Hao-Yu Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hao-Yu Shen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Gang Pan
Analysis and Testing Center, Ningbo Institute of Technology, Zhejiang University, Ningbo, Zhejiang, PR China. Fax: +86-574-88229520
3 shared publicationsHai‐Liang Jiang
Analysis and Testing Center, Ningbo Institute of Technology, Zhejiang University, Ningbo, Zhejiang, PR China. Fax: +86-574-88229520
2 shared publicationsHong‐Lei Mao
Analysis and Testing Center, Ningbo Institute of Technology, Zhejiang University, Ningbo, Zhejiang, PR China. Fax: +86-574-88229520
2 shared publicationsLi-Yan Ying
Analysis and Testing Center, Ningbo Institute of Technology, Zhejiang University, 1st Qianhu Nan Road, Ningbo, Zhejiang 315100, PR China
2 shared publicationsLu Zhou
Analysis and Testing Center, Ningbo Institute of Technology, Zhejiang University, Ningbo, Zhejiang, PR China. Fax: +86-574-88229520
2 shared publicationsQing-Hua Xia
Laboratory for Advanced Materials and New Catalysis, School of Chemistry and Materials Science, Hubei University, Wuhan 430062, PR China
2 shared publications
Latest Publications
- Open Access
- 30 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (10) , 1864
Simultaneous determination of seven phthalates and four parabens in cosmetic products using HPLC‐DAD and GC‐MS methods
- 30 May 2008
- Published by Wiley in Journal of Separation Science
- Vol. 31 (10) , 1864
Open AccessSimultaneous determination of seven phthalates and four parabens in cosmetic products using HPLC‐DAD and GC‐MS methods
- 17 October 2007
- Published by Elsevier in Journal of Molecular Catalysis A: Chemical
- Vol. 276 (1-2) , 73-79
Photocatalytic selective aerobic oxidation of alcohols to aldehydes and ketones by HPW/MCM-41 in ionic liquids
- 17 October 2007
- Published by Elsevier in Journal of Molecular Catalysis A: Chemical
- Vol. 276 (1-2) , 73-79
Photocatalytic selective aerobic oxidation of alcohols to aldehydes and ketones by HPW/MCM-41 in ionic liquids
- Open Access
- 6 June 2007
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 8 (6) , 505-512
Efficient Copper-bisisoquinoline-based Catalysts for Selective Aerobic Oxidation of Alcohols to Aldehydes and Ketones
The selective oxidation of alcohols with molecular oxygen was efficientlycompleted in high conversion and selectivity using copper-bisisoquinoline-based catalystsunder mild reaction condition. The effects of various parameters such as reactiontemperature, reaction time, oxidant, ligands, etc, were studied. Solvent effect has been aswell studied in ionic liquids [bmim]PF6, [omim]BF4 and [hmim]BF4, comparing totraditional volatile organic solvent. The use of ionic liquids was found to enhance thecatalytic properties of the catalysts used.
- 6 June 2007
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 8 (6) , 505-512
Open AccessEfficient Copper-bisisoquinoline-based Catalysts for Selective Aerobic Oxidation of Alcohols to Aldehydes and Ketones
The selective oxidation of alcohols with molecular oxygen was efficientlycompleted in high conversion and selectivity using copper-bisisoquinoline-based catalystsunder mild reaction condition. The effects of various parameters such as reactiontemperature, reaction time, oxidant, ligands, etc, were studied. Solvent effect has been aswell studied in ionic liquids [bmim]PF6, [omim]BF4 and [hmim]BF4, comparing totraditional volatile organic solvent. The use of ionic liquids was found to enhance thecatalytic properties of the catalysts used.
- 1 March 2007
- Vol. 25 (2) , 272-5
[Simultaneous determination of phthalates and parabens in cosmetic products by gas chromatography/mass spectrometry coupled with solid phase extraction].
