Raneen Shehadeh Mashor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Raneen Shehadeh Mashor has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
David S. Rootman
Department of Ophthalmology, Toronto Western Hospital, University of Toronto, Toronto, Ontario, Canada
4 shared publicationsAllan R. Slomovic
3 shared publications- Igor Kaiserman
Care-Vision Laser Center, Tel Aviv, Israel
2 shared publications Irit Bahar
2 shared publicationsAlex Lichtinger
Department of Ophthalmology, Toronto Western Hospital, University of Toronto, Toronto, Ontario, Canada
1 shared publication- Allan R. Slomovic
Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada
1 shared publication
Latest Publications
- 1 March 2015
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 159 (3) , 415-418.e1
Changes in Macular Thickness After Descemet Stripping Automated Endothelial Keratoplasty
- 1 March 2015
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 159 (3) , 415-418.e1
Changes in Macular Thickness After Descemet Stripping Automated Endothelial Keratoplasty
- 1 April 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (4) , 390-395
Long-Term Outcomes of Femtosecond Laser–Assisted Mushroom Configuration Deep Anterior Lamellar Keratoplasty
Purpose: To review the long-term outcomes after femtosecond laser (FSL)–assisted mushroom configuration deep anterior lamellar keratoplasty (DALK). Methods: Noncomparative case series of 19 eyes from 19 patients who underwent FSL-assisted mushroom configuration DALK. Results: Data were available for 14 eyes at 1 month, for 14 at 3 months, for 16 at 6 months, for 10 at 9 months, and for 8 at 1 year. Preoperative mean best-corrected visual acuity was 20/108 (range: 20/30–20/400). At 3 months, the mean best-corrected visual acuity was 20/46 (range: 20/25–20/250), and at a mean final follow-up of 13 months (range: 6–29) it was 20/35 (range: 20/15–20/200). The greatest change in mean spherical equivalent was at 3 months [−2.29 diopters (D), range: −7.38 to +3.38 D; from −9.54 D, range: −20.00 to +3.38 D, preoperatively]. There was 56% reduction in mean keratometric cylinder at 6 months (4.00 D, range: 1.04–8.75 D; from 9.13 D, range: 0.50–18.75 D, preoperatively). Complications included 3 cases (15.8%) of small Descemet membrane perforation, none of which required conversion to penetrating keratoplasty; 3 cases (15.8%) of stromal rejection that resolved with topical steroids; and 6 cases (31.6%) of steroid-related intraocular pressure rise that were treated with topical medications. Selective suture removal was initiated a mean of 3.5 months (range: 1.5–6 months) after surgery. Conclusions: The use of the FSL to perform corneal cuts in a mushroom configuration for DALK is reliable and reproducible. Earlier visual rehabilitation may be possible because of the mechanical stability and wound healing advantages of stepped corneal wounds.
- 1 April 2013
- Published by Wolters Kluwer Health in Cornea
- Vol. 32 (4) , 390-395
Long-Term Outcomes of Femtosecond Laser–Assisted Mushroom Configuration Deep Anterior Lamellar Keratoplasty
Purpose: To review the long-term outcomes after femtosecond laser (FSL)–assisted mushroom configuration deep anterior lamellar keratoplasty (DALK). Methods: Noncomparative case series of 19 eyes from 19 patients who underwent FSL-assisted mushroom configuration DALK. Results: Data were available for 14 eyes at 1 month, for 14 at 3 months, for 16 at 6 months, for 10 at 9 months, and for 8 at 1 year. Preoperative mean best-corrected visual acuity was 20/108 (range: 20/30–20/400). At 3 months, the mean best-corrected visual acuity was 20/46 (range: 20/25–20/250), and at a mean final follow-up of 13 months (range: 6–29) it was 20/35 (range: 20/15–20/200). The greatest change in mean spherical equivalent was at 3 months [−2.29 diopters (D), range: −7.38 to +3.38 D; from −9.54 D, range: −20.00 to +3.38 D, preoperatively]. There was 56% reduction in mean keratometric cylinder at 6 months (4.00 D, range: 1.04–8.75 D; from 9.13 D, range: 0.50–18.75 D, preoperatively). Complications included 3 cases (15.8%) of small Descemet membrane perforation, none of which required conversion to penetrating keratoplasty; 3 cases (15.8%) of stromal rejection that resolved with topical steroids; and 6 cases (31.6%) of steroid-related intraocular pressure rise that were treated with topical medications. Selective suture removal was initiated a mean of 3.5 months (range: 1.5–6 months) after surgery. Conclusions: The use of the FSL to perform corneal cuts in a mushroom configuration for DALK is reliable and reproducible. Earlier visual rehabilitation may be possible because of the mechanical stability and wound healing advantages of stepped corneal wounds.
