CCColin J. Campbell

Colin J. Campbell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Colin J. Campbell has a total of 208 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Adaptive Physics-Aware Raman Baseline Correction with Machine Learning Predicted Parameters

    by Prasad D. Aradhye, Souparna Mandal, Robert D. Gray, Colin J. Campbell

    Accurate baseline correction is critical for reliable Raman spectral interpretation. Traditional algorithmic methods often require manual tuning of regularization parameters, while recent machine learning and neural network approaches automate correction but lack generalizability and user control. We have developed a new approach to baseline correction which adaptively resolves baseline distortions without manual intervention - DIRAS (Dynamic Iterative Reweighted Autoregressive Spectral baseline correction). DIRAS uses a fixed regularization parameter (λ), which performs robust batch correction by iteratively reweighting residuals. We further used Structural Similarity Index Measure (SSIM) as an objective for λ optimization and trained a deep learning model to learn the nonlinear mapping between raw spectral features and optimal regularization. The resulting framework (DIRAS+) was capable of real-time spectrum-specific λ prediction. Applied to two SERS data sets, DIRAS+ outperformed ALS and SEALS in preserving peak fidelity, reducing intraclass variability and minimizing baseline distortion. Importantly, in downstream chemometric workflows, DIRAS improved calibration and model performance, yielding lower errors and enhancing analytical sensitivity. DIRAS and DIRAS+ together provide robust, scalable, and user-adaptable solutions for high-throughput Raman spectroscopy applications.


  • Open Access

    Label-Free SERS Sensors for Real-Time Monitoring of Tyrosine Phosphorylation

    by Ailsa Geddis, Lorena Mendive-Tapia, Audreylia Sujantho, Erica Liu, Sarah McAughtrie, Richard Goodwin, Marc Vendrell, Colin J. Campbell

    Dysregulation of receptor tyrosine kinases (RTKs) has been shown to correlate with cancer cell proliferation and drug resistance. Thus, monitoring the activity of RTKs at a chemical level could provide new biomedical insights and methods to assess the drug efficacy. However, direct monitoring of kinase activity is challenging and most commonly relies on in vitro techniques such as Western blotting and ELISAs. Herein, we report the development of a gold nanoparticle-based surface-enhanced Raman scattering (SERS) sensor, which allows the real-time monitoring of tyrosine phosphorylation of a reporter peptide (Axltide) by the Axl enzyme. We demonstrate that our sensor shows strong signal localization, and we are able to detect tyrosine phosphorylation of the reporter peptide through chemical phosphorylation and enzymatically with similar peak changes to those observed in the spontaneous Raman spectra. Through monitoring the SERS spectrum, we can observe changes in phosphorylation in real time.


  • Open Access

    SERS Microsensors for the Study of pH Regulation in Cystic Fibrosis Patient-Derived Airway Cultures

    by William H. Skinner, Nicola Robinson, Gareth R. Hardisty, Robert D. Gray, Colin J. Campbell

    Acidification of the airway surface liquid in the respiratory system could play a role in the pathology of Cystic Fibrosis, but its low volume and proximity to the airway epithelium make it a challenging biological environment in which to noninvasively collect pH measurements. To address this challenge, we explored surface enhanced Raman scattering microsensors (SERS-MS), with a 4-mercaptobenzoic acid (MBA) pH reporter molecule, as pH sensors for the airway surface liquid of patient-derived in vitro models of the human airway. Using air-liquid interface (ALI) cultures to model the respiratory epithelium, we show that SERS-MS facilitates the optical measurement of trans-epithelial pH gradients between the airway surface liquid and the basolateral culture medium. SERS-MS also enabled the successful quantification of pH changes in the airway surface liquid following stimulation of the Cystic Fibrosis transmembrane conductance regulator (CFTR, the apical ion channel that is dysfunctional in Cystic Fibrosis airways). Finally, the influence of CFTR mutations on baseline airway surface liquid pH was explored by using SERS-MS to measure the pH in ALIs grown from Cystic Fibrosis and non-Cystic Fibrosis donors.


