Charlotta Olivecrona
Research Subjects
Charlotta Olivecrona has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Sari Ponzer
Department of Clinical Science and education, Karolinska Institutet, Södersjukhuset, Stockholm, Sweden
3 shared publications Richard Blomfeldt
Section of Orthopedics, Department of Clinical Science and Education, Södersjukhuset Karolinska Institutet, Stockholm, Sweden
2 shared publicationsBengt Y Nilsson
1 shared publicationBenjamin Ribalta Stanford
1 shared publicationClaes Cederfjäll
1 shared publicationJan Tidermark
1 shared publication
Latest Publications
- 16 February 2013
- Published by Springer Nature in International Orthopaedics
- Vol. 37 (5) , 827-832
Tourniquet time affects postoperative complications after knee arthroplasty
Purpose Pneumatic tourniquets are frequently used in knee arthroplasty surgery. However, there is a lack of evidence to define safe tourniquet time in lower limb surgery. The primary aim of this study was to investigate whether tourniquet time influences the risk of postoperative complications after primary and secondary knee arthroplasty. Methods This study was a prospective register study. Since we wanted dispersion in tourniquet time, we included a consecutive series of 577 primary knee arthroplasties, 46 revision knee arthroplasties, and 18 patellar supplementing knee arthroplasties from a clinical audit database over a period of five years. The following postoperative complications were recorded: superficial wound infections, deep wound infections, deep vein thrombosis, pulmonary embolism, nerve injuries, compartment syndrome, cuff pressure injuries, and bandage injuries. Results Tourniquet time over 100 minutes was associated with an increased risk of complications after knee arthroplasty surgery (OR 2.2, CI 1.5–3.1). This increase in risk remained after adjusting for cuff pressure, sex, age, American Society of Anesthesiologists (ASA) classification, smoking, diabetes, and surgery indication (OR 2.4, CI 1.6–3.6). Conclusions Tourniquet time over 100 minutes increases the risk of complications after knee arthroplasty surgery and special attention is advocated to reduce the tourniquet time.
- 16 February 2013
- Published by Springer Nature in International Orthopaedics
- Vol. 37 (5) , 827-832
Tourniquet time affects postoperative complications after knee arthroplasty
Purpose Pneumatic tourniquets are frequently used in knee arthroplasty surgery. However, there is a lack of evidence to define safe tourniquet time in lower limb surgery. The primary aim of this study was to investigate whether tourniquet time influences the risk of postoperative complications after primary and secondary knee arthroplasty. Methods This study was a prospective register study. Since we wanted dispersion in tourniquet time, we included a consecutive series of 577 primary knee arthroplasties, 46 revision knee arthroplasties, and 18 patellar supplementing knee arthroplasties from a clinical audit database over a period of five years. The following postoperative complications were recorded: superficial wound infections, deep wound infections, deep vein thrombosis, pulmonary embolism, nerve injuries, compartment syndrome, cuff pressure injuries, and bandage injuries. Results Tourniquet time over 100 minutes was associated with an increased risk of complications after knee arthroplasty surgery (OR 2.2, CI 1.5–3.1). This increase in risk remained after adjusting for cuff pressure, sex, age, American Society of Anesthesiologists (ASA) classification, smoking, diabetes, and surgery indication (OR 2.4, CI 1.6–3.6). Conclusions Tourniquet time over 100 minutes increases the risk of complications after knee arthroplasty surgery and special attention is advocated to reduce the tourniquet time.
- Open Access
- 1 January 2013
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 84 (2) , 159-164
Tourniquet cuff pressure and nerve injury in knee arthroplasty in a bloodless field
Tourniquet-related nerve injuries remain a concern in orthopedic surgery. The cuff pressures used today are generally lower, and therefore a decreasing incidence of peripheral nerve injuries might also be expected. However, there have been few neurophysiological studies describing the outcome after bloodless field surgery. We describe the results of neurophysiological examinations and report the incidence of nerve injuries after total knee arthroplasty (TKA) in a bloodless field. This study was part of a prospective, randomized controlled clinical trial in patients scheduled for TKA in a bloodless field. 20 consecutive patients were enrolled. Electroneurography (ENeG) and quantitative sensory testing (QST) of thermal thresholds were performed on day 3. These tests were repeated 2 months after surgery when electromyography (EMG) with a concentric-needle electrode was also performed. The mean tourniquet cuff pressure was 237 (SD 33) mmHg. Electromyographic signs of denervation were found in 1 patient, who also had the highest cuff pressure in the study population (294 mmHg). The sensory nerve response amplitudes were lower in the operated leg on day 3; otherwise, the neurophysiological examinations showed no differences between the legs. When low tourniquet cuff pressures are used the risk of nerve injury is minor.
