JIJenni Ikonen

Jenni Ikonen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jenni Ikonen has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Presence and Reduction of Anthropogenic Substances with UV Light and Oxidizing Disinfectants in Wastewater—A Case Study at Kuopio, Finland

    by Jenni Ikonen, Ilpo Nuutinen, Marjo Niittynen, Anna-Maria Hokajärvi, Tarja Pitkänen, Eero Antikainen, Ilkka T. Miettinen

    Anthropogenic substances are a major concern due to their potential harmful effects towards aquatic ecosystems. Because wastewater treatment plants (WWTPs) are not designed to remove these substances from wastewater, a part of the anthropogenic substances enter nature via WWTP discharges. During the spring 2019, the occurrence of anthropogenic substances in the municipal wastewater effluent in Kuopio, Finland, was analysed. Furthermore, the capacity of selected disinfection methods to reduce these substances from wastewater was tested. The disinfection methods were ozonation (760 mL min−1) with an OxTube hermetic dissolution method (1), the combined usage of peracetic acid (PAA) (−1) and ultraviolet (UV) disinfection (12 mJ/cm2) (2), and the combined usage of hydrogen peroxide (H2O2) (−1) and UV disinfection (12 mJ/cm2) (3). The substances found at the concentrations over 1 µg L−1 in effluent (N = 3) were cetirizine (5.2 ± 1.3 µg L−1), benzotriazole (BZT) (2.1 ± 0.98 µg L−1), hydrochlorothiazide (1.7 ± 0.2 µg L−1), furosemide (1.6 ± 0.2 µg L−1), lamotrigine (1.5 ± 0.06 µg L−1), diclofenac (DCF) (1.4 ± 0.2 µg L−1), venlafaxine (1.0 ± 0.13 µg L−1) and losartan (0.9 ± 0.2 µg L−1). The reduction (%) with different methods (1, 2, 3) were: cetirizine (99.9, 5.0, NR = no removal), benzotriazole (67.9, NR, NR), hydrochlorothiazide (91.1, 5.9, NR), furosemide (99.7, 5.9, NR), lamotrigine (46.4, NR, 6.7), diclofenac (99.7, 7.1, 16.7), venlafaxine (91.3, NR, 1.1), losartan (99.6, 13.8, NR). Further research concerning the tested disinfection methods is needed in order to fully elucidate their potential for removing anthropogenic substances from purified wastewater.


  • Open Access

    Active eukaryotes in drinking water distribution systems of ground and surface waterworks

    by Jenni Inkinen, Balamuralikrishna Jayaprakash, Sallamaari Siponen, Anna-Maria Hokajärvi, Anna Pursiainen, Jenni Ikonen, Ivan Ryzhikov, Martin Täubel, Ari Kauppinen, Jussi Paananen, et al.

    Eukaryotes are ubiquitous in natural environments such as soil and freshwater. Little is known of their presence in drinking water distribution systems (DWDSs) or of the environmental conditions that affect their activity and survival. Eukaryotes were characterized by Illumina high-throughput sequencing targeting 18S rRNA gene (DNA) that estimates the total community and the 18S rRNA gene transcript (RNA) that is more representative of the active part of the community. DWDS cold water (N = 124), hot water (N = 40), and biofilm (N = 16) samples were collected from four cities in Finland. The sampled DWDSs were from two waterworks A–B with non-disinfected, recharged groundwater as source water and from three waterworks utilizing chlorinated water (two DWDSs of surface waterworks C–D and one of ground waterworks E). In each DWDS, samples were collected from three locations during four seasons of 1 year. A beta-diversity analysis revealed that the main driver shaping the eukaryotic communities was the DWDS (A–E) (R = 0.73, P < 0.001, ANOSIM). The kingdoms Chloroplastida (green plants and algae), Metazoa (animals: rotifers, nematodes), Fungi (e.g., Cryptomycota), Alveolata (ciliates, dinoflagellates), and Stramenopiles (algae Ochrophyta) were well represented and active—judging based on the rRNA gene transcripts—depending on the surrounding conditions. The unchlorinated cold water of systems (A–B) contained a higher estimated total number of taxa (Chao1, average 380–480) than chlorinated cold water in systems C–E (Chao1 ≤ 210). Within each DWDS, unique eukaryotic communities were identified at different locations as was the case also for cold water, hot water, and biofilms. A season did not have a consistent impact on the eukaryotic community among DWDSs. This study comprehensively characterized the eukaryotic community members within the DWDS of well-maintained ground and surface waterworks providing good quality water. The study gives an indication that each DWDS houses a unique eukaryotic community, mainly dependent on the raw water source and water treatment processes in place at the corresponding waterworks. In particular, disinfection as well as hot water temperature seemed to represent a strong selection pressure that controlled the number of active eukaryotic species.


