Paola Chiovati
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paola Chiovati has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Annalisa Drigo
Medical Physics Department, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, 33081 Aviano, Italy
5 shared publications - Angela Caroli
Department of Radiation Oncology, Centro di Riferimento Oncologico di Aviano (CRO), Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), National Cancer Institute, 33081 Aviano, Italy
4 shared publications - Cristina Cappelletto
Medical Physics Department, Centro di Riferimento Oncologico di Aviano IRCCS, 33081 Aviano, Italy
4 shared publications - Michele Avanzo
Centro di Riferimento Oncologico di Aviano IRCCS
4 shared publications - Andrea Dassie
Medical Physics Department, Centro di Riferimento Oncologico di Aviano IRCCS, 33081 Aviano, Italy
3 shared publications - Fabio Matrone
Division of Radiation Oncology, Centro di Riferimento Oncologico di Aviano (CRO), IRCCS, 33081 Aviano, Italy
3 shared publications
Latest Publications
- Open Access
Validation of Synthetic Megavoltage Computed Tomography (MVCT) for Dose Calculation in Radiotherapy Treatment Planning
Background/Objectives: Dental metallic implants cause severe streaking artifacts in kilovoltage CT (kVCT), compromising dose calculation in radiotherapy (RT) treatment planning. The purpose of this study is to assess the dosimetric agreement of synthetic MVCT (sMVCT) images generated from artifact-affected kVCT using a deep learning network with respect to true MVCT (tMVCT) acquired at the treatment machine. Methods: Nineteen head and neck cancer patients with dental metallic implants treated with RT were included. Planning kVCT images were converted to sMVCT using Metal Artifact Reduction through Domain Transformation Network (MAR-DTN), a UNet-inspired deep learning network. The sMVCT images were rigidly registered to true MVCT (tMVCT) acquired on the Hi-Art II Tomotherapy system. Mean Hounsfield Unit (HU) values were compared across seven structures (thyroid, bilateral parotids, brainstem, spinal cord, GTV, PTV70) using pairwise Wilcoxon tests and Two One-Sided Tests (TOST) for statistical equivalence within a pre-specified margin of ±20 HU (corresponding to a 2% deviation in physical density). Dose distributions were recalculated on sMVCT using the AAA algorithm and compared to reference tMVCT-based plans via dose–volume histogram (DVH) metrics, evaluated for equivalence by TOST within a margin of ±2% of the prescribed dose (±142 cGy of 70.95 Gy), and via 3D gamma index, evaluated by one-sided non-inferiority test against the clinically accepted thresholds of 90% (2 mm/2%) and 95% (3 mm/3%). A pre-specified sensitivity analysis was performed by repeating all comparisons on the strictly independent sub-cohort (n = 16) excluding three patients drawn from the MAR-DTN training set. Results: All seven anatomical structures showed statistical equivalence between sMVCT and tMVCT under the ±20 HU margin (TOST p < 0.05; mean HU differences in the range −1.1 to +8.4 HU; all Wilcoxon p > 0.05). All nine DVH metrics achieved formal dosimetric equivalence within ±2% of the prescribed dose (TOST p < 0.05). Mean 3D gamma pass rates were 94.3% (95% CI: 89.3–97.1) for the 2 mm/2% criterion and 97.6% (95% CI: 94.8–99.0) for the 3 mm/3% criterion, both formally non-inferior to the respective clinical thresholds (p < 0.0001). Residual gamma failures were concentrated at the patient surface, consistent with inter-session repositioning uncertainty rather than errors in synthetic image generation. Sensitivity analysis on the n = 16 sub-cohort confirmed all conclusions, with mean HU and DVH differences smaller than in the full cohort for the structures showing the largest mean differences, and comparable for the remaining structures, with all TOST equivalence and gamma non-inferiority tests confirmed in both cohorts. Conclusions: sMVCT images generated via MAR-DTN show dosimetric agreement with physically acquired tMVCT in head and neck patients with dental implants, formally demonstrated by TOST equivalence within ±2% of prescribed dose for all DVH metrics. The combined HU and gamma index framework presented here represents a promising quality assurance approach for AI-based synthetic imaging tools in radiotherapy, pending validation in larger prospective multicentre cohorts.
