Terence W. Picton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Terence W. Picton has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Patricia Van Roon
Carleton University Canada
4 shared publications - Andrew Dimitrijevic
Institute of Medical Science, Temerty Faculty of Medicine, University of Toronto
2 shared publications Donald T. Stuss
Rotman Research Institute at Baycrest, Toronto, Ontario M6A 2E1, Canada
2 shared publicationsM Sasha John
2 shared publicationsM. Sasha John
2 shared publicationsMichael P. Alexander
Beth Israel Deaconess Medical Center, Boston, MA, USA
2 shared publications
Latest Publications
- 1 February 2009
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (1) , 100-109
Multiple Auditory Steady State Responses (80-101 Hz): Effects of Ear, Gender, Handedness, Intensity and Modulation Rate
To evaluate how the amplitudes and latencies of auditory steady state responses (ASSRs) to multiple stimuli presented at rates between 80 and 101 Hz vary with the ear of stimulation, the handedness or gender of a subject, and the rate and intensity of the stimuli. ASSRs were recorded in a group of 56 young adults (27 females, 13 left handed) using several stimulus conditions. In the two main conditions, four sinusoidally amplitude-modulated tones (each uniquely modulated using rates between 80 and 105 Hz) with carrier frequencies of 500, 1000, 2000, and 4000 Hz, were presented concurrently to each ear (eight total). In the first condition the modulation rates for the left ear were slower than those for the right and in the second condition this relationship was reversed. Other conditions evaluated the responses to single stimuli, to multiple stimuli presented in one ear only and to multiple stimuli presented dichotically (four in each ear) with rates that decreased rather than increased with increasing carrier frequency. Stimuli were presented at an intensity of 73 dB SPL except in two conditions wherein the intensity was 53 dB SPL. At 73 dB SPL, multiple-stimulus ASSRs were significantly reduced (monotic or dichotic) compared with single-stimulus ASSRs, especially at 1000 and 2000 Hz. There were significant differences between monotic and dichotic stimulation. When the stimuli were presented dichotically, the amplitude of the response varied with the relative rates of modulation for the stimuli presented in each ear. ASSRs were larger in the ear with the higher rate when the carrier frequencies were 500 and 1000 Hz and when the modulation rates were <90 Hz. There were no consistent effects of gender or ear of stimulation. There were also no significant effects of handedness. Presenting multiple stimuli at 73 dB SPL in the same ear decreases the amplitude of the ASSR compared with when the stimuli are presented singly. This is caused by the masking effect of low on higher carrier frequencies and some other inhibitory effect of high on lower frequencies. Dichotic stimulation can increase the amplitude of the response to stimuli modulated more rapidly (and concomitantly decrease the responses to the stimuli modulated more slowly). This effect occurs only for carrier frequencies <2000 Hz and for modulation frequencies <90 Hz. Dichotic stimulation also causes a small but highly significant decrease in the latency of the response compared with monotic stimulation.
- 1 February 2009
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (1) , 100-109
Multiple Auditory Steady State Responses (80-101 Hz): Effects of Ear, Gender, Handedness, Intensity and Modulation Rate
To evaluate how the amplitudes and latencies of auditory steady state responses (ASSRs) to multiple stimuli presented at rates between 80 and 101 Hz vary with the ear of stimulation, the handedness or gender of a subject, and the rate and intensity of the stimuli. ASSRs were recorded in a group of 56 young adults (27 females, 13 left handed) using several stimulus conditions. In the two main conditions, four sinusoidally amplitude-modulated tones (each uniquely modulated using rates between 80 and 105 Hz) with carrier frequencies of 500, 1000, 2000, and 4000 Hz, were presented concurrently to each ear (eight total). In the first condition the modulation rates for the left ear were slower than those for the right and in the second condition this relationship was reversed. Other conditions evaluated the responses to single stimuli, to multiple stimuli presented in one ear only and to multiple stimuli presented dichotically (four in each ear) with rates that decreased rather than increased with increasing carrier frequency. Stimuli were presented at an intensity of 73 dB SPL except in two conditions wherein the intensity was 53 dB SPL. At 73 dB SPL, multiple-stimulus ASSRs were significantly reduced (monotic or dichotic) compared with single-stimulus ASSRs, especially at 1000 and 2000 Hz. There were significant differences between monotic and dichotic stimulation. When the stimuli were presented dichotically, the amplitude of the response varied with the relative rates of modulation for the stimuli presented in each ear. ASSRs were larger in the ear with the higher rate when the carrier frequencies were 500 and 1000 Hz and when the modulation rates were <90 Hz. There were no consistent effects of gender or ear of stimulation. There were also no significant effects of handedness. Presenting multiple stimuli at 73 dB SPL in the same ear decreases the amplitude of the ASSR compared with when the stimuli are presented singly. This is caused by the masking effect of low on higher carrier frequencies and some other inhibitory effect of high on lower frequencies. Dichotic stimulation can increase the amplitude of the response to stimuli modulated more rapidly (and concomitantly decrease the responses to the stimuli modulated more slowly). This effect occurs only for carrier frequencies <2000 Hz and for modulation frequencies <90 Hz. Dichotic stimulation also causes a small but highly significant decrease in the latency of the response compared with monotic stimulation.
