Kate Grudpan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kate Grudpan has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Kanokwan Kiwfo
Center of Excellence for Innovation in Analytical Science and Technology for Biodiversity-based Economic and Society (I-ANALY-S-T_B.BES-CMU), Chiang Mai University, Chiang Mai 50200, Thailand
10 shared publications - Chalermpong Saenjum
Research Center for Innovation in Analytical Science and Technology for Biodiversity-Based Economic and Society (I-ANALY-S-T_B.BES-CMU), Multidisciplinary Research Institute (MDRI), Chiang Mai University, Chiang Mai 50200, Thailand
8 shared publications - Monnapat Vongboot
Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
6 shared publications - Pathinan Paengnakorn
Biomedical Engineering Institute, Chiang Mai University, Chiang Mai 50200, Thailand
6 shared publications - Chonnipa Yeerum
Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Bangkok 10140, Thailand
5 shared publications - Kraingkrai Ponhong
Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahasarakham University, Maha Sarakham, 44150, Thailand
5 shared publications
Latest Publications
- Open Access
Portable and Rapid Smartphone-Based Colorimetric Assay of Peracetic Acid for Point-of-Use Medical/Pharmaceutical Disinfectant Preparation
A simple and rapid smartphone-based colorimetric assay for peracetic acid concentration was developed to facilitate point-of-use disinfectant preparations for infection prevention and control. The colorimetric detection was based on the oxidation of N,N-diethyl-phenylenediamine by peracetic acid through an intermediate reaction with potassium iodide, resulting in pink-magenta products. The colorimetric reaction was performed on a 96-well plate; then, the color products were photographed in one image. The color intensity was evaluated to determine the peracetic acid concentration using a custom-built mobile application named Modern Peracetic Acid Analysis. The relative green intensity of the pink-magenta products was directly proportional to the peracetic acid concentration in the range of 0.15 to 3.0 µg/mL. The detection and quantitation limits were 0.11 µg/mL and 0.34 µg/mL, respectively. The approach was successfully applied to determine the peracetic acid concentration in pharmaceutical disinfectant formulations. The results obtained using the proposed approach showed no significant differences from those obtained using acid–base titration at the 95% confidence level. The greenness of the proposed approach was evaluated using the Complementary Green Analytical Procedure Index, Analytical Greenness, and Blue Applicability Grade Index, demonstrating enhanced environmental friendliness and practical advantages, as well as simple, portable instrumentation that is easier to operate than traditional spectrophotometric and titration methods. Furthermore, a sustainability assessment based on the Need, Quality, and Sustainability index underscored its enhanced sustainability.
Open AccessPortable and Rapid Smartphone-Based Colorimetric Assay of Peracetic Acid for Point-of-Use Medical/Pharmaceutical Disinfectant Preparation
A simple and rapid smartphone-based colorimetric assay for peracetic acid concentration was developed to facilitate point-of-use disinfectant preparations for infection prevention and control. The colorimetric detection was based on the oxidation of N,N-diethyl-phenylenediamine by peracetic acid through an intermediate reaction with potassium iodide, resulting in pink-magenta products. The colorimetric reaction was performed on a 96-well plate; then, the color products were photographed in one image. The color intensity was evaluated to determine the peracetic acid concentration using a custom-built mobile application named Modern Peracetic Acid Analysis. The relative green intensity of the pink-magenta products was directly proportional to the peracetic acid concentration in the range of 0.15 to 3.0 µg/mL. The detection and quantitation limits were 0.11 µg/mL and 0.34 µg/mL, respectively. The approach was successfully applied to determine the peracetic acid concentration in pharmaceutical disinfectant formulations. The results obtained using the proposed approach showed no significant differences from those obtained using acid–base titration at the 95% confidence level. The greenness of the proposed approach was evaluated using the Complementary Green Analytical Procedure Index, Analytical Greenness, and Blue Applicability Grade Index, demonstrating enhanced environmental friendliness and practical advantages, as well as simple, portable instrumentation that is easier to operate than traditional spectrophotometric and titration methods. Furthermore, a sustainability assessment based on the Need, Quality, and Sustainability index underscored its enhanced sustainability.
