Wenguo Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenguo Wu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Shi-Bin Wang
Institute of Biomaterials and Tissue Engineering, Huaqiao University, Xiamen 361021, PR China; Fujian Provincial Key Laboratory of Biochemical Technology (Huaqiao University), Xiamen 361021, PR China
6 shared publications Aizheng Chen
4 shared publications- Yuangang Liu
Institute of Pharmaceutical Engineering, Huaqiao University, Xiamen, China
4 shared publications - Ai-Zheng Chen
Institute of Biomaterials and Tissue Engineering, Huaqiao University, Xiamen, China
3 shared publications - Jia Lin
College of Chemical Engineering, Huaqiao University, Xiamen 361021, China
3 shared publications - Chaoyi Hu
College of Chemical Engineering, Huaqiao University, Xiamen 361021, China
2 shared publications
Latest Publications
- Open Access
- 11 December 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (12) , 606
Antimicrobial Responses to Bacterial Metabolic Activity and Biofilm Formation Studied Using Microbial Fuel Cell-Based Biosensors
Simultaneous monitoring of antimicrobial responses to bacterial metabolic activity and biofilm formation is critical for efficient screening of new anti-biofilm drugs. A microbial fuel cell-based biosensor using Pseudomonas aeruginosa as an electricigen was constructed. The effects of silver nanoparticles (AgNPs) on the cellular metabolic activity and biofilm formation of P. aeruginosa in the biosensors were investigated and compared with the traditional biofilm detection method. The crystal violet staining results showed that the concentration of AgNPs being increased to 20 and 40 μg/mL had a slight and obvious inhibitory effect on biofilm formation, respectively. In comparison, the detection sensitivity of the biosensor was much higher. When the concentration of AgNPs was 5 μg/mL, the output voltage of the biosensor was suppressed, and the inhibition gradually increased with the AgNPs dose. AgNPs inhibited the activity of planktonic cells in the anolyte and the formation of biofilm on the anode surface, and it had a dose-dependent effect on the secretion of phenazine in the anolyte. The biosensor could monitor the impacts of AgNPs not only on biofilm formation but also on cell activity and metabolic activity. It provides a new and sensitive method for the screening of anti-biofilm drugs.
- 11 December 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (12) , 606
Open AccessAntimicrobial Responses to Bacterial Metabolic Activity and Biofilm Formation Studied Using Microbial Fuel Cell-Based Biosensors
Simultaneous monitoring of antimicrobial responses to bacterial metabolic activity and biofilm formation is critical for efficient screening of new anti-biofilm drugs. A microbial fuel cell-based biosensor using Pseudomonas aeruginosa as an electricigen was constructed. The effects of silver nanoparticles (AgNPs) on the cellular metabolic activity and biofilm formation of P. aeruginosa in the biosensors were investigated and compared with the traditional biofilm detection method. The crystal violet staining results showed that the concentration of AgNPs being increased to 20 and 40 μg/mL had a slight and obvious inhibitory effect on biofilm formation, respectively. In comparison, the detection sensitivity of the biosensor was much higher. When the concentration of AgNPs was 5 μg/mL, the output voltage of the biosensor was suppressed, and the inhibition gradually increased with the AgNPs dose. AgNPs inhibited the activity of planktonic cells in the anolyte and the formation of biofilm on the anode surface, and it had a dose-dependent effect on the secretion of phenazine in the anolyte. The biosensor could monitor the impacts of AgNPs not only on biofilm formation but also on cell activity and metabolic activity. It provides a new and sensitive method for the screening of anti-biofilm drugs.
