Jianqi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jianqi Wang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Guohua Lu
4 shared publicationsSheng Li
Xijing University
3 shared publicationsXijing Jing
The Fourth Military Medical University, Xi’an
3 shared publicationsAnsheng Ni
2 shared publications- Teng Jiao
Department of Medical Electronics, School of Biomedical Engineering, Air Force Medical University, Xi’an 710032, China
2 shared publications Yang Zhang
The Fourth Military Medical University, Xi’an
2 shared publications
Latest Publications
- Open Access
- 1 September 2017
- Published by Universitas Ahmad Dahlan in TELKOMNIKA (Telecommunication Computing Electronics and Control)
- Vol. 15 (3) , 1072-1078
94 GHz Millimeter Wave Conducted Speech Enhancement
This paper is under in-depth investigation due to suspicion of possible plagiarism on a high similarity index The traditional microphone speech acquisition method has several limitations, such as short acquisition distance, non-directivity, weak ability to compensate for anti-acoustic noise, and poor sensitivity. As an alternative, our lab developed a new type of speech detection system using bio-radar. This novel speech detection method may effectively compensate for the shortcomings of the traditional microphone because of the special features of bio-radar. However, the detected radar speech is also corrupted by specific electromagnetic and ambient noises. Therefore, this study proposes a minimum mean-square error (MMSE) short-time spectral amplitude estimate algorithm to enhance radar captured speech. Because the proposed approach employs an optimal spectral amplitude estimator as well as a method to minimize the mean-square error of the log-spectra in enhancing noisy speech, this algorithm significantly reduces the colored residual noise. The enhanced radar speech was evaluated by both subjective and objective quality evaluation methods. The results demonstrate that the bio-radar can successfully detect speech signal and the proposed speech enhancement algorithm can improve radar captured speech quality.
- 1 September 2017
- Published by Universitas Ahmad Dahlan in TELKOMNIKA (Telecommunication Computing Electronics and Control)
- Vol. 15 (3) , 1072-1078
Open Access94 GHz Millimeter Wave Conducted Speech Enhancement
This paper is under in-depth investigation due to suspicion of possible plagiarism on a high similarity index The traditional microphone speech acquisition method has several limitations, such as short acquisition distance, non-directivity, weak ability to compensate for anti-acoustic noise, and poor sensitivity. As an alternative, our lab developed a new type of speech detection system using bio-radar. This novel speech detection method may effectively compensate for the shortcomings of the traditional microphone because of the special features of bio-radar. However, the detected radar speech is also corrupted by specific electromagnetic and ambient noises. Therefore, this study proposes a minimum mean-square error (MMSE) short-time spectral amplitude estimate algorithm to enhance radar captured speech. Because the proposed approach employs an optimal spectral amplitude estimator as well as a method to minimize the mean-square error of the log-spectra in enhancing noisy speech, this algorithm significantly reduces the colored residual noise. The enhanced radar speech was evaluated by both subjective and objective quality evaluation methods. The results demonstrate that the bio-radar can successfully detect speech signal and the proposed speech enhancement algorithm can improve radar captured speech quality.
- 1 July 2015
- Vol. 39 (4) , 244-8
[Development of Non-Contact Monitoring Device for Breathing and Heartbeat].
Physiological monitoring devices in modern clinical area are basically used electrodes or sensors directly touching the surface of human subject body, which will increase physiological and psychological load of the subjects. In order to realize non-contact monitoring of respiration and heartbeat, firstly, the micro bioradar was used to detect human body motion signal. Then, the respiration signal and heartbeat signal was extracted from the body-motion signal by using signal and conditioning circuits, digital filter and signal processing. Finally, the results of heart rate and breathing rate was wirelessly transmitted. The experimental results showed that the device for non-contact monitoring of respiration and heartbeat waveforms has advantages of small volume, low power consumption, which can realize the monitoring of physiological parameters in real time.
- 1 July 2015
- Vol. 39 (4) , 244-8
[Development of Non-Contact Monitoring Device for Breathing and Heartbeat].
