Won-Hee Jee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Won-Hee Jee has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
Joon-Yong Jung
8 shared publicationsJung-Man Kim
7 shared publicationsSo-Yeon Lee
From the Departments of *Radiology, and †Orthopedic Surgery, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
6 shared publications- Chan Kwon Jung
Department of Hospital Pathology, College of Medicine, The Catholic University of Korea, Seoul, Korea
5 shared publications - Kyung Nam Ryu
Department of Radiology, Kyung Hee University Hospital, Kyung Hee University College of Medicine, Seoul, Korea
5 shared publications Yang-Soo Kim
The Catholic University of Korea
5 shared publications
Latest Publications
- Open Access
- 19 July 2015
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 13 (1) , 221
Pseudomyxoma peritonei extending to the lower extremity: a case report
Pseudomyxoma peritonei is characterized by mucinous ascites originating from a mucin-producing neoplasm; however, even the definition is still under debate. Tumor deposits extend and ultimately engulf the entire cavity, causing death from cachexia due to limited intestinal movement. Here, we report a unique case of an 80-year-old woman with pseudomyxoma peritonei, which extended to the lower extremity mimicking infectious condition. The patient survived for a long time without bowel obstruction despite having the histologic subtype that has an unfavorable prognosis. The extremity lesion was treated with limited extensive surgery. The origin of the disease and the mechanism of extension to the extremity could not be clarified. Clinicians should be aware of the original disease entity and this unusual presentation and determine its mechanism and the best management strategy.
- 19 July 2015
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 13 (1) , 221
Open AccessPseudomyxoma peritonei extending to the lower extremity: a case report
Pseudomyxoma peritonei is characterized by mucinous ascites originating from a mucin-producing neoplasm; however, even the definition is still under debate. Tumor deposits extend and ultimately engulf the entire cavity, causing death from cachexia due to limited intestinal movement. Here, we report a unique case of an 80-year-old woman with pseudomyxoma peritonei, which extended to the lower extremity mimicking infectious condition. The patient survived for a long time without bowel obstruction despite having the histologic subtype that has an unfavorable prognosis. The extremity lesion was treated with limited extensive surgery. The origin of the disease and the mechanism of extension to the extremity could not be clarified. Clinicians should be aware of the original disease entity and this unusual presentation and determine its mechanism and the best management strategy.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (2) , 257-262
Lateral Meniscocapsular Separation in Patients With Tibial Plateau Fractures
This study aimed to retrospectively evaluate magnetic resonance imaging findings for the detection of lateral meniscocapsular separation (LMCS) in patients with tibial plateau fractures. We hypothesize that patients with LMCS have greater perimeniscal abnormal signal or greater distance between the lateral meniscus (LM) and the lateral collateral ligament (LCL) than patients without LMCS.The study group included 16 patients with LMCS and 11 patients with normal LMCS who underwent surgery due to tibial plateau fracture. Magnetic resonance images were assessed for the width of perimeniscal abnormal signals on 3 orthogonal planes. The distance between LM and LCL was measured on coronal images. Nonparametric tests were performed.The thickness of perimeniscal abnormal signals was increased in the patient group than in control group (median, 10.00 [interquartile range, 9.00-12.70] mm vs 3.39 [2.45-3.67] mm at axial images [P < 0.001]; 8.60 [3.75-11.26] mm vs 2.73 [1.64-4.38] mm at coronal images [P = 0.015]; 13.57 [9.50-15.04] mm vs 4.65 [0-5.89] mm at sagittal images [P = 0.002], respectively). Sixteen patients in the patient group had involvement around the whole LM, whereas none of the patients in the control group had involvement around the whole LM (P < 0.001). The distance between LM and LCL was increased in the patient group than in the control group (9.00 [7.47-10.75] mm vs 5.11 [4.38-7.07] mm [P = 0.002], respectively). The cutoff value of 7 mm thickness of abnormal signal and distance between LM and LCL showed an accuracy of 96% (26/27 patients) and 85% (23/27 patients), respectively.Patients with perimeniscal signal greater than 7 mm or distance between LM and LCL greater than 7 mm have high likelihood of LMCS.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (2) , 257-262
Lateral Meniscocapsular Separation in Patients With Tibial Plateau Fractures
This study aimed to retrospectively evaluate magnetic resonance imaging findings for the detection of lateral meniscocapsular separation (LMCS) in patients with tibial plateau fractures. We hypothesize that patients with LMCS have greater perimeniscal abnormal signal or greater distance between the lateral meniscus (LM) and the lateral collateral ligament (LCL) than patients without LMCS.The study group included 16 patients with LMCS and 11 patients with normal LMCS who underwent surgery due to tibial plateau fracture. Magnetic resonance images were assessed for the width of perimeniscal abnormal signals on 3 orthogonal planes. The distance between LM and LCL was measured on coronal images. Nonparametric tests were performed.The thickness of perimeniscal abnormal signals was increased in the patient group than in control group (median, 10.00 [interquartile range, 9.00-12.70] mm vs 3.39 [2.45-3.67] mm at axial images [P < 0.001]; 8.60 [3.75-11.26] mm vs 2.73 [1.64-4.38] mm at coronal images [P = 0.015]; 13.57 [9.50-15.04] mm vs 4.65 [0-5.89] mm at sagittal images [P = 0.002], respectively). Sixteen patients in the patient group had involvement around the whole LM, whereas none of the patients in the control group had involvement around the whole LM (P < 0.001). The distance between LM and LCL was increased in the patient group than in the control group (9.00 [7.47-10.75] mm vs 5.11 [4.38-7.07] mm [P = 0.002], respectively). The cutoff value of 7 mm thickness of abnormal signal and distance between LM and LCL showed an accuracy of 96% (26/27 patients) and 85% (23/27 patients), respectively.Patients with perimeniscal signal greater than 7 mm or distance between LM and LCL greater than 7 mm have high likelihood of LMCS.