Open AccessValidation of Synthetic Megavoltage Computed Tomography (MVCT) for Dose Calculation in Radiotherapy Treatment Planning
Background/Objectives: Dental metallic implants cause severe streaking artifacts in kilovoltage CT (kVCT), compromising dose calculation in radiotherapy (RT) treatment planning. The purpose of this study is to assess the dosimetric agreement of synthetic MVCT (sMVCT) images generated from artifact-affected kVCT using a deep learning network with respect to true MVCT (tMVCT) acquired at the treatment machine. Methods: Nineteen head and neck cancer patients with dental metallic implants treated with RT were included. Planning kVCT images were converted to sMVCT using Metal Artifact Reduction through Domain Transformation Network (MAR-DTN), a UNet-inspired deep learning network. The sMVCT images were rigidly registered to true MVCT (tMVCT) acquired on the Hi-Art II Tomotherapy system. Mean Hounsfield Unit (HU) values were compared across seven structures (thyroid, bilateral parotids, brainstem, spinal cord, GTV, PTV70) using pairwise Wilcoxon tests and Two One-Sided Tests (TOST) for statistical equivalence within a pre-specified margin of ±20 HU (corresponding to a 2% deviation in physical density). Dose distributions were recalculated on sMVCT using the AAA algorithm and compared to reference tMVCT-based plans via dose–volume histogram (DVH) metrics, evaluated for equivalence by TOST within a margin of ±2% of the prescribed dose (±142 cGy of 70.95 Gy), and via 3D gamma index, evaluated by one-sided non-inferiority test against the clinically accepted thresholds of 90% (2 mm/2%) and 95% (3 mm/3%). A pre-specified sensitivity analysis was performed by repeating all comparisons on the strictly independent sub-cohort (n = 16) excluding three patients drawn from the MAR-DTN training set. Results: All seven anatomical structures showed statistical equivalence between sMVCT and tMVCT under the ±20 HU margin (TOST p < 0.05; mean HU differences in the range −1.1 to +8.4 HU; all Wilcoxon p > 0.05). All nine DVH metrics achieved formal dosimetric equivalence within ±2% of the prescribed dose (TOST p < 0.05). Mean 3D gamma pass rates were 94.3% (95% CI: 89.3–97.1) for the 2 mm/2% criterion and 97.6% (95% CI: 94.8–99.0) for the 3 mm/3% criterion, both formally non-inferior to the respective clinical thresholds (p < 0.0001). Residual gamma failures were concentrated at the patient surface, consistent with inter-session repositioning uncertainty rather than errors in synthetic image generation. Sensitivity analysis on the n = 16 sub-cohort confirmed all conclusions, with mean HU and DVH differences smaller than in the full cohort for the structures showing the largest mean differences, and comparable for the remaining structures, with all TOST equivalence and gamma non-inferiority tests confirmed in both cohorts. Conclusions: sMVCT images generated via MAR-DTN show dosimetric agreement with physically acquired tMVCT in head and neck patients with dental implants, formally demonstrated by TOST equivalence within ±2% of prescribed dose for all DVH metrics. The combined HU and gamma index framework presented here represents a promising quality assurance approach for AI-based synthetic imaging tools in radiotherapy, pending validation in larger prospective multicentre cohorts.