Physiological monitoring devices in modern clinical area are basically used electrodes or sensors directly touching the surface of human subject body, which will increase physiological and psychological load of the subjects. In order to realize non-contact monitoring of respiration and heartbeat, firstly, the micro bioradar was used to detect human body motion signal. Then, the respiration signal and heartbeat signal was extracted from the body-motion signal by using signal and conditioning circuits, digital filter and signal processing. Finally, the results of heart rate and breathing rate was wirelessly transmitted. The experimental results showed that the device for non-contact monitoring of respiration and heartbeat waveforms has advantages of small volume, low power consumption, which can realize the monitoring of physiological parameters in real time.
- Open Access
A 94-GHz Millimeter-Wave Sensor for Speech Signal Acquisition
High frequency millimeter-wave (MMW) radar-like sensors enable the detection of speech signals. This novel non-acoustic speech detection method has some special advantages not offered by traditional microphones, such as preventing strong-acoustic interference, high directional sensitivity with penetration, and long detection distance. A 94-GHz MMW radar sensor was employed in this study to test its speech acquisition ability. A 34-GHz zero intermediate frequency radar, a 34-GHz superheterodyne radar, and a microphone were also used for comparison purposes. A short-time phase-spectrum-compensation algorithm was used to enhance the detected speech. The results reveal that the 94-GHz radar sensor showed the highest sensitivity and obtained the highest speech quality subjective measurement score. This result suggests that the MMW radar sensor has better performance than a traditional microphone in terms of speech detection for detection distances longer than 1 m. As a substitute for the traditional speech acquisition method, this novel speech acquisition method demonstrates a large potential for many speech related applications.
Open AccessA 94-GHz Millimeter-Wave Sensor for Speech Signal Acquisition
High frequency millimeter-wave (MMW) radar-like sensors enable the detection of speech signals. This novel non-acoustic speech detection method has some special advantages not offered by traditional microphones, such as preventing strong-acoustic interference, high directional sensitivity with penetration, and long detection distance. A 94-GHz MMW radar sensor was employed in this study to test its speech acquisition ability. A 34-GHz zero intermediate frequency radar, a 34-GHz superheterodyne radar, and a microphone were also used for comparison purposes. A short-time phase-spectrum-compensation algorithm was used to enhance the detected speech. The results reveal that the 94-GHz radar sensor showed the highest sensitivity and obtained the highest speech quality subjective measurement score. This result suggests that the MMW radar sensor has better performance than a traditional microphone in terms of speech detection for detection distances longer than 1 m. As a substitute for the traditional speech acquisition method, this novel speech acquisition method demonstrates a large potential for many speech related applications.
- 1 January 2013
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research M
- Vol. 31, 263-278
SIMULATION OF SAR UNDER ULTRA-WIDE BAND ELECTROMAGNETIC PULSE IN HUMAN TISSUE
- 1 January 2013
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research M
- Vol. 31, 263-278
SIMULATION OF SAR UNDER ULTRA-WIDE BAND ELECTROMAGNETIC PULSE IN HUMAN TISSUE
- 1 January 2013
- Published by Institute of Advanced Engineering and Science in TELKOMNIKA Indonesian Journal of Electrical Engineering
- Vol. 11 (1) , 130-135
Enhancement of Non-Air Conducted Speech Based on Wavelet-Packet Adaptive Threshold
This study developed a new kind of speech detecting method by using millimeter wave. Because of the advantage of the millimeter wave, this speech detecting method has great potential application and may provide some exciting possibility for wide applications. However, the MMW conduct speech is in less intelligible and poor audibility since it is corrupted by additive combined noise. This paper, therefore, also developed an algorithm of wavelet packet threshold by using hard threshold and soft threshold for removing noise based on the good capability of wavelet packet for analyzing time-frequency signal. Comparing to traditional speech enhancement algorithm, the results from both simulation and listening evaluation suggest that the proposed algorithm takes on a better performance on noise removing while the distortion of MMW radar speech remains acceptable, the enhanced speech also sounds more pleasant to human listeners, resulting in improved results over classical speech enhancement algorithms.