- Open Access
- 15 July 2008
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 2 (1) , 79-85
Mapping task switching in frontal cortex through neuropsychological group studies
This paper considers evidence provided by large neuropsychological group studies and meta-analyses of functional imaging experiments on the location in frontal cortex of the subprocesses involved in the carrying out of task-switching paradigms. The function of the individual subprocesses is also considered in the light of analyses of the performance of normal subjects.
- 15 July 2008
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 2 (1) , 79-85
Open AccessMapping task switching in frontal cortex through neuropsychological group studies
This paper considers evidence provided by large neuropsychological group studies and meta-analyses of functional imaging experiments on the location in frontal cortex of the subprocesses involved in the carrying out of task-switching paradigms. The function of the individual subprocesses is also considered in the light of analyses of the performance of normal subjects.
- 1 August 2007
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 28 (4) , 542-557
Human Auditory Steady-State Responses During Sweeps of Intensity
Objective: To record steady-state responses to amplitude-modulated tones that change their intensity over time and to see how well behavioral thresholds can be estimated from such responses. Design: The intensity of the stimuli used in this experiment increased from 25 to 75 dB SPL for 8 sec and then decreased back to 25 dB HL during the subsequent 8 sec. Responses to this intensity sweep were averaged and then analyzed using a short-time Fast-Fourier Transform to measure how the amplitude and phase of the responses changed with intensity. One experimental condition presented single 2-kHz tones to the left ear; a second condition examined the use of simultaneously presented multiple tones (0.5, 1, 2, and 4 kHz) to the left ear; a third condition used multiple tones presented dichotically; and a fourth condition presented the multiple dichotic tones in masking noise to simulate either low-frequency (less than 1400 Hz) or high-frequency (greater than 1400 Hz) hearing loss. Physiological thresholds were determined using six different algorithms and the relations between physiological and behavioral thresholds were evaluated to see how well behavioral thresholds could be estimated. Results: The amplitude-intensity functions for the 1 and 2 kHz responses both demonstrated a plateau at higher intensities in the multiple-stimulus conditions but not in the single-stimulus condition. The slope of the amplitude-intensity functions varied significantly with the carrier frequency of the stimulus: 1.30 at 500 Hz, 0.87 at 1000 Hz, 0.75 at 2000 Hz, and 1.40 at 4000 Hz. The slope of the phase-intensity function averaged 1.16 degrees per dB and did not vary with carrier frequency. Estimates of latency, however, indicated that latency increased with decreasing carrier frequency and with decreasing intensity. The performance of the threshold estimating algorithms differed between normal hearing and simulated hearing loss, since the amplitude- and phase-intensity functions in the latter condition were not linear. Physiological-behavioral threshold differences were generally greater for normal hearing than for simulated hearing loss. Linear regression provided the least physiological-behavioral difference but was quite variable during simulated hearing loss. Simply defining threshold as the lowest intensity above which all responses were significantly different from residual EEG noise was the most accurate method in terms of yielding the least standard deviation of the physiological-behavioral difference with an average standard deviation of 10 dB, provided EEG noise levels were low enough in the normal hearing condition. Conclusions: Thresholds can be estimated using intensity sweeps with about the same accuracy as recording separate responses to discrete intensities. Sweep recordings provide additional information about the responses at suprathreshold intensities by clearly determining amplitude- and phase- intensity functions at these intensities.
