Thorsten Schlomm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Thorsten Schlomm has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Haese
Martini-Clinic, Prostate Cancer Center, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications - Markus Graefen
Martini-Clinic, Prostate Cancer Center, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications - Pierre Tennstedt
Martini-Klinik Prostate Cancer Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
2 shared publications - Thomas Steuber
Martini Clinic, Prostate Cancer Center Hamburg-Eppendorf, Hamburg, Germany
2 shared publications Andreas Brüchmann
1 shared publication- Andreas Erbersdobler
Institut für Pathologie, Universitätsmedizin Rostock, Rostock, Deutschland
1 shared publication
Latest Publications
- 1 February 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (4) , 147
A feasible and time-efficient adaption of the neurosafe intraoperative frozen section technique to robotic-assisted radical prostatectomy.
147 Background: In robotic-assisted radical prostatectomy (RARP) intraoperative frozen sections are often avoided due to suspected difficulties in harvesting the prostate during this procedure, loss in pneumoperitoneum, increased blood loss and lacking impact on functional outcome. We demonstrate the technique, feasibility and beneficial impact of our NeuroSAFE technique on the rate of nerve-sparing (NS) in RARP and analyse the oncological outcome. Methods: We analyzed 1,570 consecutive patients undergoing RARP from 2004 to 2012. NeuroSAFE was done in 1,178 pts. We compared OR-time, blood loss, frequency of nerve-sparing (NS) and PSM in non-NeuroSAFE versus NeuroSAFE-RARP. The prostate was intraoperatively harvested via an extension of the camera trocar incision without undocking the system. Instrument arms were not undocked. Blood spillage from the dorsal vein complex due to loss of pneumoperitoneum was avoided by upward traction on the transurethral catheter. After prostate removal, pneumoperitoneum was reestablished by closing the extended incision and repositioning of the optical trocar. NeuroSAFE-procedure consisted of intraoperative bilateral frozen sections covering the entire contact area of the prostate and the neurovascular bundles. Results: There was no significant difference in blood loss (253.5±204.4 ml vs. 265.8±246.7 ml, p=0.49) and OR-time. (220 min ± 51 vs. 224 min ± 64, p=0.22). No complications associated with specimen harvesting occurred. NS-rate increased significantly with vs. without NeuroSAFE (overall 97% vs. 81%, pT2 99% vs. 90%, pT3a 94% vs. 74%, pT3b 91% vs. 30). PSM rate dropped significantly with NeuroSAFE (overall 16% vs. 24%, pT2 8% vs. 15%, pT3a 22% vs. 39%, pT3b 49% vs. 67%, all p
- 1 February 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (4) , 147
A feasible and time-efficient adaption of the neurosafe intraoperative frozen section technique to robotic-assisted radical prostatectomy.
147 Background: In robotic-assisted radical prostatectomy (RARP) intraoperative frozen sections are often avoided due to suspected difficulties in harvesting the prostate during this procedure, loss in pneumoperitoneum, increased blood loss and lacking impact on functional outcome. We demonstrate the technique, feasibility and beneficial impact of our NeuroSAFE technique on the rate of nerve-sparing (NS) in RARP and analyse the oncological outcome. Methods: We analyzed 1,570 consecutive patients undergoing RARP from 2004 to 2012. NeuroSAFE was done in 1,178 pts. We compared OR-time, blood loss, frequency of nerve-sparing (NS) and PSM in non-NeuroSAFE versus NeuroSAFE-RARP. The prostate was intraoperatively harvested via an extension of the camera trocar incision without undocking the system. Instrument arms were not undocked. Blood spillage from the dorsal vein complex due to loss of pneumoperitoneum was avoided by upward traction on the transurethral catheter. After prostate removal, pneumoperitoneum was reestablished by closing the extended incision and repositioning of the optical trocar. NeuroSAFE-procedure consisted of intraoperative bilateral frozen sections covering the entire contact area of the prostate and the neurovascular bundles. Results: There was no significant difference in blood loss (253.5±204.4 ml vs. 265.8±246.7 ml, p=0.49) and OR-time. (220 min ± 51 vs. 224 min ± 64, p=0.22). No complications associated with specimen harvesting occurred. NS-rate increased significantly with vs. without NeuroSAFE (overall 97% vs. 81%, pT2 99% vs. 90%, pT3a 94% vs. 74%, pT3b 91% vs. 30). PSM rate dropped significantly with NeuroSAFE (overall 16% vs. 24%, pT2 8% vs. 15%, pT3a 22% vs. 39%, pT3b 49% vs. 67%, all p
- Open Access
- 4 March 2013
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 14 (3) , 5239-5249
A Cancer-Indicative microRNA Pattern in Normal Prostate Tissue
We analyzed the levels of selected micro-RNAs in normal prostate tissue to assess their potential to indicate tumor foci elsewhere in the prostate. Histologically normal prostate tissue samples from 31 prostate cancer patients and two cancer negative control groups with either unsuspicious or elevated prostate specific antigen (PSA) levels (14 and 17 individuals, respectively) were analyzed. Based on the expression analysis of 157 microRNAs in a pool of prostate tissue samples and information from data bases/literature, we selected eight microRNAs for quantification by real-time polymerase chain reactions (RT-PCRs). Selected miRNAs were analyzed in histologically tumor-free biopsy samples from patients and healthy controls. We identified seven microRNAs (miR-124a, miR-146a & b, miR-185, miR-16 and let-7a & b), which displayed significant differential expression in normal prostate tissue from men with prostate cancer compared to both cancer negative control groups. Four microRNAs (miR-185, miR-16 and let-7a and let-7b) remained to significantly discriminate normal tissues from prostate cancer patients from those of the cancer negative control group with elevated PSA levels. The transcript levels of these microRNAs were highly indicative for the presence of cancer in the prostates, independently of the PSA level. Our results suggest a microRNA-pattern in histologically normal prostate tissue, indicating prostate cancer elsewhere in the organ.
