Yong Tae Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yong Tae Yoon has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Jong-Keun Park
Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea
6 shared publications - Minh Y. Nguyen
Department of Electrical and Computer Engineering, Faculty of International Training , Thai Nguyen University of Technology, Thai Nguyen University , Thai Nguyen , Viet Nam
6 shared publications - Sang-Seung Lee
Member, Korea Electrical Engineering and Science Research Institute (KESRI), 130-Dong, Seoul National University, Seoul, 151-742, Korea
5 shared publications - Seung-Il Moon
Department of Electrical and Computer Engineering, Seoul National University, 1 Gwanak-ro, Seoul 08826, Korea
4 shared publications - Yu-Chang Kim
School of Electrical Eng, 301Dong, Seoul National University, Seoul, 151-742, Korea
4 shared publications - Jong-Kyu Park
Seoul National University
3 shared publications
Latest Publications
- 1 March 2018
- Published by Walter de Gruyter GmbH
A New Method for Static Voltage Stability Assessment based on The Local Loadability Boundary
This paper proposes a new method for assessing static voltage stability based on the local loadability boundary or P- Q curve in two dimensional power parameter space. The proposed method includes three main steps. The first step is to determine the critical buses and the second step is building the local loadability boundary or the saddle node bifurcation set for those critical buses. The final step is assessing the static voltage stability through the distance from current operating point to the boundary. The critical buses are defined through the right eigenvector by direct method. The boundary obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system is a quadratic curve. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it keeps the advantages of both efficient methods, the accuracy of the direct method and simple of Thevenin Equivalent based method. Thus, the proposed method holds some promise in terms of performing the real time voltage stability assessment of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.
- 1 March 2018
- Published by Walter de Gruyter GmbH
A New Method for Static Voltage Stability Assessment based on The Local Loadability Boundary
This paper proposes a new method for assessing static voltage stability based on the local loadability boundary or P- Q curve in two dimensional power parameter space. The proposed method includes three main steps. The first step is to determine the critical buses and the second step is building the local loadability boundary or the saddle node bifurcation set for those critical buses. The final step is assessing the static voltage stability through the distance from current operating point to the boundary. The critical buses are defined through the right eigenvector by direct method. The boundary obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system is a quadratic curve. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it keeps the advantages of both efficient methods, the accuracy of the direct method and simple of Thevenin Equivalent based method. Thus, the proposed method holds some promise in terms of performing the real time voltage stability assessment of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.
- Open Access
Designing Structure-Dependent MPC-Based AGC Schemes Considering Network Topology
This paper presents the important features of structure-dependent model predictive control (MPC)-based approaches for automatic generation control (AGC) considering network topology. Since power systems have various generators under different topologies, it is necessary to reflect the characteristics of generators in power networks and the control system structures in order to improve the dynamic performance of AGC. Specifically, considering control system structures is very important because not only can the topological problems be reduced, but also a computing system for AGC in a bulk-power system can be realized. Based on these considerations, we propose new schemes in the proposed controller for minimizing inadvertent line flows and computational burden, which strengthen the advantages of MPC-based approach for AGC. Analysis and simulation results in the IEEE 39-bus model system show different dynamic behaviors among structure-dependent control schemes and possible improvements in computational burden via the proposed control scheme while system operators in each balancing area consider physical load reference ramp constraints among generators.
Open AccessDesigning Structure-Dependent MPC-Based AGC Schemes Considering Network Topology
This paper presents the important features of structure-dependent model predictive control (MPC)-based approaches for automatic generation control (AGC) considering network topology. Since power systems have various generators under different topologies, it is necessary to reflect the characteristics of generators in power networks and the control system structures in order to improve the dynamic performance of AGC. Specifically, considering control system structures is very important because not only can the topological problems be reduced, but also a computing system for AGC in a bulk-power system can be realized. Based on these considerations, we propose new schemes in the proposed controller for minimizing inadvertent line flows and computational burden, which strengthen the advantages of MPC-based approach for AGC. Analysis and simulation results in the IEEE 39-bus model system show different dynamic behaviors among structure-dependent control schemes and possible improvements in computational burden via the proposed control scheme while system operators in each balancing area consider physical load reference ramp constraints among generators.