- Open Access
- 1 January 2014
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 15 (1) , 114-122
MR Findings of the Osteofibrous Dysplasia
Jung JY, et al. Korean J Radiol. 2014 Jan-Feb;15(1):114-122. http://dx.doi.org/10.3348/kjr.2014.15.1.114
- 1 January 2014
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 15 (1) , 114-122
Open AccessMR Findings of the Osteofibrous Dysplasia
Jung JY, et al. Korean J Radiol. 2014 Jan-Feb;15(1):114-122. http://dx.doi.org/10.3348/kjr.2014.15.1.114
- Open Access
- 1 January 2013
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 14 (1) , 102-109
Preliminary Experience Using Dynamic MRI at 3.0 Tesla for Evaluation of Soft Tissue Tumors
Park MY, et al. Korean J Radiol. 2013 Jan-Feb;14(1):102-109. http://dx.doi.org/10.3348/kjr.2013.14.1.102
- 1 January 2013
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 14 (1) , 102-109
Open AccessPreliminary Experience Using Dynamic MRI at 3.0 Tesla for Evaluation of Soft Tissue Tumors
Park MY, et al. Korean J Radiol. 2013 Jan-Feb;14(1):102-109. http://dx.doi.org/10.3348/kjr.2013.14.1.102
- 31 October 2012
- Published by Elsevier in Clinical Imaging
- Vol. 36 (5) , 466-471
Extracranial skeletal Langerhans cell histiocytosis: MR imaging features according to the radiologic evolutional phases
- 31 October 2012
- Published by Elsevier in Clinical Imaging
- Vol. 36 (5) , 466-471
Extracranial skeletal Langerhans cell histiocytosis: MR imaging features according to the radiologic evolutional phases
- 4 August 2012
- Published by Springer Nature in European Radiology
- Vol. 23 (2) , 487-495
SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar’s test, and inter-observer agreement was calculated using Cohen’s kappa. Receiver operating characteristic (ROC) curve analyses were performed. The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE (κ = 0.76) and 3D TSE-SPACE (κ = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions • MR arthrography is regarded as the definitive method of shoulder imaging • Different MR sequences are evolving for SLAP lesions • 3D TSE-SPACE demonstrated comparable overall accuracy to 2D TSE for SLAP lesions • But more false-negative interpretations occurred using 3D TSE-SPACE • Further technical improvement is necessary before 3D TSE-SPACE replaces 2D TSE sequences
- 4 August 2012
- Published by Springer Nature in European Radiology
- Vol. 23 (2) , 487-495
SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences
The aim of this study was to determine the accuracy and reliability of shoulder magnetic resonance (MR) arthrography with three-dimensional (3D) isotropic intermediate-weighted turbo spin-echo (TSE) sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) in the diagnosis of superior labrum anterior-to-posterior (SLAP) lesions compared with two-dimensional (2D) TSE at 3.0 T. MR arthrograms, including 2D TSE and 3D TSE-SPACE, in 87 patients who underwent arthroscopy were retrospectively analysed by two reviewers for the presence and type of SLAP lesions. Sensitivity and specificity were compared using McNemar’s test, and inter-observer agreement was calculated using Cohen’s kappa. Receiver operating characteristic (ROC) curve analyses were performed. The mean sensitivity, specificity and accuracy were 90%, 85% and 86% for 2D TSE, and 81%, 86% and 85% for 3D TSE-SPACE respectively, with no statistically significant differences. Inter-observer agreements were substantial in 2D TSE (κ = 0.76) and 3D TSE-SPACE (κ = 0.68). The areas under the ROC curves were 0.92 for 2D TSE and 0.90 for 3D TSE-SPACE, which were not significantly different. MR arthrography with 3D TSE-SPACE showed comparable accuracy and substantial inter-observer agreement for the diagnosis of SLAP lesions • MR arthrography is regarded as the definitive method of shoulder imaging • Different MR sequences are evolving for SLAP lesions • 3D TSE-SPACE demonstrated comparable overall accuracy to 2D TSE for SLAP lesions • But more false-negative interpretations occurred using 3D TSE-SPACE • Further technical improvement is necessary before 3D TSE-SPACE replaces 2D TSE sequences
- 1 July 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 199 (1) , W114-W122
