 (10) , 1847-1854
Open AccessUnlabeled Probes for the Detection and Typing of Herpes Simplex Virus
Background: Unlabeled probe detection with a double-stranded DNA (dsDNA) binding dye is one method to detect and confirm target amplification after PCR. Unlabeled probes and amplicon melting have been used to detect small deletions and single-nucleotide polymorphisms in assays where template is in abundance. Unlabeled probes have not been applied to low-level target detection, however. Methods: Herpes simplex virus (HSV) was chosen as a model to compare the unlabeled probe method to an in-house reference assay using dual-labeled, minor groove binding probes. A saturating dsDNA dye (LCGreen® Plus) was used for real-time PCR. HSV-1, HSV-2, and an internal control were differentiated by PCR amplicon and unlabeled probe melting analysis after PCR. Results: The unlabeled probe technique displayed 98% concordance with the reference assay for the detection of HSV from a variety of archived clinical samples (n = 182). HSV typing using unlabeled probes was 99% concordant (n = 104) to sequenced clinical samples and allowed for the detection of sequence polymorphisms in the amplicon and under the probe. Conclusions: Unlabeled probes and amplicon melting can be used to detect and genotype as few as 10 copies of target per reaction, restricted only by stochastic limitations. The use of unlabeled probes provides an attractive alternative to conventional fluorescence-labeled, probe-based assays for genotyping and detection of HSV and might be useful for other low-copy targets where typing is informative.
- 1 July 2007
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 9 (3) , 290-296
Characterization of Aberrant Melting Peaks in Unlabeled Probe Assays
- 1 July 2007
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 9 (3) , 290-296
Characterization of Aberrant Melting Peaks in Unlabeled Probe Assays
- 1 March 2007
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 127 (3) , 341-348
Closed-Tube SNP Genotyping Without Labeled Probes/A Comparison Between Unlabeled Probe and Amplicon Melting
- 1 March 2007
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 127 (3) , 341-348
Closed-Tube SNP Genotyping Without Labeled Probes/A Comparison Between Unlabeled Probe and Amplicon Melting
- 28 February 2006
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 8 (1) , 16-21
A Single-Tube Nucleic Acid Extraction, Amplification, and Detection Method Using Aluminum Oxide
- 28 February 2006
- Published by Elsevier in The Journal of Molecular Diagnostics
- Vol. 8 (1) , 16-21
A Single-Tube Nucleic Acid Extraction, Amplification, and Detection Method Using Aluminum Oxide