Heike Hall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Heike Hall has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jeffrey A. Hubbell
Departments of Chemical and Biomolecular Engineering and of Biomedical Engineering, New York University, New York, NY, USA, 11021
5 shared publications Anne Greet Bittermann
ZMB, Center for Microscopy and Image Analysis University of Zurich, Switzerland
2 shared publications- Anne Greet Bittermann
ZMB, Center for Microscopy and Imaging Analysis, University of Zurich, Switzerland
1 shared publication Claus Burkhardt
NMI Natural and Medical Sciences Institute, Reutlingen, Germany, Department of Materials, Cells and Biomaterials, ETH Zurich, Switzerland
1 shared publicationDamir Bozic
1 shared publication- Daniel Eberli
Department of Urology, University Hospital of Zürich, Zürich, Switzerland
1 shared publication
Latest Publications
- 31 October 2010
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 21 (5) , 583-585
Tissue, cell and pathway engineering
- 31 October 2010
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 21 (5) , 583-585
Tissue, cell and pathway engineering
- 30 September 2010
- Published by Springer Nature
- p. 1-26
Modified 3D-Fibrin Matrices in Tissue Engineering for Stimulation of Angiogenesis and Wound Healing
- 30 September 2010
- Published by Springer Nature
- p. 1-26
Modified 3D-Fibrin Matrices in Tissue Engineering for Stimulation of Angiogenesis and Wound Healing
- Open Access
Scaffold Characteristics for Functional Hollow Organ Regeneration
Many medical conditions require surgical reconstruction of hollow organs. Tissue engineering of organs and tissues is a promising new technique without harvest site morbidity. An ideal biomaterial should be biocompatible, support tissue formation and provide adequate structural support. It should degrade gradually and provide an environment allowing for cell-cell interaction, adhesion, proliferation, migration, and differentiation. Although tissue formation is feasible, functionality has never been demonstrated. Mainly the lack of proper innervation and vascularisation are hindering contractility and normal function. In this chapter we critically review the current state of engineering hollow organs with a special focus on innervation and vascularisation.
Open AccessScaffold Characteristics for Functional Hollow Organ Regeneration
Many medical conditions require surgical reconstruction of hollow organs. Tissue engineering of organs and tissues is a promising new technique without harvest site morbidity. An ideal biomaterial should be biocompatible, support tissue formation and provide adequate structural support. It should degrade gradually and provide an environment allowing for cell-cell interaction, adhesion, proliferation, migration, and differentiation. Although tissue formation is feasible, functionality has never been demonstrated. Mainly the lack of proper innervation and vascularisation are hindering contractility and normal function. In this chapter we critically review the current state of engineering hollow organs with a special focus on innervation and vascularisation.
- 18 November 2009
- Published by Wiley in Advanced Engineering Materials
- Vol. 11 (11) , B182-B188
Imaging of Cell‐to‐Material Interfaces by SEM after in situ Focused Ion Beam Milling on Flat Surfaces and Complex 3D‐Fibrous Structures
- 18 November 2009
- Published by Wiley in Advanced Engineering Materials
- Vol. 11 (11) , B182-B188
Imaging of Cell‐to‐Material Interfaces by SEM after in situ Focused Ion Beam Milling on Flat Surfaces and Complex 3D‐Fibrous Structures
- Open Access
Cell Guidance by 3D-Gradients in Hydrogel Matrices: Importance for Biomedical Applications
Concentration gradients of soluble and matrix-bound guidance cues in the extracellular matrix direct cell growth in native tissues and are of great interest for design of biomedical scaffolds and on implant surfaces. The focus of this review is to demonstrate the importance of gradient guidance for cells as it would be desirable to direct cell growth onto/into biomedical devices. Many studies have been described that illustrate the production and characterization of surface gradients, but three dimensional (3D)-gradients that direct cellular behavior are not well investigated. Hydrogels are considered as synthetic replacements for native extracellular matrices as they share key functions such as 2D- or 3D-solid support, fibrous structure, gas- and nutrition permeability and allow storage and release of biologically active molecules. Therefore this review focuses on current studies that try to implement soluble or covalently-attached gradients of growth factors, cytokines or adhesion sequences into 3D-hydrogel matrices in order to control cell growth, orientation and migration towards a target. Such gradient architectures are especially desirable for wound healing purposes, where defined cell populations need to be recruited from the blood stream and out of the adjacent tissue, in critical bone defects, for vascular implants or neuronal guidance structures where defined cell populations should be guided by appropriate signals to reach their proper positions or target tissues in order to accomplish functional repair.