- 1 January 2013
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 84 (2) , 159-164
Open AccessTourniquet cuff pressure and nerve injury in knee arthroplasty in a bloodless field
Tourniquet-related nerve injuries remain a concern in orthopedic surgery. The cuff pressures used today are generally lower, and therefore a decreasing incidence of peripheral nerve injuries might also be expected. However, there have been few neurophysiological studies describing the outcome after bloodless field surgery. We describe the results of neurophysiological examinations and report the incidence of nerve injuries after total knee arthroplasty (TKA) in a bloodless field. This study was part of a prospective, randomized controlled clinical trial in patients scheduled for TKA in a bloodless field. 20 consecutive patients were enrolled. Electroneurography (ENeG) and quantitative sensory testing (QST) of thermal thresholds were performed on day 3. These tests were repeated 2 months after surgery when electromyography (EMG) with a concentric-needle electrode was also performed. The mean tourniquet cuff pressure was 237 (SD 33) mmHg. Electromyographic signs of denervation were found in 1 patient, who also had the highest cuff pressure in the study population (294 mmHg). The sensory nerve response amplitudes were lower in the operated leg on day 3; otherwise, the neurophysiological examinations showed no differences between the legs. When low tourniquet cuff pressures are used the risk of nerve injury is minor.
- 1 December 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (24) , 2216-2221
Lower Tourniquet Cuff Pressure Reduces Postoperative Wound Complications After Total Knee Arthroplasty
Background: Measurement of limb occlusion pressure before surgery might lead to the use of a lower tourniquet cuff pressure during surgery and thereby reduce the risk of postoperative pain and complications. The primary aim of this study was to investigate whether the limb-occlusion-pressure method reduces the tourniquet cuff pressure used during total knee arthroplasty and if this leads to less postoperative pain compared with that experienced by patients on whom this method is not used. The secondary aim was to investigate whether there were any differences regarding the quality of the bloodless field, range of motion, and postoperative wound complications. Methods: One hundred and sixty-four patients scheduled to be treated with a total knee arthroplasty were randomized to a control group or to undergo the intervention under study (the limb-occlusion-pressure [LOP] group). In the control group, the tourniquet cuff pressure was based on the patient’s systolic blood pressure and a margin decided by the surgeon (the routine method). In the LOP group, the tourniquet cuff pressure was based on the measurement of the limb occlusion pressure. The primary outcome measure was postoperative pain, and the secondary outcome measures were the quality of the bloodless field, knee motion, and wound-related complications at discharge and two months after surgery. Results: The tourniquet cuff pressure was significantly lower in the LOP group than in the control group (p < 0.001). We could not demonstrate any differences between the groups regarding postoperative pain or complications, although the number of postoperative complications was relatively high in both groups. However, at discharge forty of the forty-seven patients with a wound complication had had a cuff pressure above 225 mm Hg and at the two-month follow-up evaluation fourteen of the sixteen patients with a wound complication had had a cuff pressure above 225 mm Hg. Conclusions: The limb-occlusion-pressure method reduces the cuff pressure without reducing the quality of the bloodless field, but there were no differences in outcomes between the groups. An important secondary finding was that patients with a cuff pressure of ≤225 mm Hg had no postoperative infections and a lower rate of wound complications. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- 1 December 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (24) , 2216-2221
Lower Tourniquet Cuff Pressure Reduces Postoperative Wound Complications After Total Knee Arthroplasty