- 1 August 2007
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 28 (4) , 542-557
Human Auditory Steady-State Responses During Sweeps of Intensity
Objective: To record steady-state responses to amplitude-modulated tones that change their intensity over time and to see how well behavioral thresholds can be estimated from such responses. Design: The intensity of the stimuli used in this experiment increased from 25 to 75 dB SPL for 8 sec and then decreased back to 25 dB HL during the subsequent 8 sec. Responses to this intensity sweep were averaged and then analyzed using a short-time Fast-Fourier Transform to measure how the amplitude and phase of the responses changed with intensity. One experimental condition presented single 2-kHz tones to the left ear; a second condition examined the use of simultaneously presented multiple tones (0.5, 1, 2, and 4 kHz) to the left ear; a third condition used multiple tones presented dichotically; and a fourth condition presented the multiple dichotic tones in masking noise to simulate either low-frequency (less than 1400 Hz) or high-frequency (greater than 1400 Hz) hearing loss. Physiological thresholds were determined using six different algorithms and the relations between physiological and behavioral thresholds were evaluated to see how well behavioral thresholds could be estimated. Results: The amplitude-intensity functions for the 1 and 2 kHz responses both demonstrated a plateau at higher intensities in the multiple-stimulus conditions but not in the single-stimulus condition. The slope of the amplitude-intensity functions varied significantly with the carrier frequency of the stimulus: 1.30 at 500 Hz, 0.87 at 1000 Hz, 0.75 at 2000 Hz, and 1.40 at 4000 Hz. The slope of the phase-intensity function averaged 1.16 degrees per dB and did not vary with carrier frequency. Estimates of latency, however, indicated that latency increased with decreasing carrier frequency and with decreasing intensity. The performance of the threshold estimating algorithms differed between normal hearing and simulated hearing loss, since the amplitude- and phase-intensity functions in the latter condition were not linear. Physiological-behavioral threshold differences were generally greater for normal hearing than for simulated hearing loss. Linear regression provided the least physiological-behavioral difference but was quite variable during simulated hearing loss. Simply defining threshold as the lowest intensity above which all responses were significantly different from residual EEG noise was the most accurate method in terms of yielding the least standard deviation of the physiological-behavioral difference with an average standard deviation of 10 dB, provided EEG noise levels were low enough in the normal hearing condition. Conclusions: Thresholds can be estimated using intensity sweeps with about the same accuracy as recording separate responses to discrete intensities. Sweep recordings provide additional information about the responses at suprathreshold intensities by clearly determining amplitude- and phase- intensity functions at these intensities.
- 17 May 2007
- Published by Taylor & Francis in Developmental Neuropsychology
- Vol. 31 (3) , 249-278
Electrophysiological Evaluation of Human Brain Development
The complex development of the human brain during infancy can only be understood by convergent structural, functional, and behavioral measurements. The evaluation of event-related potentials (ERPs) is the most effective current way to look at infant brain function. ERP paradigms can be used to examine the simple transmission of sensory information to the cortex and the discrimination of this information within the cortex. The main developmental changes involve localization of function as the brain becomes tuned to the experienced world (related to synaptic pruning) and a speeding up of transmission as pathways become efficient (related to myelination). ERPs that occur in relation to different temporal aspects of a stimulus (onset-responses, offset-responses, sustained potentials and steady-state responses) and ERPs recorded at different stimulus rates may help track perceptual development from a temporal perspective. Particularly important in human development are the ERP changes that occur in the processing of speech sounds and human faces. At present, ERP studies can show differences between groups of subjects that can demonstrate developmental disorders or elucidate mechanisms of development. However, because of their variability, ERPs are less helpful in determining whether an individual infant is developing abnormally. Where possible, ERP measurements should be used in conjunction with behavioral tests so as to relate performance to mechanism, and with anatomical brain measurements to relate mechanism to structure.
- 17 May 2007
- Published by Taylor & Francis in Developmental Neuropsychology
- Vol. 31 (3) , 249-278
Electrophysiological Evaluation of Human Brain Development
The complex development of the human brain during infancy can only be understood by convergent structural, functional, and behavioral measurements. The evaluation of event-related potentials (ERPs) is the most effective current way to look at infant brain function. ERP paradigms can be used to examine the simple transmission of sensory information to the cortex and the discrimination of this information within the cortex. The main developmental changes involve localization of function as the brain becomes tuned to the experienced world (related to synaptic pruning) and a speeding up of transmission as pathways become efficient (related to myelination). ERPs that occur in relation to different temporal aspects of a stimulus (onset-responses, offset-responses, sustained potentials and steady-state responses) and ERPs recorded at different stimulus rates may help track perceptual development from a temporal perspective. Particularly important in human development are the ERP changes that occur in the processing of speech sounds and human faces. At present, ERP studies can show differences between groups of subjects that can demonstrate developmental disorders or elucidate mechanisms of development. However, because of their variability, ERPs are less helpful in determining whether an individual infant is developing abnormally. Where possible, ERP measurements should be used in conjunction with behavioral tests so as to relate performance to mechanism, and with anatomical brain measurements to relate mechanism to structure.
