Richard S. Pieters
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Richard S. Pieters has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Thomas J. FitzGerald
University of Massachusetts Medical School, Worcester, MA
2 shared publications Bruce A Bornstein
University of Massachusetts Medical School, Worcester, MA
1 shared publicationI-Lin Eric Kuo
University of Massachusetts Medical School, Worcester, MA
1 shared publicationI-LinEric Kuo
1 shared publication
Latest Publications
- 1 November 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (31) , 179
The impact of radiotherapy technique on normal tissue dose in treatment of spinal vertebral metastases.
179 Background: The optimal management of uncomplicated spinal vertebral metastases has yet to be determined. Preliminary evidence, suggesting single fraction therapy may be associated with fewer gastrointestinal side effects, did not report radiotherapy (RT) technique. Recent clinical experience with more advanced imaging and treatment delivery systems leads us to question if this approach is optimal given the radiation therapy dose to the surrounding normal tissues. The purpose of this study is to examine the impact of current RT techniques on normal tissue dose, which is known to affect acute tolerance of sensitive organs. The focus is on the bowel, an organ known for its radio-sensitivity which can impact quality of life. Methods: In a de-identified treatment planning CT of a patient with spinal metastases, the target volume of vertebrae from T9-L5 was defined and the normal bowel was outlined. Five RT techniques were planned: 1) the former standard, posterior/anterior (PA) 6MV field prescribed to a depth of 5 cm, 2) a PA 18MV field prescribed to a depth of 5 cm, 3) an opposed AP/PA dual energy plan, weighted posteriorly 2:1, 4) a 3-field 18MV plan (PA & 2 posterior oblique fields), and 5) an intensity modulated radiotherapy (IMRT) plan, using 4 arcs. The last 3 techniques were optimized to minimize anterior dose to the bowel. Results: The 5 techniques delivered varying RT doses (Dmax%) to the bowel ranging from the highest (AP/PA dual energy plan) to the lowest (IMRT), expressed as a percentage of the prescription dose. Conclusions: Single fraction RT techniques, with the exception of IMRT, approach tolerance (Dmax%) for some bowel tissue, which may preclude retreatment. IMRT would also allow for dose escalation to the spinal target volume, possibly improving efficacy and reducing the need for retreatment. Future studies should report RT technique, dose and fractionation to optimize efficacy and tolerance. [Table: see text]
- 1 November 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (31) , 179
The impact of radiotherapy technique on normal tissue dose in treatment of spinal vertebral metastases.
179 Background: The optimal management of uncomplicated spinal vertebral metastases has yet to be determined. Preliminary evidence, suggesting single fraction therapy may be associated with fewer gastrointestinal side effects, did not report radiotherapy (RT) technique. Recent clinical experience with more advanced imaging and treatment delivery systems leads us to question if this approach is optimal given the radiation therapy dose to the surrounding normal tissues. The purpose of this study is to examine the impact of current RT techniques on normal tissue dose, which is known to affect acute tolerance of sensitive organs. The focus is on the bowel, an organ known for its radio-sensitivity which can impact quality of life. Methods: In a de-identified treatment planning CT of a patient with spinal metastases, the target volume of vertebrae from T9-L5 was defined and the normal bowel was outlined. Five RT techniques were planned: 1) the former standard, posterior/anterior (PA) 6MV field prescribed to a depth of 5 cm, 2) a PA 18MV field prescribed to a depth of 5 cm, 3) an opposed AP/PA dual energy plan, weighted posteriorly 2:1, 4) a 3-field 18MV plan (PA & 2 posterior oblique fields), and 5) an intensity modulated radiotherapy (IMRT) plan, using 4 arcs. The last 3 techniques were optimized to minimize anterior dose to the bowel. Results: The 5 techniques delivered varying RT doses (Dmax%) to the bowel ranging from the highest (AP/PA dual energy plan) to the lowest (IMRT), expressed as a percentage of the prescription dose. Conclusions: Single fraction RT techniques, with the exception of IMRT, approach tolerance (Dmax%) for some bowel tissue, which may preclude retreatment. IMRT would also allow for dose escalation to the spinal target volume, possibly improving efficacy and reducing the need for retreatment. Future studies should report RT technique, dose and fractionation to optimize efficacy and tolerance. [Table: see text]