- Open Access
- 4 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 451
Smartphone-Based Color Evaluation of Passive Samplers for Gases: A Review
The application of smartphone-based color evaluation of passive sampling devices for gases has only been sparsely reported. The present review aims to compile available publications with respect to the configuration of the passive samplers, conditions of smartphone photographing, analytical procedures for color detection and quantification (including calibration processes), and their application to different target gases. The performance of the methods—whenever available—is presented regarding the analytical specifications selectivity, sensitivity, and limit of detection in comparison with other color evaluation methods of passive samplers. Practical aspects like requirements of instrumentation and ease of use will be outlined in view of the potential employment in education and citizen science projects. In one section of the review, the inconsistent terminology of passive and diffusive sampling is discussed in order to clarify the distinction of information obtained from the uptake of the passive samplers between gas-phase concentration and the accumulated deposition flux of gaseous analytes. Colorimetric gas sensors are included in the review when applied in passive sampling configurations and evaluation is performed with smartphone-based color evaluation. Differences in the analytical procedures employed after the passive sampling step and prior to the detection of the colored compounds are also presented.
- 4 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 451
Open AccessSmartphone-Based Color Evaluation of Passive Samplers for Gases: A Review
The application of smartphone-based color evaluation of passive sampling devices for gases has only been sparsely reported. The present review aims to compile available publications with respect to the configuration of the passive samplers, conditions of smartphone photographing, analytical procedures for color detection and quantification (including calibration processes), and their application to different target gases. The performance of the methods—whenever available—is presented regarding the analytical specifications selectivity, sensitivity, and limit of detection in comparison with other color evaluation methods of passive samplers. Practical aspects like requirements of instrumentation and ease of use will be outlined in view of the potential employment in education and citizen science projects. In one section of the review, the inconsistent terminology of passive and diffusive sampling is discussed in order to clarify the distinction of information obtained from the uptake of the passive samplers between gas-phase concentration and the accumulated deposition flux of gaseous analytes. Colorimetric gas sensors are included in the review when applied in passive sampling configurations and evaluation is performed with smartphone-based color evaluation. Differences in the analytical procedures employed after the passive sampling step and prior to the detection of the colored compounds are also presented.
- Open Access
- 6 March 2024
- Published by MDPI AG in Preprints.org
Smartphone-Based Color Evaluation of Passive Samplers for Gases: A Review
The application of smartphone-based color evaluation of passive sampling devices for gases has only been sparsely reported. The present review aims to compile available publications with respect to the configuration of the passive samplers, conditions of smartphone photographing, analytical procedure for color detection and quantification (including calibration processes), and their application to different target gases. The performance of the methods - whenever available - is presented regarding the analytical specifications selectivity, sensitivity, and limit of detection in comparison with other color evaluation methods of passive samplers. Practical aspects like requirements of instrumentation and ease of use will be outlined in view of the potential employment in education and citizen science projects. In one section of the review the inconsistent terminology of passive and diffusive sampling is discussed in order to clarify the distinction of information obtained from the uptake of the passive samplers between gas-phase concentration and the accumulated deposition flux of gaseous analytes. Colorimetric gas sensors are included in the review when applied in passive sampling configurations and evaluation is performed with smartphone-based color evaluation. Differences in the analytical procedures employed after the passive sampling step and prior to the detection of the colored compounds are also presented.
