Claudio Pollo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Claudio Pollo has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Nowacki
Department of Neurosurgery, Inselspital, University Hospital Bern, Bern, Switzerland.
2 shared publications Michael Schüpbach
Department of Neurology, Inselspital, University Hospital Bern, and University of Bern, Bern, Switzerland
2 shared publicationsAlain Kaelin-Lang
Department of Neurology, Bern University Hospital, Inselspital, Bern, Switzerland
1 shared publication- Alain Kaelin-Lang
Neurology Department, Neurocenter of Southern Switzerland, Ente Ospedaliero Cantonale, Lugano, Switzerland
1 shared publication Andreas Raabe
Department of Neurosurgery, Bern University Hospital, Inselspital, Bern, Switzerland
1 shared publication- Andres M. Lozano
University Health Network and University of Toronto
1 shared publication
Latest Publications
- Open Access
- 13 October 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 163 (7) , 1965-1968
Stereotactic posterior midline approach under direct microscopic view for biopsy of medulla oblongata tumors: technical considerations
Background: Open and stereotactic transfrontal or transcerebellar approaches have been used to biopsy brainstem lesions. Method: In this report, a stereotactic posterior and midline approach to the distal medulla oblongata under microscopic view is described. The potential advantages and limitations are discussed, especially bilateral damage of the X nerve nuclei. Conclusion: This approach should be considered for biopsy of distal and posterior lesions. We strongly recommend the use of direct microscopic view to identify the medullary vessels, confirm the midline entry point, and avoid potential shift of the medulla. Further experience is needed to confirm safety and success rate of this approach.
- 13 October 2020
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 163 (7) , 1965-1968
Open AccessStereotactic posterior midline approach under direct microscopic view for biopsy of medulla oblongata tumors: technical considerations
Background: Open and stereotactic transfrontal or transcerebellar approaches have been used to biopsy brainstem lesions. Method: In this report, a stereotactic posterior and midline approach to the distal medulla oblongata under microscopic view is described. The potential advantages and limitations are discussed, especially bilateral damage of the X nerve nuclei. Conclusion: This approach should be considered for biopsy of distal and posterior lesions. We strongly recommend the use of direct microscopic view to identify the medullary vessels, confirm the midline entry point, and avoid potential shift of the medulla. Further experience is needed to confirm safety and success rate of this approach.
- Open Access
- 14 September 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (9) , e0137868
Using MDEFT MRI Sequences to Target the GPi in DBS Surgery
Recent advances in different MRI sequences have enabled direct visualization and targeting of the Globus pallidus internus (GPi) for DBS surgery. Modified Driven Equilibrium Fourier Transform (MDEFT) MRI sequences provide high spatial resolution and an excellent contrast of the basal ganglia with low distortion. In this study, we investigate if MDEFT sequences yield accurate and reliable targeting of the GPi and compare direct targeting based on MDEFT sequences with atlas-based targeting. 13 consecutive patients considered for bilateral GPi-DBS for dystonia or PD were included in this study. Preoperative targeting of the GPi was performed visually based on MDEFT sequences as well as by using standard atlas coordinates. Postoperative CT imaging was performed to calculate the location of the implanted leads as well as the active electrode(s). The coordinates of both visual and atlas based targets were compared. The stereotactic coordinates of the lead and active electrode(s) were calculated and projected on the segmented GPi. On MDEFT sequences the GPi was well demarcated in most patients. Compared to atlas-based planning the mean target coordinates were located significantly more posterior. Subgroup analysis showed a significant difference in the lateral coordinate between dystonia (LAT = 19.33 ± 0.90) and PD patients (LAT = 20.67 ± 1.69). Projected on the segmented preoperative GPi the active contacts of the DBS electrode in both dystonia and PD patients were located in the inferior and posterior part of the structure corresponding to the motor part of the GPi. MDEFT MRI sequences provide high spatial resolution and an excellent contrast enabling precise identification and direct visual targeting of the GPi. Compared to atlas-based targeting, it resulted in a significantly different mean location of our target. Furthermore, we observed a significant variability of the target among the PD and dystonia subpopulation suggesting accurate targeting for each individual patient.
