YDYves Durandy

Yves Durandy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yves Durandy has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Akif Ündar

    Penn State College of Medicine

    3 shared publications
  • Shigang Wang

    Penn State Hershey Pediatric Cardiovascular Research Center, Department of Pediatrics, Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital, Hershey, PA, USA

    2 shared publications
  • Allen R. Kunselman

    Public Health and Sciences; Penn State Milton S. Hershey Medical Center, Penn State Hershey College of Medicine, Penn State Hershey Children's Hospital; Hershey; PA; USA

    1 shared publication
  • Atıf Akçevin

    American Hospital, Department of Cardiovascular Surgery, Istanbul, Turkey; and

    1 shared publication
  • David Palanzo

    Penn State Milton S Hershey Medical Center

    1 shared publication
  • John L. Myers

    Department of Pediatrics, Pediatric Cardiovascular Research Center, Penn State College of Medicine, Penn State Health Children's Hospital, Hershey, PA, USA

    1 shared publication

Latest Publications

  • Open Access

    Rationale for Implementation of Warm Cardiac Surgery in Pediatrics

    by Yves Durandy

    Cardiac surgery was developed thanks to the introduction of hypothermia and cardiopulmonary bypass in the early 1950s. The deep hypothermia protective effect has been essential to circulatory arrest complex cases repair. During the early times of open-heart surgery, a major concern was to decrease mortality and to improve short-term outcomes. Both mortality and morbidity dramatically decreased over a few decades. As a consequence, the drawbacks of deep hypothermia, with or without circulatory arrest, became more and more apparent. The limitation of hypothermia was particularly evident for the brain and regional perfusion was introduced as a response to this problem. Despite a gain in popularity, the results of regional perfusion were not fully convincing. In the 1990s, warm surgery was introduced in adults and proved to be safe and reliable. This option eliminates the deleterious effect of ischemia reperfusion injuries through a continuous, systemic coronary perfusion with warm oxygenated blood. Intermittent warm blood cardioplegia was introduced later, with impressive results. We were convinced by the easiness, safety and efficiency of warm surgery and shifted to warm pediatric surgery in a two-step program. This article outlines the limitations of hypothermic protection and the basic reasons that led us to implement pediatric warm surgery. After tens of thousands of cases performed across several centers, this reproducible technique proved a valuable alternative to hypothermic surgery.


  • Use of Blood Products in Pediatric Cardiac Surgery

    by Yves Durandy

    In pediatric cardiac surgery, there is a substantial gap between published recommendations or guidelines for blood product use and clinical practice. The drawbacks of blood transfusion are well acknowledged though. The aim of this paper is to present the rationale for packed red blood cells, fresh frozen plasma (FFP), and platelets used in pediatric patients. Blood hemoglobin level is the current trigger used for packed red blood cells transfusion, though commonly admitted to be suboptimal. An increase in hemoglobin level is likely to be associated with an increase in blood oxygen content and blood oxygen delivery. However, above a critical level of hemoglobin, normovolemic anemia is well tolerated, and any increase in hemoglobin will fail to increase oxygen consumption and therefore to improve end‐organ oxygen supply. FFP is one way to address the coagulation factors deficiency induced by hemodilution, consumption, or hepatic insufficiency. The volume needed to increase these factors is not negligible. To avoid dilution and/or fluid overload, the use of clotting factor concentrate is recommended. The same remark can be made regarding the treatment of antithrombin III deficiency. Platelets infusion should be restricted to bleeding patients with thrombocytopenia and without surgical bleeding. In clinical studies, the prevention of bleeding through prophylactic infusion of platelets proved to be useless. Optimizing the use of blood products (avoiding overuse, underuse, and inappropriate use) is a challenging task in pediatric cardiac surgery. Data or guidelines cannot replace clinical judgment and the decision to transfuse is left to individual discretion, but the medical community needs to optimize its transfusion practice, otherwise policy‐makers without similar expertise may step in to regulate the use of blood products.


  • Open Access

    Is there a rationale for short cardioplegia re-dosing intervals?

    by Yves D Durandy

    While cardioplegia has been used on millions of patients during the last decades, the debate over the best technique is still going on. Cardioplegia is not only meant to provide a non-contracting heart and a field without blood, thus avoiding the risk of gas emboli, but also used for myocardial protection. Its electromechanical effect is easily confirmed through direct vision of the heart and continuous electrocardiogram monitoring, but there is no consensus on the best way to assess the quality of myocardial protection. The optimal approach is thus far from clear and the considerable amount of literature on the subject fails to provide a definite answer. Cardioplegia composition (crystalloid vs blood, with or without various substrate enhancement), temperature and site(s) of injection have been extensively researched. While less frequently studied, re-dosing interval is also an important factor. A common and intuitive idea is that shorter re-dosing intervals lead to improved myocardial protection. A vast majority of surgeons use re-dosing intervals of 20-30 min, or even less, during coronary artery bypass graft and multidose cardioplegia has been the “gold standard” for decades. However, one-shot cardioplegia is becoming more commonly used and is likely to be a valuable alternative. Some surgeons prefer the comfort of single-shot cardioplegia while others feel more confident with shorter re-dosing intervals. There is no guarantee that a single strategy can be safely applied to all patients, irrespective of their age, comorbidities or cardiopathy. The goal of this review is to discuss the rationale for short re-dosing intervals.


