Young Hwan Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Young Hwan Kim has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
See Hyung Kim
Department of Radiology, Dongsan Medical Center, Keimyung University College of Medicine, 56 Dalseong-Ro, Jun-Gu, Daegu, 700-712, Korea
6 shared publicationsYong Joo Kim
Department of Radiology, Andong General Hospital, Gyeongsangbuk-do 760-410, Korea
6 shared publicationsJin Soo Choi
Department of Diagnostic Radiology, Dongsan Medical Center, Keimyung University College of Medicine, Korea
5 shared publications- Seung Hyun Cho
Department of Radiology, Kyungpook National University Chilgok Hospital, School of Medicine, Kyungpook National University, Daegu, Republic of Korea
4 shared publications Chang Won Kim
Department of Radiology, Pusan National University College of Medicine, Busan, Korea
3 shared publicationsEun Jung An
Department of Radiology, Dongsan Medical Center, Keimyung University College of Medicine, Daegu, Korea
3 shared publications
Latest Publications
- 1 October 2017
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 209 (4) , 800-805
Validation of Prostate Imaging Reporting and Data System Version 2 Using an MRI-Ultrasound Fusion Biopsy in Prostate Cancer Diagnosis
OBJECTIVE. The purpose of our study was to prospectively assess Prostate Imaging Reporting and Data System (PI-RADS) version 2 using an MRI-ultrasound fusion biopsy. SUBJECTS AND METHODS. This study included 295 consecutive patients with 478 lesions who underwent multiparametric MRI and subsequent MRI-ultrasound fusion biopsy between December 2014 and September 2016. Lesions were assessed by using an overall score of PI-RADS version 2. One radiologist assessed the presence or absence of clinically significant prostate cancer in the whole gland and in subgroups of the peripheral zone and transition zone by using cutoff values of ≥ 4 and ≥ 3. Histologic examination of MRI-ultrasound fusion biopsy specimens was used as the reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated to assess the utility of PI-RADS version 2 for the diagnosis of clinically significant prostate cancer. RESULTS. The overall PI-RADS version 2 scores showed an accuracy of 82.2% (393/478) for the whole gland, with a cutoff value of ≥ 4 granting sensitivity of 90.0% (90/100), specificity of 80.1% (303/378), PPV of 83.3% (90/108), and NPV of 81.8% (303/370). The overall scores showed accuracies of 84.7% (301/355) in the peripheral zone and 74.7% (92/123) in the transition zone. When we applied an arbitrary overall score of ≥ 3, accuracy was 68.6% (328/478), sensitivity was 94.6% (124/131), specificity was 58.7% (204/347), PPV was 51.6% (124/240), and NPV was 85.7% (204/238). CONCLUSION. PI-RADS version 2 has an overall good performance for the diagnosis of clinically significant prostate cancer.
- 1 October 2017
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 209 (4) , 800-805
Validation of Prostate Imaging Reporting and Data System Version 2 Using an MRI-Ultrasound Fusion Biopsy in Prostate Cancer Diagnosis
OBJECTIVE. The purpose of our study was to prospectively assess Prostate Imaging Reporting and Data System (PI-RADS) version 2 using an MRI-ultrasound fusion biopsy. SUBJECTS AND METHODS. This study included 295 consecutive patients with 478 lesions who underwent multiparametric MRI and subsequent MRI-ultrasound fusion biopsy between December 2014 and September 2016. Lesions were assessed by using an overall score of PI-RADS version 2. One radiologist assessed the presence or absence of clinically significant prostate cancer in the whole gland and in subgroups of the peripheral zone and transition zone by using cutoff values of ≥ 4 and ≥ 3. Histologic examination of MRI-ultrasound fusion biopsy specimens was used as the reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated to assess the utility of PI-RADS version 2 for the diagnosis of clinically significant prostate cancer. RESULTS. The overall PI-RADS version 2 scores showed an accuracy of 82.2% (393/478) for the whole gland, with a cutoff value of ≥ 4 granting sensitivity of 90.0% (90/100), specificity of 80.1% (303/378), PPV of 83.3% (90/108), and NPV of 81.8% (303/370). The overall scores showed accuracies of 84.7% (301/355) in the peripheral zone and 74.7% (92/123) in the transition zone. When we applied an arbitrary overall score of ≥ 3, accuracy was 68.6% (328/478), sensitivity was 94.6% (124/131), specificity was 58.7% (204/347), PPV was 51.6% (124/240), and NPV was 85.7% (204/238). CONCLUSION. PI-RADS version 2 has an overall good performance for the diagnosis of clinically significant prostate cancer.