  • On-line detection of Escherichia coli intrusion in a pilot-scale drinking water distribution system

    by Jenni Ikonen, Tarja Pitkänen, Pascal Kosse, Robert Ciszek, Mikko Kolehmainen, Ilkka T. Miettinen


  • Open Access

    DRINKING WATER QUALITY IN DISTRIBUTION SYSTEMS OF SURFACE AND GROUND WATERWORKS IN FINLAND

    by Jenni Meirami Ikonena, Anna-Maria Hokajärvi, Jatta Heikkinen, Tarja Pitkänen, Robert Ciszek, Mikko Kolehmainen, Anna Pursiainen, Ari Kauppinen, Jaana Kusnetsov, Eila Torvinen, et al.

    Physico-chemical and microbiological water quality in the drinking water distribution systems (DWDSs) of five waterworks in Finland with different raw water sources and treatment processes was explored. Water quality was monitored during four seasons with on-line equipment and bulk water samples were analysed in laboratory. Seasonal changes in the water quality were more evident in DWDSs of surface waterworks compared to the ground waterworks and artificially recharging ground waterworks (AGR). Between seasons, temperature changed significantly in every sys-tem but pH and EC changed only in one AGR system. Seasonal change was seen also in the absorbance values of all sys-tems. The concentration of microbially available phosphorus (MAP, μg PO₄-P/l) was the highest in drinking water origi-nating from the waterworks supplying groundwater. Total assimilable organic carbon (AOC, μg AOC-C/l) concentrations were significantly different between the DWDSs other than between the two AGR systems. This study reports differences in the water quality between surface and ground waterworks using a wide set of parameters commonly used for monitor-ing. The results confirm that every distribution system is unique, and the water quality is affected by environmental fac-tors, raw water source, treatment methods and disinfection.


  • Open Access

    Suitability of Optical, Physical and Chemical Measurements for Detection of Changes in Bacterial Drinking Water Quality

    by Jenni Ikonen, Tarja Pitkänen, Ilkka T. Miettinen

    In this study, different optical, physical and chemical measurements were tested for their capacity to detect changes in water quality. The tests included UV-absorbance at 254 nm, absorbance at 420 nm, turbidity, particle counting, temperature, pH, electric conductivity (EC), free chlorine concentration and ATP concentration measurements. Special emphasis was given to investigating the potential for measurement tools to detect changes in bacterial concentrations in drinking water. Bacterial colony counts (CFU) and total bacterial cell counts (TBC) were used as reference methods for assessing the bacterial water quality. The study consists of a series of laboratory scale experiments: monitoring of regrowth of Pseudomonas fluorescens, estimation of the detection limits for optical measurements using Escherichia coli dilutions, verification of the relationships by analysing grab water samples from various distribution systems and utilisation of the measurements in the case of an accidentally contaminated distribution network. We found significant correlations between the tested measurements and the bacterial water quality. As the bacterial contamination of water often co-occurs with the intrusion of matrixes containing mainly non-bacterial components, the tested measurement tools can be considered to have the potential to rapidly detect any major changes in drinking water quality.