Background: Measurement of limb occlusion pressure before surgery might lead to the use of a lower tourniquet cuff pressure during surgery and thereby reduce the risk of postoperative pain and complications. The primary aim of this study was to investigate whether the limb-occlusion-pressure method reduces the tourniquet cuff pressure used during total knee arthroplasty and if this leads to less postoperative pain compared with that experienced by patients on whom this method is not used. The secondary aim was to investigate whether there were any differences regarding the quality of the bloodless field, range of motion, and postoperative wound complications. Methods: One hundred and sixty-four patients scheduled to be treated with a total knee arthroplasty were randomized to a control group or to undergo the intervention under study (the limb-occlusion-pressure [LOP] group). In the control group, the tourniquet cuff pressure was based on the patient’s systolic blood pressure and a margin decided by the surgeon (the routine method). In the LOP group, the tourniquet cuff pressure was based on the measurement of the limb occlusion pressure. The primary outcome measure was postoperative pain, and the secondary outcome measures were the quality of the bloodless field, knee motion, and wound-related complications at discharge and two months after surgery. Results: The tourniquet cuff pressure was significantly lower in the LOP group than in the control group (p < 0.001). We could not demonstrate any differences between the groups regarding postoperative pain or complications, although the number of postoperative complications was relatively high in both groups. However, at discharge forty of the forty-seven patients with a wound complication had had a cuff pressure above 225 mm Hg and at the two-month follow-up evaluation fourteen of the sixteen patients with a wound complication had had a cuff pressure above 225 mm Hg. Conclusions: The limb-occlusion-pressure method reduces the cuff pressure without reducing the quality of the bloodless field, but there were no differences in outcomes between the groups. An important secondary finding was that patients with a cuff pressure of ≤225 mm Hg had no postoperative infections and a lower rate of wound complications. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 January 2006
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (3) , 519-523
Skin protection underneath the pneumatic tourniquet during total knee arthroplasty: A randomized controlled trial of 92 patients
The use of a pneumatic tourniquet to obtain a bloodless field during a total knee arthroplasty (TKA) allows the surgeon to work with greater technical precision in a safe, clear environment. Despite the benefits of surgical tourniquets and many advances in tourniquet equipment, their use is not without risk and complications may still occur. The primary aim of this study was to determine whether there are any differences between an elastic stockinette, cast padding, and no protective material at all regarding skin injuries after a primary TKA in a bloodless field using a pneumatic tourniquet. 92 patients were randomized to 1 of 3 groups. In the first group, the limb underneath the pneumatic tourniquet was protected by a two-layer elastic stockinette (E). In the second group, it was protected by cast padding (C), and no protective material (N) was used in the third group. The presence of major skin injuries (blisters) was recorded when the tourniquet was removed after surgery. The two groups with skin protection had fewer skin injuries (p = 0.007). The elastic stockinette was significantly better than having no protective material and there was a trend towards better results in the elastic stockinette group than in the cast padding group. Our findings indicate that protective material underneath the tourniquet cuff reduces the risk of skin injuries, i.e. blisters. An elastic stockinette appears to be best.
- 1 January 2006
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (3) , 519-523
Open AccessSkin protection underneath the pneumatic tourniquet during total knee arthroplasty: A randomized controlled trial of 92 patients
The use of a pneumatic tourniquet to obtain a bloodless field during a total knee arthroplasty (TKA) allows the surgeon to work with greater technical precision in a safe, clear environment. Despite the benefits of surgical tourniquets and many advances in tourniquet equipment, their use is not without risk and complications may still occur. The primary aim of this study was to determine whether there are any differences between an elastic stockinette, cast padding, and no protective material at all regarding skin injuries after a primary TKA in a bloodless field using a pneumatic tourniquet. 92 patients were randomized to 1 of 3 groups. In the first group, the limb underneath the pneumatic tourniquet was protected by a two-layer elastic stockinette (E). In the second group, it was protected by cast padding (C), and no protective material (N) was used in the third group. The presence of major skin injuries (blisters) was recorded when the tourniquet was removed after surgery. The two groups with skin protection had fewer skin injuries (p = 0.007). The elastic stockinette was significantly better than having no protective material and there was a trend towards better results in the elastic stockinette group than in the cast padding group. Our findings indicate that protective material underneath the tourniquet cuff reduces the risk of skin injuries, i.e. blisters. An elastic stockinette appears to be best.