- 4 March 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (2) , 417-424
Comparative analysis of radiotherapy modalities and techniques for left breast cancer: dose coverage, setup accuracy, with patient-specific selection criteria for applying deep inspiration breath hold
To compare dosimetric outcomes between Free Breath (FB) and Deep Inspiration Breath Hold (DIBH) across different radiotherapy modalities, establish patient selection criteria for DIBH, and optimizing the setup margin (SM) in left breast cancer treatment. 26 patients with left breast cancer were studied at CRO, Aviano in Italy. FB and DIBH simulations were done using CT with a real-time position management system. 3DCRT and IMRT plans were prepared for both simulations of each patient. The setup margin was measured by Van Herk’s formula and compared with residual uncertainties. The dose coverage of PTV and spare OARs were better with DIBH. The distance of more than 1.6 cm between (Left Anterior Descending artery) LAD and PTV was no significantly different for FB and DIBH. The setup margin by Van Herk’s formula was calculated as 0.9 cm for DIBH_IMRT. The average duration of DIBH per respiration was 19 ± 4 s. So, holding one breath at least 19 s would be the criteria for choosing a patient to apply DIBH. DIBH enhances PTV dose coverage and OAR sparing in both 3DCRT and IMRT. When the distance between the LAD and PTV exceeds 1.6 cm, the application of DIBH depends on the availability of a LINAC with RPM and the patient’s breathholding ability.
- 4 March 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (2) , 417-424
Comparative analysis of radiotherapy modalities and techniques for left breast cancer: dose coverage, setup accuracy, with patient-specific selection criteria for applying deep inspiration breath hold
To compare dosimetric outcomes between Free Breath (FB) and Deep Inspiration Breath Hold (DIBH) across different radiotherapy modalities, establish patient selection criteria for DIBH, and optimizing the setup margin (SM) in left breast cancer treatment. 26 patients with left breast cancer were studied at CRO, Aviano in Italy. FB and DIBH simulations were done using CT with a real-time position management system. 3DCRT and IMRT plans were prepared for both simulations of each patient. The setup margin was measured by Van Herk’s formula and compared with residual uncertainties. The dose coverage of PTV and spare OARs were better with DIBH. The distance of more than 1.6 cm between (Left Anterior Descending artery) LAD and PTV was no significantly different for FB and DIBH. The setup margin by Van Herk’s formula was calculated as 0.9 cm for DIBH_IMRT. The average duration of DIBH per respiration was 19 ± 4 s. So, holding one breath at least 19 s would be the criteria for choosing a patient to apply DIBH. DIBH enhances PTV dose coverage and OAR sparing in both 3DCRT and IMRT. When the distance between the LAD and PTV exceeds 1.6 cm, the application of DIBH depends on the availability of a LINAC with RPM and the patient’s breathholding ability.
- Open Access
Clinical Use of a Commercial Artificial Intelligence-Based Software for Autocontouring in Radiation Therapy: Geometric Performance and Dosimetric Impact
Purpose: When autocontouring based on artificial intelligence (AI) is used in the radiotherapy (RT) workflow, the contours are reviewed and eventually adjusted by a radiation oncologist before an RT treatment plan is generated, with the purpose of improving dosimetry and reducing both interobserver variability and time for contouring. The purpose of this study was to evaluate the results of application of a commercial AI-based autocontouring for RT, assessing both geometric accuracies and the influence on optimized dose from automatically generated contours after review by human operator. Materials and Methods: A commercial autocontouring system was applied to a retrospective database of 40 patients, of which 20 were treated with radiotherapy for prostate cancer (PCa) and 20 for head and neck cancer (HNC). Contours resulting from AI were compared against AI contours reviewed by human operator and human-only contours using Dice similarity coefficient (DSC), Hausdorff distance (HD), and relative volume difference (RVD). Dosimetric indices such as Dmean, D0.03cc, and normalized plan quality metrics were used to compare dose distributions from RT plans generated from structure sets contoured by humans assisted by AI against plans from manual contours. The reduction in contouring time obtained by using automated tools was also assessed. A Wilcoxon rank sum test was computed to assess the significance of differences. Interobserver variability of the comparison of manual vs. AI-assisted contours was also assessed among two radiation oncologists for PCa. Results: For PCa, AI-assisted segmentation showed good agreement with expert radiation oncologist structures with average DSC among patients ≥ 0.7 for all structures, and minimal radiation oncology adjustment of structures (DSC of adjusted versus AI structures ≥ 0.91). For HNC, results of comparison between manual and AI contouring varied considerably e.g., 0.77 for oral cavity and 0.11–0.13 for brachial plexus, but again, adjustment was generally minimal (DSC of adjusted against AI contours 0.97 for oral cavity, 0.92–0.93 for brachial plexus). The difference in dose for the target and organs at risk were not statistically significant between human and AI-assisted, with the only exceptions of D0.03cc to the anal canal and Dmean to the brachial plexus. The observed average differences in plan quality for PCa and HNC cases were 8% and 6.7%, respectively. The dose parameter changes due to interobserver variability in PCa were small, with the exception of the anal canal, where large dose variations were observed. The reduction in time required for contouring was 72% for PCa and 84% for HNC. Conclusions: When an autocontouring system is used in combination with human review, the time of the RT workflow is significantly reduced without affecting dose distribution and plan quality.