- Open Access
- 6 August 2024
- Published by Science China Press., Co. Ltd. in Chinese Science Bulletin
- Vol. 69 (28-29) , 4281-4298
Recent advances in novel functionalized oral administration therapy for inflammatory bowel diseases
近年来炎症性肠病(inflammatory bowel disease, IBD)在全球的发病率迅速上升,IBD疾病负担日益严峻,成为人类社会面临的重大挑战。IBD是一种慢性易复发炎症性肠道疾病,并累及全身器官和组织,严重降低患者生存质量。IBD的发病机制尚不明确,可能与免疫、遗传、环境和微生物之间的相互作用有关。由于口服给药对患者依从性好、安全性高、方便、易于操作且能直接作用于肠粘膜,适用于慢性肠道疾病长期给药,是IBD治疗的最理想给药途径。然而口服药物存在水溶性差、治疗功能单一和严重的全身副作用等问题,且口服给药受到胃肠道生理环境障碍的影响,导致生物利用度低,治疗效果不佳。针对上述问题,本文分别从聚合物药物递送系统、纳米酶制剂、仿生药物递送系统、工程益生菌递送系统以及诊断和治疗一体化系统等方面进行综述,总结了IBD的新型功能化口服给药治疗方法,能够有效地提高药物的溶解度和生物利用度,并且实现结肠炎症靶向和多功能诊疗,为IBD的精准治疗提供新思路和新途径。
- 6 August 2024
- Published by Science China Press., Co. Ltd. in Chinese Science Bulletin
- Vol. 69 (28-29) , 4281-4298
Open AccessRecent advances in novel functionalized oral administration therapy for inflammatory bowel diseases
近年来炎症性肠病(inflammatory bowel disease, IBD)在全球的发病率迅速上升,IBD疾病负担日益严峻,成为人类社会面临的重大挑战。IBD是一种慢性易复发炎症性肠道疾病,并累及全身器官和组织,严重降低患者生存质量。IBD的发病机制尚不明确,可能与免疫、遗传、环境和微生物之间的相互作用有关。由于口服给药对患者依从性好、安全性高、方便、易于操作且能直接作用于肠粘膜,适用于慢性肠道疾病长期给药,是IBD治疗的最理想给药途径。然而口服药物存在水溶性差、治疗功能单一和严重的全身副作用等问题,且口服给药受到胃肠道生理环境障碍的影响,导致生物利用度低,治疗效果不佳。针对上述问题,本文分别从聚合物药物递送系统、纳米酶制剂、仿生药物递送系统、工程益生菌递送系统以及诊断和治疗一体化系统等方面进行综述,总结了IBD的新型功能化口服给药治疗方法,能够有效地提高药物的溶解度和生物利用度,并且实现结肠炎症靶向和多功能诊疗,为IBD的精准治疗提供新思路和新途径。
- 1 December 2020
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 196, 111286
Synergistic antitumor efficacy of doxorubicin and gambogic acid-encapsulated albumin nanocomposites
- 1 December 2020
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 196, 111286
Synergistic antitumor efficacy of doxorubicin and gambogic acid-encapsulated albumin nanocomposites
- Open Access
Controlled Layer-By-Layer Deposition of Carbon Nanotubes on Electrodes for Microbial Fuel Cells
Carbon nanotubes (CNTs) and polyelectrolyte poly(allylamine hydrochloride) (PAH) composite modified indium tin oxide (ITO) electrodes, by a layer-by-layer (LBL) self-assembly technique, was evaluated as an anode for microbial fuel cells (MFCs). The bioelectrochemistry of Shewanella loihica PV-4 in an electrochemical cell and the electricity generation performance of MFCs with multilayer (CNTs/PAH)n-deposited ITO electrodes as an anode were investigated. Experimental results showed that the current density generated on the multilayer modified electrode increased initially and then decreased as the deposition of the number of layers (n = 12) increased. Chronoamperometric results showed that the highest peak current density of 34.85 ± 2.80 mA/m2 was generated on the multilayer (CNTs/PAH)9-deposited ITO electrode, of which the redox peak current of cyclic voltammetry was also significantly enhanced. Electrochemical impedance spectroscopy analyses showed a well-formed nanostructure porous film on the surface of the multilayer modified electrode. Compared with the plain ITO electrode, the multilayered (CNTs/PAH)9 anodic modification improved the power density of the dual-compartment MFC by 29%, due to the appropriate proportion of CNTs and PAH, as well as the porous nanostructure on the electrodes.
Open AccessControlled Layer-By-Layer Deposition of Carbon Nanotubes on Electrodes for Microbial Fuel Cells
Carbon nanotubes (CNTs) and polyelectrolyte poly(allylamine hydrochloride) (PAH) composite modified indium tin oxide (ITO) electrodes, by a layer-by-layer (LBL) self-assembly technique, was evaluated as an anode for microbial fuel cells (MFCs). The bioelectrochemistry of Shewanella loihica PV-4 in an electrochemical cell and the electricity generation performance of MFCs with multilayer (CNTs/PAH)n-deposited ITO electrodes as an anode were investigated. Experimental results showed that the current density generated on the multilayer modified electrode increased initially and then decreased as the deposition of the number of layers (n = 12) increased. Chronoamperometric results showed that the highest peak current density of 34.85 ± 2.80 mA/m2 was generated on the multilayer (CNTs/PAH)9-deposited ITO electrode, of which the redox peak current of cyclic voltammetry was also significantly enhanced. Electrochemical impedance spectroscopy analyses showed a well-formed nanostructure porous film on the surface of the multilayer modified electrode. Compared with the plain ITO electrode, the multilayered (CNTs/PAH)9 anodic modification improved the power density of the dual-compartment MFC by 29%, due to the appropriate proportion of CNTs and PAH, as well as the porous nanostructure on the electrodes.