- 1 September 2017
- Published by Elsevier in European Journal of Radiology
- Vol. 94, 154-159
Role of semi–quantitative dynamic contrast–enhanced MR imaging in characterization and grading of prostate cancer
- 1 September 2017
- Published by Elsevier in European Journal of Radiology
- Vol. 94, 154-159
Role of semi–quantitative dynamic contrast–enhanced MR imaging in characterization and grading of prostate cancer
- 1 May 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 279 (2) , 471-480
Detection of Urothelial Carcinoma: Comparison of Reduced-Dose Iterative Reconstruction with Standard-Dose Filtered Back Projection
Purpose To prospectively assess radiation dose, image quality, and diagnostic performance of computed tomography (CT) urography for detection of urothelial carcinomas by performing reduced-dose scanning with iterative reconstruction (IR) compared with standard-dose scanning with filtered back projection (FBP). Materials and Methods The institutional review board approved the study with written informed patient consent. In total, 2163 patients at high risk for urothelial carcinomas randomly underwent standard-dose scanning with FBP (protocol A, 120 kVp for >80 kg body weight; protocol B, 100 kVp for 50–80 kg body weight) or reduced-dose scanning with IR (protocol C, 100 kVp for >80 kg body weight; protocol D, 80 kVp for 50–80 kg body weight). Objective image quality (signal-to-noise ratio and contrast-to-noise ratio) between the two groups with same weight range was measured for various regions of interest. Subjective image quality (visual image noise, artifact, ureter depiction, and overall image quality) and diagnostic accuracy (per lesion and per patient) were assessed with three- and five-point scores, respectively. Results Size-specific dose estimate (protocol A vs protocol C, 24.2 mGy vs 19.2 mGy, respectively; protocol B vs protocol D,13.9 mGy vs 8.8 mGy, respectively) was significantly lower in reduced-dose scanning (P < .001 for both). There were significantly higher signal-to-noise and contrast-to-noise ratios in reduced-dose scanning, except for the abdominal aorta (P < .05 for all). There was no significant difference in subjective image quality, except for artifacts in protocols B and D (range, 4–5 vs 3–4; P < .05). Per-lesion diagnostic accuracy was 90.8% (89 of 98, protocol A), 91.3% (105 of 115, protocol B), 92.9% (79 of 85, protocol C), and 88.8% (111 of 125, protocol D). Conclusion Reduced-dose scanning with IR showed dose reduction and no significant difference of image quality in detection of urothelial carcinomas, except for some artifacts in 80-kVp scanning. © RSNA, 2015
- 1 May 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 279 (2) , 471-480
Detection of Urothelial Carcinoma: Comparison of Reduced-Dose Iterative Reconstruction with Standard-Dose Filtered Back Projection
Purpose To prospectively assess radiation dose, image quality, and diagnostic performance of computed tomography (CT) urography for detection of urothelial carcinomas by performing reduced-dose scanning with iterative reconstruction (IR) compared with standard-dose scanning with filtered back projection (FBP). Materials and Methods The institutional review board approved the study with written informed patient consent. In total, 2163 patients at high risk for urothelial carcinomas randomly underwent standard-dose scanning with FBP (protocol A, 120 kVp for >80 kg body weight; protocol B, 100 kVp for 50–80 kg body weight) or reduced-dose scanning with IR (protocol C, 100 kVp for >80 kg body weight; protocol D, 80 kVp for 50–80 kg body weight). Objective image quality (signal-to-noise ratio and contrast-to-noise ratio) between the two groups with same weight range was measured for various regions of interest. Subjective image quality (visual image noise, artifact, ureter depiction, and overall image quality) and diagnostic accuracy (per lesion and per patient) were assessed with three- and five-point scores, respectively. Results Size-specific dose estimate (protocol A vs protocol C, 24.2 mGy vs 19.2 mGy, respectively; protocol B vs protocol D,13.9 mGy vs 8.8 mGy, respectively) was significantly lower in reduced-dose scanning (P < .001 for both). There were significantly higher signal-to-noise and contrast-to-noise ratios in reduced-dose scanning, except for the abdominal aorta (P < .05 for all). There was no significant difference in subjective image quality, except for artifacts in protocols B and D (range, 4–5 vs 3–4; P < .05). Per-lesion diagnostic accuracy was 90.8% (89 of 98, protocol A), 91.3% (105 of 115, protocol B), 92.9% (79 of 85, protocol C), and 88.8% (111 of 125, protocol D). Conclusion Reduced-dose scanning with IR showed dose reduction and no significant difference of image quality in detection of urothelial carcinomas, except for some artifacts in 80-kVp scanning. © RSNA, 2015