Open AccessClinical Use of a Commercial Artificial Intelligence-Based Software for Autocontouring in Radiation Therapy: Geometric Performance and Dosimetric Impact
Purpose: When autocontouring based on artificial intelligence (AI) is used in the radiotherapy (RT) workflow, the contours are reviewed and eventually adjusted by a radiation oncologist before an RT treatment plan is generated, with the purpose of improving dosimetry and reducing both interobserver variability and time for contouring. The purpose of this study was to evaluate the results of application of a commercial AI-based autocontouring for RT, assessing both geometric accuracies and the influence on optimized dose from automatically generated contours after review by human operator. Materials and Methods: A commercial autocontouring system was applied to a retrospective database of 40 patients, of which 20 were treated with radiotherapy for prostate cancer (PCa) and 20 for head and neck cancer (HNC). Contours resulting from AI were compared against AI contours reviewed by human operator and human-only contours using Dice similarity coefficient (DSC), Hausdorff distance (HD), and relative volume difference (RVD). Dosimetric indices such as Dmean, D0.03cc, and normalized plan quality metrics were used to compare dose distributions from RT plans generated from structure sets contoured by humans assisted by AI against plans from manual contours. The reduction in contouring time obtained by using automated tools was also assessed. A Wilcoxon rank sum test was computed to assess the significance of differences. Interobserver variability of the comparison of manual vs. AI-assisted contours was also assessed among two radiation oncologists for PCa. Results: For PCa, AI-assisted segmentation showed good agreement with expert radiation oncologist structures with average DSC among patients ≥ 0.7 for all structures, and minimal radiation oncology adjustment of structures (DSC of adjusted versus AI structures ≥ 0.91). For HNC, results of comparison between manual and AI contouring varied considerably e.g., 0.77 for oral cavity and 0.11–0.13 for brachial plexus, but again, adjustment was generally minimal (DSC of adjusted against AI contours 0.97 for oral cavity, 0.92–0.93 for brachial plexus). The difference in dose for the target and organs at risk were not statistically significant between human and AI-assisted, with the only exceptions of D0.03cc to the anal canal and Dmean to the brachial plexus. The observed average differences in plan quality for PCa and HNC cases were 8% and 6.7%, respectively. The dose parameter changes due to interobserver variability in PCa were small, with the exception of the anal canal, where large dose variations were observed. The reduction in time required for contouring was 72% for PCa and 84% for HNC. Conclusions: When an autocontouring system is used in combination with human review, the time of the RT workflow is significantly reduced without affecting dose distribution and plan quality.