- 1 March 2015
- Published by The Korean Institute of Electrical Engineers in Journal of Electrical Engineering & Technology
- Vol. 10 (2) , 511-517
A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance
- 1 March 2015
- Published by The Korean Institute of Electrical Engineers in Journal of Electrical Engineering & Technology
- Vol. 10 (2) , 511-517
A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance
- 13 March 2014
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 42 (6) , 585-594
A Comparison of Microgrid Topologies Considering Both Market Operations and Reliability
This article investigates and compares various types of microgrids in the literature. The comparison is concerned with the economic operation of the micro-sources employed in different topologies and the reliability of the end-users. Also, the effect of each component on the performance of the overall microgrid is discussed in detail, e.g., the individual and centralized power converters, etc. The numerical simulation of a case study shows that the single AC and three wire network microgrid types are predominant over two others, namely single DC and hybrid AC-DC networks. The AC microgrid shows its benefits in market operations, while the three-wire network takes advantage of customizing loads as its reliability preferences. The DC microgrid is the worst case, suffering from high power losses and poor reliability.
- 13 March 2014
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 42 (6) , 585-594
A Comparison of Microgrid Topologies Considering Both Market Operations and Reliability
This article investigates and compares various types of microgrids in the literature. The comparison is concerned with the economic operation of the micro-sources employed in different topologies and the reliability of the end-users. Also, the effect of each component on the performance of the overall microgrid is discussed in detail, e.g., the individual and centralized power converters, etc. The numerical simulation of a case study shows that the single AC and three wire network microgrid types are predominant over two others, namely single DC and hybrid AC-DC networks. The AC microgrid shows its benefits in market operations, while the three-wire network takes advantage of customizing loads as its reliability preferences. The DC microgrid is the worst case, suffering from high power losses and poor reliability.
- 6 February 2014
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 9 (2) , 129-135
Optimal scheduling and operation of battery/wind generation system in response to real‐time market prices
This paper addresses the scheduling and operation problem of a combined battery and wind generation system (BWGS) in real‐time market. The proposed operation scheme consists of two control mechanisms: (i) offline scheduling according to the estimation of the market prices and the stochastic information of wind generation, and (ii) online dispatching based on the updated system state in real time. The analysis in this paper is different from the previous studies by taking into account the expense of battery energy storage under a newly defined term: cost of lifetime losses (CLLs). Thus the optimal scheduling and operation of BWGS not only gives maximum profit to the owner but also avoids the abusive operation of the battery. The case study provides a comparison of the proposed operation scheme with other approaches. It is shown that the proposed scheme considering the CLLs can significantly change the optimal charging/discharging of battery energy storage, and the increase in profit obtained in this case is about 9%. © 2014 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 6 February 2014
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 9 (2) , 129-135
Optimal scheduling and operation of battery/wind generation system in response to real‐time market prices
This paper addresses the scheduling and operation problem of a combined battery and wind generation system (BWGS) in real‐time market. The proposed operation scheme consists of two control mechanisms: (i) offline scheduling according to the estimation of the market prices and the stochastic information of wind generation, and (ii) online dispatching based on the updated system state in real time. The analysis in this paper is different from the previous studies by taking into account the expense of battery energy storage under a newly defined term: cost of lifetime losses (CLLs). Thus the optimal scheduling and operation of BWGS not only gives maximum profit to the owner but also avoids the abusive operation of the battery. The case study provides a comparison of the proposed operation scheme with other approaches. It is shown that the proposed scheme considering the CLLs can significantly change the optimal charging/discharging of battery energy storage, and the increase in profit obtained in this case is about 9%. © 2014 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 24 April 2013
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 23 (5) , 719-732
Three-wire network: a new distribution system approach considering both distributed generation and load requirements
This paper proposes a new approach to distribution system named Three-wire Network (3-NET). Considering the integration of different distributed generation (DG) technologies as well as the diversity of loads, the idea of 3-NET is splitting a single power network into three qualitatively different networks: (i) a high quality direct current (DC) network; (ii) a conventional alternating current (AC) network; and (iii) a low quality DC network. By this configuration, the multi-stage conversion of energy from DG sources can be reduced, whereas loads can be supplied with different power quality and reliability levels as desired. In order to evaluate the potential benefits of 3-NET, the operational strategy is formulated in a market model; the reliability performance is investigated using Monte Carlo simulation and quantified in terms of interruption costs. In the case study, the proposed 3-NET is considered for integrating a certain amount of DG into a specific distribution system and then compared with another system approach: hybrid AC–DC microgrid. The simulation shows that although the operation costs can be slightly higher, the 3-NET shows a great improvement in reliability performance in comparison with the hybrid microgrid. Copyright © 2013 John Wiley & Sons, Ltd.