- 14 September 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (9) , e0137868
Open AccessUsing MDEFT MRI Sequences to Target the GPi in DBS Surgery
Recent advances in different MRI sequences have enabled direct visualization and targeting of the Globus pallidus internus (GPi) for DBS surgery. Modified Driven Equilibrium Fourier Transform (MDEFT) MRI sequences provide high spatial resolution and an excellent contrast of the basal ganglia with low distortion. In this study, we investigate if MDEFT sequences yield accurate and reliable targeting of the GPi and compare direct targeting based on MDEFT sequences with atlas-based targeting. 13 consecutive patients considered for bilateral GPi-DBS for dystonia or PD were included in this study. Preoperative targeting of the GPi was performed visually based on MDEFT sequences as well as by using standard atlas coordinates. Postoperative CT imaging was performed to calculate the location of the implanted leads as well as the active electrode(s). The coordinates of both visual and atlas based targets were compared. The stereotactic coordinates of the lead and active electrode(s) were calculated and projected on the segmented GPi. On MDEFT sequences the GPi was well demarcated in most patients. Compared to atlas-based planning the mean target coordinates were located significantly more posterior. Subgroup analysis showed a significant difference in the lateral coordinate between dystonia (LAT = 19.33 ± 0.90) and PD patients (LAT = 20.67 ± 1.69). Projected on the segmented preoperative GPi the active contacts of the DBS electrode in both dystonia and PD patients were located in the inferior and posterior part of the structure corresponding to the motor part of the GPi. MDEFT MRI sequences provide high spatial resolution and an excellent contrast enabling precise identification and direct visual targeting of the GPi. Compared to atlas-based targeting, it resulted in a significantly different mean location of our target. Furthermore, we observed a significant variability of the target among the PD and dystonia subpopulation suggesting accurate targeting for each individual patient.
- 1 September 2014
- Published by Elsevier in Parkinsonism & Related Disorders
- Vol. 20 (9) , 1015-1017
Bladder function in patients with dystonia undergoing deep brain stimulation
- 1 September 2014
- Published by Elsevier in Parkinsonism & Related Disorders
- Vol. 20 (9) , 1015-1017
Bladder function in patients with dystonia undergoing deep brain stimulation
- Top Cited Papers
- 19 May 2014
- Published by Oxford University Press (OUP) in Brain
- Vol. 137 (7) , 2015-2026
Directional deep brain stimulation: an intraoperative double-blind pilot study
Deep brain stimulation of different targets has been shown to drastically improve symptoms of a variety of neurological conditions. However, the occurrence of disabling side effects may limit the ability to deliver adequate amounts of current necessary to reach the maximal benefit. Computed models have suggested that reduction in electrode size and the ability to provide directional stimulation could increase the efficacy of such therapies. This has never been demonstrated in humans. In the present study, we assess the effect of directional stimulation compared to omnidirectional stimulation. Three different directions of stimulation as well as omnidirectional stimulation were tested intraoperatively in the subthalamic nucleus of 11 patients with Parkinson’s disease and in the nucleus ventralis intermedius of two other subjects with essential tremor. At the trajectory chosen for implantation of the definitive electrode, we assessed the current threshold window between positive and side effects, defined as the therapeutic window. A computed finite element model was used to compare the volume of tissue activated when one directional electrode was stimulated, or in case of omnidirectional stimulation. All but one patient showed a benefit of directional stimulation compared to omnidirectional. A best direction of stimulation was observed in all the patients. The therapeutic window in the best direction was wider than the second best direction ( P = 0.003) and wider than the third best direction ( P = 0.002). Compared to omnidirectional direction, the therapeutic window in the best direction was 41.3% wider ( P = 0.037). The current threshold producing meaningful therapeutic effect in the best direction was 0.67 mA (0.3–1.0 mA) and was 43% lower than in omnidirectional stimulation ( P = 0.002). No complication as a result of insertion of the directional electrode or during testing was encountered. The computed model revealed a volume of tissue activated of 10.5 mm3 in omnidirectional mode, compared with 4.2 mm3 when only one electrode was used. Directional deep brain stimulation with a reduced electrode size applied intraoperatively in the subthalamic nucleus as well as in the nucleus ventralis intermedius of the thalamus significantly widened the therapeutic window and lowered the current needed for beneficial effects, compared to omnidirectional stimulation. The observed side effects related to direction of stimulation were consistent with the anatomical location of surrounding structures. This new approach opens the door to an improved deep brain stimulation therapy. Chronic implantation is further needed to confirm these findings. * Abbreviation : DBS : deep brain stimulation
- 19 May 2014
- Published by Oxford University Press (OUP) in Brain
- Vol. 137 (7) , 2015-2026
Top Cited PapersDirectional deep brain stimulation: an intraoperative double-blind pilot study