Studies have been carried out on the simultaneous determination of 8 phthalates, i. e. di-ethyl phthalate (DEP) , di-propyl phthalate (DPP) , di-isobutyl phthalate (DIBP) , dibutyl phthalate (DBP) , benzyl butyl phthalate ( BBP) , di-cyclohexyl phthalate (DCHP) , di-(2-ethylhexyl) phthalate (DEHP), di-octyl phthalate (DOP) and 4 parabens, i. e. methylparaben (MPB), ethylparaben (EPB), propyl paraben (PPB), and butyl paraben (BPB) by gas chromatography in combination with mass spectrometry (GC/MS) in electron ionisation mode (EI) with selected-ion monitoring (SIM) acquisition method. The phthalates and parabens in 15 cosmetic products, including hair sprays, perfumes, deodorants, cream, lotion, etc. were determined. The determination of the samples were performed after sonication-assisted extraction with methanol, cleaned up with an LC-C18 column (3 mL) and analyzed by GC/MS method. The base peak (m/z 149) of the phthalates and the base peak (m/z 121) of the parabens were selected for the screening studies. The characteristic ions, m/z 121, 149, 177, 222 for DEP; m/z 149, 191, 209 for DPP; m/z 57, 149, 223 for DIBP; m/z 104, 149 for DBP; m/z 91, 132, 149, 206 for BBP; m/z 55, 149, 167 for DCHP; m/z 113, 149, 167, 279 for DEHP; m/z 149, 279 for DOP; m/z 65, 93, 121, 152 for MPB; m/z 93, 121, 138, 166 for EPB; m/z 93, 121, 138, 180 for PPB; and m/z 93, 121, 138, 194 for BPB were chosen for quantitative studies. These techniques are capable to detect phthalates and parabens at the level of 0. 1 -5. 0 microg/kg. Overall recoveries were 80% - 100% with relative standard deviations (RSDs) less than 10%. Only one of the 15 examined samples was free from phthalates and parabens. The rest 14 samples were found to contain at least 3 or more of these phthalates and/or parabens. The predominant phthalates detected in the studied samples were MPB, PPB, DPP, DCHP and DEHP. The residue levels were at 1. 42 -4 278 mg/kg.
- 1 March 2007
- Vol. 25 (2) , 272-5
[Simultaneous determination of phthalates and parabens in cosmetic products by gas chromatography/mass spectrometry coupled with solid phase extraction].
Studies have been carried out on the simultaneous determination of 8 phthalates, i. e. di-ethyl phthalate (DEP) , di-propyl phthalate (DPP) , di-isobutyl phthalate (DIBP) , dibutyl phthalate (DBP) , benzyl butyl phthalate ( BBP) , di-cyclohexyl phthalate (DCHP) , di-(2-ethylhexyl) phthalate (DEHP), di-octyl phthalate (DOP) and 4 parabens, i. e. methylparaben (MPB), ethylparaben (EPB), propyl paraben (PPB), and butyl paraben (BPB) by gas chromatography in combination with mass spectrometry (GC/MS) in electron ionisation mode (EI) with selected-ion monitoring (SIM) acquisition method. The phthalates and parabens in 15 cosmetic products, including hair sprays, perfumes, deodorants, cream, lotion, etc. were determined. The determination of the samples were performed after sonication-assisted extraction with methanol, cleaned up with an LC-C18 column (3 mL) and analyzed by GC/MS method. The base peak (m/z 149) of the phthalates and the base peak (m/z 121) of the parabens were selected for the screening studies. The characteristic ions, m/z 121, 149, 177, 222 for DEP; m/z 149, 191, 209 for DPP; m/z 57, 149, 223 for DIBP; m/z 104, 149 for DBP; m/z 91, 132, 149, 206 for BBP; m/z 55, 149, 167 for DCHP; m/z 113, 149, 167, 279 for DEHP; m/z 149, 279 for DOP; m/z 65, 93, 121, 152 for MPB; m/z 93, 121, 138, 166 for EPB; m/z 93, 121, 138, 180 for PPB; and m/z 93, 121, 138, 194 for BPB were chosen for quantitative studies. These techniques are capable to detect phthalates and parabens at the level of 0. 1 -5. 0 microg/kg. Overall recoveries were 80% - 100% with relative standard deviations (RSDs) less than 10%. Only one of the 15 examined samples was free from phthalates and parabens. The rest 14 samples were found to contain at least 3 or more of these phthalates and/or parabens. The predominant phthalates detected in the studied samples were MPB, PPB, DPP, DCHP and DEHP. The residue levels were at 1. 42 -4 278 mg/kg.
