Christian Peth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Christian Peth has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Anton Kalinin
Laser-Laboratorium Göttingen e.V. , Hans-Adolf-Krebs-Weg 1, D-37077 Göttingen, Germany
1 shared publicationFrank Barkusky
Laser-Laboratorium Göttingen e.V. , Hans-Adolf-Krebs-Weg 1, D-37077 Göttingen, Germany
1 shared publication- Gerhard Busse
Max Planck Institute for Biophysical Chemistry, Am Fassberg 11, 37077 Göttingen, Germany
1 shared publication J. Peter Toennies
Max-Planck-Institute for Dynamics and Self-Organization , Bunsenstraße 10, D-37073 Göttingen, Germany
1 shared publicationKlaus Mann
Laser-Laboratorium Göttingen e.V. , Hans-Adolf-Krebs-Weg 1, D-37077 Göttingen, Germany
1 shared publication- Klaus Mann
Laser-Lab. Goettingen eV (Germany)
1 shared publication
Latest Publications
- Open Access
- 4 November 2009
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 10 (11) , 4754-4771
Time-Resolved Soft X-ray Diffraction Reveals Transient Structural Distortions of Ternary Liquid Crystals
Home-based soft X-ray time-resolved scattering experiments with nanosecond time resolution (10 ns) and nanometer spatial resolution were carried out at a table top soft X-ray plasma source (2.2–5.2 nm). The investigated system was the lyotropic liquid crystal C16E7/paraffin/glycerol/formamide/IR 5. Usually, major changes in physical, chemical, and/or optical properties of the sample occur as a result of structural changes and shrinking morphology. Here, these effects occur as a consequence of the energy absorption in the sample upon optical laser excitation in the IR regime. The liquid crystal shows changes in the structural response within few hundred nanoseconds showing a time decay of 182 ns. A decrease of the Bragg peak diffracted intensity of 30% and a coherent macroscopic movement of the Bragg reflection are found as a response to the optical pump. The Bragg reflection movement is established to be isotropic and diffusion controlled (1 μs). Structural processes are analyzed in the Patterson analysis framework of the time-varying diffraction peaks revealing that the inter-lamellar distance increases by 2.7 Å resulting in an elongation of the coherently expanding lamella crystallite. The present studies emphasize the possibility of applying TR-SXRD techniques for studying the mechanical dynamics of nanosystems.
- 4 November 2009
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 10 (11) , 4754-4771
Open AccessTime-Resolved Soft X-ray Diffraction Reveals Transient Structural Distortions of Ternary Liquid Crystals
Home-based soft X-ray time-resolved scattering experiments with nanosecond time resolution (10 ns) and nanometer spatial resolution were carried out at a table top soft X-ray plasma source (2.2–5.2 nm). The investigated system was the lyotropic liquid crystal C16E7/paraffin/glycerol/formamide/IR 5. Usually, major changes in physical, chemical, and/or optical properties of the sample occur as a result of structural changes and shrinking morphology. Here, these effects occur as a consequence of the energy absorption in the sample upon optical laser excitation in the IR regime. The liquid crystal shows changes in the structural response within few hundred nanoseconds showing a time decay of 182 ns. A decrease of the Bragg peak diffracted intensity of 30% and a coherent macroscopic movement of the Bragg reflection are found as a response to the optical pump. The Bragg reflection movement is established to be isotropic and diffusion controlled (1 μs). Structural processes are analyzed in the Patterson analysis framework of the time-varying diffraction peaks revealing that the inter-lamellar distance increases by 2.7 Å resulting in an elongation of the coherently expanding lamella crystallite. The present studies emphasize the possibility of applying TR-SXRD techniques for studying the mechanical dynamics of nanosystems.
- 1 October 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (10) , 103509
XUV laser-plasma source based on solid Ar filament
We present a laser driven soft x-ray source based on a novel solid argon filament. The continuously flowing micron-sized filament (diameter ∼56μm, flow speed ∼5mm∕s) was used as a laser target in order to generate a plasma source of high brightness in the “water window” (2.2–4.4nm) spectral range. The emission properties of the source were characterized in detail with respect to crucial parameters such as positional and energy stability using an extreme ultraviolet (XUV) sensitive pinhole camera and an XUV spectrometer. The results are compared with an argon plasma based on a gas puff target operated under the same experimental conditions showing an increase of the brilliance by a factor of 84. By changing the capillary geometry from a constant diameter to a convergent shape the flow speed of the filament was significantly increased up to 250mm∕s, facilitating the operation at higher repetition rates.
- 1 October 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (10) , 103509
XUV laser-plasma source based on solid Ar filament
We present a laser driven soft x-ray source based on a novel solid argon filament. The continuously flowing micron-sized filament (diameter ∼56μm, flow speed ∼5mm∕s) was used as a laser target in order to generate a plasma source of high brightness in the “water window” (2.2–4.4nm) spectral range. The emission properties of the source were characterized in detail with respect to crucial parameters such as positional and energy stability using an extreme ultraviolet (XUV) sensitive pinhole camera and an XUV spectrometer. The results are compared with an argon plasma based on a gas puff target operated under the same experimental conditions showing an increase of the brilliance by a factor of 84. By changing the capillary geometry from a constant diameter to a convergent shape the flow speed of the filament was significantly increased up to 250mm∕s, facilitating the operation at higher repetition rates.