  • Estimation of Skin Blood Flow Artefacts in NIRS Signals During a Verbal Fluency Task

    by Akitoshi Seiyama, Kotona Higaki, Nao Takeuchi, Masahiro Uehara, Naoko Takayama

    The aim of this study was to clarify effects of skin (scalp) blood flow on functional near infrared spectroscopy (fNIRS) during a verbal fluency task. In the present study, to estimate the influence of skin blood flow on fNIRS signals, we conducted examinations on 19 healthy volunteers (39.9 ± 13.1 years, 11 male and 8 female subjects). We simultaneously measured the fNIRS signals, skin blood flow (i.e., flow, velocity, and number of red blood cells [RBC]), and pulse wave rates using a multimodal fNIRS system. We found that the effects of skin blood flow, measured by the degree of interference of the flow, velocity, and number of RBCs, and pulse wave rates, on NIRS signals varied considerably across subjects. Further, by using the above physiological parameters, we evaluated application of the independent component analysis algorithm proposed by Molgedey and Schuster (MS-ICA) to remove skin blood flow artefacts from fNIRS signals.


  • Regional brain temperature changes caused by an increase in neuronal activity irritated by somatosensory stimulation

    by Chizuko Inui, Tsuyoshi Shimura, Tadashi Inui, Akitoshi Seiyama, Yasutomo Iwai, Yoshichika Yoshioka, Ohzawa Izumi

  • Open Access

    Preparation and Characterization of Highly Fluorescent, Glutathione-coated Near Infrared Quantum Dots for in Vivo Fluorescence Imaging

    by Takashi Jin, Fumihiko Fujii, Yutaka Komai, Junji Seki, Akitoshi Seiyama, Yoshichika Yoshioka

    Fluorescent probes that emit in the near-infrared (NIR, 700-1,300 nm) region are suitable as optical contrast agents for in vivo fluorescence imaging because of low scattering and absorption of the NIR light in tissues. Recently, NIR quantum dots (QDs) have become a new class of fluorescent materials that can be used for in vivo imaging. Compared with traditional organic fluorescent dyes, QDs have several unique advantages such as size- and composition-tunable emission, high brightness, narrow emission bands, large Stokes shifts, and high resistance to photobleaching. In this paper, we report a facile method for the preparation of highly fluorescent, water-soluble glutathione (GSH)-coated NIR QDs for in vivo imaging. GSH-coated NIR QDs (GSH-QDs) were prepared by surface modification of hydrophobic CdSeTe/CdS (core/shell) QDs. The hydrophobic surface of the CdSeTe/CdS QDs was exchanged with GSH in tetrahydrofuran-water. The resulting GSH-QDs were monodisperse particles and stable in PBS (phosphate buffered saline, pH = 7.4). The GSH-QDs (800 nm emission) were highly fluorescent in aqueous solutions (quantum yield = 22% in PBS buffer), and their hydrodynamic diameter was less than 10 nm, which is comparable to the size of proteins. The cellular uptake and viability for the GSH-QDs were examined using HeLa and HEK 293 cells. When the cells were incubated with aqueous solutions of the GSH-QDs (10 nM), the QDs were taken into the cells and distributed in the perinuclear region of both cells. After 12 hrs incubation of 4 nM of GSH-QDs, the viabilities of HeLa and HEK 293 cells were ca. 80 and 50%, respectively. As a biomedical utility of the GSH-QDs, in vivo NIRfluorescence imaging of a lymph node in a mouse is presented.


    • 1 January 2004
      • Vol. 31  (1) , 31-40

    In vivo imaging of the rat cerebral microvessels with optical coherence tomography.

    by Yasuhiko Satomura, Junji Seki, Yasuhiro Ooi, Toshio Yanagida, Akitoshi Seiyama

    A technique called optical coherence tomography (OCT) was applied to in vivo observation of microcirculation in the rat cerebral cortex. The OCT system used in this study provided cross-sectional images of the cerebral cortical tissue up to about 1 mm depth with longitudinal resolution up to 8 microm. It could visualize cross-sectional structure of the dura, arachnoid membrane, cortical tissue, and pial microvessels through the cranial window. Pial microvessels with diameter larger than several 10 microm could be detected to observe their cross-sectional shape, while the microvessels within the cortical tissue with smaller diameter were not discernible. The OCT observation revealed that the pial microvessels showed different spatial configurations depending on the cerebral preparations with intact dura and without dura. Stimulus responses of the somatosensory cortices were also different among the preparation methods; Delayed swelling of the cortical surface appeared in the somatosensory cortex following the electrical stimulation of the hind paw in the case of dura removal, which was restricted to a thin surface layer with less than several 10 microm. It is considered to reflect the reactive hyperemia accompanying the neuronal activation. Doppler frequency shift due to the blood flow was detected in pial arterioles. This phenomenon is promising to provide the velocity profile within microvessels and may be applicable to the functional imaging of the brain.