LKLeo H. Koole

Leo H. Koole

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Leo H. Koole has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Frederik H. van der Veen

    Department of Cardiothoracic Surgery, Academic Hospital Maastricht, P.O. Box 5800, 6200 MD Maastricht, The Netherlands

    3 shared publications
  • Menno L. W. Knetsch

    Centre for Biomaterials Research, University of Maastricht, PO Box 616, 6200 MD Maastricht, The Netherlands

    2 shared publications
  • Roel Kuijer

    Department of Biomedical Engineering, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands

    2 shared publications
  • Yvette B. J. Aldenhoff

    Centre for Biomaterials Research, University of Maastricht, P.O. Box 616, 6200 MD Maastricht, The Netherlands

    2 shared publications
  • Bram J. Stelt

    Faculty of Biomedical Engineering, Eindhoven University of Technology & University of Maastricht, Netherlands

    1 shared publication
  • Camiel C. L. Peerlings

    Center for Biomaterials Research, University of Maastricht, P O Box 616, 6200 MD Maastricht, Netherlands

    1 shared publication

Latest Publications

  • Open Access

    Polymeric Microspheres for Medical Applications

    by Ketie Saralidze, Leo H. Koole, Menno L.W. Knetsch

    Synthetic polymeric microspheres find application in a wide range of medical applications. Among other applications, microspheres are being used as bulking agents, embolic- or drug-delivery particles. The exact composition of the spheres varies with the application and therefore a large array of materials has been used to produce microspheres. In this review, the relation between microsphere synthesis and application is discussed for a number of microspheres that are used for different treatment strategies.


  • Open Access

    Bioengineering of Improved Biomaterials Coatings for Extracorporeal Circulation Requires Extended Observation of Blood-Biomaterial Interaction under Flow

    by Kris N. J. Stevens, Yvette B. J. Aldenhoff, Frederik H. van der Veen, Jos G. Maessen, Leo H. Koole

    Extended use of cardiopulmonary bypass (CPB) systems is often hampered by thrombus formation and infection. Part of these problems relates to imperfect hemocompatibility of the CPB circuitry. The engineering of biomaterial surfaces with genuine long-term hemocompatibility is essentially virgin territory in biomaterials science. For example, most experiments with the well-known Chandler loop model, for evaluation of blood-biomaterial interactions under flow, have been described for a maximum duration of 2 hours only. This study reports a systematic evaluation of two commercial CPB tubings, each with a hemocompatible coating, and one uncoated control. The experiments comprised (i) testing over 5 hours under flow, with human whole blood from 4 different donors; (ii) measurement of essential blood parameters of hemocompatibility; (iii) analysis of the luminal surfaces by scanning electron microscopy and thrombin generation time measurements. The dataset indicated differences in hemocompatibility of the tubings. Furthermore, it appeared that discrimination between biomaterial coatings can be made only after several hours of blood-biomaterial contact. Platelet counting, myeloperoxidase quantification, and scanning electron microscopy proved to be the most useful methods. These findings are believed to be relevant with respect to the bioengineering of extracorporeal devices that should function in contact with blood for extended time.


  • Biocompatibility of a new radiopaque iodine‐containing acrylic bone cement

    by Catharina S. J. van Hooy‐Corstjens, Sjoerd K. Bulstra, Menno L. W. Knetsch, Piet Geusens, Roel Kuijer, Leo H. Koole

    Radiopacity in the vast majority of the commercially available acrylic bone cements that are used clinically is provided by particles of either BaSO4 or ZrO2. Literature reports have shown these agents to have a detrimental effect on some mechanical properties of the cements as well as on its biological response. We, therefore, have developed a new type of bone cement, for which radiopacity results from the presence of an iodine‐containing methacrylic copolymer. The focus of the present work was the comparison of the biocompatibility of this new cement and a commercially available cement that contains barium sulfate. In vitro experiments show that both cements are cytocompatible materials, for which no toxic leachables are found. Implantation of the cements in a rabbit for three months resulted in the occasional presence of a thin fibrous tissue at the cement–bone interface, which is common for acrylic bone cements. Consideration of all the results led to the conclusion that the new cement is as biocompatible as the BaSO4‐containing one. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007


  • Development of new injectable bulking agents: Biocompatibility of radiopaque polymeric microspheres studied in a mouse model

    by Pieter J. Emans, Ketie Saralidze, Menno L. W. Knetsch, Marion J. J. Gijbels, Roel Kuijer, Leo H. Koole