  • Minimizing Systemic Inflammation During Cardiopulmonary Bypass in the Pediatric Population

    by Yves Durandy

    Cardiopulmonary bypass (CPB) is known to cause a systemic inflammatory response. Inflammation includes several cascade activations: complement, cytokine, and coagulation. The early phase is triggered by blood contact with the synthetic bypass circuit and the late phase by ischemia‐reperfusion and endotoxemia. Systemic inflammatory response syndrome (SIRS) is constant following cardiac surgery; however, a compensatory anti‐inflammatory response is also constant and the clinical manifestations (varying from uncomplicated SIRS to shock and multiple organ dysfunction) depend on the balance between the two responses. When overexpressed, the inflammatory response may significantly increase a patient's risk. Minimization of systemic inflammation is a major concern and several strategies aiming to inhibit the inflammatory response are described. None of them is satisfactory, but the “control” of the inflammatory response extent is likely to require a multimodal approach. This review aims to describe the strategies proposed to reduce CPB‐related systemic inflammation.


  • An Original Versatile Nonocclusive Pressure-Regulated Blood Roller Pump for Extracorporeal Perfusion

    by Yves Durandy, Shigang Wang, Akif Ündar

    Currently, only a small number of centrifugal pumps are being used for hemodynamic and/or respiratory support, but all of them have limitations. This article aims to present the Rhône-Poulenc 06 nonocclusive pressure-regulated blood pump. This pump was developed in France in the 1970s and used for decades in perfusion for cardiopulmonary bypass procedures, cardiac or lung assist as well as venovenous bypass during liver transplant. The intrinsic properties of this pump allowed us to describe a new technique for extracorporeal lung support in the 1980s, using a single cannula tidal flow venovenous bypass. This pump compared favorably with conventional pumps in terms of flow and pressure, hemolysis, pulsatility, safety, and cost-effectiveness. We believe that this simple pump could be an alternative to more sophisticated and expensive devices.


  • Open Access

    Vacuum-Assisted Venous Drainage, Angel or Demon: PRO?

    by Yves Durandy

    Vacuum-assisted venous drainage (VAVD) was proposed to optimize venous drainage during bypass through femoral venous cannulation. It is currently used in both adult and pediatric surgery when siphon gravity venous drainage is suboptimal. In pediatric surgery, the major advantages of VAVD are a significant decrease in cardiopulmonary bypass prime volume and an improved drainage with all collateral benefits. To limit gravity drainage, we use a two-level heart–lung machine dedicated to pediatric perfusion. The top level of the cardiotomy reservoir is positioned at the patient atrial level, making it possible to downsize the length and diameter of venous and arterial lines. Since 2008, a negative pressure of approximately −30 mmHg has been used for all patients. Initiation of bypass is performed in a classical way with a cardiotomy reservoir open; vacuum is added as soon as the maximal gravity drainage is reached. During bypass, when the blood level in the reservoir decreases to the safety limit level, a small increase in negative pressure is used to improve venous drainage. For weaning from bypass, the negative pressure is gradually decreased to zero, then the reservoir is opened and the venous line progressively closed. Prime volumes were significantly reduced to 100 mL for small neonates, 125 mL for infants, and 175 mL for older children with flow up to 1.5 L/min−1. A low prime volume is expected to improve blood conservation and decrease donor exposure, prevent drawbacks of transfusion (immunomodulation, infection), increase the incidence of blood-free surgery in smaller babies, and decrease whole body systemic inflammation by decreasing surface of foreign material in contact with blood and inflammation associated with blood transfusion. The main drawbacks described have been retrograde flow in the venous line with cerebral air embolus and an increased incidence of gaseous microemboli. These drawbacks are avoidable through appropriate training of perfusionists. When negative pressure is “reasonable,” complications are more theoretical than significant in clinical practice. A technique with a benefit/drawback ratio of 1:0 is utopian, but the advantages of VAVD far outweigh any potential drawbacks when applied properly.


  • Characteristics of a Nonocclusive Pressure‐Regulated Blood Roller Pump

    by Yves Durandy

    For decades, extracorporeal life support (ECLS) systems have relied on pumps designed for short‐term cardiopulmonary bypass. In the past, occlusive roller pumps were the standard. They are being progressively replaced by centrifugal pumps and devices developed specifically for ECLS. However, the ideal pump for long‐term bypass is yet to be created. One interesting alternative is the Rhône‐Poulenc 06 pump that is a nonocclusive pressure‐regulated blood pump developed in France in the 1970s. This pump is composed of a double‐stage rotor with three rollers at each level. The raceway tubing is stretched on the roller and pump occlusivity depends on the tension of the chamber on the rotor. The pump is able to deliver physiological blood flow values without generating dangerous negative or positive pressures. The specific design of the chamber allows the pump to generate a pulsatile flow, inducing minimal blood trauma, and to act as a bubble trap, making it inherently safe. This pump has been used for cardiopulmonary bypass, extracorporeal lung support, and more specifically single‐lumen single‐cannula venovenous membrane oxygenation for neonates, left‐heart or right‐heart assist, and venovenous bypass during liver transplant. In conclusion, this old‐fashion pump is perfectly adapted for any kind of short‐ or long‐term bypass.


  • Open Access

    Pulmonary Artery Banding is Still a Valuable Option

    by Yves Durandy

    Pulmonary Artery Banding is Still a Valuable Option