Young-Min Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Young-Min Kim has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Dong Gil Shin
Research Division of Environmental and Energy Systems, Korea Institute of Machinery and Materials, 156 Gajeongbuk-ro, Yuseong-gu, Daejeon 34104, Korea
3 shared publications - Chang-Gi Kim
Department of Environmental and Energy Systems, Korea Institute of Machinery and Materials, 156 Gajeongbuk-ro, Yuseong-gu, Daejeon 34104, Korea
2 shared publications - Gyubaek Cho
Research Division of Environmental and Energy Systems, Korea Institute of Machinery and Materials, 156 Gajeongbuk-ro, Yuseong-gu, Daejeon 34104, Korea
2 shared publications - Assmelash A. Negash
Environment & Energy Mechanical Engineering, Korea University of Science and Technology, 217 Gajeong-ro, Yuseong-gu, Daejeon 34113, Korea
1 shared publication - Assmelash Negash
Research Division of Environmental and Energy Systems, Korea Institute of Machinery and Materials, 156 Gajeongbuk-ro, Yuseong-gu, Daejeon 34104, Korea
1 shared publication - Daniel Favrat
EPFL-LENI (Industrial Energy Systems Laboratory), ME A2, Station 9, CH-1015 Lausanne, Switzerland
1 shared publication
Latest Publications
- 30 December 2022
- Published by The Korean Society of Marine Environment and Safety in Journal of the Korean Society of Marine Environment & Safety
- Vol. 28 (7) , 1252-1258
Preliminary Experimental Study for Water Recovery and Particulate Matter Reduction through a Hybrid System that Combines Exhaust Cooling and Absorption from Ships
- 30 December 2022
- Published by The Korean Society of Marine Environment and Safety in Journal of the Korean Society of Marine Environment & Safety
- Vol. 28 (7) , 1252-1258
Preliminary Experimental Study for Water Recovery and Particulate Matter Reduction through a Hybrid System that Combines Exhaust Cooling and Absorption from Ships
- Open Access
Parametric Study of a Supercritical CO2 Power Cycle for Waste Heat Recovery with Variation in Cold Temperature and Heat Source Temperature
The supercritical carbon dioxide (S-CO2) power cycle is a promising development for waste heat recovery (WHR) due to its high efficiency despite its simplicity and compactness compared with a steam bottoming cycle. A simple recuperated S-CO2 power cycle cannot fully utilize the waste heat due to the trade-off between the heat recovery and thermal efficiency of the cycle. A split cycle in which the working fluid is preheated by the recuperator and the heat source separately can be used to maximize the power output from a given waste heat source. In this study, the operating conditions of split S-CO2 power cycles for waste heat recovery from a gas turbine and an engine were studied to accommodate the temperature variation of the heat sink and the waste heat source. The results show that it is vital to increase the low pressure of the cycle along with a corresponding increase in the cooling temperature to maintain the low-compression work near the critical point. The net power decreases by 6 to 9% for every 5 °C rise in the cooling temperature from 20 to 50 °C due to the decrease in heat recovery and thermal efficiency of the cycle. The effect of the heat-source temperature on the optimal low-pressure side was negligible, and the optimal high pressure of the cycle increased with an increase in the heat-source temperature. As the heat-source temperature increased in steps of 50 °C from 300 to 400 °C, the system efficiency increased by approximately 2% (absolute efficiency), and the net power significantly increased by 30 to 40%.