- 13 January 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (6) , 2227-2237
Preparation of Fe3O4-C18 nano-magnetic composite materials and their cleanup properties for organophosphorous pesticides
Magnetic Fe3O4-C18 composite nanoparticles of approximately 5–10 nm in size were synthesized and characterized by IR spectroscopy, atomic absorption spectroscopy, X-ray diffraction, and transmission electron microscopy. The magnetic Fe3O4-C18 composite nanoparticles were applied for cleanup and enrichment of organophosphorous pesticides. Comparative studies were carried out between magnetic Fe3O4-C18 composite nanoparticles and common C18 materials. Residues of organophosphorous pesticides were determined by gas chromatography in combination with a nitrogen/phosphorus detector. The cleanup and enrichment properties of magnetic Fe3O4-C18 composite nanoparticles are comparable with those of common C18 materials for enrichment of organophosphorous pesticides, but the cleanup and enrichment are faster and easier to perform. Presumed mechanism for the adhesion of the OPs to the Fe3O4-C18 magnetic nanoparticles
- 13 January 2007
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (6) , 2227-2237
Preparation of Fe3O4-C18 nano-magnetic composite materials and their cleanup properties for organophosphorous pesticides
Magnetic Fe3O4-C18 composite nanoparticles of approximately 5–10 nm in size were synthesized and characterized by IR spectroscopy, atomic absorption spectroscopy, X-ray diffraction, and transmission electron microscopy. The magnetic Fe3O4-C18 composite nanoparticles were applied for cleanup and enrichment of organophosphorous pesticides. Comparative studies were carried out between magnetic Fe3O4-C18 composite nanoparticles and common C18 materials. Residues of organophosphorous pesticides were determined by gas chromatography in combination with a nitrogen/phosphorus detector. The cleanup and enrichment properties of magnetic Fe3O4-C18 composite nanoparticles are comparable with those of common C18 materials for enrichment of organophosphorous pesticides, but the cleanup and enrichment are faster and easier to perform. Presumed mechanism for the adhesion of the OPs to the Fe3O4-C18 magnetic nanoparticles
- Open Access
- 5 January 2007
- Published by Wiley in Journal of Separation Science
- Vol. 30 (1) , 48-54
Simultaneous determination of seven phthalates and four parabens in cosmetic products using HPLC‐DAD and GC‐MS methods
Studies on the determination of seven kinds of phthalates, i. e. diethyl phthalate, dipropyl phthalate, dibutyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate, di‐(2‐ethylhexyl) phthalate, and dioctyl phthalate, and four parabens, i. e. methylparaben, ethylparaben, propylparaben, and butylparaben, in 15 kinds of cosmetic products, including hair sprays, perfumes, deodorants, cream, lotion, etc., by HPLC with diode array detection and GC‐MS in electron impact ionization mode with selected‐ion monitoring have been carried out. Methods have been developed for both qualitative and quantitative detection of phthalates and parabens. Extraction, clean‐up, and analysis procedures have been optimized. HPLC and GC‐MS determinations were performed after sonication‐assisted extraction with methanol and clean‐up with C18 SPE. These techniques permit detection of phthalates at a level of 10.0–100.0 μg/kg and of parabens at a level of 20.0–200.0 μg/kg. Overall recoveries were 85–108% with RSD values of 4.2–8.8%. Only one of the 15 examined samples was free from phthalates and parabens. The remaining 14 samples were found to contain at least three or more of these phthalates and/or parabens. The predominant phthalates and parabens detected in the studied samples were methylparaben, propylparaben, diethyl phthalate, dibutyl phthalate, dicyclohexyl phthalate, and di‐(2‐ethylhexyl) phthalate. The residue level is at 1.22–5289 mg/kg.
- 5 January 2007
- Published by Wiley in Journal of Separation Science
- Vol. 30 (1) , 48-54
Open AccessSimultaneous determination of seven phthalates and four parabens in cosmetic products using HPLC‐DAD and GC‐MS methods
Studies on the determination of seven kinds of phthalates, i. e. diethyl phthalate, dipropyl phthalate, dibutyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate, di‐(2‐ethylhexyl) phthalate, and dioctyl phthalate, and four parabens, i. e. methylparaben, ethylparaben, propylparaben, and butylparaben, in 15 kinds of cosmetic products, including hair sprays, perfumes, deodorants, cream, lotion, etc., by HPLC with diode array detection and GC‐MS in electron impact ionization mode with selected‐ion monitoring have been carried out. Methods have been developed for both qualitative and quantitative detection of phthalates and parabens. Extraction, clean‐up, and analysis procedures have been optimized. HPLC and GC‐MS determinations were performed after sonication‐assisted extraction with methanol and clean‐up with C18 SPE. These techniques permit detection of phthalates at a level of 10.0–100.0 μg/kg and of parabens at a level of 20.0–200.0 μg/kg. Overall recoveries were 85–108% with RSD values of 4.2–8.8%. Only one of the 15 examined samples was free from phthalates and parabens. The remaining 14 samples were found to contain at least three or more of these phthalates and/or parabens. The predominant phthalates and parabens detected in the studied samples were methylparaben, propylparaben, diethyl phthalate, dibutyl phthalate, dicyclohexyl phthalate, and di‐(2‐ethylhexyl) phthalate. The residue level is at 1.22–5289 mg/kg.
- 2 April 2004
- Published by Elsevier in Journal of Molecular Catalysis A: Chemical
- Vol. 212 (1-2) , 301-308
Comparative studies on alkylation of phenol with tert-butyl alcohol in the presence of liquid or solid acid catalysts in ionic liquids
- 2 April 2004
- Published by Elsevier in Journal of Molecular Catalysis A: Chemical
- Vol. 212 (1-2) , 301-308
Comparative studies on alkylation of phenol with tert-butyl alcohol in the presence of liquid or solid acid catalysts in ionic liquids