SSShigeru Sase

Shigeru Sase

*This is an algorithmically generated author record based on publicly available information.

Shigeru Sase has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Discrimination between patients with mild Alzheimer's disease and healthy subjects based on cerebral blood flow images of the lateral views in xenon‐enhanced computed tomography

    by Shigeru Sase, Homaro Yamamoto, Ena Kawashima, Xin Tan, Yutaka Sawa

    Background: Quantitative cerebral blood flow (CBF) measurement is expected to help early detection of functional abnormalities caused by Alzheimer's disease (AD) and enable AD treatment to begin in its early stages. Recently, a technique of layer analysis was reported that allowed CBF to be analyzed from the outer to inner layers of the brain. The aim of this work was to develop methods for discriminating between patients with mild AD and healthy subjects based on CBF images of the lateral views created with the layer analysis technique in xenon‐enhanced computed tomography.Methods: Xenon‐enhanced computed tomography using a wide‐volume CT was performed on 17 patients with mild AD aged 75 or older and on 15 healthy age‐matched volunteers. For each subject, we created CBF images of the right and left lateral views with a depth of 10–15 mm from the surface of the brain. Ten circular regions of interest (ROI) were placed on each image, and CBF was calculated for each ROI. We determined discriminant ROI that had CBF that could be used to differentiate between the AD and volunteer groups. AD patients’ CBF range (mean − SD to mean + SD) and healthy volunteers’ CBF range (mean − SD to mean + SD) were obtained for each ROI. Receiver–operator curves were created to identify patients with AD for each of the discriminant ROI and for the AD patients’ and healthy volunteers’ CBF ranges.Results: We selected an ROI on both the right and left temporal lobes as the discriminant ROI. Areas under the receiver–operator curve were 93.3% using the ROI on the right temporal lobe, 95.3% using the ROI on the left temporal lobe, and 92.4% using the AD patients’ and healthy volunteers’ CBF ranges.Conclusions: We could effectively discriminate between patients with mild AD and healthy subjects using ROI placed on CBF images of the lateral views in xenon‐enhanced computed tomography.


  • Open Access

    Correlations of Hepatic Hemodynamics, Liver Function, and Fibrosis Markers in Nonalcoholic Fatty Liver Disease: Comparison with Chronic Hepatitis Related to Hepatitis C Virus

    by Ryuta Shigefuku, Hideaki Takahashi, Hiroyasu Nakano, Tsunamasa Watanabe, Kotaro Matsunaga, Nobuyuki Matsumoto, Masaki Kato, Ryo Morita, Yousuke Michikawa, Tomohiro Tamura, et al.

    The progression of chronic liver disease differs by etiology. The aim of this study was to elucidate the difference in disease progression between chronic hepatitis C (CHC) and nonalcoholic fatty liver disease (NAFLD) by means of fibrosis markers, liver function, and hepatic tissue blood flow (TBF). Xenon computed tomography (Xe-CT) was performed in 139 patients with NAFLD and 152 patients with CHC (including liver cirrhosis (LC)). The cutoff values for fibrosis markers were compared between NAFLD and CHC, and correlations between hepatic TBF and liver function tests were examined at each fibrosis stage. The cutoff values for detection of the advanced fibrosis stage were lower in NAFLD than in CHC. Although portal venous TBF (PVTBF) correlated with liver function tests, PVTBF in initial LC caused by nonalcoholic steatohepatitis (NASH-LC) was significantly lower than that in hepatitis C virus (C-LC) (p = 0.014). Conversely, the liver function tests in NASH-LC were higher than those in C-LC (p < 0.05). It is important to recognize the difference between NAFLD and CHC. We concluded that changes in hepatic blood flow occurred during the earliest stage of hepatic fibrosis in patients with NAFLD; therefore, patients with NAFLD need to be followed carefully.


  • Open Access

    Evaluation of Hepatic Tissue Blood Flow Using Xenon Computed Tomography with Fibrosis Progression in Nonalcoholic Fatty Liver Disease: Comparison with Chronic Hepatitis C

    by Ryuta Shigefuku, Hideaki Takahashi, Masaki Kato, Yoshihito Yoshida, Keigo Suetani, Yohei Noguchi, Moriaki Hatsugai, Kazunari Nakahara, Hiroki Ikeda, Minoru Kobayashi, et al.