- Open Access
- 14 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 4962
Artificial Intelligence-Based Patient Selection for Deep Inspiration Breath-Hold Breast Radiotherapy from Respiratory Signals
Purpose: to predict eligibility for deep inspiration breath-hold (DIBH) radiotherapy (RT) treatment of patients with left breast cancer from analysis of respiratory signal, using Deep Bidirectional Long Short-Term Memory (BLSTM) recurrent neural networks. Methods: The respiratory traces from 36 patients who underwent DIBH RT were collected. The patients’ RT treatment plans were generated for both DIBH and free-breathing (FB) modalities. The patients were divided into two classes (patient eligible or not), based on the decrease of maximum dose to the left anterior descending (LAD) artery achieved with DIBH, compared to that achieved with FB and ΔDL. Patients with ΔDL > median value of ΔDL within the patient cohort were assumed to be those selected for DIBH. A BLSTM-RNN was trained for classification of patients eligible for DIBH by analysis of their respiratory signals, as acquired during acquisition of the pre-treatment computed tomography (CT), for selecting the window for DIBH. The dataset was split into training (60%) and test groups (40%), and the hyper-parameters, including the number of hidden layers, the optimizer, the learning rate, and the number of epochs, were selected for optimising model performance. The BLSTM included 2 layers of 100 neural units, each followed by a dropout layer with 20% dropout, and was trained in 35 epochs using the Adam optimizer, with an initial learning rate of 0.0003. Results: The system achieved accuracy, specificity, and sensitivity of, F1 score and area under the receiving operating characteristic curve (AUC) of 71.4%, 66.7%, 80.1%, 72.4%, and 69.4% in the test dataset, respectively. Conclusions: The proposed BLSTM-RNN classified patients in the test set eligible for DIBH with good accuracy. These results look promising for building an accurate and robust decision system to provide automated assistance to the radiotherapy team in assigning patients to DIBH.
- 14 April 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (8) , 4962
Open AccessArtificial Intelligence-Based Patient Selection for Deep Inspiration Breath-Hold Breast Radiotherapy from Respiratory Signals
Purpose: to predict eligibility for deep inspiration breath-hold (DIBH) radiotherapy (RT) treatment of patients with left breast cancer from analysis of respiratory signal, using Deep Bidirectional Long Short-Term Memory (BLSTM) recurrent neural networks. Methods: The respiratory traces from 36 patients who underwent DIBH RT were collected. The patients’ RT treatment plans were generated for both DIBH and free-breathing (FB) modalities. The patients were divided into two classes (patient eligible or not), based on the decrease of maximum dose to the left anterior descending (LAD) artery achieved with DIBH, compared to that achieved with FB and ΔDL. Patients with ΔDL > median value of ΔDL within the patient cohort were assumed to be those selected for DIBH. A BLSTM-RNN was trained for classification of patients eligible for DIBH by analysis of their respiratory signals, as acquired during acquisition of the pre-treatment computed tomography (CT), for selecting the window for DIBH. The dataset was split into training (60%) and test groups (40%), and the hyper-parameters, including the number of hidden layers, the optimizer, the learning rate, and the number of epochs, were selected for optimising model performance. The BLSTM included 2 layers of 100 neural units, each followed by a dropout layer with 20% dropout, and was trained in 35 epochs using the Adam optimizer, with an initial learning rate of 0.0003. Results: The system achieved accuracy, specificity, and sensitivity of, F1 score and area under the receiving operating characteristic curve (AUC) of 71.4%, 66.7%, 80.1%, 72.4%, and 69.4% in the test dataset, respectively. Conclusions: The proposed BLSTM-RNN classified patients in the test set eligible for DIBH with good accuracy. These results look promising for building an accurate and robust decision system to provide automated assistance to the radiotherapy team in assigning patients to DIBH.