- 1 November 2011
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 152 (5) , 730-732
Management of Recurrent Pterygium With Intraoperative Mitomycin C and Conjunctival Autograft With Fibrin Glue
- 1 November 2011
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 152 (5) , 730-732
Management of Recurrent Pterygium With Intraoperative Mitomycin C and Conjunctival Autograft With Fibrin Glue
- 1 October 2011
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 46 (5) , 403-407
Outcomes of deep anterior lamellar keratoplasty versus intralase enabled penetrating keratoplasty in keratoconus
- 1 October 2011
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 46 (5) , 403-407
Outcomes of deep anterior lamellar keratoplasty versus intralase enabled penetrating keratoplasty in keratoconus
- 1 March 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (3) , 582-587
Combined penetrating keratoplasty and implantation of iris prosthesis intraocular lenses after ocular trauma
To report the outcomes of implantation of intraocular lenses (IOLs) with a prosthetic iris to correct traumatic iris deficiency. Department of Ophthalmology, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada. Case series. The medical records of consecutive patients who had had implantation of an Ophtec or Morcher IOL combined with corneal transplantation were retrospectively reviewed. Preoperative data collected included demographics, etiology of the iris deficiency, previous surgeries, preoperative eye pathology, and visual acuity. Operative data and postoperative outcomes included visual acuity, subjective perception of glare and photophobia, and postoperative complications. The records of 11 patients were reviewed. The corrected distance visual acuity improved from 2.39 logMAR ± 0.53 (SD) preoperatively to 1.50 ± 1.11 logMAR postoperatively (P=.0037). Four (36.4%) of 9 patients reported an improvement in glare sensation; 5 (45.5%) reported no change in glare (P=.99). Postoperative complications included 2 graft rejection episodes in 2 patients during the first year after surgery, 1 case of increased inflammation that required removal of the IOL, and 2 cases of new-onset glaucoma. At the last follow-up visit, the centration and positioning of the IOLs were excellent. There were no cases of IOL dislocation, macular edema, or retinal detachment. Implantation IOLs with a prosthetic iris in traumatic aniridia improved visual acuity significantly in most patients and reduced photophobia and glare symptoms in many cases. Graft rejection, glaucoma, and postoperative inflammation are possible complications. No author has a financial or proprietary interest in any material or method mentioned.
- 1 March 2011
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 37 (3) , 582-587
Combined penetrating keratoplasty and implantation of iris prosthesis intraocular lenses after ocular trauma
To report the outcomes of implantation of intraocular lenses (IOLs) with a prosthetic iris to correct traumatic iris deficiency. Department of Ophthalmology, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada. Case series. The medical records of consecutive patients who had had implantation of an Ophtec or Morcher IOL combined with corneal transplantation were retrospectively reviewed. Preoperative data collected included demographics, etiology of the iris deficiency, previous surgeries, preoperative eye pathology, and visual acuity. Operative data and postoperative outcomes included visual acuity, subjective perception of glare and photophobia, and postoperative complications. The records of 11 patients were reviewed. The corrected distance visual acuity improved from 2.39 logMAR ± 0.53 (SD) preoperatively to 1.50 ± 1.11 logMAR postoperatively (P=.0037). Four (36.4%) of 9 patients reported an improvement in glare sensation; 5 (45.5%) reported no change in glare (P=.99). Postoperative complications included 2 graft rejection episodes in 2 patients during the first year after surgery, 1 case of increased inflammation that required removal of the IOL, and 2 cases of new-onset glaucoma. At the last follow-up visit, the centration and positioning of the IOLs were excellent. There were no cases of IOL dislocation, macular edema, or retinal detachment. Implantation IOLs with a prosthetic iris in traumatic aniridia improved visual acuity significantly in most patients and reduced photophobia and glare symptoms in many cases. Graft rejection, glaucoma, and postoperative inflammation are possible complications. No author has a financial or proprietary interest in any material or method mentioned.