  • Open Access

    SERS microsensors for pH measurements in the lumen and ECM of stem cell derived human airway organoids

    by William Hamish Skinner, Nicola Robinson, Gareth R. Hardisty, Holly Fleming, Ailsa Geddis, Mark Bradley, Robert D. Gray, Colin J. Campbell

    SERS microsensors (SERS-MS) are polymer microparticles coated in gold nanoparticles and functionalised with mercaptobenzoic acid. SERS-MS were incorporated into human airway organoids to measured pH optically.


  • Time-correlated Raman and fluorescence lifetime spectroscopy at megahertz repetition rates

    by Heather McEwan, Gillian E. Brown, Andrea Usai, Ahmet Erdogan, Alistair Gorman, Colin J. Campbell, Robert K. Henderson, Neil Finlayson

    SPIE Digital Library Proceedings


  • Automatic Cocrystal Detection by Raman Spectral Deconvolution-Based Novelty Analysis

    by Mehrdad Yaghoobi, Tudor Grecu, Stephanie Brookes, Colin J. Campbell

    Cocrystals are important molecular adducts that have many advantages as a means of modifying the physicochemical properties of active pharmaceutical ingredients, including taste masking and improved solubility, bioavailability, and stability. As a result, the discovery of new cocrystals is of great interest to commercial drug discovery programs. Time-consuming manual analysis of the large volumes of data that emerge from large-scale cocrystal screening programs of up to 1000s of preparations poses a challenge. Raman spectroscopy has been shown to discriminate between cocrystals and physical mixtures and is easy to automate, allowing rapid screening of large numbers of potential cocrystals, but the spectral features that encode the information are often subtle (e.g., slight changes in peak positions or intensities). We have employed an automated signal processing routine based on a sparse decomposition algorithm to speed up the data processing steps while maintaining the accuracy of a trained spectroscopist. We used our algorithm to screen 31 potential cocrystal preparations and found that through the use of a computationally generated threshold, we could achieve a clear classification of cocrystals and physical mixtures in less than a minute, compared to several hours manually.


  • Fabrication of a Wearable Flexible Sweat pH Sensor Based on SERS-Active Au/TPU Electrospun Nanofibers

    by Michael Chung, William H. Skinner, Colin Robert, Colin J. Campbell, René M. Rossi, Vasileios Koutsos, Norbert Radacsi

    Development of wearable sensing platforms is essential for the advancement of continuous health monitoring and point-of-care testing. Eccrine sweat pH is an analyte that can be noninvasively measured and used to diagnose and aid in monitoring a wide range of physiological conditions. Surface-enhanced Raman scattering (SERS) offers a rapid, optical technique for fingerprinting of biomarkers present in sweat. In this paper, a mechanically flexible, nanofibrous, SERS-active substrate was fabricated by a combination of electrospinning of thermoplastic polyurethane (TPU) and Au sputter coating. This substrate was then investigated for suitability toward wearable sweat pH sensing after functionalization with two commonly used pH-responsive molecules, 4-mercaptobenzoic acid (4-MBA), and 4-mercaptopyridine (4-MPy). The developed SERS pH sensor was found to have good resolution (0.14 pH units for 4-MBA; 0.51 pH units for 4-MPy), with only 1 μL of sweat required for a measurement, and displayed no statistically significant difference in performance after 35 days (p = 0.361). Additionally, the Au/TPU nanofibrous SERS pH sensors showed fast sweat-absorbing ability as well as good repeatability and reversibility. The proposed methodology offers a facile route for the fabrication of SERS substrates which could also be used to measure a wide range of health biomarkers beyond sweat pH.