Open AccessParametric Study of a Supercritical CO2 Power Cycle for Waste Heat Recovery with Variation in Cold Temperature and Heat Source Temperature
The supercritical carbon dioxide (S-CO2) power cycle is a promising development for waste heat recovery (WHR) due to its high efficiency despite its simplicity and compactness compared with a steam bottoming cycle. A simple recuperated S-CO2 power cycle cannot fully utilize the waste heat due to the trade-off between the heat recovery and thermal efficiency of the cycle. A split cycle in which the working fluid is preheated by the recuperator and the heat source separately can be used to maximize the power output from a given waste heat source. In this study, the operating conditions of split S-CO2 power cycles for waste heat recovery from a gas turbine and an engine were studied to accommodate the temperature variation of the heat sink and the waste heat source. The results show that it is vital to increase the low pressure of the cycle along with a corresponding increase in the cooling temperature to maintain the low-compression work near the critical point. The net power decreases by 6 to 9% for every 5 °C rise in the cooling temperature from 20 to 50 °C due to the decrease in heat recovery and thermal efficiency of the cycle. The effect of the heat-source temperature on the optimal low-pressure side was negligible, and the optimal high pressure of the cycle increased with an increase in the heat-source temperature. As the heat-source temperature increased in steps of 50 °C from 300 to 400 °C, the system efficiency increased by approximately 2% (absolute efficiency), and the net power significantly increased by 30 to 40%.
- Open Access
Experimental Study of a Lab-Scale Organic Rankine Cycle System for Heat and Water Recovery from Flue Gas in Thermal Power Plants
Fossil fuel power plants can cause numerous environmental issues, owing to exhaust emissions and substantial water consumption. In a thermal power plant, heat and water recovery from flue gas can reduce CO2 emissions and water demand. High-humidity flue gas averts the diffusion of pollutants, enhances the secondary transformation of air pollutants, and leads to smog weather; hence, water recovery from flue gas can also help to lessen the incidence of white plumes and smog near and around the power plant. In this study, a lab-scale system for heat and water recovery from flue gas was tested. The flue gas was initially cooled by an organic Rankine cycle (ORC) system to produce power. This gas was further cooled by an aftercooler, using the same working fluid to condense the water and condensable particulate matter in the flue gas. The ORC system can produce approximately 220 W of additional power from flue gas at 140 °C, with a thermal efficiency of 10%. By cooling the flue gas below 30–40 °C, the aftercooler can recover 60% of the water in it.
Open AccessExperimental Study of a Lab-Scale Organic Rankine Cycle System for Heat and Water Recovery from Flue Gas in Thermal Power Plants
Fossil fuel power plants can cause numerous environmental issues, owing to exhaust emissions and substantial water consumption. In a thermal power plant, heat and water recovery from flue gas can reduce CO2 emissions and water demand. High-humidity flue gas averts the diffusion of pollutants, enhances the secondary transformation of air pollutants, and leads to smog weather; hence, water recovery from flue gas can also help to lessen the incidence of white plumes and smog near and around the power plant. In this study, a lab-scale system for heat and water recovery from flue gas was tested. The flue gas was initially cooled by an organic Rankine cycle (ORC) system to produce power. This gas was further cooled by an aftercooler, using the same working fluid to condense the water and condensable particulate matter in the flue gas. The ORC system can produce approximately 220 W of additional power from flue gas at 140 °C, with a thermal efficiency of 10%. By cooling the flue gas below 30–40 °C, the aftercooler can recover 60% of the water in it.
- Open Access
- 28 March 2019
- Published by MDPI AG in Sustainability
- Vol. 11 (7) , 1881
Waste Heat and Water Recovery System Optimization for Flue Gas in Thermal Power Plants
Fossil-fueled power plants present a problem of significant water consumption, carbon dioxide emissions, and environmental pollution. Several techniques have been developed to utilize flue gas, which can help solve these problems. Among these, the ones focusing on energy extraction beyond the dew point of the moisture present within the flue gas are quite attractive. In this study, a novel waste heat and water recovery system (WHWRS) composed of an organic Rankine cycle (ORC) and cooling cycles using singular working fluid accompanied by phase change was proposed and optimized for maximum power output. Furthermore, WHWRS configurations were analyzed for fixed water yield and fixed ambient temperature, covering possible trade-off scenarios between power loss and the number of stages as per desired yields of water recovery at ambient temperatures in a practical range. For a 600 MW power plant with 16% water vapor volume in flue gas at 150 °C, the WHWRS can produce 4–6 MWe while recovering 50% water by cooling the flue gas to 40 °C at an ambient temperature of 20 °C. Pragmatic results and design flexibility, while utilizing single working fluid, makes this proposed system a desirable candidate for practical application.
