J. R. Buitenweg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
J. R. Buitenweg has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
E. Marani
2 shared publicationsW.L.C. Rutten
2 shared publications- E. Marani
Institute of BioMedical Technology, Department of Biomedical Engineering, Faculty of Electrical Engineering, University of Twente, Enschede, The Netherlands
1 shared publication E.M. Heide
Institute for Biomedical Technology (BMTI), Department EEMCS, Biomedical Signals and Systems Group, University of Twente, Enschede, The Netherlands
1 shared publicationJ. Ursum
1 shared publicationJ. W. van Nieuwkasteele
University of Twente
1 shared publication
Latest Publications
- 1 September 2006
- Published by Wiley in European journal of pain
- Vol. 10 (S1) , S72a-S72
268 INTENSITY MODULATION OF CUTANEOUS ELECTRICAL STIMULATION: EPS AND SUBJECTIVE RATINGS
- 1 September 2006
- Published by Wiley in European journal of pain
- Vol. 10 (S1) , S72a-S72
268 INTENSITY MODULATION OF CUTANEOUS ELECTRICAL STIMULATION: EPS AND SUBJECTIVE RATINGS
- 1 April 2002
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 115 (2) , 211-221
Extracellular detection of active membrane currents in the neuron–electrode interface
- 1 April 2002
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 115 (2) , 211-221
Extracellular detection of active membrane currents in the neuron–electrode interface
- 1 January 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 19 (6) , 46-52
Finite element modeling of the neuron-electrode interface
The electrical contact between an embedded microelectrode and a cultured neuron depends on the geometry of the neuron-electrode interface. The contact is improved when the electrode is covered, or sealed, completely by the neuron. In this article, the finite element method is proposed as a tool for modeling the electrical properties of the neuron-electrode interface. This method permits numerical solutions of volume conductor problems for a variety of geometries, without prior restriction of the current paths. Simulations are focused on the influence of the geometry on the transfer of an extracellularly applied stimulus current to the neuron and on the sealing resistance. A comparison is also made between finite element modeling and lumped circuit modeling. In conclusion, finite element analysis is a valuable tool for studying and optimizing the neuron-electrode contact.
- 1 January 2000
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 19 (6) , 46-52
Finite element modeling of the neuron-electrode interface
The electrical contact between an embedded microelectrode and a cultured neuron depends on the geometry of the neuron-electrode interface. The contact is improved when the electrode is covered, or sealed, completely by the neuron. In this article, the finite element method is proposed as a tool for modeling the electrical properties of the neuron-electrode interface. This method permits numerical solutions of volume conductor problems for a variety of geometries, without prior restriction of the current paths. Simulations are focused on the influence of the geometry on the transfer of an extracellularly applied stimulus current to the neuron and on the sealing resistance. A comparison is also made between finite element modeling and lumped circuit modeling. In conclusion, finite element analysis is a valuable tool for studying and optimizing the neuron-electrode contact.
- 1 September 1998
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 36 (5) , 630-637
Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy
Sealing resistance is highly significant with respect to the electrical neuronelectrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing resistance on the total impedance spectrum of a cell-electrode interface is modelled for complete coverage of the electrode by the cell. Sensitivity analysis demonstrates that the impedance spectrum is determined by four parameters: two electrode parameters, the sealing resistance and the shunt capacitance between the lead of the electrode and the culture medium. Experimental verification of the model is performed by simultaneous measurement of the impedance spectrum and electrode coverage. A good and unique fit between the simulated and measured impedance spectra was obtained by varying the two electrode parameters and the sealing resistance.
- 1 September 1998
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 36 (5) , 630-637
Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy
Sealing resistance is highly significant with respect to the electrical neuronelectrode contact because it decreases the stimulation threshold of neurons cultured on a planar micro-electrode array. A method is proposed for measurement of the sealing resistance using impedance spectroscopy. The effect of the sealing resistance on the total impedance spectrum of a cell-electrode interface is modelled for complete coverage of the electrode by the cell. Sensitivity analysis demonstrates that the impedance spectrum is determined by four parameters: two electrode parameters, the sealing resistance and the shunt capacitance between the lead of the electrode and the culture medium. Experimental verification of the model is performed by simultaneous measurement of the impedance spectrum and electrode coverage. A good and unique fit between the simulated and measured impedance spectra was obtained by varying the two electrode parameters and the sealing resistance.