Experimental Study of Artificially Induced Intramuscular Gossypiboma in Rabbits: Correlation of Sequential MRI Findings With Pathologic Findings
OBJECTIVE. The purpose of this study was to evaluate the sequential MRI findings of intramuscular gossypiboma and to correlate them with the pathologic findings in rabbits. MATERIALS AND METHODS. Sterile gauze was packed in the hamstring muscles of 12 rabbits, and sequential MR images were obtained 1, 2, and 4 weeks and 2, 6, and 12 months after gauze insertion. Two rabbits were sacrificed at each time point. Their pathologic findings were compared with the MRI findings on each date. RESULTS. At the acute stage, the gossypibomas appeared as areas of heterogeneous low signal intensity on T2-weighted MR images with inflammatory change around the gossypiboma. In the subacute stage, the gossypibomas appeared as areas of peripheral low and central high signal intensity with wavy stripes of low signal intensity on T2-weighted images. On contrast-enhanced fat-suppressed T1-weighted images, the peripheral enhancement of the masses advanced toward the center of the mass as the fibrocollagenization between the gauze bundles progressed centrally. In the chronic stage, on contrast-enhanced fat-suppressed T1-weighted images, central advancement of the peripheral enhancement occurred according to the maturation of the fibrocollagenization. Calcifications around individual gauze fibers were observed 6–12 months after gauze insertion. CONCLUSION. On sequential contrast-enhanced fat-suppressed T1-weighted images of rabbits, intramuscular gossypiboma exhibited a chronologic centripetal enhancement pattern for 1 year mainly owing to concentric progression of fibrocollagenization between gauze bundles toward the center of the mass.
- 1 July 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 199 (1) , W114-W122
Experimental Study of Artificially Induced Intramuscular Gossypiboma in Rabbits: Correlation of Sequential MRI Findings With Pathologic Findings
OBJECTIVE. The purpose of this study was to evaluate the sequential MRI findings of intramuscular gossypiboma and to correlate them with the pathologic findings in rabbits. MATERIALS AND METHODS. Sterile gauze was packed in the hamstring muscles of 12 rabbits, and sequential MR images were obtained 1, 2, and 4 weeks and 2, 6, and 12 months after gauze insertion. Two rabbits were sacrificed at each time point. Their pathologic findings were compared with the MRI findings on each date. RESULTS. At the acute stage, the gossypibomas appeared as areas of heterogeneous low signal intensity on T2-weighted MR images with inflammatory change around the gossypiboma. In the subacute stage, the gossypibomas appeared as areas of peripheral low and central high signal intensity with wavy stripes of low signal intensity on T2-weighted images. On contrast-enhanced fat-suppressed T1-weighted images, the peripheral enhancement of the masses advanced toward the center of the mass as the fibrocollagenization between the gauze bundles progressed centrally. In the chronic stage, on contrast-enhanced fat-suppressed T1-weighted images, central advancement of the peripheral enhancement occurred according to the maturation of the fibrocollagenization. Calcifications around individual gauze fibers were observed 6–12 months after gauze insertion. CONCLUSION. On sequential contrast-enhanced fat-suppressed T1-weighted images of rabbits, intramuscular gossypiboma exhibited a chronologic centripetal enhancement pattern for 1 year mainly owing to concentric progression of fibrocollagenization between gauze bundles toward the center of the mass.
- 10 February 2012
- Published by Springer Nature in Skeletal Radiology
- Vol. 41 (11) , 1401-1410
Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences
To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0 T. The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0 T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement (κ) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone. There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE. Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears.