- 6 March 2024
- Published by MDPI AG in Preprints.org
Open AccessSmartphone-Based Color Evaluation of Passive Samplers for Gases: A Review
The application of smartphone-based color evaluation of passive sampling devices for gases has only been sparsely reported. The present review aims to compile available publications with respect to the configuration of the passive samplers, conditions of smartphone photographing, analytical procedure for color detection and quantification (including calibration processes), and their application to different target gases. The performance of the methods - whenever available - is presented regarding the analytical specifications selectivity, sensitivity, and limit of detection in comparison with other color evaluation methods of passive samplers. Practical aspects like requirements of instrumentation and ease of use will be outlined in view of the potential employment in education and citizen science projects. In one section of the review the inconsistent terminology of passive and diffusive sampling is discussed in order to clarify the distinction of information obtained from the uptake of the passive samplers between gas-phase concentration and the accumulated deposition flux of gaseous analytes. Colorimetric gas sensors are included in the review when applied in passive sampling configurations and evaluation is performed with smartphone-based color evaluation. Differences in the analytical procedures employed after the passive sampling step and prior to the detection of the colored compounds are also presented.
- Top Cited Papers
- 25 June 2023
- Published by Elsevier in Microchemical Journal
- Vol. 193
A new need, quality, and sustainability (NQS) index for evaluating chemical analysis procedures using natural reagents
- 25 June 2023
- Published by Elsevier in Microchemical Journal
- Vol. 193
Top Cited PapersA new need, quality, and sustainability (NQS) index for evaluating chemical analysis procedures using natural reagents
- Open Access
Green Downscaling of Solvent Extractive Determination Employing Coconut Oil as Natural Solvent with Smartphone Colorimetric Detection: Demonstrating the Concept via Cu(II) Assay Using 1,5-Diphenylcarbazide
Coconut oil as a natural solvent is proposed for green downscaling solvent extractive determination. Determination of Cu(II) using 1,5-Diphenylcarbazide (DPC) was selected as a model for the investigation. Cu(II)-DPC complexes in aqueous solution were transferred into coconut oil phase. The change of the color due to Cu(II)-DPC complexes in coconut oil was followed by using a smartphone and image processing. A single standard concept was used for a series of Cu(II) standard solutions. A downscaling procedure using a 2 mL vial provided a calibration: color intensity = −142 [Cu(II)] + 222, (R2 = 0.98), 10% RSD. Using a well plate, a calibration was: color intensity = 61 [Cu(II)] + 68 (R2 = 0.91), 15% RSD. Both were for the range of 0–1 ppm Cu(II). Application of the developed procedure to water samples was demonstrated. The developed procedures provided a new approach of green chemical analysis.
Open AccessGreen Downscaling of Solvent Extractive Determination Employing Coconut Oil as Natural Solvent with Smartphone Colorimetric Detection: Demonstrating the Concept via Cu(II) Assay Using 1,5-Diphenylcarbazide
Coconut oil as a natural solvent is proposed for green downscaling solvent extractive determination. Determination of Cu(II) using 1,5-Diphenylcarbazide (DPC) was selected as a model for the investigation. Cu(II)-DPC complexes in aqueous solution were transferred into coconut oil phase. The change of the color due to Cu(II)-DPC complexes in coconut oil was followed by using a smartphone and image processing. A single standard concept was used for a series of Cu(II) standard solutions. A downscaling procedure using a 2 mL vial provided a calibration: color intensity = −142 [Cu(II)] + 222, (R2 = 0.98), 10% RSD. Using a well plate, a calibration was: color intensity = 61 [Cu(II)] + 68 (R2 = 0.91), 15% RSD. Both were for the range of 0–1 ppm Cu(II). Application of the developed procedure to water samples was demonstrated. The developed procedures provided a new approach of green chemical analysis.
- Open Access
Sequential Injection Amperometric System Coupling with Bioreactor for In-Line Glucose Monitoring in Cell Culture Application
We proposed a specially designed sequential injection (SI) amperometric system coupling with a bioreactor for in-line glucose monitoring in cell culture. The system is composed of three main parts which are the bioreactor, SI system, and electrochemical detection unit. The bioreactor accommodates six individual cell culture units which can be operated separately under different conditions. The SI system enables automatic in-line sampling and in-line sample dilution, with a specially designed mixing unit; therefore, it has the benefits of fast analysis time and less contamination risk. The use of 3D-printed microfluidic components, a mixing channel, and a flow cell helped to reduce operational time and sample volume. A disposable screen-printed electrode (SPE), modified with glucose oxidase (GOD), carbon nanotube, and gold nanoparticle, was used for detection. The developed system provided a linear range up to 3.8 mM glucose in cell culture media. In order to work with cell culture in higher glucose media, the in-line sample dilution can be applied. The developed SI system was demonstrated with mouse fibroblast (L929) cell culture. The results show that glucose concentration obtained from the SI system is comparable with that obtained from the conventional colorimetric method. This work can be further developed and applied for in vitro cell-based experiments in biomedical research.