- 12 January 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (6) , 840-846
Comparison of Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Using Ethanolamine Oleate (EO), BRTO Using Sodium Tetradecyl Sulfate (STS) Foam and Vascular Plug-Assisted Retrograde Transvenous Obliteration (PARTO)
To compare the clinical outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) using ethanolamine oleate (EO), BRTO using sodium tetradecyl sulfate (STS) foam, and vascular plug-assisted retrograde transvenous obliteration (PARTO). From April 2004 to February 2015, ninety-five patients underwent retrograde transvenous obliteration for gastric varices were analyzed retrospectively. BRTO with EO was performed in 49 patients, BRTO with STS foam in 25, and PARTO in 21. Among them, we obtained follow-up data in 70 patients. Recurrence of gastric varices was evaluated by follow-up endoscopy or CT. Medical records were reviewed for the clinical efficacy. Statistical analyses were performed by Kaplan–Meier method, Chi-square, Fisher’s, and Kruskal–Wallis tests. Technical and clinical success was 94.7 %. As major complications, a hemoglobinuria and a death due to disseminated intravascular coagulation (DIC) were occurred in two patients with BRTO using EO. Recurrence occurred more frequently in PARTO group (P < 0.05). Recurrence occurred in three patients in BRTO using EO group and four patients in PARTO group with 3.2 and 32.8 % of each expected 1-year recurrence rates. There was no recurrence in BRTO using STS group. Abdominal pain occurred more frequently in BRTO using EO than BRTO using STS foam and PARTO (P < 0.05). Procedure time of PARTO was shorter than two conventional BRTOs (P < 0.05). BRTO using STS foam or PARTO is better than BRTO using EO for treatment of gastric varices in terms of complication or procedure time. However, PARTO showed frequent recurrence of gastric varices during the long-term follow-up rather than BRTO.
- 12 January 2016
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (6) , 840-846
Comparison of Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Using Ethanolamine Oleate (EO), BRTO Using Sodium Tetradecyl Sulfate (STS) Foam and Vascular Plug-Assisted Retrograde Transvenous Obliteration (PARTO)
To compare the clinical outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) using ethanolamine oleate (EO), BRTO using sodium tetradecyl sulfate (STS) foam, and vascular plug-assisted retrograde transvenous obliteration (PARTO). From April 2004 to February 2015, ninety-five patients underwent retrograde transvenous obliteration for gastric varices were analyzed retrospectively. BRTO with EO was performed in 49 patients, BRTO with STS foam in 25, and PARTO in 21. Among them, we obtained follow-up data in 70 patients. Recurrence of gastric varices was evaluated by follow-up endoscopy or CT. Medical records were reviewed for the clinical efficacy. Statistical analyses were performed by Kaplan–Meier method, Chi-square, Fisher’s, and Kruskal–Wallis tests. Technical and clinical success was 94.7 %. As major complications, a hemoglobinuria and a death due to disseminated intravascular coagulation (DIC) were occurred in two patients with BRTO using EO. Recurrence occurred more frequently in PARTO group (P < 0.05). Recurrence occurred in three patients in BRTO using EO group and four patients in PARTO group with 3.2 and 32.8 % of each expected 1-year recurrence rates. There was no recurrence in BRTO using STS group. Abdominal pain occurred more frequently in BRTO using EO than BRTO using STS foam and PARTO (P < 0.05). Procedure time of PARTO was shorter than two conventional BRTOs (P < 0.05). BRTO using STS foam or PARTO is better than BRTO using EO for treatment of gastric varices in terms of complication or procedure time. However, PARTO showed frequent recurrence of gastric varices during the long-term follow-up rather than BRTO.
