Mark A. Elliott
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mark A. Elliott has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Klaus Mathiak
Department of Psychiatry, Psychotherapy and Psychosomatics, Medical School, RWTH Aachen University, Aachen, Germany
2 shared publications - Yury Koush
Vladimir Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology
2 shared publications - Birkan Tunc
Center for Autism Research, Children’s Hospital of Philadelphia, Philadelphia, USA
1 shared publication - Catherine DeBrosse
Center for Magnetic Resonance and Optical Imaging, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
1 shared publication - Chevonne Parris-Skeete
Division of Endocrinology and Diabetes, The Children's Hospital of Philadelphia
1 shared publication David R. Lynch
Department of Neurology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
1 shared publication
Latest Publications
- Open Access
Closed-loop control of k-space sampling via physiologic feedback for cine MRI
Background: Segmented cine cardiac MRI combines data from multiple heartbeats to achieve high spatiotemporal resolution cardiac images, yet predefined k-space segmentation trajectories can lead to suboptimal k-space sampling. In this work, we developed and evaluated an autonomous and closed-loop control system for radial k-space sampling to increase sampling uniformity. Methods: The closed-loop system autonomously selects radial k-space sampling trajectory during live segmented cine MRI and attempts to optimize angular sampling uniformity by selecting views in regions of k-space that were not previously well-sampled. Sampling uniformity and robustness to arrhythmias was assessed using ECG data acquired from 10 normal subjects in an MRI scanner. The approach was then implemented with a fast gradient echo sequence on a whole-body clinical MRI scanner and imaging was performed in 4 healthy volunteers. The closed-loop k-space trajectory was compared to random, uniformly distributed and golden angle view trajectories via measurement of k-space uniformity and the point spread function. Lastly, an arrhythmic dataset was used to evaluate a potential application of the approach. Results: The autonomous trajectory increased k-space sampling uniformity by 13±7%, main lobe point spread function (PSF) signal intensity by 14±6%, and reduced ringing relative to golden angle sampling. When implemented, the autonomous pulse sequence prescribed radial view angles faster than the scan TR (0.98 ± 0.02 ms, maximum = 1.38 ms) and increased k-space sampling mean uniformity by 5±12%, decreased uniformity variability by 45±14%, and increased PSF signal ratio by 5±5% relative to golden angle sampling. Conclusion: The closed-loop approach enables near-uniform radial sampling in a segmented acquisition approach which was higher than predetermined golden-angle radial sampling. This can be utilized to increase the sampling or decrease the temporal footprint of an acquisition and the closed-loop framework has the potential to be applied to patients with complex heart rhythms.
Open AccessClosed-loop control of k-space sampling via physiologic feedback for cine MRI
Background: Segmented cine cardiac MRI combines data from multiple heartbeats to achieve high spatiotemporal resolution cardiac images, yet predefined k-space segmentation trajectories can lead to suboptimal k-space sampling. In this work, we developed and evaluated an autonomous and closed-loop control system for radial k-space sampling to increase sampling uniformity. Methods: The closed-loop system autonomously selects radial k-space sampling trajectory during live segmented cine MRI and attempts to optimize angular sampling uniformity by selecting views in regions of k-space that were not previously well-sampled. Sampling uniformity and robustness to arrhythmias was assessed using ECG data acquired from 10 normal subjects in an MRI scanner. The approach was then implemented with a fast gradient echo sequence on a whole-body clinical MRI scanner and imaging was performed in 4 healthy volunteers. The closed-loop k-space trajectory was compared to random, uniformly distributed and golden angle view trajectories via measurement of k-space uniformity and the point spread function. Lastly, an arrhythmic dataset was used to evaluate a potential application of the approach. Results: The autonomous trajectory increased k-space sampling uniformity by 13±7%, main lobe point spread function (PSF) signal intensity by 14±6%, and reduced ringing relative to golden angle sampling. When implemented, the autonomous pulse sequence prescribed radial view angles faster than the scan TR (0.98 ± 0.02 ms, maximum = 1.38 ms) and increased k-space sampling mean uniformity by 5±12%, decreased uniformity variability by 45±14%, and increased PSF signal ratio by 5±5% relative to golden angle sampling. Conclusion: The closed-loop approach enables near-uniform radial sampling in a segmented acquisition approach which was higher than predetermined golden-angle radial sampling. This can be utilized to increase the sampling or decrease the temporal footprint of an acquisition and the closed-loop framework has the potential to be applied to patients with complex heart rhythms.