  • A SERS-Active Electrospun Polymer Mesh for Spatially Localized pH Measurements of the Cellular Microenvironment

    by William H. Skinner, Michael Chung, Stephen Mitchell, Asli Akidil, Kristin Fabre, Richard Goodwin, Adam A. Stokes, Norbert Radacsi, Colin J. Campbell

    Extracellular pH (pHe) is an important chemical factor in many cellular processes and disease pathologies. The routine sampling of pHe in vitro could lead to innovative advances in therapeutics. To this end, we have fabricated a novel gold-coated polymer mesh, which facilitates the real-time measurement of pHe via surface-enhanced Raman scattering (SERS). In this proof of concept study, we apply our SERS sensor to measure metabolically induced changes in the pHe of carcinoma-derived cell line HepG2/C3A. We demonstrate that gold-coated polyurethane electrospun nanofibers (AuNF) have strong and reproducible SERS spectra of surface-adsorbed analytes. By functionalizing AuNF with pH-responsive reporter 4-mercaptobenzoic acid (MBA), we have developed an accurate pH SERS sensor for the extracellular microenvironment. We cultured HepG2/C3A on the surface of MBA-AuNF and measured an acidic shift in pHe at the cell–fiber interface. Following exposure to staurosporine, an apoptosis-inducing drug, we observed changes in the HepG2/C3A cellular morphology indicative of controlled cell death, and detected an increase in the pHe of HepG2/C3A. These results demonstrate how subtle changes in pHe, induced by the metabolic activity of cells, can be measured with our novel SERS sensor MBA-AuNF. The excellent pH measurement performance of MBA-AuNF provides a unique platform to study extracellular pH on the microscale and will help to deepen our understanding of pHe in disease pathology.


  • Open Access

    Noninvasive Detection of Ischemic Vascular Damage in a Pig Model of Liver Donation After Circulatory Death

    by Katherine J.I. Ember, Fiona Hunt, Lauren E. Jamieson, John M. Hallett, Hannah Esser, Timothy J. Kendall, R. Eddie Clutton, Rachael Gregson, Karen Faulds, Stuart J. Forbes, et al.

    Background and Aims: Liver graft quality is evaluated by visual inspection prior to transplantation, a process highly dependent on the surgeon’s experience. We present an objective, noninvasive, quantitative way of assessing liver quality in real time using Raman spectroscopy, a laser‐based tool for analyzing biomolecular composition. Approach and Results: A porcine model of donation after circulatory death (DCD) with normothermic regional perfusion (NRP) allowed assessment of liver quality premortem, during warm ischemia (WI) and post‐NRP. Ten percent of circulating blood volume was removed in half of experiments to simulate blood recovery for DCD heart removal. Left median lobe biopsies were obtained before circulatory arrest, after 45 minutes of WI, and after 2 hours of NRP and analyzed using spontaneous Raman spectroscopy, stimulated Raman spectroscopy (SRS), and staining. Measurements were also taken in situ from the porcine liver using a handheld Raman spectrometer at these time points from left median and right lateral lobes. Raman microspectroscopy detected congestion during WI by measurement of the intrinsic Raman signal of hemoglobin in red blood cells (RBCs), eliminating the need for exogenous labels. Critically, this microvascular damage was not observed during WI when 10% of circulating blood was removed before cardiac arrest. Two hours of NRP effectively cleared RBCs from congested livers. Intact RBCs were visualized rapidly at high resolution using SRS. Optical properties of ischemic livers were significantly different from preischemic and post‐NRP livers as measured using a handheld Raman spectrometer. Conclusions: Raman spectroscopy is an effective tool for detecting microvascular damage which could assist the decision to use marginal livers for transplantation. Reducing the volume of circulating blood before circulatory arrest in DCD may help reduce microvascular damage.


  • Open Access

    Intracellular redox potential is correlated with miRNA expression in MCF7 cells under hypoxic conditions

    by Hannah Johnston, Paul Dickinson, Alasdair Ivens, Amy H. Buck, R. D. Levine, Francoise Remacle, Colin J. Campbell

    Significance: Cancer is associated with low-oxygen cellular environments. However, a better understanding of the connection between the amount of oxygen in a cell’s microenvironment and its behavior is much needed. By optical measurements, we have characterized how the redox chemistry and the intracellular redox potential of cells respond to changes in oxygen pressure. Through surprisal analysis (a technique based on thermodynamics), we were able to identify changes in cellular signaling molecules (microRNAs [miRNAs]) that correlate with redox changes and found that, at low-oxygen conditions, these miRNAs are associated with tumor spread and survival. The changes in miRNA expression were used to quantify the free-energy variations with oxygen pressure, variations that reflect the changes in the measured intracellular redox potential.