- Open Access
- 1 January 2016
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 75 (4) , 233-262
Diagnosis and Treatment of Lower Extremity Deep Vein Thrombosis: Korean Practice Guidelines
Kim YH, et al. J Korean Soc Radiol. 2016 Oct;75(4):233-262. https://doi.org/10.3348/jksr.2016.75.4.233
- 1 January 2016
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 75 (4) , 233-262
Open AccessDiagnosis and Treatment of Lower Extremity Deep Vein Thrombosis: Korean Practice Guidelines
Kim YH, et al. J Korean Soc Radiol. 2016 Oct;75(4):233-262. https://doi.org/10.3348/jksr.2016.75.4.233
- Open Access
- 1 January 2015
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 16 (4) , 696-722
Korean Guidelines for Interventional Recanalization of Lower Extremity Arteries
Kim YH, et al. Korean J Radiol. 2015 Jul-Aug;16(4):696-722. https://doi.org/10.3348/kjr.2015.16.4.696
- 1 January 2015
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 16 (4) , 696-722
Open AccessKorean Guidelines for Interventional Recanalization of Lower Extremity Arteries
Kim YH, et al. Korean J Radiol. 2015 Jul-Aug;16(4):696-722. https://doi.org/10.3348/kjr.2015.16.4.696
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (1) , 25-31
Diagnostic Efficiency of Split-Bolus Dual-Energy Computed Tomography for Patients With Suspected Urinary Stones
The objective of this study was to evaluate the efficiency of virtual noncontrast image (VNCI) generated from dual-energy split-bolus computed tomographic urography (DE-SBCTU) for urinary stones detection. Three hundred fifty-six patients underwent true noncontrast image (TNCI) and DE-SBCTU. Two radiologists evaluated opacification scores of DE-SBCTU as well as iodine subtractions and image noise on VNCI. Diagnostic performance of the VNCI was evaluated using TNCI as a reference standard, according to diameter and image quality. The results were compared between patient groups with body mass index of less than 25 and 25 kg/m2 or greater. Agreements for opacification, iodine subtraction, and image noise between the radiologists were excellent, and there were no significant difference in the 2 patients groups. A total of 499 stones were detected on VNCI, with a sensitivity and diagnostic accuracy of 95.1% (468/492) and 92.9% (499/537). Mean (SD) diameter was significantly smaller on VNCI (3.6 [2.3] mm) than on TNCI (4.4 [2.0] mm) (P = 0.01). The stone diameter with false interpretation was less than 4 mm in 48 of 51 patients. The diameter and image quality on VNCI had no significant difference between the 2 patients groups. Virtual noncontrast image displays high accuracy for detecting urinary stones, regardless of body mass index.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (1) , 25-31
Diagnostic Efficiency of Split-Bolus Dual-Energy Computed Tomography for Patients With Suspected Urinary Stones
The objective of this study was to evaluate the efficiency of virtual noncontrast image (VNCI) generated from dual-energy split-bolus computed tomographic urography (DE-SBCTU) for urinary stones detection. Three hundred fifty-six patients underwent true noncontrast image (TNCI) and DE-SBCTU. Two radiologists evaluated opacification scores of DE-SBCTU as well as iodine subtractions and image noise on VNCI. Diagnostic performance of the VNCI was evaluated using TNCI as a reference standard, according to diameter and image quality. The results were compared between patient groups with body mass index of less than 25 and 25 kg/m2 or greater. Agreements for opacification, iodine subtraction, and image noise between the radiologists were excellent, and there were no significant difference in the 2 patients groups. A total of 499 stones were detected on VNCI, with a sensitivity and diagnostic accuracy of 95.1% (468/492) and 92.9% (499/537). Mean (SD) diameter was significantly smaller on VNCI (3.6 [2.3] mm) than on TNCI (4.4 [2.0] mm) (P = 0.01). The stone diameter with false interpretation was less than 4 mm in 48 of 51 patients. The diameter and image quality on VNCI had no significant difference between the 2 patients groups. Virtual noncontrast image displays high accuracy for detecting urinary stones, regardless of body mass index.
- 31 December 2014
- Published by Korean Society of Computer Information in Journal of the Korea Society of Computer and Information
- Vol. 19 (12) , 227-237
Development of Textile Fabrics Flexible Platform based Multiple Bio-Signal Central Monitoring System for Emergency Situational Awareness in High-Risk Working Environments
- 31 December 2014
- Published by Korean Society of Computer Information in Journal of the Korea Society of Computer and Information
- Vol. 19 (12) , 227-237
Development of Textile Fabrics Flexible Platform based Multiple Bio-Signal Central Monitoring System for Emergency Situational Awareness in High-Risk Working Environments
- Open Access
- 1 January 2014
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 71 (5) , 205-230
Guideline for Interventional Recanalization of Lower Extremity Artery
- 1 January 2014
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 71 (5) , 205-230
Open AccessGuideline for Interventional Recanalization of Lower Extremity Artery
- Open Access
- 1 January 2014
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 70 (3) , 201-204
Gastric Variceal Rebleeding by Aberrant Left Gastric Vein after Transjugular Intrahepatic Portosystemic Shunt: A Case Report
- 1 January 2014
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 70 (3) , 201-204
Open AccessGastric Variceal Rebleeding by Aberrant Left Gastric Vein after Transjugular Intrahepatic Portosystemic Shunt: A Case Report