Hirofumi Shimada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hirofumi Shimada has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Tatsuya Ohno
Department of Radiation Oncology, Gunma University Graduate School of Medicine, Maebashi 3718511, Japan
8 shared publications - Atsushi Musha
Gunma University Heavy Ion Medical Center, Maebashi, Japan
3 shared publications - Hiroyuki Katoh
Gunma University Heavy Ion Medical Center, Maebashi, Gunma, Japan
3 shared publications - Yoko Kitada
Gunma University Heavy Ion Medical Center, 3-39-22, Showa-machi, Maebashi, Gunma 371-8511, Japan
3 shared publications - Yoshinori Koyama
Department of Diagnostic Radiology, Shibukawa Medical Center, Shibukawa, Gunma, Japan
3 shared publications - Chika Hirai
Gunma University Heavy Ion Medical Center, 3-39-22, Showa-machi, Maebashi, Gunma 371-8511, Japan
2 shared publications
Latest Publications
- Open Access
- 6 December 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 37, 100364
Efficacy of nursing intervention using an adverse event predictive model for head and neck carbon-ion radiotherapy: A prospective clinical study
- 6 December 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 37, 100364
Open AccessEfficacy of nursing intervention using an adverse event predictive model for head and neck carbon-ion radiotherapy: A prospective clinical study
- Open Access
- 30 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (11) , 3103
Patient-Derived Training Simulator for Image-Guided Adaptive Brachytherapy of Locally Advanced Cervical Cancers: Development and Initial Use
Image-guided adaptive brachytherapy (IGABT) using intracavitary and interstitial (IC/IS) techniques plays a pivotal role in definitive radiotherapy for locally advanced cervical cancers. However, the training opportunities for interstitial needle application are limited, preventing this technique from becoming widespread. This study aimed to develop a training simulator for IC/IS brachytherapy. The simulator consists of a soft silicone tumor phantom and acrylic tube mimicking the vagina; it has high visibility because of translucent materials and is compatible with computed tomography (CT) and magnetic resonance imaging (MRI). A patient harboring a typical bulky and irregular-shaped cervical tumor was selected from 495 in-house IGABT-treated candidates, and a tumor phantom (68 × 49 × 45 mm) modeled on this patient was produced from three-dimensional real-scale measurements of the MRI-based high-risk clinical target volume at first brachytherapy. In trial use by two physicians with different levels of IGABT skills, a Fletcher-Suit Asian Pacific applicator, and a Venezia applicator with interstitial needles were nicely applied to the simulator, facilitating successful creation of CT-based treatment plans consistent with clinical practice. Thus, the training simulator can be useful for the training of IC/IS brachytherapy, and warrants further research employing a greater number of phantoms and practitioners to verify its educational value.
- 30 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (11) , 3103
Open AccessPatient-Derived Training Simulator for Image-Guided Adaptive Brachytherapy of Locally Advanced Cervical Cancers: Development and Initial Use
Image-guided adaptive brachytherapy (IGABT) using intracavitary and interstitial (IC/IS) techniques plays a pivotal role in definitive radiotherapy for locally advanced cervical cancers. However, the training opportunities for interstitial needle application are limited, preventing this technique from becoming widespread. This study aimed to develop a training simulator for IC/IS brachytherapy. The simulator consists of a soft silicone tumor phantom and acrylic tube mimicking the vagina; it has high visibility because of translucent materials and is compatible with computed tomography (CT) and magnetic resonance imaging (MRI). A patient harboring a typical bulky and irregular-shaped cervical tumor was selected from 495 in-house IGABT-treated candidates, and a tumor phantom (68 × 49 × 45 mm) modeled on this patient was produced from three-dimensional real-scale measurements of the MRI-based high-risk clinical target volume at first brachytherapy. In trial use by two physicians with different levels of IGABT skills, a Fletcher-Suit Asian Pacific applicator, and a Venezia applicator with interstitial needles were nicely applied to the simulator, facilitating successful creation of CT-based treatment plans consistent with clinical practice. Thus, the training simulator can be useful for the training of IC/IS brachytherapy, and warrants further research employing a greater number of phantoms and practitioners to verify its educational value.
