JLJoanne Luider

Joanne Luider

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joanne Luider has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reovirus modulates autophagy during oncolysis of multiple myeloma

    by Chandini M. Thirukkumaran, Zhong Qiao Shi, Joanne Luider, Karen Kopciuk, He Gao, Nizar Bahlis, Paola Neri, Mark Pho, Doug Stewart, Adnan Mansoor, et al.

    Multiple myeloma (MM) is a clonal plasma cell malignancy that accounts for 10–15% of newly diagnosed hematological cancers. Although significant advances have been made in the treatment of MM the disease still remains incurable. The oncolytic potential of reovirus has previously been demonstrated by others and us and is currently in phase III clinical trials for solid tumors. In addition a phase I clinical trial has recently been initiated for MM. Despite the clinical activity, the mechanism(s) of cell death caused by reovirus in MM is yet not well elucidated. A comprehensive understanding of reovirus-mediated histology-specific cell death mechanisms is imperative if this therapeutic is to become a standard of care for patients. Previously we have shown that reovirus-mediated cell death of breast and prostate cancer is orchestrated via apoptosis. The present study demonstrates for the first time that in addition to inducing apoptosis reovirus also upregulates autophagy during oncolysis of MM.


  • Open Access

    Expression of MS4A and TMEM176 Genes in Human B Lymphocytes

    by Jonathan Zuccolo, Lili Deng, Tammy L. Unruh, Ratna Sanyal, Jeremy A. Bau, Jan Storek, Douglas J. Demetrick, Joanne M. Luider, Iwona A. Auer-Grzesiak, Adnan Mansoor, et al.

    The MS4A gene family in humans includes CD20 and at least 15 other genes. CD20 exists as homo-oligomers in the plasma membrane, however different MS4A proteins expressed in the same cell may hetero-oligomerize. Given the importance of CD20 in B-cell function and as a therapeutic target, we sought to explore the potential for CD20 hetero-oligomerization with other MS4A proteins. We investigated expression in primary human B-cells of the four MS4A genes previously shown to be expressed in human B-cell lines (MS4A4A, MS4A6A, MS4A7, MS4A8B), as well as two genes comprising the closely related TMEM176 gene family, with a view to identifying candidates for future investigation at the protein level. TMEM176A and TMEM176B transcripts were either not detected, or were detected at relatively low levels in a minority of donor B-cell samples. MS4A4A and MS4A8B transcripts were not detected in any normal B-cell sample. MS4A6A and MS4A7 transcripts were detected at low levels in most samples, however the corresponding proteins were not at the plasma membrane when expressed as GFP conjugates in BJAB cells. We also examined expression of these genes in chronic lymphocytic leukemia (CLL), and found that it was similar to normal B-cells with two exceptions. First, whereas MS4A4A expression was undetected in normal B-cells, it was expressed in 1/14 CLL samples. Second, compared to expression levels in normal B-cells, MS4A6A transcripts were elevated in 4/14 CLL samples. In summary, none of the MS4A/TMEM176 genes tested was expressed at high levels in normal or in most CLL B-cells. MS4A6A and MS4A7 were expressed at low levels in most B-cell samples, however the corresponding proteins may not be positioned at the plasma membrane. Altogether, these data suggest that CD20 normally does not form hetero-oligomers with other MS4A proteins and that there are unlikely to be other MS4A proteins in CLL that might provide useful alternate therapeutic targets.


  • Open Access

    Allergen-specific T cell quantity in blood is higher in allergic compared to nonallergic individuals

    by Aito Ueno-Yamanouchi, Faisal M Khan, Bazir Serushago, Tom Bowen, Cathy Lu, Joanne Luider, Jan Storek

    Background: Allergen-specific IgE production is a hallmark of allergic asthma/rhinitis/eczema. Theoretically this could be due to a high number of allergen-specific B cells or allergen-specific T cells helping allergen-specific B cells differentiate into IgE-producing plasma cells. Here, we determined whether the number of allergen-specific B cells or T helper (Th) cells is higher in allergic individuals compared to nonallergic individuals.Methods: A total of 52 allergic individuals and 32 nonallergic individuals were studied. The allergen-specific B and Th cells were enumerated by culturing CFSE-loaded blood mononuclear cells for 7-days with allergen (cat, Timothy or birch), and determining the number of proliferating B or Th cells (diluting CFSE) by flow cytometry. Allergen-specific IgE concentration was determined by fluorescent enzymoimmunoassay (FEIA).Results: The quantities of proliferating Th cells but not proliferating B cells specific for cat, Timothy and birch were significantly higher in cat-, Timothy- and birch-allergic individuals compared to nonallergic individuals. The titer of allergen-specific IgE showed significant correlation with allergen-specific Th cells and not with allergen-specific B cells for all 3 allergens.Conclusions: A high number of allergen-specific proliferating Th cells, but not proliferating B cells, may play a role in the pathogenesis of allergic asthma/rhinitis/eczema.


  • Impact of the New Beckman Coulter Cytomics FC 500 5-Color Flow Cytometer on a Regional Flow Cytometry Clinical Laboratory Service

    by J. Luider, M. Cyfra, P. Johnson, I. Auer

    Calgary Laboratory Services (CLS) in Alberta, Canada, is the regional reference laboratory providing flow cytometry services for southern Alberta and southeastern British Columbia. As a busy reference flow laboratory we provide flow cytometry immunophenotyping for investigation and diagnosis of acute and chronic leukemias, lymphomas, immunodeficiencies, neuroblastoma, platelet disorders, and interstitial lung disease (ILD). Because of increasing workload and the continual effort to improve the service to our health care providers, CLS invested in the new Beckman Coulter Cytomics FC 500 5-color flow cytometer. In addition to time and labor savings due to reduced maintenance and operating system design, this new flow cytometer automates many of the previous manual steps involved in quality control and flow cytometric analysis. It also incorporates 2 lasers and is capable of measuring 5-color antibody combinations in a single tube, enabling us to reduce the number of tubes and overall costs, giving us better gating options for minimal residual disease analysis. We present the first published evaluation, an assessment of the overall productivity and cost impact of the new state-of-the-art Cytomics FC 500 flow cytometer. Implementation of the Cytomics FC 500 has resulted in a 20% reduction in reagent costs and shorter turnaround time for analysis and diagnosis. This instrument has allowed us to reduce our acute leukemia panel from 17 to 13 tubes, our lymphoma panel from 13 to 7 tubes, and our ILD panel from 4 to 2 tubes. The availability of 2 lasers provides more flexibility in choosing antibodies and conjugates to customize immunophenotyping panels. It also allows us to use the DRAQ5 dye and simultaneously analyze the immunophenotype and DNA content of cells with very little compensation. Many of the arduous, time-consuming flow operator tasks often associated with previous generation flow cytometry instruments, such as color compensation, list mode analysis, sample repeats, and interpretations, have been substantially reduced with the Cytomics FC 500 5-color flow cytometer. In conclusion the Cytomics FC 500 5-color flow cytometer is a major advance in flow cytometry instrumentation and has reduced our overall reagent costs by 20%, provided better information and speedier turnaround time to our health care professionals. It is an ideal flow cytometer for any busy clinical or research flow cytometry service.