- Open Access
Multifactorial Dynamics of White Matter Connectivity During Adolescence
Studying developmental changes in white matter connectivity is critical for understanding neurobiological substrates of cognition, learning, and neuropsychiatric disorders. This becomes especially important during adolescence when a rapid expansion of the behavioral repertoire occurs. Several factors such as brain geometry, genetic expression profiles, and higher level architectural specifications such as the presence of segregated modules have been associated with the observed organization of white matter connections. However, we lack understanding of the extent to which such factors jointly describe the brain network organization, nor have insights into how their contribution changes developmentally. We constructed a multifactorial model of white matter connectivity using Bayesian network analysis and tested it with diffusion imaging data from a large community sample. We investigated contributions of multiple factors in explaining observed connectivity, including architectural specifications, which promote a modular yet integrative organization, and brain’s geometric and genetic features. Our results demonstrated that the initially dominant geometric and genetic factors become less influential with age, whereas the effect of architectural specifications increases. The identified structural modules are associated with well-known functional systems, and the level of association increases with age. This integrative analysis provides a computational characterization of the normative evolution of structural connectivity during adolescence.
Open AccessMultifactorial Dynamics of White Matter Connectivity During Adolescence
Studying developmental changes in white matter connectivity is critical for understanding neurobiological substrates of cognition, learning, and neuropsychiatric disorders. This becomes especially important during adolescence when a rapid expansion of the behavioral repertoire occurs. Several factors such as brain geometry, genetic expression profiles, and higher level architectural specifications such as the presence of segregated modules have been associated with the observed organization of white matter connections. However, we lack understanding of the extent to which such factors jointly describe the brain network organization, nor have insights into how their contribution changes developmentally. We constructed a multifactorial model of white matter connectivity using Bayesian network analysis and tested it with diffusion imaging data from a large community sample. We investigated contributions of multiple factors in explaining observed connectivity, including architectural specifications, which promote a modular yet integrative organization, and brain’s geometric and genetic features. Our results demonstrated that the initially dominant geometric and genetic factors become less influential with age, whereas the effect of architectural specifications increases. The identified structural modules are associated with well-known functional systems, and the level of association increases with age. This integrative analysis provides a computational characterization of the normative evolution of structural connectivity during adolescence.
- Open Access
- 3 November 2016
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 1 (18) , e88207
Muscle oxidative phosphorylation quantitation using creatine chemical exchange saturation transfer (CrCEST) MRI in mitochondrial disorders
Systemic mitochondrial energy deficiency is implicated in the pathophysiology of many age-related human diseases. Currently available tools to estimate mitochondrial oxidative phosphorylation (OXPHOS) capacity in skeletal muscle in vivo lack high anatomic resolution. Muscle groups vary with respect to their contractile and metabolic properties. Therefore, muscle group–specific estimates of OXPHOS would be advantageous. To address this need, a noninvasive creatine chemical exchange saturation transfer (CrCEST) MRI technique has recently been developed, which provides a measure of free creatine. After exercise, skeletal muscle can be imaged with CrCEST in order to make muscle group–specific measurements of OXPHOS capacity, reflected in the recovery rate (τCr) of free Cr. In this study, we found that individuals with genetic mitochondrial diseases had significantly ( P = 0.026) prolonged postexercise τCr in the medial gastrocnemius muscle, suggestive of less OXPHOS capacity. Additionally, we observed that lower resting CrCEST was associated with prolonged τPCr, with a Pearson’s correlation coefficient of –0.42 ( P = 0.046), consistent with previous hypotheses predicting that resting creatine levels may correlate with 31 P magnetic resonance spectroscopy–based estimates of OXPHOS capacity. We conclude that CrCEST can noninvasively detect changes in muscle creatine content and OXPHOS capacity, with high anatomic resolution, in individuals with mitochondrial disorders.