- Open Access
- 1 February 2022
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 167, 65-71
Relationship between oral mucositis and the oral bacterial count in patients with head and neck cancer undergoing carbon ion radiotherapy: A prospective study
- 1 February 2022
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 167, 65-71
Open AccessRelationship between oral mucositis and the oral bacterial count in patients with head and neck cancer undergoing carbon ion radiotherapy: A prospective study
- Open Access
Evaluation of Carbon Ion Radiation-Induced Trismus in Head and Neck Tumors Using Dose-Volume Histograms
Carbon ion radiotherapy (C-ion RT) provides a highly localized deposition of energy that can increase radiation doses to tumors while minimizing irradiation of adjacent normal tissues. For tumors located near the temporomandibular joint, C-ion RT-induced trismus may occur. However, the relationship between the carbon ion dose and the onset of trismus is unclear. In this prospective observational study, we assessed the trismus/carbon ion dose relationship using dose−volume histograms in 35 patients who received C-ion RT in their head and neck regions between 2010 and 2014. Trismus was evaluated in patients according to the Common Terminology Criteria for Adverse Events, version 4.0. All patients were treated with 57.6 or 64.0 Gy (relative biological effectiveness (RBE)) in 16 fractions, and the median follow-up time was 57 months. Grade 2 trismus was observed in six patients. The median onset time was 12 months. At maximum radiation doses, all masticatory muscles and coronoid processes, particularly the masseter muscle, were significantly different (p = 0.003). The contouring of the masseter muscle and coronoid process requires different treatment planning. The maximum radiation doses of the coronoid process can be proposed as a guideline for treatment planning, considering the ease of contouring in C-ion RT.
Open AccessEvaluation of Carbon Ion Radiation-Induced Trismus in Head and Neck Tumors Using Dose-Volume Histograms
Carbon ion radiotherapy (C-ion RT) provides a highly localized deposition of energy that can increase radiation doses to tumors while minimizing irradiation of adjacent normal tissues. For tumors located near the temporomandibular joint, C-ion RT-induced trismus may occur. However, the relationship between the carbon ion dose and the onset of trismus is unclear. In this prospective observational study, we assessed the trismus/carbon ion dose relationship using dose−volume histograms in 35 patients who received C-ion RT in their head and neck regions between 2010 and 2014. Trismus was evaluated in patients according to the Common Terminology Criteria for Adverse Events, version 4.0. All patients were treated with 57.6 or 64.0 Gy (relative biological effectiveness (RBE)) in 16 fractions, and the median follow-up time was 57 months. Grade 2 trismus was observed in six patients. The median onset time was 12 months. At maximum radiation doses, all masticatory muscles and coronoid processes, particularly the masseter muscle, were significantly different (p = 0.003). The contouring of the masseter muscle and coronoid process requires different treatment planning. The maximum radiation doses of the coronoid process can be proposed as a guideline for treatment planning, considering the ease of contouring in C-ion RT.
- Open Access
- 7 November 2017
- Published by Springer Nature in BMC Cancer
- Vol. 17 (1) , 721
Carbon ion radiotherapy for 80 years or older patients with hepatocellular carcinoma
To evaluate the safety and efficacy of carbon ion radiotherapy (C-ion RT) for 80 years or older patients with hepatocellular carcinoma (HCC). Eligibility criteria of this retrospective study were: 1) HCC confirmed by histology or typical hallmarks of HCC by imaging techniques of four-phase multidetector-row computed tomography or dynamic contrast-enhanced magnetic resonance imaging; 2) no intrahepatic metastasis or distant metastasis; 3) no findings suggesting direct infiltration of the gastrointestinal tract; 4) performance status ≤2 by Eastern Cooperative Oncology Group classification; and 5) Child-Pugh classification A or B. Patients received C-ion RT with 52.8 Gy (RBE) or 60.0 Gy (RBE) in four fractions for usual cases and 60.0 Gy (RBE) in 12 fractions for close-to-gastrointestinal tract cases. Toxicities were classified using the National Cancer Institute’s Common Terminology Criteria for Adverse Events (Version 4.0). Between March 2011 and November 2015, 31 patients were treated. The median follow-up period of all patients was 23.2 months (range: 8.4–55.3 months). Median age at the time of registration of C-ion RT was 83 years (range: 80–95 years). Child-Pugh grade A and B were 27 patients and 4 patients, respectively. The 2-year estimated overall survival, local control, and progression-free survival rates were 82.3%, 89.2%, and 51.3%, respectively. No patients had Grade 2 or higher acute toxicities (within 3 months after C-ion RT). One patient experienced progression in Child-Pugh classification from A to B within 3 months after C-ion RT. In late toxicities, Grade 3 encephalopathy was observed in 3 patients, and 2 improved with medication. C-ion RT was effective with minimal toxicities for 80 years or older patients with hepatocellular carcinoma. UMIN000020571 : date of registration, 14 January 2016, retrospectively registered.