Open AccessCell Guidance by 3D-Gradients in Hydrogel Matrices: Importance for Biomedical Applications
Concentration gradients of soluble and matrix-bound guidance cues in the extracellular matrix direct cell growth in native tissues and are of great interest for design of biomedical scaffolds and on implant surfaces. The focus of this review is to demonstrate the importance of gradient guidance for cells as it would be desirable to direct cell growth onto/into biomedical devices. Many studies have been described that illustrate the production and characterization of surface gradients, but three dimensional (3D)-gradients that direct cellular behavior are not well investigated. Hydrogels are considered as synthetic replacements for native extracellular matrices as they share key functions such as 2D- or 3D-solid support, fibrous structure, gas- and nutrition permeability and allow storage and release of biologically active molecules. Therefore this review focuses on current studies that try to implement soluble or covalently-attached gradients of growth factors, cytokines or adhesion sequences into 3D-hydrogel matrices in order to control cell growth, orientation and migration towards a target. Such gradient architectures are especially desirable for wound healing purposes, where defined cell populations need to be recruited from the blood stream and out of the adjacent tissue, in critical bone defects, for vascular implants or neuronal guidance structures where defined cell populations should be guided by appropriate signals to reach their proper positions or target tissues in order to accomplish functional repair.
- 9 April 2009
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 91B (1) , 109-121
Cyto‐ and hemocompatibility of a biodegradable 3D‐scaffold material designed for medical applications
In this study, the polyester urethane Degrapol® (DP) was explored for medical applications. Electrospun DP‐fiber fleeces were characterized with regard to fiber morphology, swelling, and interconnectivity of interfiber spaces. Moreover, DP was assayed for cell proliferation and hemocompatibility being a prerequisite to any further in vivo application. It was shown that DP‐fiber fleeces produced at different humidity while spinning affects interconnectivity of interfiber spaces, such that the higher the humidity the looser the resulting fiber fleeces. When the spinning target was cooled with dry ice, the resulting DP‐fibers remained less fused to each other. However, permeability for fluorescent beads was not significantly increased. Fibroblast adhesion and proliferation occurred in a comparable manner on native as well as on fibronectin or collagen I adsorbed DP‐fiber fleeces. On DP‐surfaces fibroblasts proliferated equally well as compared with glass or PLGA surfaces or DP‐surfaces adsorbed with fibronectin or collagen I. In contrast, human umbilical vein endothelial cells proliferated only after adsorption of DP‐surfaces with fibronectin or collagen I, indicating that different cell types respond differently to DP‐surfaces. Furthermore, hemocompatibility of DP‐surfaces was found to be similar or better to PLGA or stainless steel, both medically used materials. These experiments indicate that DP‐fiber fleeces or surfaces might be useful for tissue engineering. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2009
- 9 April 2009
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 91B (1) , 109-121
Cyto‐ and hemocompatibility of a biodegradable 3D‐scaffold material designed for medical applications
In this study, the polyester urethane Degrapol® (DP) was explored for medical applications. Electrospun DP‐fiber fleeces were characterized with regard to fiber morphology, swelling, and interconnectivity of interfiber spaces. Moreover, DP was assayed for cell proliferation and hemocompatibility being a prerequisite to any further in vivo application. It was shown that DP‐fiber fleeces produced at different humidity while spinning affects interconnectivity of interfiber spaces, such that the higher the humidity the looser the resulting fiber fleeces. When the spinning target was cooled with dry ice, the resulting DP‐fibers remained less fused to each other. However, permeability for fluorescent beads was not significantly increased. Fibroblast adhesion and proliferation occurred in a comparable manner on native as well as on fibronectin or collagen I adsorbed DP‐fiber fleeces. On DP‐surfaces fibroblasts proliferated equally well as compared with glass or PLGA surfaces or DP‐surfaces adsorbed with fibronectin or collagen I. In contrast, human umbilical vein endothelial cells proliferated only after adsorption of DP‐surfaces with fibronectin or collagen I, indicating that different cell types respond differently to DP‐surfaces. Furthermore, hemocompatibility of DP‐surfaces was found to be similar or better to PLGA or stainless steel, both medically used materials. These experiments indicate that DP‐fiber fleeces or surfaces might be useful for tissue engineering. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2009
- Open Access
Analysis of Effective Interconnectivity of DegraPol-foams Designed for Negative Pressure Wound Therapy
Many wounds heal slowly and are difficult to manage. Therefore Negative Pressure Wound Therapy (NPWT) was developed where polymer foams are applied and a defined negative pressure removes wound fluid, reduces bacterial burden and increases the formation of granulation tissue. Although NPWT is used successfully, its mechanisms are not well understood. In particular, different NPWT dressings were never compared. Here a poly-ester urethane Degrapol® (DP)-foam was produced and compared with commercially available dressings (polyurethane-based and polyvinyl-alcohol-based) in terms of apparent pore sizes, swelling and effective interconnectivity of foam pores. DP-foams contain relatively small interconnected pores; PU-foams showed large pore size and interconnectivity; whereas PVA-foams displayed heterogeneous and poorly interconnected pores. PVA-foams swelled by 40 %, whereas DP- and PU-foams remained almost without swelling. Effective interconnectivity was investigated by submitting fluorescent beads of 3, 20 and 45 mm diameter through the foams. DP- and PU-foams removed 70-90 % of all beads within 4 h, independent of the bead diameter or bead pre-adsorption with serum albumin. For PVA-foams albumin pre-adsorbed beads circulated longer, where 20 % of 3 mm and 10 % of 20 mm diameter beads circulated after 96 h. The studies indicate that efficient bead perfusion does not only depend on pore size and swelling capacity, but effective interconnectivity might also depend on chemical composition of the foam itself. In addition due to the efficient sieve-effect of the foams uptake of wound components in vivo might occur only for short time suggesting other mechanisms being decisive for success of NPWT.