- 28 March 2019
- Published by MDPI AG in Sustainability
- Vol. 11 (7) , 1881
Open AccessWaste Heat and Water Recovery System Optimization for Flue Gas in Thermal Power Plants
Fossil-fueled power plants present a problem of significant water consumption, carbon dioxide emissions, and environmental pollution. Several techniques have been developed to utilize flue gas, which can help solve these problems. Among these, the ones focusing on energy extraction beyond the dew point of the moisture present within the flue gas are quite attractive. In this study, a novel waste heat and water recovery system (WHWRS) composed of an organic Rankine cycle (ORC) and cooling cycles using singular working fluid accompanied by phase change was proposed and optimized for maximum power output. Furthermore, WHWRS configurations were analyzed for fixed water yield and fixed ambient temperature, covering possible trade-off scenarios between power loss and the number of stages as per desired yields of water recovery at ambient temperatures in a practical range. For a 600 MW power plant with 16% water vapor volume in flue gas at 150 °C, the WHWRS can produce 4–6 MWe while recovering 50% water by cooling the flue gas to 40 °C at an ambient temperature of 20 °C. Pragmatic results and design flexibility, while utilizing single working fluid, makes this proposed system a desirable candidate for practical application.
- Open Access
On-Board Cold Thermal Energy Storage System for Hydrogen Fueling Process
The hydrogen storage pressure in fuel cell vehicles has been increased from 35 MPa to 70 MPa in order to accommodate longer driving range. On the downside, such pressure increase results in significant temperature rise inside the hydrogen tank during fast filling at a fueling station, which may pose safety issues. Installation of a chiller often mitigates this concern because it cools the hydrogen gas before its deposition into the tank. To address both the energy efficiency improvement and safety concerns, this paper proposed an on-board cold thermal energy storage (CTES) system, cooled by expanded hydrogen. During the driving cycle, the proposed system uses an expander, instead of a pressure regulator, to generate additional power and cold hydrogen gas. Moreover, CTES is equipped with phase change materials (PCM) to recover the cold energy of the expanded hydrogen gas, which is later used in the next filling to cool the high-pressure hydrogen gas from the fueling station.
Open AccessOn-Board Cold Thermal Energy Storage System for Hydrogen Fueling Process
The hydrogen storage pressure in fuel cell vehicles has been increased from 35 MPa to 70 MPa in order to accommodate longer driving range. On the downside, such pressure increase results in significant temperature rise inside the hydrogen tank during fast filling at a fueling station, which may pose safety issues. Installation of a chiller often mitigates this concern because it cools the hydrogen gas before its deposition into the tank. To address both the energy efficiency improvement and safety concerns, this paper proposed an on-board cold thermal energy storage (CTES) system, cooled by expanded hydrogen. During the driving cycle, the proposed system uses an expander, instead of a pressure regulator, to generate additional power and cold hydrogen gas. Moreover, CTES is equipped with phase change materials (PCM) to recover the cold energy of the expanded hydrogen gas, which is later used in the next filling to cool the high-pressure hydrogen gas from the fueling station.
- Open Access
Optimization of Design Pressure Ratio of Positive Displacement Expander for Vehicle Engine Waste Heat Recovery
This study investigated the effect of the built-in volume ratio of an expander on the performance of a dual-loop Rankine cycle system for the engine waste heat recovery of a vehicle. Varying vehicle operating conditions can cause a positive displacement expander to operate in both under- and over-expansion states. Therefore, analysis of the off-design performance of the expander is very important. Furthermore, the volume and weight of the expander must be considered in its optimization along with the efficiency. A simple modeling of the off-design operation of the expander showed that a built-in volume ratio that causes under-expansion rather than over-expansion at the target condition is more desirable.
Open AccessOptimization of Design Pressure Ratio of Positive Displacement Expander for Vehicle Engine Waste Heat Recovery
This study investigated the effect of the built-in volume ratio of an expander on the performance of a dual-loop Rankine cycle system for the engine waste heat recovery of a vehicle. Varying vehicle operating conditions can cause a positive displacement expander to operate in both under- and over-expansion states. Therefore, analysis of the off-design performance of the expander is very important. Furthermore, the volume and weight of the expander must be considered in its optimization along with the efficiency. A simple modeling of the off-design operation of the expander showed that a built-in volume ratio that causes under-expansion rather than over-expansion at the target condition is more desirable.