- 4 March 2013
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 14 (3) , 5239-5249
Open AccessA Cancer-Indicative microRNA Pattern in Normal Prostate Tissue
We analyzed the levels of selected micro-RNAs in normal prostate tissue to assess their potential to indicate tumor foci elsewhere in the prostate. Histologically normal prostate tissue samples from 31 prostate cancer patients and two cancer negative control groups with either unsuspicious or elevated prostate specific antigen (PSA) levels (14 and 17 individuals, respectively) were analyzed. Based on the expression analysis of 157 microRNAs in a pool of prostate tissue samples and information from data bases/literature, we selected eight microRNAs for quantification by real-time polymerase chain reactions (RT-PCRs). Selected miRNAs were analyzed in histologically tumor-free biopsy samples from patients and healthy controls. We identified seven microRNAs (miR-124a, miR-146a & b, miR-185, miR-16 and let-7a & b), which displayed significant differential expression in normal prostate tissue from men with prostate cancer compared to both cancer negative control groups. Four microRNAs (miR-185, miR-16 and let-7a and let-7b) remained to significantly discriminate normal tissues from prostate cancer patients from those of the cancer negative control group with elevated PSA levels. The transcript levels of these microRNAs were highly indicative for the presence of cancer in the prostates, independently of the PSA level. Our results suggest a microRNA-pattern in histologically normal prostate tissue, indicating prostate cancer elsewhere in the organ.
- Open Access
- 28 September 2011
- Published by Spandidos Publications in International Journal of Oncology
- Vol. 40 (1) , 261-268
The impact of the number of cores on tissue microarray studies investigating prostate cancer biomarkers
Most tissue microarray studies have used a single 0.6-mm tissue core per donor tissue. It has been suggested that multiple cores per donor can increase the representativity of tissue microarray studies. To estimate the potential benefit of multiple cores, we analyzed Ki67 and p53 in triplet cores taken from three different areas of 3,261 prostate cancer tissue blocks. Both p53 and Ki67 labeling index were linked to advanced tumor stage (p<0.0001 each), Gleason score (p<0.0001), and early PSA recurrence (p<0.0001) independently of whether the 3 tissue spots were analyzed separately or combined for a consensus result. The rate of positive findings increased with the amount of analyzed tissue. The average Ki67 labeling index was higher in tumors with 3 interpretable spots (5.3±5.6) as compared to two (4.1±4.7) or one interpretable spot (4.1±4.2, p<0.0001). For p53, tumors with three interpretable spots were positive in 3.8% of cases, and tumors with 1 or 2 interpretable spots in 1.9% only (p=0.003). These data demonstrate that using multiple cores in a tissue microarray does not necessarily increase the ability to identify associations of biomarkers with tumor phenotype and prognosis but has always the disadvantage of additional work and tissue requirements. Multiple cores may even lead to statistical problems if unequal amounts of tissue are analyzed per tumor.
- 28 September 2011
- Published by Spandidos Publications in International Journal of Oncology
- Vol. 40 (1) , 261-268
Open AccessThe impact of the number of cores on tissue microarray studies investigating prostate cancer biomarkers
Most tissue microarray studies have used a single 0.6-mm tissue core per donor tissue. It has been suggested that multiple cores per donor can increase the representativity of tissue microarray studies. To estimate the potential benefit of multiple cores, we analyzed Ki67 and p53 in triplet cores taken from three different areas of 3,261 prostate cancer tissue blocks. Both p53 and Ki67 labeling index were linked to advanced tumor stage (p<0.0001 each), Gleason score (p<0.0001), and early PSA recurrence (p<0.0001) independently of whether the 3 tissue spots were analyzed separately or combined for a consensus result. The rate of positive findings increased with the amount of analyzed tissue. The average Ki67 labeling index was higher in tumors with 3 interpretable spots (5.3±5.6) as compared to two (4.1±4.7) or one interpretable spot (4.1±4.2, p<0.0001). For p53, tumors with three interpretable spots were positive in 3.8% of cases, and tumors with 1 or 2 interpretable spots in 1.9% only (p=0.003). These data demonstrate that using multiple cores in a tissue microarray does not necessarily increase the ability to identify associations of biomarkers with tumor phenotype and prognosis but has always the disadvantage of additional work and tissue requirements. Multiple cores may even lead to statistical problems if unequal amounts of tissue are analyzed per tumor.