- 3 November 2016
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 1 (18) , e88207
Open AccessMuscle oxidative phosphorylation quantitation using creatine chemical exchange saturation transfer (CrCEST) MRI in mitochondrial disorders
Systemic mitochondrial energy deficiency is implicated in the pathophysiology of many age-related human diseases. Currently available tools to estimate mitochondrial oxidative phosphorylation (OXPHOS) capacity in skeletal muscle in vivo lack high anatomic resolution. Muscle groups vary with respect to their contractile and metabolic properties. Therefore, muscle group–specific estimates of OXPHOS would be advantageous. To address this need, a noninvasive creatine chemical exchange saturation transfer (CrCEST) MRI technique has recently been developed, which provides a measure of free creatine. After exercise, skeletal muscle can be imaged with CrCEST in order to make muscle group–specific measurements of OXPHOS capacity, reflected in the recovery rate (τCr) of free Cr. In this study, we found that individuals with genetic mitochondrial diseases had significantly ( P = 0.026) prolonged postexercise τCr in the medial gastrocnemius muscle, suggestive of less OXPHOS capacity. Additionally, we observed that lower resting CrCEST was associated with prolonged τPCr, with a Pearson’s correlation coefficient of –0.42 ( P = 0.046), consistent with previous hypotheses predicting that resting creatine levels may correlate with 31 P magnetic resonance spectroscopy–based estimates of OXPHOS capacity. We conclude that CrCEST can noninvasively detect changes in muscle creatine content and OXPHOS capacity, with high anatomic resolution, in individuals with mitochondrial disorders.
- Open Access
Correction: Koush, Y.; Elliott, M.A. and Mathiak, K. Single Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla. Materials 2011, 4, 1548–1563
In the published manuscript “Koush, Y.; Elliott, M.A. and Mathiak, K. Single Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla. Materials 2011, 4, 1548-1563”, all estimates of T2* from the single voxel spectroscopy data were overestimated by a factor of 4. This was due to an incorrectly assumed four-fold lower sampling rate. The focus of the manuscript is on the relative changes in T2* with BOLD activation, and not on the absolute values. Therefore, none of the central claims are affected, but the scaling in most of the figures needs to be adjusted. The authors would like to make the following corrections to their published paper.
Open AccessCorrection: Koush, Y.; Elliott, M.A. and Mathiak, K. Single Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla. Materials 2011, 4, 1548–1563
In the published manuscript “Koush, Y.; Elliott, M.A. and Mathiak, K. Single Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla. Materials 2011, 4, 1548-1563”, all estimates of T2* from the single voxel spectroscopy data were overestimated by a factor of 4. This was due to an incorrectly assumed four-fold lower sampling rate. The focus of the manuscript is on the relative changes in T2* with BOLD activation, and not on the absolute values. Therefore, none of the central claims are affected, but the scaling in most of the figures needs to be adjusted. The authors would like to make the following corrections to their published paper.