    Radiopaque polymeric microspheres have a potential as new bulking agents for treatment of stress urinary incontinence (SUI). The advantage over existing bulking agents lies in their X‐ray visibility in situ; other polymeric bulking agents (e.g., PTFE or silicone rubbers) are practically radiolucent (i.e., incapable of absorbing X‐radiation). Radiopacity is useful in practice because of the high spatial accuracy of X‐ray imaging. For instance, X‐ray fluoroscopy can be used to assess possible migration of the bulking agent over time or to provide guidance in cases in which a second injection of a bulking agent is necessary (repeated treatment of SUI). Biocompatibility of injected radiopaque microspheres was investigated in vivo by using the mouse as a model. Microspheres were injected subcutaneously (9 animals) or intramuscularly (9 animals), and follow‐up was 8 days or 3 months. X‐ray fluoroscopy gave clear images of the miscrospheres as an ensemble, and it was found that no migration occurred during 3 months. Histopathology confirmed that all microspheres stayed close to the site of the injection. The microspheres appeared to be well tolerated; only a few giant cells, manifesting a mild inflammatory reaction, were encountered. At 3 months, cappillary blood vessels were observed throughout the microsphere beds, and macrophages and fibroblast cells were seen in between the microspheres. This is encouraging with respect to the intended application, although it must be acknowledged that the data refer merely to a mouse model. Further experiments with larger, more representative models (rabbit and goat) are in progress. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005


    • 1 September 2002
      • Vol. 13  (7) , 20-2

    Heparin-releasing intravascular guidewires.

    by Hans J L Hanssen, Leo H Koole

    The distal part of a percutaneous translumenal coronary angioplasty (PTCA) guidewire should not only be flexible, nonkinking, radiopaque and lubricious, but also nonthrombogenic. Possible formation of thrombotic emboli at a guidewire's surface enhances the risk for occlusion at the coronary lesion downstream. This article reports on the development of a new PTCA guidewire that releases heparin from the lubricious hydrophilic coating on its distal part.

  • Heparin release from slippery‐when‐wet guide wires for intravascular use

    by Camiel C. L. Peerlings, Hans H. L. Hanssen, Raymond T. J. Bevers, Erik J. H. Boelen, Bram J. Stelt, Eva J. M. Korthagen, Leo H. Koole

    Thin metallic wires with an adherent hydrophilic/ lubricious polymeric coating were manufactured in a new extrusion‐like procedure. This procedure is part of a novel and efficient way of assembling lubricious guide wires for intravascular interventions, such as percutaneous transluminal angioplasty. It is reported that heparin can readily be incorporated in the hydrophilic coating. A set of heparin‐containing guidewire models was made and studied in detail. This showed that (i) immersion of the guide‐wire models in an aqueous environment leads to release of heparin from their surface; (ii) the presence of heparin in the coating does not impede the lubricity of the coils; (iii) addition of stearic acid in the coating, next to heparin, does not influence the lubricity of the guide‐wire models. Two different charges of heparin (designated heparin‐low and heparin‐high) were incorporated in the coating. It is discussed that release of heparin from the surface of medical devices (e.g. guide wires and catheters) is much more effective than systemic heparinization, basically because dissolved heparin molecules have a much larger probability of simply passing a medical device's surface (axial convection) rather than contacting it (radial diffusion). © 2002 Wiley Periodicals, Inc. J Biomed Mater Res (Appl Biomater) 63: 692–698, 2002


  • Performance of a polyurethane vascular prosthesis carrying a dipyridamole (Persantin ) coating on its lumenal surface

    by Yvette B. J. Aldenhoff, Frederik H. van der Veen, Joost ter Woorst, Jo Habets, Laura A. Poole-Warren, Leo H. Koole