- Open Access
Polyaniline/Carbon Nanotubes Composite Modified Anode via Graft Polymerization and Self-Assembling for Microbial Fuel Cells
Microbial fuel cells (MFCs) are promising devices for sustainable energy production, wastewater treatment and biosensors. Anode materials directly interact with electricigens and accept electrons between cells, playing an important role in determining the performance of MFCs. In this study, a novel carbon nanotubes (CNTs) and polyaniline (PANI) nanocomposite film modified Indium-tin oxide (ITO) anode was fabricated through graft polymerization of PANI after the modification of γ-aminopropyltriethoxysilane (APTES) on ITO substrate, which was followed by layer-by-layer (LBL) self-assembling of CNTs and PANI alternatively on its surface. (CNTs/PANI)n/APTES/ITO electrode with low charge transfer resistance showed better electrochemical behavior compared to the bare ITO electrode. Twelve layers of CNTs/PANI decorated ITO electrode with an optimal nanoporous network exhibited superior biocatalytic properties with a maximal current density of 6.98 µA/cm2, which is 26-fold higher than that of conventional ITO electrode in Shewanella loihica PV-4 bioelectrochemical system. MFCs with (CNTs/PANI)12/APTES/ITO as the anode harvested a maximum output power density of 34.51 mW/m2, which is 7.5-fold higher than that of the unmodified ITO electrode. These results demonstrate that (CNTs/PANI)12/APTES/ITO electrode has superior electrochemical and electrocatalytic properties compared to the bare ITO electrode, while the cellular toxicity of CNTs has an effect on the performance of MFC with (CNTs/PANI)n/APTES/ITO electrode.
Open AccessPolyaniline/Carbon Nanotubes Composite Modified Anode via Graft Polymerization and Self-Assembling for Microbial Fuel Cells
Microbial fuel cells (MFCs) are promising devices for sustainable energy production, wastewater treatment and biosensors. Anode materials directly interact with electricigens and accept electrons between cells, playing an important role in determining the performance of MFCs. In this study, a novel carbon nanotubes (CNTs) and polyaniline (PANI) nanocomposite film modified Indium-tin oxide (ITO) anode was fabricated through graft polymerization of PANI after the modification of γ-aminopropyltriethoxysilane (APTES) on ITO substrate, which was followed by layer-by-layer (LBL) self-assembling of CNTs and PANI alternatively on its surface. (CNTs/PANI)n/APTES/ITO electrode with low charge transfer resistance showed better electrochemical behavior compared to the bare ITO electrode. Twelve layers of CNTs/PANI decorated ITO electrode with an optimal nanoporous network exhibited superior biocatalytic properties with a maximal current density of 6.98 µA/cm2, which is 26-fold higher than that of conventional ITO electrode in Shewanella loihica PV-4 bioelectrochemical system. MFCs with (CNTs/PANI)12/APTES/ITO as the anode harvested a maximum output power density of 34.51 mW/m2, which is 7.5-fold higher than that of the unmodified ITO electrode. These results demonstrate that (CNTs/PANI)12/APTES/ITO electrode has superior electrochemical and electrocatalytic properties compared to the bare ITO electrode, while the cellular toxicity of CNTs has an effect on the performance of MFC with (CNTs/PANI)n/APTES/ITO electrode.
- 1 March 2016
- Vol. 32 (3) , 271-83
[Progress in nanomaterials modified anodes of microbial fuel cell].
Anode is an important part of microbial fuel cell, its performance significantly affects the electricity generation of microbial fuel cells (MFCs). Nanomaterials have excellent properties, such as good conductivity and large surface area. Therefore, nanomaterials modified anode can effectively reduce the electrode resistance, increase the amount of microbial adhesion and improve the electricity generation of MFCs. In this paper, we introduced various nanomaterials modified anodes and summarized their effects on the output performance of MFCs. Finally, the prospect of modifying nanomaterials and technologies were discussed.
- 1 March 2016
- Vol. 32 (3) , 271-83
[Progress in nanomaterials modified anodes of microbial fuel cell].
