Josef Plášek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Josef Plášek has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ondrej Sikula
Faculty of Civil Engineering
8 shared publications - Jiří Hirš
Brno University of Technology
4 shared publications - Jitka Mohelníková
Faculty of Civil Engineering, Brno University of Technology, Veveří 95, 602 00 Brno, Czech Republic
2 shared publications Ondřej Hnilica
2 shared publicationsGünter Gebauer
1 shared publicationJiri Sima
1 shared publication
Latest Publications
- Open Access
- 13 August 2019
- Published by EDP Sciences
- Vol. 111
Indoor Climate in Jesuit Church of Holy Name of Jesus in Telc
- 13 August 2019
- Published by EDP Sciences
- Vol. 111
Open AccessIndoor Climate in Jesuit Church of Holy Name of Jesus in Telc
- Open Access
- 1 March 2016
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 94, 403-410
Experimental analysis of steam condensation in vertical tube with small diameter
- 1 March 2016
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 94, 403-410
Open AccessExperimental analysis of steam condensation in vertical tube with small diameter
- Open Access
- 1 August 2015
- Published by Elsevier in Energy Procedia
- Vol. 74, 177-183
Hybrid Roof Panels for Night Cooling and Solar Energy Utilization in Buildings
- 1 August 2015
- Published by Elsevier in Energy Procedia
- Vol. 74, 177-183
Open AccessHybrid Roof Panels for Night Cooling and Solar Energy Utilization in Buildings
- Open Access
- 1 December 2014
- Published by Elsevier in Energy and Buildings
- Vol. 85, 436-444
Thermal analysis of light pipes for insulated flat roofs
- 1 December 2014
- Published by Elsevier in Energy and Buildings
- Vol. 85, 436-444
Open AccessThermal analysis of light pipes for insulated flat roofs
- 27 October 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1041, 277-280
Transient Numerical Simulation of Linear Thermal Transmittance in Software CalA
Calculation of heat losses of buildings according to European standard EN ISO 10211 and Czech standard ČSN 73 0540 is simplified to one-dimensional time-steady heat conduction through the building construction in direction of the largest temperature gradient. This simplification of the calculation is incorrect in case of complex geometry. Calculation according to norm takes into account this inaccuracy and uses Linear Thermal Transmittance Ψ [W/(m·K)] in 2D geometry or Point Thermal Transmittance χ [W/(m2·K)] in the 3D geometry as a calculation correction. This contribution is focused on detailed calculation of linear thermal transmittance in case of contact external peripheral wall and plastic window frame. Results of two-dimensional transient numerical simulation show unsteady linear thermal transmittance in time and dependence on solar radiation. All of these variable boundary conditions can be easily simulated in the software CalA as well as complex geometry.
- 27 October 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 1041, 277-280
Transient Numerical Simulation of Linear Thermal Transmittance in Software CalA
Calculation of heat losses of buildings according to European standard EN ISO 10211 and Czech standard ČSN 73 0540 is simplified to one-dimensional time-steady heat conduction through the building construction in direction of the largest temperature gradient. This simplification of the calculation is incorrect in case of complex geometry. Calculation according to norm takes into account this inaccuracy and uses Linear Thermal Transmittance Ψ [W/(m·K)] in 2D geometry or Point Thermal Transmittance χ [W/(m2·K)] in the 3D geometry as a calculation correction. This contribution is focused on detailed calculation of linear thermal transmittance in case of contact external peripheral wall and plastic window frame. Results of two-dimensional transient numerical simulation show unsteady linear thermal transmittance in time and dependence on solar radiation. All of these variable boundary conditions can be easily simulated in the software CalA as well as complex geometry.
- Open Access
- 1 January 2014
- Published by Elsevier in Energy Procedia
- Vol. 48, 645-653
Theoretical Evaluation of Night Sky Cooling in the Czech Republic
- 1 January 2014
- Published by Elsevier in Energy Procedia
- Vol. 48, 645-653
Open AccessTheoretical Evaluation of Night Sky Cooling in the Czech Republic
- Open Access
Thermal CFD Analysis of Tubular Light Guides
Tubular light guides are applicable for daylighting of windowless areas in buildings. Despite their many positive indoor climate aspects they can also present some problems with heat losses and condensation. A computer CFD model focused on the evaluation of temperature distribution and air flow inside tubular light guides of different dimensions was studied. The physical model of the tested light guides of lengths more than 0.60 m proves shows that Rayleigh numbers are adequate for a turbulent air flow. The turbulent model was applied despite the small heat flux differences between the turbulent and laminar model. The CFD simulations resulted into conclusions that the growing ratio of length/diameter increases the heat transmission loss/linear transmittance as much as by 50 percent. Tubular light guides of smaller diameters have lower heat transmission losses compared to the wider ones of the same lengths with the same outdoor temperature being taken into account. The simulation results confirmed the thermal bridge effect of the tubular light guide tube inside the insulated flat roof details. The thermal transmittance of the studied light guides in the whole roof area was substituted with the point thermal bridges. This substitution gives possibility for simple thermal evaluation of the tubular light pipes in roof constructions.