Open AccessSequential Injection Amperometric System Coupling with Bioreactor for In-Line Glucose Monitoring in Cell Culture Application
We proposed a specially designed sequential injection (SI) amperometric system coupling with a bioreactor for in-line glucose monitoring in cell culture. The system is composed of three main parts which are the bioreactor, SI system, and electrochemical detection unit. The bioreactor accommodates six individual cell culture units which can be operated separately under different conditions. The SI system enables automatic in-line sampling and in-line sample dilution, with a specially designed mixing unit; therefore, it has the benefits of fast analysis time and less contamination risk. The use of 3D-printed microfluidic components, a mixing channel, and a flow cell helped to reduce operational time and sample volume. A disposable screen-printed electrode (SPE), modified with glucose oxidase (GOD), carbon nanotube, and gold nanoparticle, was used for detection. The developed system provided a linear range up to 3.8 mM glucose in cell culture media. In order to work with cell culture in higher glucose media, the in-line sample dilution can be applied. The developed SI system was demonstrated with mouse fibroblast (L929) cell culture. The results show that glucose concentration obtained from the SI system is comparable with that obtained from the conventional colorimetric method. This work can be further developed and applied for in vitro cell-based experiments in biomedical research.
- Open Access
Ultrasound-Assisted One-Pot Cloud Point Extraction for Iron Determination Using Natural Chelating Ligands from Dipterocarpus intricatus Dyer Fruit
An ultrasound-assisted, one-pot cloud point extraction was developed for the determination of iron in vegetable samples by UV-Visible spectrophotometry. This method was based on the complexation of iron with an environmentally-friendly natural chelating agent extracted from Dipterocarpus intricatus Dyer fruit at pH 5.5 in the presence of Triton X-114. Reagent extraction, complexation, and preconcentration were performed simultaneously using ultrasound-assisted extraction at 45 °C. The surfactant-rich phase was diluted with ethanol and loaded through a syringe barrel packed with cotton that acted as a filter to trap the reagent powder. Analyte-entrapped on cotton was eluted using 0.1 mol·L−1 nitric acid solution. Filtrate and eluate solutions were measured absorbance of the dark-blue product at 575 nm. Influential parameters for the procedure were investigated. Under the optimum experimental conditions, the calibration curve was linear, ranging from 0.1 to 1.0 mg·L−1 with r2 = 0.997. Limits of detection and quantification were 0.03 and 0.09 mg·L−1, respectively while precision values of intra-day and inter-day were less than 5%. Recovery at 0.5 mg·L−1 ranged from 89.0 to 99.8%, while iron content in vegetable samples ranged from 2.45 to 13.36 mg/100 g. This method was cost-effective, reliable, eco-friendly, and convenient as a green analytical approach to determining iron content.