- 7 November 2017
- Published by Springer Nature in BMC Cancer
- Vol. 17 (1) , 721
Open AccessCarbon ion radiotherapy for 80 years or older patients with hepatocellular carcinoma
To evaluate the safety and efficacy of carbon ion radiotherapy (C-ion RT) for 80 years or older patients with hepatocellular carcinoma (HCC). Eligibility criteria of this retrospective study were: 1) HCC confirmed by histology or typical hallmarks of HCC by imaging techniques of four-phase multidetector-row computed tomography or dynamic contrast-enhanced magnetic resonance imaging; 2) no intrahepatic metastasis or distant metastasis; 3) no findings suggesting direct infiltration of the gastrointestinal tract; 4) performance status ≤2 by Eastern Cooperative Oncology Group classification; and 5) Child-Pugh classification A or B. Patients received C-ion RT with 52.8 Gy (RBE) or 60.0 Gy (RBE) in four fractions for usual cases and 60.0 Gy (RBE) in 12 fractions for close-to-gastrointestinal tract cases. Toxicities were classified using the National Cancer Institute’s Common Terminology Criteria for Adverse Events (Version 4.0). Between March 2011 and November 2015, 31 patients were treated. The median follow-up period of all patients was 23.2 months (range: 8.4–55.3 months). Median age at the time of registration of C-ion RT was 83 years (range: 80–95 years). Child-Pugh grade A and B were 27 patients and 4 patients, respectively. The 2-year estimated overall survival, local control, and progression-free survival rates were 82.3%, 89.2%, and 51.3%, respectively. No patients had Grade 2 or higher acute toxicities (within 3 months after C-ion RT). One patient experienced progression in Child-Pugh classification from A to B within 3 months after C-ion RT. In late toxicities, Grade 3 encephalopathy was observed in 3 patients, and 2 improved with medication. C-ion RT was effective with minimal toxicities for 80 years or older patients with hepatocellular carcinoma. UMIN000020571 : date of registration, 14 January 2016, retrospectively registered.
- 1 June 2016
- Vol. 36 (6) , 2955-60
Initial Results of Hypofractionated Carbon Ion Radiotherapy for Cholangiocarcinoma.
To report initial results of hypofractionated carbon ion radiotherapy (C-ion RT) for cholangiocarcinoma. Data regarding seven patients with cholangiocarcinoma treated by C-ion RT were analyzed. Prescribed doses were 52.8 Gy [relative biological effectiveness (RBE)] or 60.0 Gy (RBE) in four fractions for intrahepatic cases and 12 fractions for hilar hepatic/close to gastro-intestinal tract cases. Local control and overall survival were evaluated and toxicity was graded using Common Terminology Criteria for Adverse Events, version 4.0. The median follow-up period was 16 months. There were two patients with stage I cancer, one with stage II, one with stage III, and three with stage IVA. Local control was achieved in five out of seven patients (71%) and survival was maintained in six out of seven patients (86%). There were no occurrences of acute or late toxicity of grade 3 or higher. Initial results show that hypofractionated C-ion RT appears to be tolerated and effective for cholangiocarcinoma.
- 1 June 2016
- Vol. 36 (6) , 2955-60
Initial Results of Hypofractionated Carbon Ion Radiotherapy for Cholangiocarcinoma.
To report initial results of hypofractionated carbon ion radiotherapy (C-ion RT) for cholangiocarcinoma. Data regarding seven patients with cholangiocarcinoma treated by C-ion RT were analyzed. Prescribed doses were 52.8 Gy [relative biological effectiveness (RBE)] or 60.0 Gy (RBE) in four fractions for intrahepatic cases and 12 fractions for hilar hepatic/close to gastro-intestinal tract cases. Local control and overall survival were evaluated and toxicity was graded using Common Terminology Criteria for Adverse Events, version 4.0. The median follow-up period was 16 months. There were two patients with stage I cancer, one with stage II, one with stage III, and three with stage IVA. Local control was achieved in five out of seven patients (71%) and survival was maintained in six out of seven patients (86%). There were no occurrences of acute or late toxicity of grade 3 or higher. Initial results show that hypofractionated C-ion RT appears to be tolerated and effective for cholangiocarcinoma.
- Open Access
- 17 September 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 187
Dosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma
The purpose of this study was to compare carbon ion radiotherapy (C-ion RT) and stereotactic radiotherapy (SBRT) with photon beams for the treatment of hepatocellular carcinoma (HCC), specifically with regard to the dose volume parameters for target coverage and normal tissue sparing. Data of 10 patients who were treated using C-ion RT with a total dose of 60 Gy(RBE) in four fractions were used. The virtual plan of SBRT was simulated on the treatment planning computed tomography images of C-ion RT. Dose volume parameters such as minimum dose covering 90 % of the planning target volume (PTV D90), homogeneity index (HI), conformity index (CI), mean liver dose (MLD), volume of the liver receiving 5 to 60 Gy (V5-60), and max point dose (Dmax) of gastrointestinal (GI) tract were calculated from both treatment plans. The PTV D90 was 59.6 ± 0.2 Gy(RBE) in C-ion RT, as compared to 56.6 ± 0.3 Gy in SBRT (p < 0.05). HI and CI were 1.19 ± 0.03 and 0.79 ± 0.06, respectively in C-ion RT, as compared to 1.21 ± 0.01 and 0.37 ± 0.02, respectively in SBRT. Only CI showed a significant difference between two modalities. Mean liver dose was 8.1 ± 1.4 Gy(RBE) in C-ion RT, as compared to 16.1 ± 2.5 Gy in SBRT (p < 0.05). V5 to V50 of liver were higher in SBRT than C-ion RT and significant differences were observed for V5, V10 and V20. Dmax of the GI tract was higher in SBRT than C-ion RT, but did not show a significantly difference. C-ion RT provides an advantage in both target conformity and normal liver sparing compared with SBRT.