- Open Access
- 17 May 2006
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 17 (4) , 826-838
Effects of Focal Frontal Lesions on Response Inhibition
This study examined the performance of 38 normal subjects and 43 patients with focal lesions of the frontal lobes on a simple go–nogo task where the probability of the nogo stimulus was either 75% or 25%. Patients with lesions to the superior medial parts of the frontal lobes, in particular to the left superior portion of Brodmann area 6 (which includes the supplementary motor areas and the premotor areas for the right hand) had an increased number of false alarms (incorrect responses to the nogo stimulus). These results indicate that area 6 is specifically involved in the inhibition of response. Patients with lesions to the right anterior cingulate (areas 24 and 32) were slower and more variable in their reaction time. These findings could be explained by an inability to sustain stimulus-response contingencies. Lesions to the right ventrolateral prefrontal cortex (Brodmann areas 44, 45, 47) also increased the variability of response, perhaps by disrupting monitoring performance.
- 17 May 2006
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 17 (4) , 826-838
Open AccessEffects of Focal Frontal Lesions on Response Inhibition
This study examined the performance of 38 normal subjects and 43 patients with focal lesions of the frontal lobes on a simple go–nogo task where the probability of the nogo stimulus was either 75% or 25%. Patients with lesions to the superior medial parts of the frontal lobes, in particular to the left superior portion of Brodmann area 6 (which includes the supplementary motor areas and the premotor areas for the right hand) had an increased number of false alarms (incorrect responses to the nogo stimulus). These results indicate that area 6 is specifically involved in the inhibition of response. Patients with lesions to the right anterior cingulate (areas 24 and 32) were slower and more variable in their reaction time. These findings could be explained by an inability to sustain stimulus-response contingencies. Lesions to the right ventrolateral prefrontal cortex (Brodmann areas 44, 45, 47) also increased the variability of response, perhaps by disrupting monitoring performance.
- 1 January 2006
- Published by Elsevier in Neuropsychologia
- Vol. 44 (7) , 1195-1209
Keeping time: Effects of focal frontal lesions
- 1 January 2006
- Published by Elsevier in Neuropsychologia
- Vol. 44 (7) , 1195-1209
Keeping time: Effects of focal frontal lesions
- 1 March 2005
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 16 (3) , 140-156
Estimating Audiometric Thresholds Using Auditory Steady-State Responses
Human auditory steady-state responses (ASSRs) were recorded using stimulus rates of 78–95 Hz in normal young subjects, in elderly subjects with relatively normal hearing, and in elderly subjects with sensorineural hearing impairment. Amplitude-intensity functions calculated relative to actual sensory thresholds (sensation level or SL) showed that amplitudes increased as stimulus intensity increased. In the hearing-impaired subjects this increase was more rapid at intensities just above threshold ("electrophysiological recruitment") than at higher intensities where the increase was similar to that seen in normal subjects. The thresholds in dB SL for recognizing an ASSR and the intersubject variability of these thresholds decreased with increasing recording time and were lower in the hearing impaired compared to the normal subjects. After 9.8 minutes of recording, the average ASSR thresholds (and standard deviations) were 12.6 ± 8.7 in the normal subjects, 12.4 ± 11.9 dB in the normal elderly, and 3.6 ± 13.5 dB SL in the hearing-impaired subjects. Se registraron respuestas auditivas de estado estable (ASSR) en humanos, usando una tasa de estímulos de 78-95 Hz en sujetos jóvenes con audicón normal, en sujetos ancianos con una audición relativamente normal, y en sujetos ancianos con un trastorno auditivo sensorineural. Las funciones de amplitud-intensidad calculadas en relación con los umbrales auditivos reales (nivel de sensación o SL) mostraron que las amplitudes aumentan conforme se incrementa la intensidad. En los sujetos hipoacúsicos este incremento fue más rápido en intensidades justo por encima del umbral ("reclutamiento electrofisiológico") que a intensidades mayores, donde el incremento era similar al visto en los sujetos normales. Los umbrales en dB SL para reconocer una ASSR, y la variabilidad inter-sujetos de estos umbrales, disminuyó conforme aumentó el tiempo de registro y fue menor en los sujetos hipoacúsicos, comparada con los normales. Luego de 9.8 minutos de registro, los umbrales promedio de las ASSR (y sus desviaciones estándar) fue de 12.6 ± 8.7 en los sujetos normales, 12.4 ± 11.9 dB en los ancianos normales y 3.6 ± 13.5 dB SL en los sujetos hipoacúsicos.