    Aims: The present study evaluated the utility of xenon computed tomography (Xe-CT) as a noninvasive diagnostic procedure for the measurement of hepatic tissue blood flow (TBF) in patients with nonalcoholic fatty liver disease (NAFLD) or chronic hepatitis C (CH-C). Methods: Xe-CT was performed in 93 patients with NAFLD and in 109 patients with CH-C. Subjects were classified into one of three groups, based on fibrosis stage: group 1, no bridging fibrosis; group 2, bridging fibrosis; and group 3, liver cirrhosis. Correlations between hepatic TBFs in each fibrosis stage were examined. Results: In group 1, portal venous TBF (PVTBF), hepatic arterial (HATBF), and total hepatic TBF (THTBF) were significantly lower in patients with in nonalcoholic steatohepatitis (NASH) than in those with CH-C (p < 0.001, p < 0.05, p < 0.001, respectively). In group 2, PVTBF and THTBF were significantly lower in patients with in NASH than in those with CH-C (p < 0.001, p < 0.05, respectively). In group 3, hepatic TBFs were not significantly different when comparing patients with NASH and those with CH-C. Conclusions: PVTBF decreased due to fat infiltration. Therefore, hemodynamic changes occur relatively earlier in NAFLD than in CH-C. Patients with NASH should be monitored carefully for portal hypertensive complications in the early fibrosis stage.


  • Measurement of blood flow and xenon solubility coefficient in the human liver by xenon‐enhanced computed tomography

    by Shigeru Sase, Hideaki Takahashi, Ryuta Shigefuku, Hiroki Ikeda, Minoru Kobayashi, Nobuyuki Matsumoto, Michihiro Suzuki

    Purpose: The goal of this work was to develop a method of calculating blood flow and xenon solubility coefficient (λ) in the hepatic tissue by xenon‐enhanced computed tomography (Xe‐CT) and to demonstrateλcan be used as a measure of fat content in the human liver.Methods: A new blood supply model is introduced which incorporates both arterial blood and portal venous blood which join and together flow into hepatic tissue. We applied Fickˈs law to the model. It was theoretically derived that the time course of xenon concentration in the inflow blood (the mixture of the arterial blood and the portal venous blood) can be approximated by a monoexponential function. This approximation made it possible to obtain the time‐course change rate (KI) of xenon concentration in the inflow blood using the time course of xenon concentration in the hepatic tissue by applying the algorithm we had reported previously.KIwas used to calculate blood flow andλfor each pixel in the CT image of the liver. Twenty‐six patients (49.2 ± 18.3 years) with nonalcoholic steatohepatitis underwent Xe‐CT abdominal studies and liver biopsies. Steatosis of the liver was evaluated using the biopsy specimen and its severity was divided into ten grades according to the fat deposition percentage [(severity 1) ⩽ 10%, 10 % <(severity 2) ⩽ 20%, …, 90% < (severity 10) ⩽ 100%]. For each patient, blood flow andλmaps of the liver were created, and the averageλvalue () was compared with steatosis severity and with the CT value ratio of the liver to the spleen (liver/spleen ratio).Results: There were good correlations betweenand steatosis severity (r = 0.914,P< 0.0001), and betweenand liver/spleen ratio (r = −0.881,P< 0.0001). Ostwald solubility for xenon in the hepatic tissue (tissue Xe solubility), which is calculated usingand the hematocrit value of the patient, also showed a good correlation with steatosis severity (r = 0.910,P< 0.0001).ranged from 0.86 to 7.81, and tissue Xe solubility ranged from 0.12 to 1.16. This range of solubility is reasonable considering the reported Ostwald solubility coefficients for xenon in the normal liver and in the fat tissue are 0.10 and 1.3, respectively, at 37 °C. The average blood flow value ranged from 15.3 to 53.5 ml/100 ml tissue/min.Conclusions: A method of calculating blood flow andλin the hepatic tissue was developed by means of Xe‐CT. This method would be valid even if portosystemic shunts exist; it is shown thatλmaps can be used to deduce fat content in the liver. As a noninvasive modality, Xe‐CT would be applicable to the quantitative study of fatty change in the human liver.