Anode is an important part of microbial fuel cell, its performance significantly affects the electricity generation of microbial fuel cells (MFCs). Nanomaterials have excellent properties, such as good conductivity and large surface area. Therefore, nanomaterials modified anode can effectively reduce the electrode resistance, increase the amount of microbial adhesion and improve the electricity generation of MFCs. In this paper, we introduced various nanomaterials modified anodes and summarized their effects on the output performance of MFCs. Finally, the prospect of modifying nanomaterials and technologies were discussed.
- 1 November 2015
- Published by American Scientific Publishers in Science of Advanced Materials
- Vol. 7 (11) , 2380-2387
Preparation of SF/PLGA Scaffold with Microporous-Nano/Microfibrous Architecture by Thermal Induced Phase Separation
Normally a useful tissue engineering scaffold should provide suitable micropores and fibrous structure to mimic the natural extracellular matrix (ECM), which can induce desired cellular activities and guide tissue regeneration. In this work, a microporous and micro/nanofibrous silk fibroin-poly(lactic-co-glycolic acid) (SF-PLGA) scaffold prepared by thermal induced phase separation (TIPS) was described. Minitab statistical software was used to analyze the TIPS parameters effect on the pore size, porosity and fibre diameter. Results showed that the ECM-like architecture could be achieved by TIPS with the mean porosity 81 ± 16% and the pore size among 0.0–66.7 μm. Besides, cell viability tests revealed that the cells could proliferate on the SF/PLGA scaffolds. These results reveal that the SF-PLGA scaffolds prepared by TIPS are suitable for the future tissue engineering applications.
- 1 November 2015
- Published by American Scientific Publishers in Science of Advanced Materials
- Vol. 7 (11) , 2380-2387
Preparation of SF/PLGA Scaffold with Microporous-Nano/Microfibrous Architecture by Thermal Induced Phase Separation
Normally a useful tissue engineering scaffold should provide suitable micropores and fibrous structure to mimic the natural extracellular matrix (ECM), which can induce desired cellular activities and guide tissue regeneration. In this work, a microporous and micro/nanofibrous silk fibroin-poly(lactic-co-glycolic acid) (SF-PLGA) scaffold prepared by thermal induced phase separation (TIPS) was described. Minitab statistical software was used to analyze the TIPS parameters effect on the pore size, porosity and fibre diameter. Results showed that the ECM-like architecture could be achieved by TIPS with the mean porosity 81 ± 16% and the pore size among 0.0–66.7 μm. Besides, cell viability tests revealed that the cells could proliferate on the SF/PLGA scaffolds. These results reveal that the SF-PLGA scaffolds prepared by TIPS are suitable for the future tissue engineering applications.
- 31 March 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 3 (17) , 3420-3424
Preparation of ALG-g-Lys and its application as a novel drug carrier
In order to improve alginate microbead stability and further broaden the application of alginate in biomaterials, a new biomaterial, ALG-g-Lys, was prepared and its possibility as a novel drug carrier investigated.
- 31 March 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 3 (17) , 3420-3424
Preparation of ALG-g-Lys and its application as a novel drug carrier
In order to improve alginate microbead stability and further broaden the application of alginate in biomaterials, a new biomaterial, ALG-g-Lys, was prepared and its possibility as a novel drug carrier investigated.
- 1 April 2014
- Published by American Scientific Publishers in Journal of Bionanoscience
- Vol. 8 (2) , 127-132
Paclitaxel-Alginate/Chitosan Microcapsules Prepared Using High-Voltage Electrostatic Technique
In present study, a coated matrix type of paclitaxel-alginate/chitosan microcapsule was successfully prepared using the high-voltage electrostatic technique as a novel formulation for drug delivery. The surface morphology and structure of the obtained paclitaxel-alginate microspheres were analyzed by optical microscopy, Fourier transform infrared spectroscopy and differential scanning calorimetry. The effect of paclitaxel concentration on drug loading of paclitaxel-alginate/chitosan microcapsules, and the effect of chitosan concentration and chitosan molecular weight on encapsulation efficiency were investigated. Experimental results showed that paclitaxel in an amorphous was heterogeneously entrapped in sodium alginate matrix and combined with it through electrostatic interactions between them. When paclitaxel concentration was 5, 15 and 25 mg in 1.5 mL of sodium alginate, the drug loading of the microcapsules was 7.11, 37.09 and 45.67%, respectively. As chitosan concentration was increased from 0.1% to 0.5%, the encapsulation efficiency was decreased from 87.91% to 36.44%. As the molecular weight of chitosan was increased from 50,000 Da to 150,000 Da, the encapsulation efficiency was firstly decreased from 96.37% to 83.53%, and then increased to 98.50%.