Open AccessAnalysis of Effective Interconnectivity of DegraPol-foams Designed for Negative Pressure Wound Therapy
Many wounds heal slowly and are difficult to manage. Therefore Negative Pressure Wound Therapy (NPWT) was developed where polymer foams are applied and a defined negative pressure removes wound fluid, reduces bacterial burden and increases the formation of granulation tissue. Although NPWT is used successfully, its mechanisms are not well understood. In particular, different NPWT dressings were never compared. Here a poly-ester urethane Degrapol® (DP)-foam was produced and compared with commercially available dressings (polyurethane-based and polyvinyl-alcohol-based) in terms of apparent pore sizes, swelling and effective interconnectivity of foam pores. DP-foams contain relatively small interconnected pores; PU-foams showed large pore size and interconnectivity; whereas PVA-foams displayed heterogeneous and poorly interconnected pores. PVA-foams swelled by 40 %, whereas DP- and PU-foams remained almost without swelling. Effective interconnectivity was investigated by submitting fluorescent beads of 3, 20 and 45 mm diameter through the foams. DP- and PU-foams removed 70-90 % of all beads within 4 h, independent of the bead diameter or bead pre-adsorption with serum albumin. For PVA-foams albumin pre-adsorbed beads circulated longer, where 20 % of 3 mm and 10 % of 20 mm diameter beads circulated after 96 h. The studies indicate that efficient bead perfusion does not only depend on pore size and swelling capacity, but effective interconnectivity might also depend on chemical composition of the foam itself. In addition due to the efficient sieve-effect of the foams uptake of wound components in vivo might occur only for short time suggesting other mechanisms being decisive for success of NPWT.
- 1 December 2007
- Published by Bentham Science Publishers Ltd. in Current Pharmaceutical Design
- Vol. 13 (35) , 3597-3607
Modified Fibrin Hydrogel Matrices: Both, 3D-Scaffolds and Local and Controlled Release Systems to Stimulate Angiogenesis
Sufficient blood perfusion is essential for all tissues to guarantee nutrient- and gas exchange. As many diseases are induced by the reduction of blood perfusion such that these tissues gradually loose their ability to function properly, therapeutic angiogenesis aims to increase blood flow in ischemic tissues by stimulating the patients endogenous capacity to develop new blood vessels. These studies include application of angiogenesis stimulating (growth) factors and adhesion sequences as well as local gene therapy. One approach is to rationally design 3D-fibrin hydrogel matrices that provide specific adhesion sequences such as a receptor for αvβ3- integrin expressed on angiogenic endothelial cells and that, in addition, are able to store and release angiogenic growth factors such as VEGF-A165 and bFGF that target cell type-specific responses. Moreover, these matrices can be modified to release complexed plasmid DNA that transfect surrounding cells and improve angiogenesis. During wound healing, cells infiltrate into the scaffold and degrade it, thereby releasing entrapped growth factors or complexed plasmid DNA, and with the speed of tissue regeneration the scaffold is completely removed when tissue healing is achieved. The long-term aim is to develop biomimetic 3D-matrices for applications in a biomaterials context that can be applied directly at the site of injury by minimal invasive surgery. 3D-fibrin matrices constitute a scaffold and release system for single or combined therapeutic biomolecules and may therefore be able to contribute to the patients endogenous healing response resulting in the functional recovery of a diseased tissue or organ.