- Open Access
- 13 September 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (9) , 1491
Predicting Local Failure after Partial Prostate Re-Irradiation Using a Dosiomic-Based Machine Learning Model
The aim of this study is to predict local failure after partial prostate re-irradiation for the treatment of isolated locally recurrent prostate cancer by using a machine learning classifier based on radiomic features from pre-treatment computed tomography (CT), positron-emission tomography (PET) and biological effective dose distribution (BED) of the radiotherapy plan. The analysis was conducted on a monocentric dataset of 43 patients with evidence of isolated intraprostatic recurrence of prostate cancer after primary external beam radiotherapy. All patients received partial prostate re-irradiation delivered by volumetric modulated arc therapy. The gross tumor volume (GTV) of each patient was manually contoured from planning CT, choline-PET and dose maps. An ensemble machine learning pipeline including unbalanced data correction and feature selection was trained using the radiomic and dosiomic features as input for predicting occurrence of local failure. The model performance was assessed using sensitivity, specificity, accuracy and area under receiver operating characteristic curves of the score function in 10-fold cross validation repeated 100 times. Local failure was observed in 13 patients (30%), with a median time to recurrence of 36.7 months (range = 6.1–102.4 months). A four variables ensemble machine learning model resulted in accuracy of 0.62 and AUC 0.65. According to our results, a dosiomic machine learning classifier can predict local failure after partial prostate re-irradiation.
- 13 September 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12 (9) , 1491
Open AccessPredicting Local Failure after Partial Prostate Re-Irradiation Using a Dosiomic-Based Machine Learning Model
The aim of this study is to predict local failure after partial prostate re-irradiation for the treatment of isolated locally recurrent prostate cancer by using a machine learning classifier based on radiomic features from pre-treatment computed tomography (CT), positron-emission tomography (PET) and biological effective dose distribution (BED) of the radiotherapy plan. The analysis was conducted on a monocentric dataset of 43 patients with evidence of isolated intraprostatic recurrence of prostate cancer after primary external beam radiotherapy. All patients received partial prostate re-irradiation delivered by volumetric modulated arc therapy. The gross tumor volume (GTV) of each patient was manually contoured from planning CT, choline-PET and dose maps. An ensemble machine learning pipeline including unbalanced data correction and feature selection was trained using the radiomic and dosiomic features as input for predicting occurrence of local failure. The model performance was assessed using sensitivity, specificity, accuracy and area under receiver operating characteristic curves of the score function in 10-fold cross validation repeated 100 times. Local failure was observed in 13 patients (30%), with a median time to recurrence of 36.7 months (range = 6.1–102.4 months). A four variables ensemble machine learning model resulted in accuracy of 0.62 and AUC 0.65. According to our results, a dosiomic machine learning classifier can predict local failure after partial prostate re-irradiation.
- Open Access
Prognostic Nutritional Index Predicts Toxicity in Head and Neck Cancer Patients Treated with Definitive Radiotherapy in Association with Chemotherapy
Background: The Prognostic Nutritional Index (PNI) is a parameter of nutritional and inflammation status related to toxicity in cancer treatment. Since data for head and neck cancer are scanty, this study aims to investigate the association between PNI and acute and late toxicity for this malignancy. Methods: A retrospective cohort of 179 head and neck cancer patients treated with definitive radiotherapy with induction/concurrent chemotherapy was followed-up (median follow-up: 38 months) for toxicity and vital status between 2010 and 2017. PNI was calculated according to Onodera formula and low/high PNI levels were defined according to median value. Odds ratio (OR) for acute toxicity were calculated through logistic regression model; hazard ratios (HR) for late toxicity and survival were calculated through the Cox proportional hazards model. Results: median PNI was 50.0 (interquartile range: 45.5–53.5). Low PNI was associated with higher risk of weight loss > 10% during treatment (OR = 4.84, 95% CI: 1.73–13.53 for PNI < 50 versus PNI ≥ 50), which was in turn significantly associated with worse overall survival, and higher risk of late mucositis (HR = 1.84; 95% CI:1.09–3.12). PNI predicts acute weight loss >10% and late mucositis. Conclusions: PNI could help clinicians to identify patients undergoing radiotherapy who are at high risk of acute and late toxicity.