Deep brain stimulation of different targets has been shown to drastically improve symptoms of a variety of neurological conditions. However, the occurrence of disabling side effects may limit the ability to deliver adequate amounts of current necessary to reach the maximal benefit. Computed models have suggested that reduction in electrode size and the ability to provide directional stimulation could increase the efficacy of such therapies. This has never been demonstrated in humans. In the present study, we assess the effect of directional stimulation compared to omnidirectional stimulation. Three different directions of stimulation as well as omnidirectional stimulation were tested intraoperatively in the subthalamic nucleus of 11 patients with Parkinson’s disease and in the nucleus ventralis intermedius of two other subjects with essential tremor. At the trajectory chosen for implantation of the definitive electrode, we assessed the current threshold window between positive and side effects, defined as the therapeutic window. A computed finite element model was used to compare the volume of tissue activated when one directional electrode was stimulated, or in case of omnidirectional stimulation. All but one patient showed a benefit of directional stimulation compared to omnidirectional. A best direction of stimulation was observed in all the patients. The therapeutic window in the best direction was wider than the second best direction ( P = 0.003) and wider than the third best direction ( P = 0.002). Compared to omnidirectional direction, the therapeutic window in the best direction was 41.3% wider ( P = 0.037). The current threshold producing meaningful therapeutic effect in the best direction was 0.67 mA (0.3–1.0 mA) and was 43% lower than in omnidirectional stimulation ( P = 0.002). No complication as a result of insertion of the directional electrode or during testing was encountered. The computed model revealed a volume of tissue activated of 10.5 mm3 in omnidirectional mode, compared with 4.2 mm3 when only one electrode was used. Directional deep brain stimulation with a reduced electrode size applied intraoperatively in the subthalamic nucleus as well as in the nucleus ventralis intermedius of the thalamus significantly widened the therapeutic window and lowered the current needed for beneficial effects, compared to omnidirectional stimulation. The observed side effects related to direction of stimulation were consistent with the anatomical location of surrounding structures. This new approach opens the door to an improved deep brain stimulation therapy. Chronic implantation is further needed to confirm these findings. * Abbreviation : DBS : deep brain stimulation
- 1 January 2014
- Published by Springer Nature
- p. 237-243
Stimulation cérébrale profonde dans le traitement de la douleur chronique
- 1 January 2014
- Published by Springer Nature
- p. 237-243
Stimulation cérébrale profonde dans le traitement de la douleur chronique
- 30 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 46 (12) , 4046-4051
Effect of Model Accuracy on the Result of Computed Current Densities in the Simulation of Transcranial Magnetic Stimulation
In this paper, we study the effects of model complexity on the accuracy of the results in the computer simulation of transcranial magnetic stimulation (TMS). The method has been extensively used in the last decade as a noninvasive technique to excite neurons in the brain by inducing weak electric currents in the tissue and proved to be a very promising alternative for currently invasive treatments in Parkinson's and Alzheimer's diseases. A detailed 3-D model of a human head has been developed by combining individual patient-based brain images and the public domain Visible Human data consisting of brain white/gray matter, CSF, skull, and muscles. The finite-element method (low-frequency Ansoft Maxwell 3D package) is used to simulate the interaction of time-varying magnetic fields with brain tissues and to compute the densities of induced currents in different areas. Models with different levels of tissue separation have been developed and tested under the same condition to investigate the effects of model complexity on the distribution of fields and induced currents inside different tissues.
- 30 September 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 46 (12) , 4046-4051
Effect of Model Accuracy on the Result of Computed Current Densities in the Simulation of Transcranial Magnetic Stimulation
In this paper, we study the effects of model complexity on the accuracy of the results in the computer simulation of transcranial magnetic stimulation (TMS). The method has been extensively used in the last decade as a noninvasive technique to excite neurons in the brain by inducing weak electric currents in the tissue and proved to be a very promising alternative for currently invasive treatments in Parkinson's and Alzheimer's diseases. A detailed 3-D model of a human head has been developed by combining individual patient-based brain images and the public domain Visible Human data consisting of brain white/gray matter, CSF, skull, and muscles. The finite-element method (low-frequency Ansoft Maxwell 3D package) is used to simulate the interaction of time-varying magnetic fields with brain tissues and to compute the densities of induced currents in different areas. Models with different levels of tissue separation have been developed and tested under the same condition to investigate the effects of model complexity on the distribution of fields and induced currents inside different tissues.