- 1 March 2005
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 16 (3) , 140-156
Estimating Audiometric Thresholds Using Auditory Steady-State Responses
Human auditory steady-state responses (ASSRs) were recorded using stimulus rates of 78–95 Hz in normal young subjects, in elderly subjects with relatively normal hearing, and in elderly subjects with sensorineural hearing impairment. Amplitude-intensity functions calculated relative to actual sensory thresholds (sensation level or SL) showed that amplitudes increased as stimulus intensity increased. In the hearing-impaired subjects this increase was more rapid at intensities just above threshold ("electrophysiological recruitment") than at higher intensities where the increase was similar to that seen in normal subjects. The thresholds in dB SL for recognizing an ASSR and the intersubject variability of these thresholds decreased with increasing recording time and were lower in the hearing impaired compared to the normal subjects. After 9.8 minutes of recording, the average ASSR thresholds (and standard deviations) were 12.6 ± 8.7 in the normal subjects, 12.4 ± 11.9 dB in the normal elderly, and 3.6 ± 13.5 dB SL in the hearing-impaired subjects. Se registraron respuestas auditivas de estado estable (ASSR) en humanos, usando una tasa de estímulos de 78-95 Hz en sujetos jóvenes con audicón normal, en sujetos ancianos con una audición relativamente normal, y en sujetos ancianos con un trastorno auditivo sensorineural. Las funciones de amplitud-intensidad calculadas en relación con los umbrales auditivos reales (nivel de sensación o SL) mostraron que las amplitudes aumentan conforme se incrementa la intensidad. En los sujetos hipoacúsicos este incremento fue más rápido en intensidades justo por encima del umbral ("reclutamiento electrofisiológico") que a intensidades mayores, donde el incremento era similar al visto en los sujetos normales. Los umbrales en dB SL para reconocer una ASSR, y la variabilidad inter-sujetos de estos umbrales, disminuyó conforme aumentó el tiempo de registro y fue menor en los sujetos hipoacúsicos, comparada con los normales. Luego de 9.8 minutos de registro, los umbrales promedio de las ASSR (y sus desviaciones estándar) fue de 12.6 ± 8.7 en los sujetos normales, 12.4 ± 11.9 dB en los ancianos normales y 3.6 ± 13.5 dB SL en los sujetos hipoacúsicos.
- 1 September 2004
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 15 (8) , 541-554
Avoiding Electromagnetic Artifacts When Recording Auditory Steady-State Responses
Electromagnetic artifacts can occur when recording multiple auditory steady-state responses evoked by sinusoidally amplitude modulated (SAM) stimuli. High-intensity air-conducted stimuli evoked responses even when hearing was prevented by masking. Additionally, high-intensity bone-conducted stimuli evoked responses that were completely different from those evoked by air-conducted stimuli of similar sensory level. These artifacts were caused by aliasing since they did not occur when recordings used high analog-digital (AD) conversion rates or when high frequencies in the electroencephalographic (EEG) signal were attenuated by steep-slope low-pass filtering. Two possible techniques can displace aliased energy away from the response frequencies: (1) using an AD rate that is not an integer submultiple of the carrier frequencies and (2) using stimuli with frequency spectra that do not alias back to the response frequencies, such as beats or "alternating SAM" tones. Alternating SAM tones evoke responses similar to conventional SAM tones, whereas beats produce significantly smaller responses. Cuando se realizan registros múltiples de respuestas auditivas de estado estable, evocadas por medio de estímulos sinusoidales de amplitud modulada (SAM), se pueden generar artefactos electromagnéticos. Los estímulos por v[ia aérea de alta intensidad evocan estas respuestas aún cuando se enmascare la audición. Además, los estímulos de alta intensidad conducidos por vía ósea también evocaron respuestas que fueron completamente diferentes de aquellas por vía aérea, a niveles sensoriales similares. Estos artefactos fueron causados por relación, dado que no se presentaron cuando los registros se hicieron utilizando tasas altas de conversión analógico-digital (AD), o cuando las frecuencias en la señal electroencefalográfica (EEG) fueron atenuadas por filtros. Existen dos posibles técnicas para desplazar esta energía relacionada de las frecuencias de respuesta: (1) usando una tasa AD que no sea sub-múltiplo entero de las frecuencias portadoras, y (2) usando estímulos con un espectro de frecuencia que no esté relacionado con las frecuencias de la respuesta, tales como las pulsaciones o los tonos SAM alternantes. Los tonos SAM alternantes evocan respuestas similares a los tonos SAM convencionales, mientras que las pulsaciones producen respuestas significativamente menores.
