Chaohua Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chaohua Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Xiaodong Xie
Department of Neurosurgery West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
7 shared publications Haiyan Tu
College of Architecture & Environment, Sichuan University, Chengdu 610065, China
3 shared publicationsHongliang Zhang
3 shared publicationsZhirun Yuan
3 shared publicationsB. Mao
1 shared publicationC. You
1 shared publication
Latest Publications
- 1 June 2012
- Vol. 29 (3) , 460-4
[Experimental study on animal with automatic drug injection based on predictive control for vascular interventional therapy].
This paper focuses on the animal experiment of automatic drug delivery based on predictive control for vascular interventional therapy. Improvement of drug delivery system based on predictive control used in simulated experiments was put forward after the presence of time varying parameters and the characteristics of individual differences of animal had been studied. The adaptability of time varying parameters and fault tolerance of the system were also enhanced. Different injection methods were tested on animals. It is proved that higher target blood concentration can be reached while injecting during diastolic than that while injecting during systolic or injecting at a constant speed within the whole cardiac cycle. The results also showed that the improved drug injection system based on predictive control which synchronizes with the cardiac cycle could be applied to clinical trials.
- 1 June 2012
- Vol. 29 (3) , 460-4
[Experimental study on animal with automatic drug injection based on predictive control for vascular interventional therapy].
This paper focuses on the animal experiment of automatic drug delivery based on predictive control for vascular interventional therapy. Improvement of drug delivery system based on predictive control used in simulated experiments was put forward after the presence of time varying parameters and the characteristics of individual differences of animal had been studied. The adaptability of time varying parameters and fault tolerance of the system were also enhanced. Different injection methods were tested on animals. It is proved that higher target blood concentration can be reached while injecting during diastolic than that while injecting during systolic or injecting at a constant speed within the whole cardiac cycle. The results also showed that the improved drug injection system based on predictive control which synchronizes with the cardiac cycle could be applied to clinical trials.
- 1 January 2012
- Vol. 15 (6) , 355-9
Misdiagnosis and management of iatrogenic pseudoaneurysm of vertebral artery after Harms technique of C₁-C₂ fixation.
Harms technique of C₁-C₂ fixation for atlantoaxial complex becomes more popular due to good fusion rate and low vertebral artery injury (VAI) rate. But considering the unique and variable anatomy of atlantoaxial complex, iatrogenic VAI will result in catastrophic consequences and provides particular surgical challenges for surgeons. To our knowledge, comparing with iatrogenic VAI in the screw hole, iatrogenic VAI in the "open space" is much rarer during the Harms technique of C₁-C₂ fixation. In this article, we present a case of iatrogenic vertebral artery pseudoaneurysm after Harms technique of posterior C₁-C₂ fixation. This case of iatrogenic VAI effectively treated by endovascular coil occlusion and external local compression was initially misdiagnosed as VAI by pedicle screw perforation. It can be concluded that intraoperative or postoperative computed angiography is very helpful to diagnose the exact site of VAI and the combination of endovascular coil occlusion as well as external local compression can further prevent bleeding and abnormal vertebral artery flow in the pseudoaneurysm. However, patients treated require further follow-up to confirm that there is no recurrence of the pseudoaneurysm.
- 1 January 2012
- Vol. 15 (6) , 355-9
Misdiagnosis and management of iatrogenic pseudoaneurysm of vertebral artery after Harms technique of C₁-C₂ fixation.
Harms technique of C₁-C₂ fixation for atlantoaxial complex becomes more popular due to good fusion rate and low vertebral artery injury (VAI) rate. But considering the unique and variable anatomy of atlantoaxial complex, iatrogenic VAI will result in catastrophic consequences and provides particular surgical challenges for surgeons. To our knowledge, comparing with iatrogenic VAI in the screw hole, iatrogenic VAI in the "open space" is much rarer during the Harms technique of C₁-C₂ fixation. In this article, we present a case of iatrogenic vertebral artery pseudoaneurysm after Harms technique of posterior C₁-C₂ fixation. This case of iatrogenic VAI effectively treated by endovascular coil occlusion and external local compression was initially misdiagnosed as VAI by pedicle screw perforation. It can be concluded that intraoperative or postoperative computed angiography is very helpful to diagnose the exact site of VAI and the combination of endovascular coil occlusion as well as external local compression can further prevent bleeding and abnormal vertebral artery flow in the pseudoaneurysm. However, patients treated require further follow-up to confirm that there is no recurrence of the pseudoaneurysm.