  • Subtraction lung image for evaluating pulmonary ventilation in xenon‐enhanced CT

    by Shigeru Sase, Hideharu Nakano, Hiroshi Suzuki, Mitsuru Honda

    Purpose: The goal of this work was to develop a method of transforming a xenon‐enhanced CT (Xe‐CT) image of the lung, so as to overlap well with its baseline CT image, and creating a subtraction image (enhanced image minus baseline image), and to demonstrate the possibility of evaluating pulmonary ventilation using the subtraction image.Methods: Eight healthy menunderwent Xe‐CT lung studies. In protocol 1 for five subjects, 30% nonradioactive xenon (Xe) was inhaled for 2 min (washin) followed by air breathing for 4 min (washout). In protocol 2 for three subjects, only washin (30% Xe) for 2 min was applied. In each study, a specific range of the thorax (30 mm) in the supine position was scanned craniocaudally three times in the helical mode: At the start and end of washin and at the end of washout in protocol 1 and at 1 min intervals from the start to end of washin in protocol 2. After each study, 10‐mm‐thick CT images were reconstructed to have similar anatomical structures throughout the study. Two‐dimensional geometrical warping was performed on enhanced CT images so that they could geometrically overlap with the baseline CT image. Second to eighth degree polynomials were applied to the warping functions.Results: It was derived from the Kety model that subtraction images during washin would directly reflect pulmonary ventilation. Geometrical warping achieved an increase of 0.3%–22.0% in the area, for which ventilation could be evaluated in the subtraction image. In the cases in protocol 2 where the initial lung volume was well retained throughout the study, the ratios of the specific ventilation from the subtraction image to that from the specific ventilation map wereandfor the right and left lungs, respectively.Conclusions: A subtraction lung image during washin would provide quantitative information on pulmonary ventilation when the baseline and enhanced images could have close lung volume and these two images could overlap well. Image subtraction requires only two scans and therefore less radiation exposure compared to ordinary protocols in Xe‐CT. The proposed Xe‐CT subtraction method with the geometrical warping technique could be clinically utilized for evaluating pulmonary ventilation.


  • Determination of time‐course change rate for arterial xenon using the time course of tissue xenon concentration in xenon‐enhanced computed tomography

    by Shigeru Sase, Hideaki Takahashi, Hiroki Ikeda, Minoru Kobayashi, Nobuyuki Matsumoto, Michihiro Suzuki

    In calculating tissue blood flow (TBF) according to the Fick principle, time-course information on arterial tracer concentration is indispensable and has a considerable influence on the accuracy of calculated TBF. In TBF measurement by xenon-enhanced computed tomography (Xe-CT), nonradioactive xenon gas is administered by inhalation as a tracer, and end-tidal xenon is used as a substitute for arterial xenon. There has been the assumption that the time-course change rate for end-tidal xenon concentration (Ke) and that for arterial xenon concentration (Ka) are substantially equal. Respiratory gas sampling is noninvasive to the patient and Ke can be easily measured by exponential curve fitting to end-tidal xenon concentrations. However, it is pointed out that there would be a large difference between Ke and Ka in many cases. The purpose of this work was to develop a method of determining the Ka value using the time course of tissue xenon concentration in Xe-CT. The authors incorporated Ka into the Kety autoradiographic equation as a parameter to be solved, and developed a method of least-squares to obtain the solution for Ka from the time-course changes in xenon concentration in the tissue. The authors applied this method of least-squares to the data from Xe-CT abdominal studies performed on 17 patients; the solution for Ka was found pixel by pixel in the spleen, and its Ka map was created for each patient. On the one hand, the authors obtained the average value of the Ka map of the spleen as the calculated Ka (Ka(calc)) for each patient. On the other hand, the authors measured Ka (Ka(meas)) using the time-course changes in CT enhancement in the abdominal aorta for each patient. There was a good correlation between Ka(calc), and Ka(meas) (r = 0.966, P < 0.0001), and these two Ka values were close to each other (Ka(calc) = 0.935 x Ka(meas) + 0.089). This demonstrates that K(cala) would be close to the true Ka value. Accuracy of TBF by Xe-CT can be improved with use of the average value of the Ka map of an organ like the spleen that has a single blood supply (only arterial inflow).