- 1 April 2014
- Published by American Scientific Publishers in Journal of Bionanoscience
- Vol. 8 (2) , 127-132
Paclitaxel-Alginate/Chitosan Microcapsules Prepared Using High-Voltage Electrostatic Technique
In present study, a coated matrix type of paclitaxel-alginate/chitosan microcapsule was successfully prepared using the high-voltage electrostatic technique as a novel formulation for drug delivery. The surface morphology and structure of the obtained paclitaxel-alginate microspheres were analyzed by optical microscopy, Fourier transform infrared spectroscopy and differential scanning calorimetry. The effect of paclitaxel concentration on drug loading of paclitaxel-alginate/chitosan microcapsules, and the effect of chitosan concentration and chitosan molecular weight on encapsulation efficiency were investigated. Experimental results showed that paclitaxel in an amorphous was heterogeneously entrapped in sodium alginate matrix and combined with it through electrostatic interactions between them. When paclitaxel concentration was 5, 15 and 25 mg in 1.5 mL of sodium alginate, the drug loading of the microcapsules was 7.11, 37.09 and 45.67%, respectively. As chitosan concentration was increased from 0.1% to 0.5%, the encapsulation efficiency was decreased from 87.91% to 36.44%. As the molecular weight of chitosan was increased from 50,000 Da to 150,000 Da, the encapsulation efficiency was firstly decreased from 96.37% to 83.53%, and then increased to 98.50%.
- Open Access
Preparation of Chitosan-Based Hemostatic Sponges by Supercritical Fluid Technology
Using ammonium bicarbonate (AB) particles as a porogen, chitosan (CS)-based hemostatic porous sponges were prepared in supercritical carbon dioxide due to its low viscosity, small surface tension, and good compatibility with organic solvent. Fourier transform infrared spectroscopy (FTIR) spectra demonstrated that the chemical compositions of CS and poly-(methyl vinyl ether-co-maleic anhydride) (PVM/MA) were not altered during the phase inversion process. The morphology and structure of the sponge after the supercritical fluid (SCF) process were observed by scanning electron microscopy (SEM). The resulting hemostatic sponges showed a relatively high porosity (about 80%) with a controllable pore size ranging from 0.1 to 200 µm. The concentration of PVM/MA had no significant influence on the porosity of the sponges. Comparative experiments on biological assessment and hemostatic effect between the resulting sponges and Avitene® were also carried out. With the incorporation of PVM/MA into the CS-based sponges, the water absorption rate of the sponges increased significantly, and the CS-PVM/MA sponges showed a similar water absorption rate (about 90%) to that of Avitene®. The results of the whole blood clotting experiment and animal experiment also demonstrated that the clotting ability of the CS-PVM/MA sponges was similar to that of Avitene®. All these results elementarily verified that the sponges prepared in this study were suitable for hemostasis and demonstrated the feasibility of using SCF-assisted phase inversion technology to produce hemostatic porous sponges.
Open AccessPreparation of Chitosan-Based Hemostatic Sponges by Supercritical Fluid Technology
Using ammonium bicarbonate (AB) particles as a porogen, chitosan (CS)-based hemostatic porous sponges were prepared in supercritical carbon dioxide due to its low viscosity, small surface tension, and good compatibility with organic solvent. Fourier transform infrared spectroscopy (FTIR) spectra demonstrated that the chemical compositions of CS and poly-(methyl vinyl ether-co-maleic anhydride) (PVM/MA) were not altered during the phase inversion process. The morphology and structure of the sponge after the supercritical fluid (SCF) process were observed by scanning electron microscopy (SEM). The resulting hemostatic sponges showed a relatively high porosity (about 80%) with a controllable pore size ranging from 0.1 to 200 µm. The concentration of PVM/MA had no significant influence on the porosity of the sponges. Comparative experiments on biological assessment and hemostatic effect between the resulting sponges and Avitene® were also carried out. With the incorporation of PVM/MA into the CS-based sponges, the water absorption rate of the sponges increased significantly, and the CS-PVM/MA sponges showed a similar water absorption rate (about 90%) to that of Avitene®. The results of the whole blood clotting experiment and animal experiment also demonstrated that the clotting ability of the CS-PVM/MA sponges was similar to that of Avitene®. All these results elementarily verified that the sponges prepared in this study were suitable for hemostasis and demonstrated the feasibility of using SCF-assisted phase inversion technology to produce hemostatic porous sponges.