- 1 February 2011
- Vol. 28 (1) , 67-70
[A simulating excorporeal experimental system for automatic drug injection based on predictive control in vascular interventional therapy].
This paper discusses an in vitro simulating experiment for drug injection based on predictive control in vascular interventional therapy. The relationship between the model of drug injection and the pulsatile blood flow was studied. The experimental model for predictive control of drug injection was tested and verified so as to support the future animal experimental modeling with the data acquired from the in vitro simulating experiment.
- 1 February 2011
- Vol. 28 (1) , 67-70
[A simulating excorporeal experimental system for automatic drug injection based on predictive control in vascular interventional therapy].
This paper discusses an in vitro simulating experiment for drug injection based on predictive control in vascular interventional therapy. The relationship between the model of drug injection and the pulsatile blood flow was studied. The experimental model for predictive control of drug injection was tested and verified so as to support the future animal experimental modeling with the data acquired from the in vitro simulating experiment.
- 1 June 2010
- Vol. 27 (3) , 684-7
[The advances of automatic drug infusion].
The development of automatic drug delivery is reviewed in this paper. The control-relevance of models, the relevant algorithm, the system running and the simulation effect are introduced. The value for clinical application of each case is assessed. The new advances and high-lights of researches are discussed.
- 1 June 2010
- Vol. 27 (3) , 684-7
[The advances of automatic drug infusion].
The development of automatic drug delivery is reviewed in this paper. The control-relevance of models, the relevant algorithm, the system running and the simulation effect are introduced. The value for clinical application of each case is assessed. The new advances and high-lights of researches are discussed.
- Open Access
- 2 April 2009
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 30 (7) , 1342-1346
Placement of Covered Stents for the Treatment of Direct Carotid Cavernous Fistulas
BACKGROUND AND PURPOSE: Endovascular detachable balloon occlusion and coil occlusion are 2 well-established options for the treatment of direct carotid cavernous fistulas (DCCFs). In recent years, covered stents have been applied in the treatment of neurovascular pathologies such as aneurysms, pseudoaneurysms, arterial dissections, and DCCFs. The purpose of this study was to investigate the clinical efficacy of covered stents for the treatment of DCCFs. MATERIALS AND METHODS: Ten consecutive patients underwent covered-stent placement after failure of detachable balloon occlusion for the treatment of their DCCFs. Clinical and angiographic follow-up ranged from 5 to 48 months (mean, 18.2 months) after stent placement. RESULTS: Stent placement was technically successful in all except 1 patient. In this patient, stent placement failed after multiple attempts because of rigidity of the Jostent GraftMaster Coronary Stent Graft and the tortuous anatomy of the internal carotid artery (ICA). Complete exclusion of the fistula was achieved in 6 patients immediately after stent deployment. Endoleak was observed in 3 patients. Re-dilation of the stent avoided the endoleak in 2 patients; in 1 of these 2 patients, formerly improved symptoms recurred the next morning and the ipsilateral ICA was occluded with detachable balloons. Spasm of the ICA was observed in most of the patients after stent placement; however, angioplasty was not required. Symptoms improved in all patients after treatment, without thromboembolic events. Follow-up cerebral angiography showed complete exclusion of all DCCFs and stent patency without intrastent stenosis in the 8 patients who had successful deployment of the stent. CONCLUSIONS: Although a larger sample and expanded follow-up are needed, our series shows that covered stents can be used in the treatment of DCCFs with symptomatic relief.