Open AccessPrognostic Nutritional Index Predicts Toxicity in Head and Neck Cancer Patients Treated with Definitive Radiotherapy in Association with Chemotherapy
Background: The Prognostic Nutritional Index (PNI) is a parameter of nutritional and inflammation status related to toxicity in cancer treatment. Since data for head and neck cancer are scanty, this study aims to investigate the association between PNI and acute and late toxicity for this malignancy. Methods: A retrospective cohort of 179 head and neck cancer patients treated with definitive radiotherapy with induction/concurrent chemotherapy was followed-up (median follow-up: 38 months) for toxicity and vital status between 2010 and 2017. PNI was calculated according to Onodera formula and low/high PNI levels were defined according to median value. Odds ratio (OR) for acute toxicity were calculated through logistic regression model; hazard ratios (HR) for late toxicity and survival were calculated through the Cox proportional hazards model. Results: median PNI was 50.0 (interquartile range: 45.5–53.5). Low PNI was associated with higher risk of weight loss > 10% during treatment (OR = 4.84, 95% CI: 1.73–13.53 for PNI < 50 versus PNI ≥ 50), which was in turn significantly associated with worse overall survival, and higher risk of late mucositis (HR = 1.84; 95% CI:1.09–3.12). PNI predicts acute weight loss >10% and late mucositis. Conclusions: PNI could help clinicians to identify patients undergoing radiotherapy who are at high risk of acute and late toxicity.
- Open Access
Helical Tomotherapy in Children and Adolescents: Dosimetric Comparisons, Opportunities and Issues
Helical Tomotherapy (HT) is a highly conformal image-guided radiation technique, introduced into clinical routine in 2006 at the Centro di Riferimento Oncologico Aviano (Italy). With this new technology, intensity-modulated radiotherapy (IMRT) is delivered using a helicoidal method. Here we present our dosimetric experiences using HT in 100 children, adolescents and young adults treated from May 2006 to February 2011. The median age of the patients was 13 years (range 1–24). The most common treated site was the central nervous system (50; of these, 24 were craniospinal irradiations), followed by thorax (22), head and neck (10), abdomen and pelvis (11), and limbs (7). The use of HT was calculated in accordance to the target dose conformation, the target size and shape, the dose to critical organs adjacent to the target, simultaneous treatment of multiple targets, and re-irradiation. HT has demonstrated to improve target volume dose homogeneity and the sparing of critical structures, when compared to 3D Linac-based radiotherapy (RT). In standard cases this technique represented a comparable alternative to IMRT delivered with conventional linear accelerator. In certain cases (e.g., craniospinal and pleural treatments) only HT generated adequate treatment plans with good target volume coverage. However, the gain in target conformality should be balanced with the spread of low-doses to distant areas. This remains an open issue for the potential risk of secondary malignancies (SMNs) and longer follow-up is mandatory.
Open AccessHelical Tomotherapy in Children and Adolescents: Dosimetric Comparisons, Opportunities and Issues
Helical Tomotherapy (HT) is a highly conformal image-guided radiation technique, introduced into clinical routine in 2006 at the Centro di Riferimento Oncologico Aviano (Italy). With this new technology, intensity-modulated radiotherapy (IMRT) is delivered using a helicoidal method. Here we present our dosimetric experiences using HT in 100 children, adolescents and young adults treated from May 2006 to February 2011. The median age of the patients was 13 years (range 1–24). The most common treated site was the central nervous system (50; of these, 24 were craniospinal irradiations), followed by thorax (22), head and neck (10), abdomen and pelvis (11), and limbs (7). The use of HT was calculated in accordance to the target dose conformation, the target size and shape, the dose to critical organs adjacent to the target, simultaneous treatment of multiple targets, and re-irradiation. HT has demonstrated to improve target volume dose homogeneity and the sparing of critical structures, when compared to 3D Linac-based radiotherapy (RT). In standard cases this technique represented a comparable alternative to IMRT delivered with conventional linear accelerator. In certain cases (e.g., craniospinal and pleural treatments) only HT generated adequate treatment plans with good target volume coverage. However, the gain in target conformality should be balanced with the spread of low-doses to distant areas. This remains an open issue for the potential risk of secondary malignancies (SMNs) and longer follow-up is mandatory.