- 10 February 2012
- Published by Springer Nature in Skeletal Radiology
- Vol. 41 (11) , 1401-1410
Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences
To assess the diagnostic performance of shoulder MR arthrography with 3D isotropic fat-suppressed (FS) turbo spin-echo sequence (TSE-SPACE) for supraspinatus tendon tears in comparison with 2D conventional sequences at 3.0 T. The study was HIPAA-compliant and approved by the institutional review board with a waiver of informed consent. Eighty-seven arthroscopically confirmed patients who underwent 3.0 T shoulder MR arthrography with 2D sequences and 3D TSE-SPACE were included in a consecutive fashion from March 2009 to February 2010. Two reviewers independently analyzed 2D sequences and 3D TSE-SPACE. Sensitivity, specificity, accuracy, and interobserver agreement (κ) were compared between 2D sequences and 3D TSE-SPACE for full-thickness and partial-thickness supraspinatus tendon tears together and for partial-thickness supraspinatus tendon tears alone. There were 33 full-thickness tears and 28 partial-thickness tears of supraspinatus tendons. For full-thickness and partial-thickness supraspinatus tendon tears together, the mean sensitivity, specificity, and accuracy of both readers were 96, 92, and 94% on 2D sequences and 91, 84, and 89% on 3D TSE-SPACE. For partial-thickness supraspinatus tendon tears alone, the mean sensitivity, specificity, and accuracy were 95, 92, and 94% on 2D sequences and 84, 85, and 84% on 3D TSE-SPACE. There was no statistical difference between 2D sequences and 3D TSE-SPACE. Interobserver agreements were almost perfect on 2D conventional sequences and substantial on 3D TSE-SPACE. Compared with 2D conventional sequences, MR arthrography using 3D TSE-SPACE was comparable for diagnosing supraspinatus tendon tears despite limitations in detecting small partial-thickness tears and in discriminating between full-thickness and deep partial-thickness tears.
- 1 February 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 198 (2) , W173-W180
Meniscal Tear Configurations: Categorization With 3D Isotropic Turbo Spin-Echo MRI Compared With Conventional MRI at 3 T
OBJECTIVE. The purpose of our study was to compare the accuracy of 3D fat-suppressed isotropic turbo spin-echo (TSE) sequences using sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) with 2D conventional MRI at 3 T in determining meniscal tear types. MATERIALS AND METHODS. Sixty-nine patients with arthroscopically confirmed meniscal tears underwent MRI with 2D sequences and 3D TSE SPACE. Images were retrospectively analyzed by two reviewers and correlated with arthroscopic findings. Meniscal tears were classified into one of eight types: horizontal, longitudinal, radial, root, flap, oblique, complex, and bucket-handle. For every type of tear, sensitivity, specificity, and interobserver agreement were calculated. RESULTS. Mean sensitivities and specificities on 3D TSE SPACE versus 2D sequences were as follows: for radial tears, 77% and 93% versus 68% and 90%; for flap tears, 73% and 96% versus 54% and 85%; for horizontal tears, 85% and 91% versus 78% versus 87%; for longitudinal tears, 50% and 97% versus 72% and 96%; and for root tears, 88% and 99% versus 81% and 99%. The specificity for flap tears was statistically higher on 3D TSE SPACE than 2D sequences. Interobserver agreements were higher on 3D TSE SPACE than 2D sequences for radial, flap, and longitudinal tears. CONCLUSION. In categorizing meniscal tears, 3D TSE SPACE has higher specificity for flap tears than 2D conventional sequences. However, there is no significant difference between 2D conventional sequences and 3D TSE SPACE except for flap tears.
- 1 February 2012
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 198 (2) , W173-W180
Meniscal Tear Configurations: Categorization With 3D Isotropic Turbo Spin-Echo MRI Compared With Conventional MRI at 3 T
OBJECTIVE. The purpose of our study was to compare the accuracy of 3D fat-suppressed isotropic turbo spin-echo (TSE) sequences using sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) with 2D conventional MRI at 3 T in determining meniscal tear types. MATERIALS AND METHODS. Sixty-nine patients with arthroscopically confirmed meniscal tears underwent MRI with 2D sequences and 3D TSE SPACE. Images were retrospectively analyzed by two reviewers and correlated with arthroscopic findings. Meniscal tears were classified into one of eight types: horizontal, longitudinal, radial, root, flap, oblique, complex, and bucket-handle. For every type of tear, sensitivity, specificity, and interobserver agreement were calculated. RESULTS. Mean sensitivities and specificities on 3D TSE SPACE versus 2D sequences were as follows: for radial tears, 77% and 93% versus 68% and 90%; for flap tears, 73% and 96% versus 54% and 85%; for horizontal tears, 85% and 91% versus 78% versus 87%; for longitudinal tears, 50% and 97% versus 72% and 96%; and for root tears, 88% and 99% versus 81% and 99%. The specificity for flap tears was statistically higher on 3D TSE SPACE than 2D sequences. Interobserver agreements were higher on 3D TSE SPACE than 2D sequences for radial, flap, and longitudinal tears. CONCLUSION. In categorizing meniscal tears, 3D TSE SPACE has higher specificity for flap tears than 2D conventional sequences. However, there is no significant difference between 2D conventional sequences and 3D TSE SPACE except for flap tears.