Open AccessThermal CFD Analysis of Tubular Light Guides
Tubular light guides are applicable for daylighting of windowless areas in buildings. Despite their many positive indoor climate aspects they can also present some problems with heat losses and condensation. A computer CFD model focused on the evaluation of temperature distribution and air flow inside tubular light guides of different dimensions was studied. The physical model of the tested light guides of lengths more than 0.60 m proves shows that Rayleigh numbers are adequate for a turbulent air flow. The turbulent model was applied despite the small heat flux differences between the turbulent and laminar model. The CFD simulations resulted into conclusions that the growing ratio of length/diameter increases the heat transmission loss/linear transmittance as much as by 50 percent. Tubular light guides of smaller diameters have lower heat transmission losses compared to the wider ones of the same lengths with the same outdoor temperature being taken into account. The simulation results confirmed the thermal bridge effect of the tubular light guide tube inside the insulated flat roof details. The thermal transmittance of the studied light guides in the whole roof area was substituted with the point thermal bridges. This substitution gives possibility for simple thermal evaluation of the tubular light pipes in roof constructions.
- Open Access
- 1 January 2013
- Published by Elsevier in Energy Procedia
- Vol. 36, 1070-1075
The Effect of Shielding Barriers on Solar Air Collector Gains
- 1 January 2013
- Published by Elsevier in Energy Procedia
- Vol. 36, 1070-1075
Open AccessThe Effect of Shielding Barriers on Solar Air Collector Gains
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 649, 105-108
Problematic of Humidity Degradation of Plaster with Indoor Fresco Decoration in Romanesque Rotunda in Znojmo
The paper is based on measured and approximated data of internal climate in Romanesque rotunda in Znojmo. It deals with degradation of indoor plaster with fresco decoration due to air humidity. The most probable conditions of internal climate are shown and evaluated in psychometrics chart. Therefore, it is possible to assume ways of plaster degradation from the obtained thermal-moisture conditions of the indoor climate.
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 649, 105-108
Problematic of Humidity Degradation of Plaster with Indoor Fresco Decoration in Romanesque Rotunda in Znojmo
The paper is based on measured and approximated data of internal climate in Romanesque rotunda in Znojmo. It deals with degradation of indoor plaster with fresco decoration due to air humidity. The most probable conditions of internal climate are shown and evaluated in psychometrics chart. Therefore, it is possible to assume ways of plaster degradation from the obtained thermal-moisture conditions of the indoor climate.
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 284-287, 483-487
Maximization of Solar Gains of an Air Collector by Simulations
The paper deals with numerical simulations of the impact of design, shading, positioning and orientation of a solar air collector an efficiency of exploitation of solar energy. The solar collector is used to preheat of an air, which then is supplied into the building. There are various requirements for solar air collectors. We are focused on maximization of solar energy gain by optimizing geometry, orientation and positioning of a solar air collector. To achieve the desired objective was a combination of two methods used. The firs one is Computational Fluid Dynamics (CFD) simulations of flow and heat transfer by convection, conduction and radiation in software ANSYS Fluent. The second one is the numerical simulation of the annual operations of the collector in the software BSim. The result of this work is an optimal design and operation conditions of the air collector.
- 1 January 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 284-287, 483-487
Maximization of Solar Gains of an Air Collector by Simulations
The paper deals with numerical simulations of the impact of design, shading, positioning and orientation of a solar air collector an efficiency of exploitation of solar energy. The solar collector is used to preheat of an air, which then is supplied into the building. There are various requirements for solar air collectors. We are focused on maximization of solar energy gain by optimizing geometry, orientation and positioning of a solar air collector. To achieve the desired objective was a combination of two methods used. The firs one is Computational Fluid Dynamics (CFD) simulations of flow and heat transfer by convection, conduction and radiation in software ANSYS Fluent. The second one is the numerical simulation of the annual operations of the collector in the software BSim. The result of this work is an optimal design and operation conditions of the air collector.