- 17 September 2015
- Published by Springer Nature in Radiation Oncology
- Vol. 10 (1) , 187
Open AccessDosimetric comparison of carbon ion radiotherapy and stereotactic body radiotherapy with photon beams for the treatment of hepatocellular carcinoma
The purpose of this study was to compare carbon ion radiotherapy (C-ion RT) and stereotactic radiotherapy (SBRT) with photon beams for the treatment of hepatocellular carcinoma (HCC), specifically with regard to the dose volume parameters for target coverage and normal tissue sparing. Data of 10 patients who were treated using C-ion RT with a total dose of 60 Gy(RBE) in four fractions were used. The virtual plan of SBRT was simulated on the treatment planning computed tomography images of C-ion RT. Dose volume parameters such as minimum dose covering 90 % of the planning target volume (PTV D90), homogeneity index (HI), conformity index (CI), mean liver dose (MLD), volume of the liver receiving 5 to 60 Gy (V5-60), and max point dose (Dmax) of gastrointestinal (GI) tract were calculated from both treatment plans. The PTV D90 was 59.6 ± 0.2 Gy(RBE) in C-ion RT, as compared to 56.6 ± 0.3 Gy in SBRT (p < 0.05). HI and CI were 1.19 ± 0.03 and 0.79 ± 0.06, respectively in C-ion RT, as compared to 1.21 ± 0.01 and 0.37 ± 0.02, respectively in SBRT. Only CI showed a significant difference between two modalities. Mean liver dose was 8.1 ± 1.4 Gy(RBE) in C-ion RT, as compared to 16.1 ± 2.5 Gy in SBRT (p < 0.05). V5 to V50 of liver were higher in SBRT than C-ion RT and significant differences were observed for V5, V10 and V20. Dmax of the GI tract was higher in SBRT than C-ion RT, but did not show a significantly difference. C-ion RT provides an advantage in both target conformity and normal liver sparing compared with SBRT.
- Open Access
Carbon Ion Radiotherapy at the Gunma University Heavy Ion Medical Center: New Facility Set-up
Carbon ion radiotherapy (C-ion RT) offers superior dose conformity in the treatment of deep-seated tumors compared with conventional X-ray therapy. In addition, carbon ion beams have a higher relative biological effectiveness compared with protons or X-ray beams. C-ion RT for the first patient at Gunma University Heavy Ion Medical Center (GHMC) was initiated in March of 2010. The major specifications of the facility were determined based on the experience of clinical treatments at the National Institute of Radiological Sciences (NIRS), with the size and cost being reduced to one-third of those at NIRS. The currently indicated sites of cancer treatment at GHMC are lung, prostate, head and neck, liver, rectum, bone and soft tissue. Between March 2010 and July 2011, a total of 177 patients were treated at GHMC although a total of 100 patients was the design specification during the period in considering the optimal machine performance. In the present article, we introduce the facility set-up of GHMC, including the facility design, treatment planning systems, and clinical preparations.
Open AccessCarbon Ion Radiotherapy at the Gunma University Heavy Ion Medical Center: New Facility Set-up
Carbon ion radiotherapy (C-ion RT) offers superior dose conformity in the treatment of deep-seated tumors compared with conventional X-ray therapy. In addition, carbon ion beams have a higher relative biological effectiveness compared with protons or X-ray beams. C-ion RT for the first patient at Gunma University Heavy Ion Medical Center (GHMC) was initiated in March of 2010. The major specifications of the facility were determined based on the experience of clinical treatments at the National Institute of Radiological Sciences (NIRS), with the size and cost being reduced to one-third of those at NIRS. The currently indicated sites of cancer treatment at GHMC are lung, prostate, head and neck, liver, rectum, bone and soft tissue. Between March 2010 and July 2011, a total of 177 patients were treated at GHMC although a total of 100 patients was the design specification during the period in considering the optimal machine performance. In the present article, we introduce the facility set-up of GHMC, including the facility design, treatment planning systems, and clinical preparations.