- 1 October 2011
- Published by SAGE Publications in Acta Radiologica
- Vol. 52 (8) , 875-880
MRI of chondromyxoid fibroma
Background: Chondromyxoid fibroma is a rare benign primary bone tumor of cartilage. Despite a characteristic radiographic appearance, chondromyxoid fibroma with atypical radiographic findings may mimic more common tumors. Purpose: To describe the MR findings of chondromyxoid fibroma. Material and Methods: MR images of 19 histopathologically confirmed chondromyxoid fibromas were retrospectively analyzed for signal intensity, periosteal reaction, adjacent abnormal bone marrow and soft tissue signal, and patterns of contrast enhancement. Results: All cases of chondromyxoid fibroma showed hypointense to intermediate signal intensity and internal hyperintense foci were observed in seven (37%) cases on T1-weighted images. On T2-weighted images, all lesions were hyperintense: peripheral intermediate signal band with central hyperintense signal in 11 (58%) of 19 lesions, whereas diffusely hyperintense with heterogeneous pattern in eight (42%). Periosteal reaction was observed in 11 (58%) of 19 cases. Adjacent abnormal bone marrow or soft tissue signal was observed in 12 (63%) or 14 (74%) of 19 cases, respectively. On contrast-enhanced T1-weighted images, peripheral nodular enhancement was observed in 69% (11/16) and diffuse contrast enhancement was observed in 31% (5/16) with homogeneous ( n = 3) or heterogeneous ( n = 2) patterns. Among the cases with peripheral nodular enhancement, the peripheral nodular enhancing portion generally corresponded to the peripheral intermediate signal band on T2-weighted images, although the peripheral enhancement was not as wide as a band of intermediate signal intensity. On the other hand, the central non-enhancing portion generally corresponded to the central hyperintense signal intensity on T2-weighted images. Conclusion: The helpful features of chondromyxoid fibroma are the peripheral intermediate signal band and central hyperintense signal on T2-weighted images, generally corresponding to the peripheral nodular enhancement and central non-enhancing portion on contrast-enhanced T1-weighted images, respectively.
- 1 October 2011
- Published by SAGE Publications in Acta Radiologica
- Vol. 52 (8) , 875-880
MRI of chondromyxoid fibroma
Background: Chondromyxoid fibroma is a rare benign primary bone tumor of cartilage. Despite a characteristic radiographic appearance, chondromyxoid fibroma with atypical radiographic findings may mimic more common tumors. Purpose: To describe the MR findings of chondromyxoid fibroma. Material and Methods: MR images of 19 histopathologically confirmed chondromyxoid fibromas were retrospectively analyzed for signal intensity, periosteal reaction, adjacent abnormal bone marrow and soft tissue signal, and patterns of contrast enhancement. Results: All cases of chondromyxoid fibroma showed hypointense to intermediate signal intensity and internal hyperintense foci were observed in seven (37%) cases on T1-weighted images. On T2-weighted images, all lesions were hyperintense: peripheral intermediate signal band with central hyperintense signal in 11 (58%) of 19 lesions, whereas diffusely hyperintense with heterogeneous pattern in eight (42%). Periosteal reaction was observed in 11 (58%) of 19 cases. Adjacent abnormal bone marrow or soft tissue signal was observed in 12 (63%) or 14 (74%) of 19 cases, respectively. On contrast-enhanced T1-weighted images, peripheral nodular enhancement was observed in 69% (11/16) and diffuse contrast enhancement was observed in 31% (5/16) with homogeneous ( n = 3) or heterogeneous ( n = 2) patterns. Among the cases with peripheral nodular enhancement, the peripheral nodular enhancing portion generally corresponded to the peripheral intermediate signal band on T2-weighted images, although the peripheral enhancement was not as wide as a band of intermediate signal intensity. On the other hand, the central non-enhancing portion generally corresponded to the central hyperintense signal intensity on T2-weighted images. Conclusion: The helpful features of chondromyxoid fibroma are the peripheral intermediate signal band and central hyperintense signal on T2-weighted images, generally corresponding to the peripheral nodular enhancement and central non-enhancing portion on contrast-enhanced T1-weighted images, respectively.