- 2 April 2009
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 30 (7) , 1342-1346
Open AccessPlacement of Covered Stents for the Treatment of Direct Carotid Cavernous Fistulas
BACKGROUND AND PURPOSE: Endovascular detachable balloon occlusion and coil occlusion are 2 well-established options for the treatment of direct carotid cavernous fistulas (DCCFs). In recent years, covered stents have been applied in the treatment of neurovascular pathologies such as aneurysms, pseudoaneurysms, arterial dissections, and DCCFs. The purpose of this study was to investigate the clinical efficacy of covered stents for the treatment of DCCFs. MATERIALS AND METHODS: Ten consecutive patients underwent covered-stent placement after failure of detachable balloon occlusion for the treatment of their DCCFs. Clinical and angiographic follow-up ranged from 5 to 48 months (mean, 18.2 months) after stent placement. RESULTS: Stent placement was technically successful in all except 1 patient. In this patient, stent placement failed after multiple attempts because of rigidity of the Jostent GraftMaster Coronary Stent Graft and the tortuous anatomy of the internal carotid artery (ICA). Complete exclusion of the fistula was achieved in 6 patients immediately after stent deployment. Endoleak was observed in 3 patients. Re-dilation of the stent avoided the endoleak in 2 patients; in 1 of these 2 patients, formerly improved symptoms recurred the next morning and the ipsilateral ICA was occluded with detachable balloons. Spasm of the ICA was observed in most of the patients after stent placement; however, angioplasty was not required. Symptoms improved in all patients after treatment, without thromboembolic events. Follow-up cerebral angiography showed complete exclusion of all DCCFs and stent patency without intrastent stenosis in the 8 patients who had successful deployment of the stent. CONCLUSIONS: Although a larger sample and expanded follow-up are needed, our series shows that covered stents can be used in the treatment of DCCFs with symptomatic relief.
- Open Access
- 1 January 2008
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 9 (2) , 182-185
Embolization of a Bleeding Maxillary Arteriovenous Malformation via the Superficial Temporal Artery after External Carotid Artery Ligation
Wang C, et al. Korean J Radiol. 2008 Mar-Apr;9(2):182-185. http://dx.doi.org/10.3348/kjr.2008.9.2.182
- 1 January 2008
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 9 (2) , 182-185
Open AccessEmbolization of a Bleeding Maxillary Arteriovenous Malformation via the Superficial Temporal Artery after External Carotid Artery Ligation
Wang C, et al. Korean J Radiol. 2008 Mar-Apr;9(2):182-185. http://dx.doi.org/10.3348/kjr.2008.9.2.182
- 1 December 2007
- Vol. 24 (6) , 1246-9
[Study on the methods for establishing virtual three-dimensional models of cerebral arteries with the three-dimensional moulding software].
This study was conducted to establish the methods of virtual three-dimensional cerebral arteries models by use of three-dimensional moulding software. The virtual models of the cerebral arteries were established using the three-dimensional moulding software of 3D Studio MAX R3 with 46 cases of normal cerebral DSA image as the original. The results showed there was similarity in appearance between the virtual cerebral arteries and DSA image. This is of benefit to understanding the vascular three-dimensional spatial relation in visual sense. Several models of different variant anatomy could be easily established on the copy files of the virtual cerebral arteries model. The virtual model could help learners to create and increase the three-dimensional space concept of arteries and aneurysms in clinical teaching. The results indicated that the virtual three-dimensional cerebral arteries models could display the three-dimensional spatial relation of the cerebral arterial system distinctly, and could serve as a morphologic foundation in the researches on vascular disease.
- 1 December 2007
- Vol. 24 (6) , 1246-9
[Study on the methods for establishing virtual three-dimensional models of cerebral arteries with the three-dimensional moulding software].
This study was conducted to establish the methods of virtual three-dimensional cerebral arteries models by use of three-dimensional moulding software. The virtual models of the cerebral arteries were established using the three-dimensional moulding software of 3D Studio MAX R3 with 46 cases of normal cerebral DSA image as the original. The results showed there was similarity in appearance between the virtual cerebral arteries and DSA image. This is of benefit to understanding the vascular three-dimensional spatial relation in visual sense. Several models of different variant anatomy could be easily established on the copy files of the virtual cerebral arteries model. The virtual model could help learners to create and increase the three-dimensional space concept of arteries and aneurysms in clinical teaching. The results indicated that the virtual three-dimensional cerebral arteries models could display the three-dimensional spatial relation of the cerebral arterial system distinctly, and could serve as a morphologic foundation in the researches on vascular disease.
- 20 August 2003
- Vol. 6 (4)
[Embolotherapy for the management of lung cancer with massive hemoptysis].
To investigate the indication, complication and efficacy of bronchial artery embolization for the management of lung cancer with massive hemoptysis.
- 20 August 2003
- Vol. 6 (4)
[Embolotherapy for the management of lung cancer with massive hemoptysis].
To investigate the indication, complication and efficacy of bronchial artery embolization for the management of lung cancer with massive hemoptysis.