- 24 April 2013
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 23 (5) , 719-732
Three-wire network: a new distribution system approach considering both distributed generation and load requirements
This paper proposes a new approach to distribution system named Three-wire Network (3-NET). Considering the integration of different distributed generation (DG) technologies as well as the diversity of loads, the idea of 3-NET is splitting a single power network into three qualitatively different networks: (i) a high quality direct current (DC) network; (ii) a conventional alternating current (AC) network; and (iii) a low quality DC network. By this configuration, the multi-stage conversion of energy from DG sources can be reduced, whereas loads can be supplied with different power quality and reliability levels as desired. In order to evaluate the potential benefits of 3-NET, the operational strategy is formulated in a market model; the reliability performance is investigated using Monte Carlo simulation and quantified in terms of interruption costs. In the case study, the proposed 3-NET is considered for integrating a certain amount of DG into a specific distribution system and then compared with another system approach: hybrid AC–DC microgrid. The simulation shows that although the operation costs can be slightly higher, the 3-NET shows a great improvement in reliability performance in comparison with the hybrid microgrid. Copyright © 2013 John Wiley & Sons, Ltd.
- 1 March 2013
- Published by The Korean Institute of Electrical Engineers in Journal of Electrical Engineering & Technology
- Vol. 8 (2) , 197-205
Novel Techniques for Real Time Computing Critical Clearing Time SIME-B and CCS-B
- 1 March 2013
- Published by The Korean Institute of Electrical Engineers in Journal of Electrical Engineering & Technology
- Vol. 8 (2) , 197-205
Novel Techniques for Real Time Computing Critical Clearing Time SIME-B and CCS-B
- Open Access
A New Battery Energy Storage Charging/Discharging Scheme for Wind Power Producers in Real-Time Markets
Under a deregulated environment, wind power producers are subject to many regulation costs due to the intermittence of natural resources and the accuracy limits of existing prediction tools. This paper addresses the operation (charging/discharging) problem of battery energy storage installed in a wind generation system in order to improve the value of wind power in the real-time market. Depending on the prediction of market prices and the probabilistic information of wind generation, wind power producers can schedule the battery energy storage for the next day in order to maximize the profit. In addition, by taking into account the expenses of using batteries, the proposed charging/discharging scheme is able to avoid the detrimental operation of battery energy storage which can lead to a significant reduction of battery lifetime, i.e., uneconomical operation. The problem is formulated in a dynamic programming framework and solved by a dynamic programming backward algorithm. The proposed scheme is then applied to the study cases, and the results of simulation show its effectiveness.
Open AccessA New Battery Energy Storage Charging/Discharging Scheme for Wind Power Producers in Real-Time Markets
Under a deregulated environment, wind power producers are subject to many regulation costs due to the intermittence of natural resources and the accuracy limits of existing prediction tools. This paper addresses the operation (charging/discharging) problem of battery energy storage installed in a wind generation system in order to improve the value of wind power in the real-time market. Depending on the prediction of market prices and the probabilistic information of wind generation, wind power producers can schedule the battery energy storage for the next day in order to maximize the profit. In addition, by taking into account the expenses of using batteries, the proposed charging/discharging scheme is able to avoid the detrimental operation of battery energy storage which can lead to a significant reduction of battery lifetime, i.e., uneconomical operation. The problem is formulated in a dynamic programming framework and solved by a dynamic programming backward algorithm. The proposed scheme is then applied to the study cases, and the results of simulation show its effectiveness.