    A porous polyurethane vascular prosthesis with an internal diameter of 5 mm was studied. The graft carries a coating of immobilized dipyridamole (Persantin®) on the surface of its lumen. Dipyridamole is a potent nontoxic inhibitor of platelet activation/aggregation, and also a strong inhibitor of vascular smooth muscle cell proliferation. The polyurethane material is also known as Chronoflex®, and already finds use as a vascular access graft. The coated vascular graft was studied in vitro (hemocompatibility, interaction with blood platelets and cultured endothelial cells), as well as in two established in vivo models. In the first in vivo study, coated grafts were implanted in goats, as a bypass of the carotid artery (four animals, eight grafts, length of the graft was approximately 12 cm). Four uncoated grafts were used as controls in otherwise identical experiments. In the second in vivo experiment, eight sheep were used. Each animal received one coated and one uncoated prosthesis as an interposition graft in the carotid artery (length of the graft was 4 cm). The in vitro experiments revealed that the dipyridamole coating has three beneficial effects: reduced thrombogenicity, reduced adherence of blood platelets, and accommodation of a confluent monolayer of endothelial cells. The goat experiments showed patency of the coated grafts in three of the eight cases. The sheep experiments were not useful for the evaluation of the dipyridamole coating because deterioration of the polyurethane material was observed. The in vivo results indicate that the dipyridamole coating may positively influence the patency rate, probably because the coating promotes the growth of an endothelial cell lining. The sheep data show, however, that the limited stability of the Chronoflex® material precludes its issue for the construction of permanent small‐bore vascular grafts. © 2000 John Wiley & Sons, Inc. J Biomed Mater Res 54: 224–233, 2001


  • New biodegradable networks of poly(N-vinylpyrrolidinone) designed for controlled nonburst degradation in the vitreous body

    by Monique J. Bruining, Petra S. Edelbroek‐Hoogendoorn, Harriët G. T. Blaauwgeers, Cornelia M. Mooy, Fred H. Hendrikse, Leo H. Koole

    Polymers of N-vinylpyrrolidinone (NVP) are known to have excellent biocompatibility when implanted in the vitreous body or used as a vitreous substitute. Although poly(NVP) is capable of absorbing relatively large amounts of water, it is not prone to hydrolysis. Yet intraocular degradation of several crosslinked poly(NVP) hydrogels has been reported recently, but some ambiguity remains about the exact mechanism of degradation of these materials. To date there is no biomaterial that combines the excellent intraocular biocompatibility on the one hand and controlled kinetics of degradation on the other hand. We attempted to design and prepare such materials through the chemical synthesis of a novel dimethacrylate crosslinker molecule. The essential feature of this molecule is that its core contains two carbonate groups, which are evidently susceptible to hydrolytic scission. We studied a series of 3-dimensional networks of poly(NVP), which were crosslinked by this molecule. This approach offers several advantages: the hydrolysis of the carbonate groups in the crosslinks leads to liberation of poly(NVP) and/or oligo(NVP) chains that can probably be cleared from the eye via phagocytosis; hydrolysis generates two alcohols and CO2 (i.e., there is no catalytic burst effect); when these materials are implanted in dry form, swelling and degradation will progress from the exterior of the material toward its interior. Therefore, these materials can be designed such that surface degradation rather than bulk degradation occurs; the hydrolysis rate can be controlled via the crosslink density or through synthesis of other crosslink molecules with either more (>2) or less (1) carbonate groups or alternatively with one or more other labile groups. We report on the chemical synthesis of the crosslinker molecule, as well as the preparation and degradation of a series of poly(NVP)-based hydrogels in vitro and in vivo (rabbit eyes). We found that these materials indeed displayed excellent biocompatibility in the rabbit eye. Further, the experiments confirmed that degradation occurs without the burst effect. The results are in line with the idea that the rate of intraocular swelling and degradation depends on the crosslink density, but this is only a preliminary conclusion that must be strengthened by much more experimental work. Nonetheless, we foresee several applications of these or related materials in ophthalmology, for example, as biodegradable matrix materials for controlled drug delivery of ganciclovir in the vitreous body. © 1999 John Wiley & Sons, Inc. J Biomed Mater Res, 47, 189–197, 1999.


  • Sustained local drug delivery from a radiopaque implanted reservoir

    by Leo H. Koole, Marc-Anton B. Kruft, Yvette B.J. Aldenhoff, Nicolette E. van 'T Oost, Marinus J.P.G. van Kroonenburgh, Frederik H. van der Veen

    A new polymeric biomaterial that contains covalently bound iodine, and is therefore radiopaque, was used to construct a sustained local drug-delivery device. A polymeric wall was designed to be porous (i.e., passage of low-molecular-weight molecules across the wall is possible), self-healing, and biocompatible. Once implanted, the sphere cavity can be filled and refilled with a concentrated solution of a (cytostatic) drug, which is subsequently released by slow diffusion into the tissue region surrounding the sphere. This principle of sustained local drug delivery is shown by a series of in vitro experiments on the release of 5-fluorouracil, and in vivo animal experiments, using x-ray fluoroscopic and scintigraphic techniques.