- 1 December 2007
- Published by Bentham Science Publishers Ltd. in Current Pharmaceutical Design
- Vol. 13 (35) , 3597-3607
Modified Fibrin Hydrogel Matrices: Both, 3D-Scaffolds and Local and Controlled Release Systems to Stimulate Angiogenesis
Sufficient blood perfusion is essential for all tissues to guarantee nutrient- and gas exchange. As many diseases are induced by the reduction of blood perfusion such that these tissues gradually loose their ability to function properly, therapeutic angiogenesis aims to increase blood flow in ischemic tissues by stimulating the patients endogenous capacity to develop new blood vessels. These studies include application of angiogenesis stimulating (growth) factors and adhesion sequences as well as local gene therapy. One approach is to rationally design 3D-fibrin hydrogel matrices that provide specific adhesion sequences such as a receptor for αvβ3- integrin expressed on angiogenic endothelial cells and that, in addition, are able to store and release angiogenic growth factors such as VEGF-A165 and bFGF that target cell type-specific responses. Moreover, these matrices can be modified to release complexed plasmid DNA that transfect surrounding cells and improve angiogenesis. During wound healing, cells infiltrate into the scaffold and degrade it, thereby releasing entrapped growth factors or complexed plasmid DNA, and with the speed of tissue regeneration the scaffold is completely removed when tissue healing is achieved. The long-term aim is to develop biomimetic 3D-matrices for applications in a biomaterials context that can be applied directly at the site of injury by minimal invasive surgery. 3D-fibrin matrices constitute a scaffold and release system for single or combined therapeutic biomolecules and may therefore be able to contribute to the patients endogenous healing response resulting in the functional recovery of a diseased tissue or organ.
- 21 February 2006
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 77A (3) , 542-550
Activation of cell‐survival transcription factor NFκB in L1Ig6‐stimulated endothelial cells
Ligation of the integrin αvβ3 in endothelial cells has been shown to be important for their survival. Such ligation induces signalling events merging into the Raf-Ras-ERK cascade that eventually induces activation of nuclear factor kappa B (NFκB), leading to its phosphorylation and nuclear translocation and thus inhibiting apoptosis. Here, the recombinant sixth immunoglobulin-like domain of cell adhesion molecules L1 (L1Ig6), a ligand for integrin αvβ3, was explored as a component of vascular implant surfaces to initiate the NFκB-cell survival pathway. This supposition was supported. Specifically, NFκB-p65 was expressed in human umbilical vein endothelial cells (HUVECs) and when stimulated on L1Ig6, the phosphorylated form was found in the nucleus in over 60% of the cells. NFκB was not translocated into the nucleus on a number of other extracellular matrix substrates examined or when fibroblasts were cultured on L1Ig6. NFκB phosphorylation and nuclear translocation could be inhibited by blocking ligation of αvβ3 by L1Ig6 with an antibody recognizing αvβ3, with a cyclic RGD peptide, and with soluble L1Ig6. Moreover, blocking of αvβ3 interaction with L1Ig6 was correlated with induction of apoptosis. Thus, these experiments demonstrate that L1Ig6 may be useful as αvβ3 ligand for the induction of endothelial survival pathways mediated by NFκB-p65. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
- 21 February 2006
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 77A (3) , 542-550
Activation of cell‐survival transcription factor NFκB in L1Ig6‐stimulated endothelial cells
Ligation of the integrin αvβ3 in endothelial cells has been shown to be important for their survival. Such ligation induces signalling events merging into the Raf-Ras-ERK cascade that eventually induces activation of nuclear factor kappa B (NFκB), leading to its phosphorylation and nuclear translocation and thus inhibiting apoptosis. Here, the recombinant sixth immunoglobulin-like domain of cell adhesion molecules L1 (L1Ig6), a ligand for integrin αvβ3, was explored as a component of vascular implant surfaces to initiate the NFκB-cell survival pathway. This supposition was supported. Specifically, NFκB-p65 was expressed in human umbilical vein endothelial cells (HUVECs) and when stimulated on L1Ig6, the phosphorylated form was found in the nucleus in over 60% of the cells. NFκB was not translocated into the nucleus on a number of other extracellular matrix substrates examined or when fibroblasts were cultured on L1Ig6. NFκB phosphorylation and nuclear translocation could be inhibited by blocking ligation of αvβ3 by L1Ig6 with an antibody recognizing αvβ3, with a cyclic RGD peptide, and with soluble L1Ig6. Moreover, blocking of αvβ3 interaction with L1Ig6 was correlated with induction of apoptosis. Thus, these experiments demonstrate that L1Ig6 may be useful as αvβ3 ligand for the induction of endothelial survival pathways mediated by NFκB-p65. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
- 19 December 2005
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 36 (12) , 768-774
Modified Fibrin Hydrogels stimulate Angiogenesisin vivo: potential Application to increase Perfusion of Ischemic Tissues
- 19 December 2005
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 36 (12) , 768-774
Modified Fibrin Hydrogels stimulate Angiogenesisin vivo: potential Application to increase Perfusion of Ischemic Tissues