- 1 September 2004
- Published by American Academy of Audiology in Journal of the American Academy of Audiology
- Vol. 15 (8) , 541-554
Avoiding Electromagnetic Artifacts When Recording Auditory Steady-State Responses
Electromagnetic artifacts can occur when recording multiple auditory steady-state responses evoked by sinusoidally amplitude modulated (SAM) stimuli. High-intensity air-conducted stimuli evoked responses even when hearing was prevented by masking. Additionally, high-intensity bone-conducted stimuli evoked responses that were completely different from those evoked by air-conducted stimuli of similar sensory level. These artifacts were caused by aliasing since they did not occur when recordings used high analog-digital (AD) conversion rates or when high frequencies in the electroencephalographic (EEG) signal were attenuated by steep-slope low-pass filtering. Two possible techniques can displace aliased energy away from the response frequencies: (1) using an AD rate that is not an integer submultiple of the carrier frequencies and (2) using stimuli with frequency spectra that do not alias back to the response frequencies, such as beats or "alternating SAM" tones. Alternating SAM tones evoke responses similar to conventional SAM tones, whereas beats produce significantly smaller responses. Cuando se realizan registros múltiples de respuestas auditivas de estado estable, evocadas por medio de estímulos sinusoidales de amplitud modulada (SAM), se pueden generar artefactos electromagnéticos. Los estímulos por v[ia aérea de alta intensidad evocan estas respuestas aún cuando se enmascare la audición. Además, los estímulos de alta intensidad conducidos por vía ósea también evocaron respuestas que fueron completamente diferentes de aquellas por vía aérea, a niveles sensoriales similares. Estos artefactos fueron causados por relación, dado que no se presentaron cuando los registros se hicieron utilizando tasas altas de conversión analógico-digital (AD), o cuando las frecuencias en la señal electroencefalográfica (EEG) fueron atenuadas por filtros. Existen dos posibles técnicas para desplazar esta energía relacionada de las frecuencias de respuesta: (1) usando una tasa AD que no sea sub-múltiplo entero de las frecuencias portadoras, y (2) usando estímulos con un espectro de frecuencia que no esté relacionado con las frecuencias de la respuesta, tales como las pulsaciones o los tonos SAM alternantes. Los tonos SAM alternantes evocan respuestas similares a los tonos SAM convencionales, mientras que las pulsaciones producen respuestas significativamente menores.
- 1 November 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 97 (5) , 1396-1402
Human Auditory Steady-State Responses: The Effects of Recording Technique and State of Arousal
There is some controversy in the literature about whether auditory steady-state responses (ASSRs) can be reliably recorded in all subjects and whether these responses consistently decrease in amplitude during drowsiness. In 10 subjects, 40-Hz ASSRs became significantly different from background elec
- 1 November 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 97 (5) , 1396-1402
Human Auditory Steady-State Responses: The Effects of Recording Technique and State of Arousal
There is some controversy in the literature about whether auditory steady-state responses (ASSRs) can be reliably recorded in all subjects and whether these responses consistently decrease in amplitude during drowsiness. In 10 subjects, 40-Hz ASSRs became significantly different from background elec
- 14 August 2001
- Published by Elsevier in Clinical Neurophysiology
- Vol. 112 (9) , 1698-1711
The use of phase in the detection of auditory steady-state responses
- 14 August 2001
- Published by Elsevier in Clinical Neurophysiology
- Vol. 112 (9) , 1698-1711
The use of phase in the detection of auditory steady-state responses