- 1 February 2011
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 46 (1) , 83-86
Keratoconus caused by eye rubbing in patients with Tourette Syndrome
- 1 February 2011
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 46 (1) , 83-86
Keratoconus caused by eye rubbing in patients with Tourette Syndrome
- 1 August 2010
- Published by Wolters Kluwer Health in Cornea
- Vol. 29 (8) , 878-882
The Effect of Successful Rebubbling After Descemet Stripping Automated Endothelial Keratoplasty on Endothelial Cell Counts
To examine the effect of successful repositioning/rebubbling of the graft on endothelial cell counts (ECCs) in eyes after Descemet stripping automated endothelial keratoplasty. This retrospective study reviewed the outcomes of 58 eyes that underwent Descemet stripping automated endothelial keratoplasty. Fifty-one eyes were attached after surgery. Seven were detached and underwent rebubbling with minimal manipulation in 5 and significant manipulation in 2, after which the graft was attached and clear. Visual outcomes and endothelial cell loss at 6 months were compared between eyes that underwent repositioning/rebubbling and those that did not. The following were excluded: 2 eyes that had primary failure, 2 eyes that had rejection, 1 eye that failed to attach after rebubbling, 2 eyes that failed to clear after rebubbling, and 24 eyes that did not have ECC at 6 months. The 2 groups were comparable considering age, preoperative best-corrected visual acuity, surgical variables, combined procedures, donor cell count, and graft size. The mean postoperative spherical equivalent, manifest and topographic astigmatism, uncorrected visual acuity, and best-corrected visual acuity did not differ significantly between the 2 groups at 6 months. Mean pre- and postoperative ECC did not differ significantly between the group that underwent repositioning/rebubbling and the group that did not (preoperative counts 2742 +/- 268 vs. 2747 +/- 353 and postoperative counts 1590 +/- 367 vs. 1746 +/- 491, respectively). Endothelial cell loss also did not differ significantly between the 2 groups, although there was a trend to greater cell loss in the reattachment group (-39.4% +/- 11.1% vs. -38.3% +/- 16.2%, respectively; P = 0.6). Successful reattachment procedure does not seem to cause significant endothelial cell loss.
- 1 August 2010
- Published by Wolters Kluwer Health in Cornea
- Vol. 29 (8) , 878-882
The Effect of Successful Rebubbling After Descemet Stripping Automated Endothelial Keratoplasty on Endothelial Cell Counts
To examine the effect of successful repositioning/rebubbling of the graft on endothelial cell counts (ECCs) in eyes after Descemet stripping automated endothelial keratoplasty. This retrospective study reviewed the outcomes of 58 eyes that underwent Descemet stripping automated endothelial keratoplasty. Fifty-one eyes were attached after surgery. Seven were detached and underwent rebubbling with minimal manipulation in 5 and significant manipulation in 2, after which the graft was attached and clear. Visual outcomes and endothelial cell loss at 6 months were compared between eyes that underwent repositioning/rebubbling and those that did not. The following were excluded: 2 eyes that had primary failure, 2 eyes that had rejection, 1 eye that failed to attach after rebubbling, 2 eyes that failed to clear after rebubbling, and 24 eyes that did not have ECC at 6 months. The 2 groups were comparable considering age, preoperative best-corrected visual acuity, surgical variables, combined procedures, donor cell count, and graft size. The mean postoperative spherical equivalent, manifest and topographic astigmatism, uncorrected visual acuity, and best-corrected visual acuity did not differ significantly between the 2 groups at 6 months. Mean pre- and postoperative ECC did not differ significantly between the group that underwent repositioning/rebubbling and the group that did not (preoperative counts 2742 +/- 268 vs. 2747 +/- 353 and postoperative counts 1590 +/- 367 vs. 1746 +/- 491, respectively). Endothelial cell loss also did not differ significantly between the 2 groups, although there was a trend to greater cell loss in the reattachment group (-39.4% +/- 11.1% vs. -38.3% +/- 16.2%, respectively; P = 0.6). Successful reattachment procedure does not seem to cause significant endothelial cell loss.