- Open Access
Potential and Evolution of Compressed Air Energy Storage: Energy and Exergy Analyses
Energy storage systems are increasingly gaining importance with regard to their role in achieving load levelling, especially for matching intermittent sources of renewable energy with customer demand, as well as for storing excess nuclear or thermal power during the daily cycle. Compressed air energy storage (CAES), with its high reliability, economic feasibility, and low environmental impact, is a promising method for large-scale energy storage. Although there are only two large-scale CAES plants in existence, recently, a number of CAES projects have been initiated around the world, and some innovative concepts of CAES have been proposed. Existing CAES plants have some disadvantages such as energy loss due to dissipation of heat of compression, use of fossil fuels, and dependence on geological formations. This paper reviews the main drawbacks of the existing CAES systems and presents some innovative concepts of CAES, such as adiabatic CAES, isothermal CAES, micro-CAES combined with air-cycle heating and cooling, and constant-pressure CAES combined with pumped hydro storage that can address such problems and widen the scope of CAES applications, by energy and exergy analyses. These analyses greatly help us to understand the characteristics of each CAES system and compare different CAES systems.
Open AccessPotential and Evolution of Compressed Air Energy Storage: Energy and Exergy Analyses
Energy storage systems are increasingly gaining importance with regard to their role in achieving load levelling, especially for matching intermittent sources of renewable energy with customer demand, as well as for storing excess nuclear or thermal power during the daily cycle. Compressed air energy storage (CAES), with its high reliability, economic feasibility, and low environmental impact, is a promising method for large-scale energy storage. Although there are only two large-scale CAES plants in existence, recently, a number of CAES projects have been initiated around the world, and some innovative concepts of CAES have been proposed. Existing CAES plants have some disadvantages such as energy loss due to dissipation of heat of compression, use of fossil fuels, and dependence on geological formations. This paper reviews the main drawbacks of the existing CAES systems and presents some innovative concepts of CAES, such as adiabatic CAES, isothermal CAES, micro-CAES combined with air-cycle heating and cooling, and constant-pressure CAES combined with pumped hydro storage that can address such problems and widen the scope of CAES applications, by energy and exergy analyses. These analyses greatly help us to understand the characteristics of each CAES system and compare different CAES systems.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-6
Compressed Air Energy Storage Units for Power Generation and DSM in Korea
In this paper, we discuss compressed air energy storage (CAES) units, and reflect on a demand-side management (DSM) technique including six generic load shape objectives in the Korea electric power corporation (KEPCO). The CAES technology has been considered for substitute energy utilization not only in regards to the management of large or small loads but also for use by emergency generators during a power failure. Recently, in the energy storage field, countries with CAES have developed small, medium and large units for storage roles. These units can be used for the dual-purpose applications of supplementary power generation and district heating supply systems. These units have an underground cavern or a modular-type pressurized vessel with large and small, micro containers. The storage and utilization time of the CAES are determined by the power between the lower limit and upper limit by the KEPCO load curve patterns over an entire day.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-6
Compressed Air Energy Storage Units for Power Generation and DSM in Korea
In this paper, we discuss compressed air energy storage (CAES) units, and reflect on a demand-side management (DSM) technique including six generic load shape objectives in the Korea electric power corporation (KEPCO). The CAES technology has been considered for substitute energy utilization not only in regards to the management of large or small loads but also for use by emergency generators during a power failure. Recently, in the energy storage field, countries with CAES have developed small, medium and large units for storage roles. These units can be used for the dual-purpose applications of supplementary power generation and district heating supply systems. These units have an underground cavern or a modular-type pressurized vessel with large and small, micro containers. The storage and utilization time of the CAES are determined by the power between the lower limit and upper limit by the KEPCO load curve patterns over an entire day.