- 1 January 2013
- Published by Institute of Advanced Engineering and Science in TELKOMNIKA Indonesian Journal of Electrical Engineering
- Vol. 11 (1) , 130-135
Enhancement of Non-Air Conducted Speech Based on Wavelet-Packet Adaptive Threshold
This study developed a new kind of speech detecting method by using millimeter wave. Because of the advantage of the millimeter wave, this speech detecting method has great potential application and may provide some exciting possibility for wide applications. However, the MMW conduct speech is in less intelligible and poor audibility since it is corrupted by additive combined noise. This paper, therefore, also developed an algorithm of wavelet packet threshold by using hard threshold and soft threshold for removing noise based on the good capability of wavelet packet for analyzing time-frequency signal. Comparing to traditional speech enhancement algorithm, the results from both simulation and listening evaluation suggest that the proposed algorithm takes on a better performance on noise removing while the distortion of MMW radar speech remains acceptable, the enhanced speech also sounds more pleasant to human listeners, resulting in improved results over classical speech enhancement algorithms.
- 13 December 2012
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 191, 99-104
Smart radar sensor for speech detection and enhancement
- 13 December 2012
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 191, 99-104
Smart radar sensor for speech detection and enhancement
- 1 August 2006
- Vol. 23 (4) , 695-8
[Study on second filtering algorithm based on tracing the interfering spectral peaks of radar non-contact life-parameter detection system].
To develop a filtering algorithm which could trace the spectral peaks of the interference and which was used to extract the breath signal with the same band interference in radar non-contact life-detecting system, second filtering algorithm was studied. Through first filtering,the probable interfering spectral peaks (ISP) could be detected by Yule-Walker spectrum estimating and could be located by calculating the coefficients of normalized cross-correlation function according to standard breath signal. Thus the breath signal could be extracted through a second filtering. By using the second filtering algorithm (SFA), the same band interfering spectral peaks with breath signal could be recognized and inhibited. So we conclude that the same band mono-ISP could be inhibited by using SFA and breath signals could be effectively extracted.
- 1 August 2006
- Vol. 23 (4) , 695-8
[Study on second filtering algorithm based on tracing the interfering spectral peaks of radar non-contact life-parameter detection system].
To develop a filtering algorithm which could trace the spectral peaks of the interference and which was used to extract the breath signal with the same band interference in radar non-contact life-detecting system, second filtering algorithm was studied. Through first filtering,the probable interfering spectral peaks (ISP) could be detected by Yule-Walker spectrum estimating and could be located by calculating the coefficients of normalized cross-correlation function according to standard breath signal. Thus the breath signal could be extracted through a second filtering. By using the second filtering algorithm (SFA), the same band interfering spectral peaks with breath signal could be recognized and inhibited. So we conclude that the same band mono-ISP could be inhibited by using SFA and breath signals could be effectively extracted.
- 1 October 2004
- Vol. 21 (5) , 749-52
[Study on eliminating self-dithering interference of the system for non-contact detecting life parameters based on an adaptive algorithm].
The non-contact life parameters detecting systems can detect many important life parameters such as heartbeat and breathing at certain distance. In practice, the self-dithering interference of the system is produced by some factors; it makes the signal-to-noise ratio (SNR) of the recorded signal lower. This paper is discussed an adaptive technology based on a variable step-size LMS algorithm, which is used to eliminate the self-dithering interference of the system and hence to raise the SNR of the detecting signal. A method to obtain the reference signal by vibration sensor is brought forward and the optimum parameters settings are discussed. The results show that the reference signal is an integral part of output signal of the vibration sensor and has a relationship with the setting direction of the sensor. The conclusion is that the method is effective and feasible; also the algorithm is well convergent.
- 1 October 2004
- Vol. 21 (5) , 749-52
[Study on eliminating self-dithering interference of the system for non-contact detecting life parameters based on an adaptive algorithm].
The non-contact life parameters detecting systems can detect many important life parameters such as heartbeat and breathing at certain distance. In practice, the self-dithering interference of the system is produced by some factors; it makes the signal-to-noise ratio (SNR) of the recorded signal lower. This paper is discussed an adaptive technology based on a variable step-size LMS algorithm, which is used to eliminate the self-dithering interference of the system and hence to raise the SNR of the detecting signal. A method to obtain the reference signal by vibration sensor is brought forward and the optimum parameters settings are discussed. The results show that the reference signal is an integral part of output signal of the vibration sensor and has a relationship with the setting direction of the sensor. The conclusion is that the method is effective and feasible; also the algorithm is well convergent.