ETEric Thein

Eric Thein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eric Thein has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Olivier Borens

    Service of Orthopaedics and Traumatology, Lausanne University Hospital, Avenue Pierre-Decker 4, 1011 Lausanne Switzerland

    4 shared publications
  • François Chevalley

    2 shared publications
  • Alexandre Burn

    Department of Orthopaedics and Traumatology, Lausanne University Hospital, Lausanne, Switzerland

    1 shared publication
  • Alexandre De Cannière

    Department of Orthopaedics and Traumatology, Lausanne University Hospital, Lausanne, Switzerland

    1 shared publication
  • Andrej Trampuz

    Center for Musculoskeletal Surgery, Charite’—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, 10117 Berlin, Germany

    1 shared publication
  • Bertrand Betrisey

    Service of Infectious Diseases, Lausanne University Hospital, Rue du Bugnon 46, CH-1011 Lausanne, Switzerland

    1 shared publication

Latest Publications

  • Results of open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable pelvic ring injuries: retrospective study of 36 patients

    by Sami Abou-Khalil, Sylvain Steinmetz, Laurent Mustaki, Bertrand Leger, Eric Thein, Olivier Borens

    Introduction Surgical stabilization of posterior pelvic ring fractures can be achieved by closed reduction and percutaneous fixation (CRPF) or by open reduction and internal fixation (ORIF). The aim of the present study is to compare the clinical results of both methods. Material and methods Medical records of 36 patients consecutively operated for unstable pelvic ring injuries were retrospectively reviewed. We compared 22 patients treated with CRPF versus 14 patients stabilized by using ORIF between 2007 and 2017. The Majeed and Pohlemann scores were used to evaluate postoperative functional outcomes. Complications like blood loss, infection rate, Neurological injury, the operative time and the length of hospital stay were analyzed. Results The median Majeed pelvic score was 87 points for the CRPF technique compared with 69 points for the ORIF technique. The median Pohlemann score, operative time and length of hospitalization were similar between the two groups. The median blood loss for the CRPF technique was 300 ml compared to 500 ml for the ORIF technique. CRPF and ORIF procedure had each one neurological lesion. There was one case of infection in the ORIF group and none in the CRPF group. No measurements except for the blood loss have reached the significance threshold. Conclusion The CRPF technique shows a clear decrease in blood loss. There was no statistically significant difference in the functional results, infection rate, neurological injury, operative time and hospital stay between both techniques.


    • 17 December 2014
      • Vol. 10  (455) , 2414-9

    [Periprosthetic fractures].

    by Eric Thein, François Chevalley, Olivier Borens

    A periprosthetic fracture is a fracture around or in proximity of a prosthetic implant. As more and more prostheses are implanted, the incidence of periprosthetic fractures also increases. Several risk factors have been outlined, some due to the patient, and some due to the implant itself. Key points in diagnosis are the case history and the imaging, as they allow the distinction between a well-fixed and a loose prosthesis. Correct classification is crucial for the treatment choice, which can be non-operative or consist in an osteosynthesis or in a revision arthroplasty, depending on the patient's general medical condition and the local status.

  • Medial migration of lag screw after gamma nailing

    by Eric Thein, Alexandre De Cannière, Alexandre Burn, Olivier Borens


    • 18 December 2013
      • Vol. 9  (411) , 2390-6

    [Pseudarthrosis of the long bones].

    by Eric Thein, François Chevalley, Olivier Borens

    5 to 10% of all fractures present with a delayed union, whereas 1 to 5% progress to a nonunion, which can be defined as a fracture older than 6 months and lacks any potential to heal without any further intervention. Different fracture and patient related risk factors exist, and the management of a nonunion needs a thorough clinical, radiological and biological workup to classify them in one of the two main categories, the viable nonunions that need essentially more stability, usually by a more rigid fixation, and the non-viable nonunions that need essentially a biological stimulation by decortication and bone grafting. This treatment still remains the first choice with bony healing obtained in 85 to 95% of cases, but it also comes along with certain risks, and some valuable alternatives exist if chosen on the basis of rigid criteria.


  • Open Access

    In Vitro Activity of Gentamicin-Loaded Bioabsorbable Beads against Different Microorganisms

    by Eric Thein, Ulrika Furustrand Tafin, Bertrand Betrisey, Andrej Trampuz, Olivier Borens

    Osteomyelitis is responsible for high treatment costs, long hospital stays, and results in substantial morbidity. Treatment with surgical debridement and antibiotic-impregnated Polymethylmetacrylate (PMMA) beads is the standard of care, providing high local but low serum antibiotic concentrations, thereby avoiding systemic toxicity. However, for several reasons, the beads require surgical removal. Alternative antibiotic delivery systems should improve the treatment of bone infection, actively encourage bone healing and require no additional surgery for removal. We investigated the activity of gentamicin-loaded bioabsorbable beads against different microorganisms (Staphylococcus epidermidis, S. aureus, Escherichia coli, Enterococcus faecalis, Candida albicans) commonly causing surgical site bone infection, by microcalorimetry. Calcium sulphate beads containing gentamicin were incubated in microcalorimetry ampoules containing different concentrations of the corresponding microorganism. Growth medium with each germ and unloaded beads was used as positive control, growth medium with loaded beads alone as negative control. Bacterial growth-related heat production at 37 °C was measured for 24 h. Cultures without gentamicin-loaded beads produced heat-flow peaks corresponding to the exponential growth of the corresponding microorganisms in nutrient-rich medium. In contrast, cultures with gentamicin-loaded beads completely suppressed heat production during 24 h, demonstrating their antibiotic activity. Gentamicin-loaded beads effectively inhibited growth of susceptible microorganisms, under the described in vitro conditions.