  • Comparison of Cerebral Blood Flow Between Perfusion Computed Tomography and Xenon-Enhanced Computed Tomography for Normal Subjects

    by Shigeru Sase, Mitsuru Honda, Keiichi Machida, Yoshikatsu Seiki

    The purpose of this study was to clarify the difference between cerebral blood flow (CBF) by perfusion computed tomography (CT) and that by xenon-enhanced CT (Xe-CT) through simultaneous measurement. Xenon-enhanced CT and perfusion CT were continually performed on 7 normal subjects. Ratios of CBF by perfusion CT (P-CBF) to CBF by Xe-CT (Xe-CBF) were measured for 5 arterial territories; 3 were territories of 3 major arteries (the anterior [ACA], middle [MCA], and posterior [PCA] cerebral arteries), and the other 2 were areas of the thalamus and putamen. The ratios were 1.30 +/- 0.10, 1.26 +/- 0.15, 1.61 +/- 0.15, 0.801 +/- 0.087, and 0.798 +/- 0.080 for the ACA, MCA, PCA, thalamus, and putamen, respectively. Although a good correlation was observed between P-CBF and Xe-CBF for each territory, the ratios were significantly different (P < 0.0001) between 3 territory groups (group 1: ACA and MCA, group 2: PCA, and group 3: thalamus and putamen). The difference in the ratio of P-CBF to Xe-CBF between the 3 territory groups was considered to result principally from the features of P-CBF. To evaluate P-CBF properly, its territorial characteristics should be taken into account.


  • Quantitative Multilevel Mapping of Hepatic Blood Flow by Xenon Computed Tomography Using Aorta

    by Shigeru Sase, Michihiro Suzuki, Hiroki Ikeda, Hideaki Takahashi, Noriaki Okuse, Shiro Maeyama, Iekado Shibata

    A noninvasive and quantitative technique has been developed to measure human hepatic blood flow by xenon computed tomography (Xe-CT). Accurate data on time-dependent xenon concentrations in the arterial blood are indispensable for Xe-CT to ensure quantitativeness of measured blood flow. A method has been established by our group to use both aorta and end-tidal data to obtain arterial xenon information. Multilevel (3 levels) maps of arterial blood flow (Fa), portal blood flow (Fp), and partition coefficient (λ) were created for patients with chronic hepatitis. A method to objectively evaluate Fa, Fp, and λ values for the whole liver has also been developed by our group.


  • Quantitative Cerebral Blood Flow Calculation Method Using White Matter Lambda in Xenon CT

    by Shigeru Sase, Mitsuru Honda, Tsuyoshi Kushida, Yoshikatsu Seiki, Keiichi Machida, Iekado Shibata

    The objective of this work is to propose a quantitative cerebral blood flow (CBF) calculation method for xenon CT (Xe-CT) by logically estimating the time course change rate (rate constant) of the arterial xenon concentration from that of end-tidal xenon concentration. A single factor, gamma (γ), which is considered to reflect the diffusing capacity of the lung for xenon, was introduced to correlate the end-tidal rate constant (K end-tidal) with the arterial rate constant (K arterial). When an appropriate value is given to γ, it is possible to calculate the arterial rate constant (calculated K arterial) from K end-tidal. A procedure was developed to determine the γ value utilizing the characteristics of white matter lambda (λ). This procedure was applied to three healthy volunteers. The γ γalues for the three subjects were consistent with those directly calculated from end-tidal and arterial (abdominal aorta) xenon data. Hemispheric CBF values with use of calculated K arterial (47.3 ± 10.3 ml/100 g/min) were close to the reported normative values. We conclude this method could make current Xe-CT examinations substantially reliable and quantitative in measuring CBF.