- Open Access
Single Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla
Echo-planar imaging (EPI) in fMRI is regularly used to reveal BOLD activation in presubscribed regions of interest (ROI). The response is mediated by relative changes in T2* which appear as changes in the image pixel intensities. We have proposed an application of functional single-voxel proton spectroscopy (fSVPS) for real-time studies at ultra-high MR field which can be comparable to the EPI BOLD fMRI technique. A spin-echo SVPS protocol without water suppression was acquired with 310 repetitions on a 7T Siemens MR scanner (TE/TR = 20/1000 ms, flip angle α = 90°, voxel size 10 × 10 × 10 mm3). Transmitter reference voltage was optimized for the voxel location. Spectral processing of the water signal free induction decay (FID) using log-linear regression was used to estimate the T2* change between rest and activation of a functional task. The FID spectrum was filtered with a Gaussian window around the water peak, and log-linear regression was optimized for the particular ROI by adoption of the linearization length. The spectroscopic voxel was positioned on an ROI defined from a real-time fMRI EPI BOLD localizer. Additional online signal processing algorithms performed signal drift removal (exponential moving average), despiking and low-pass filtering (modified Kalman filter) and, finally, the dynamic feedback signal normalization. Two functional tasks were used to estimate the sensitivity of the SVPS method compared to BOLD signal changes, namely the primary motor cortex (PMC, left hand finger tapping) and visual cortex (VC, blinking checkerboard). Four healthy volunteers performed these tasks and an additional session using real-time signal feedback modulating their activation level of the PMC. Results show that single voxel spectroscopy is able to provide a good and reliable estimation of the BOLD signal changes. Small data size and FID signal processing instead of processing entire brain volumes as well as more information revealed from the acquired total water spectrum, i.e., direct estimation of the T2* values and B0 changes, make SVPS proton spectroscopy suitable and advantageous for real-time neurofeedback studies. Particular challenges of ultra-high field spectroscopy due to the non-linearity in the spectral information, e.g., poor main magnetic field homogeneity and the absence of motion correction for the SVPS sequence may lead to the special artifacts in the control signal which still need to be addressed. The contrast to noise ratio (CNR), experimental statistic (t-values) and percent signal change were used as quality parameters to estimate the method performance. The potential and challenges of the spectroscopic approach for fMRI studies needs to be further investigated.
Open AccessSingle Voxel Proton Spectroscopy for Neurofeedback at 7 Tesla
Echo-planar imaging (EPI) in fMRI is regularly used to reveal BOLD activation in presubscribed regions of interest (ROI). The response is mediated by relative changes in T2* which appear as changes in the image pixel intensities. We have proposed an application of functional single-voxel proton spectroscopy (fSVPS) for real-time studies at ultra-high MR field which can be comparable to the EPI BOLD fMRI technique. A spin-echo SVPS protocol without water suppression was acquired with 310 repetitions on a 7T Siemens MR scanner (TE/TR = 20/1000 ms, flip angle α = 90°, voxel size 10 × 10 × 10 mm3). Transmitter reference voltage was optimized for the voxel location. Spectral processing of the water signal free induction decay (FID) using log-linear regression was used to estimate the T2* change between rest and activation of a functional task. The FID spectrum was filtered with a Gaussian window around the water peak, and log-linear regression was optimized for the particular ROI by adoption of the linearization length. The spectroscopic voxel was positioned on an ROI defined from a real-time fMRI EPI BOLD localizer. Additional online signal processing algorithms performed signal drift removal (exponential moving average), despiking and low-pass filtering (modified Kalman filter) and, finally, the dynamic feedback signal normalization. Two functional tasks were used to estimate the sensitivity of the SVPS method compared to BOLD signal changes, namely the primary motor cortex (PMC, left hand finger tapping) and visual cortex (VC, blinking checkerboard). Four healthy volunteers performed these tasks and an additional session using real-time signal feedback modulating their activation level of the PMC. Results show that single voxel spectroscopy is able to provide a good and reliable estimation of the BOLD signal changes. Small data size and FID signal processing instead of processing entire brain volumes as well as more information revealed from the acquired total water spectrum, i.e., direct estimation of the T2* values and B0 changes, make SVPS proton spectroscopy suitable and advantageous for real-time neurofeedback studies. Particular challenges of ultra-high field spectroscopy due to the non-linearity in the spectral information, e.g., poor main magnetic field homogeneity and the absence of motion correction for the SVPS sequence may lead to the special artifacts in the control signal which still need to be addressed. The contrast to noise ratio (CNR), experimental statistic (t-values) and percent signal change were used as quality parameters to estimate the method performance. The potential and challenges of the spectroscopic approach for fMRI studies needs to be further investigated.