Open AccessUltrasound-Assisted One-Pot Cloud Point Extraction for Iron Determination Using Natural Chelating Ligands from Dipterocarpus intricatus Dyer Fruit
An ultrasound-assisted, one-pot cloud point extraction was developed for the determination of iron in vegetable samples by UV-Visible spectrophotometry. This method was based on the complexation of iron with an environmentally-friendly natural chelating agent extracted from Dipterocarpus intricatus Dyer fruit at pH 5.5 in the presence of Triton X-114. Reagent extraction, complexation, and preconcentration were performed simultaneously using ultrasound-assisted extraction at 45 °C. The surfactant-rich phase was diluted with ethanol and loaded through a syringe barrel packed with cotton that acted as a filter to trap the reagent powder. Analyte-entrapped on cotton was eluted using 0.1 mol·L−1 nitric acid solution. Filtrate and eluate solutions were measured absorbance of the dark-blue product at 575 nm. Influential parameters for the procedure were investigated. Under the optimum experimental conditions, the calibration curve was linear, ranging from 0.1 to 1.0 mg·L−1 with r2 = 0.997. Limits of detection and quantification were 0.03 and 0.09 mg·L−1, respectively while precision values of intra-day and inter-day were less than 5%. Recovery at 0.5 mg·L−1 ranged from 89.0 to 99.8%, while iron content in vegetable samples ranged from 2.45 to 13.36 mg/100 g. This method was cost-effective, reliable, eco-friendly, and convenient as a green analytical approach to determining iron content.
- Open Access
Sustainable Downscaled Catalytic Colorimetric Determination of Manganese in Freshwater Using Smartphone-Based Monitoring Oxidation of 3,3′,5,5′-Tetramethylbenzidine by Periodate
A sustainable downscaled procedure using smartphone-based colorimetric determination of manganese (Mn(II)) was developed. This novel Mn(II) determination procedure is proposed using a simple, available microwell-plate platform and a smartphone as a detector. This approach is based on the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) by periodate using Mn(II) as a catalyst. The catalytic kinetics of Mn(II) under different conditions was investigated to determine the optimum condition where the different catalytic activities of various concentrations of Mn(II) evince. Under the optimum condition, the bluish-green product of oxidized TMB, proportioned to the concentration of Mn(II), was monitored using a smartphone camera, and the color signals were processed using ImageJ Software. The developed procedure showed great selectivity and sensitivity as linearity ranged from 1.8 × 10−6 to 4.6 × 10−5 M (0.1 to 2.5 μg/mL). The limits of detection and quantitation were 3.6 × 10−6 and 1.1 × 10−5 M (0.2 and 0.6 μg/mL), respectively. The determination of Mn(II) in freshwater samples was demonstrated to assess environmental water quality as an initial model to more easily promote water management according to the United Nations Sustainable Development Goals (UN-SDGs). The intensity of the red could be successfully applied to evaluate Mn(II) in canals and river water with no significant differences compared with the reference method of Inductively Coupled Plasma Optical Emission Spectrometry at a confidence level of 95%.
Open AccessSustainable Downscaled Catalytic Colorimetric Determination of Manganese in Freshwater Using Smartphone-Based Monitoring Oxidation of 3,3′,5,5′-Tetramethylbenzidine by Periodate
A sustainable downscaled procedure using smartphone-based colorimetric determination of manganese (Mn(II)) was developed. This novel Mn(II) determination procedure is proposed using a simple, available microwell-plate platform and a smartphone as a detector. This approach is based on the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) by periodate using Mn(II) as a catalyst. The catalytic kinetics of Mn(II) under different conditions was investigated to determine the optimum condition where the different catalytic activities of various concentrations of Mn(II) evince. Under the optimum condition, the bluish-green product of oxidized TMB, proportioned to the concentration of Mn(II), was monitored using a smartphone camera, and the color signals were processed using ImageJ Software. The developed procedure showed great selectivity and sensitivity as linearity ranged from 1.8 × 10−6 to 4.6 × 10−5 M (0.1 to 2.5 μg/mL). The limits of detection and quantitation were 3.6 × 10−6 and 1.1 × 10−5 M (0.2 and 0.6 μg/mL), respectively. The determination of Mn(II) in freshwater samples was demonstrated to assess environmental water quality as an initial model to more easily promote water management according to the United Nations Sustainable Development Goals (UN-SDGs). The intensity of the red could be successfully applied to evaluate Mn(II) in canals and river water with no significant differences compared with the reference method of Inductively Coupled Plasma Optical Emission Spectrometry at a confidence level of 95%.