Wolfgang Schade
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wolfgang Schade has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jörg Burgmeier
Fraunhofer-Institut für Nachrichtentechnik Heinrich-Hertz-Institut (Germany)
4 shared publications - Christian Bohling
SECOPTA GmbH (Germany)
2 shared publications - Christoph Bauer2 shared publications
- Gerhard Holl2 shared publications
- Jan Koch
Fraunhofer-Institut für Nachrichtentechnik Heinrich-Hertz-Institut (Germany)
2 shared publications U. Willer
Institute for Energy Research and Physical Technology, Clausthal University of Technology, Goslar, Germany
2 shared publications
Latest Publications
- 31 July 2013
- Published by Wiley in Physica Status Solidi (a)
- Vol. 210 (10) , 2219-2223
Synthesis of ZnO nanowalls and nanocombs by vapor-liquid-solid method
- 31 July 2013
- Published by Wiley in Physica Status Solidi (a)
- Vol. 210 (10) , 2219-2223
Synthesis of ZnO nanowalls and nanocombs by vapor-liquid-solid method
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8421, 84215G
Intensity-independent fiber coupled interrogation technique for fiber Bragg gratings by fiber Bragg gratings
A low cost, highly accurate and light intensity-independent sensor system for the analysis of fiber Bragg grating signals based on fiber Bragg gratings in the detection unit is presented. The setup is based on two fiber Bragg gratings used in reflection to analyse one sensing fiber Bragg grating. The Bragg gratings were inscribed in coated non-photosensitive standard telecommunication fibers using an infrared femtosecond laser and the point-by-point writing technique. The accuracy of this interrogation concept is presented by means of a temperature measurement with a resolution better than 0.12°C in a linear operation range of 20°C.
- 17 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8421, 84215G
Intensity-independent fiber coupled interrogation technique for fiber Bragg gratings by fiber Bragg gratings
A low cost, highly accurate and light intensity-independent sensor system for the analysis of fiber Bragg grating signals based on fiber Bragg gratings in the detection unit is presented. The setup is based on two fiber Bragg gratings used in reflection to analyse one sensing fiber Bragg grating. The Bragg gratings were inscribed in coated non-photosensitive standard telecommunication fibers using an infrared femtosecond laser and the point-by-point writing technique. The accuracy of this interrogation concept is presented by means of a temperature measurement with a resolution better than 0.12°C in a linear operation range of 20°C.
- 7 October 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7838, 783807
Trace detection of nitrogen-based explosives with UV-PLF
Trace detection of energetic materials is a method to screen personnel, packages and other items for concealed explosives. It is likely, that a person who carries explosives will contaminate himself and the package with the explosive. We present first results on the development of a compact detector combining Pulsed Laser Fragmentation (PLF) with fragments detection. A passively q-switched UV microchip laser photofragments surface contaminations. The concentration ratio of the fragments NO and NO2 is a sufficient indicator for the presence of nitrogen-based explosives. For TNT, the results suggest, that a surface density as small as a few ng/cm2 can be reliably detected.
- 7 October 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7838, 783807
Trace detection of nitrogen-based explosives with UV-PLF
Trace detection of energetic materials is a method to screen personnel, packages and other items for concealed explosives. It is likely, that a person who carries explosives will contaminate himself and the package with the explosive. We present first results on the development of a compact detector combining Pulsed Laser Fragmentation (PLF) with fragments detection. A passively q-switched UV microchip laser photofragments surface contaminations. The concentration ratio of the fragments NO and NO2 is a sufficient indicator for the presence of nitrogen-based explosives. For TNT, the results suggest, that a surface density as small as a few ng/cm2 can be reliably detected.
- 18 September 2010
- Published by Springer Nature in Applied Physics B
- Vol. 102 (1) , 133-139
Tuning fork enhanced interferometric photoacoustic spectroscopy: a new method for trace gas analysis
- 18 September 2010
- Published by Springer Nature in Applied Physics B
- Vol. 102 (1) , 133-139
Tuning fork enhanced interferometric photoacoustic spectroscopy: a new method for trace gas analysis
- Open Access
A Microring Resonator Sensor for Sensitive Detection of 1,3,5-Trinitrotoluene (TNT)
A microring resonator sensor device for sensitive detection of the explosive 1,3,5-trinitrotoluene (TNT) is presented. It is based on the combination of a silicon microring resonator and tailored receptor molecules.
Open AccessA Microring Resonator Sensor for Sensitive Detection of 1,3,5-Trinitrotoluene (TNT)
A microring resonator sensor device for sensitive detection of the explosive 1,3,5-trinitrotoluene (TNT) is presented. It is based on the combination of a silicon microring resonator and tailored receptor molecules.
- 14 July 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (2) , 275-282
Photonic sensor devices for explosive detection
For the sensitive online and in situ detection of gaseous species, optical methods are ideally suited. In contrast to chemical analysis, no sample preparation is necessary and therefore spectroscopic methods should be favorable both in respect of a fast signal recovery and economically because no disposal is needed. However, spectroscopic methods are currently not widely used for security applications. We review photonic sensor devices for the detection of explosives in the gas phase as well as the condensed phase and the underlying spectroscopic techniques with respect to their adaptability for security applications, where high sensitivity, high selectivity, and a low false-alarm rate are of importance. The measurements have to be performed under ambient conditions and often remote handling or even operation in standoff configuration is needed. For handheld and portable equipment, special attention is focused on the miniaturization and examples for already-available sensor devices are given.
- 14 July 2009
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 395 (2) , 275-282
Photonic sensor devices for explosive detection
For the sensitive online and in situ detection of gaseous species, optical methods are ideally suited. In contrast to chemical analysis, no sample preparation is necessary and therefore spectroscopic methods should be favorable both in respect of a fast signal recovery and economically because no disposal is needed. However, spectroscopic methods are currently not widely used for security applications. We review photonic sensor devices for the detection of explosives in the gas phase as well as the condensed phase and the underlying spectroscopic techniques with respect to their adaptability for security applications, where high sensitivity, high selectivity, and a low false-alarm rate are of importance. The measurements have to be performed under ambient conditions and often remote handling or even operation in standoff configuration is needed. For handheld and portable equipment, special attention is focused on the miniaturization and examples for already-available sensor devices are given.
- 22 December 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (4) , B119-B125
Resonant tuning fork detector for electromagnetic radiation
A mechanical quartz microresonator (tuning fork) is used to detect electromagnetic radiation. The detection scheme is based on forces created due to the incident electromagnetic radiation on the piezoelectric tuning fork. A force can be created due to the transfer of the photon momentum of the incident electromagnetic radiation. If the surfaces of the tuning fork are nonuniformly heated, a second force acts on it, the so-called photophoretic force. These processes occur for all wavelengths of the incident radiation, making the detector suitable for sensing of ultraviolet, visible, and mid-infrared light, even THz- radiation. Here the detector is characterized in the visible range; noise analysis is performed for and . A linear power characteristic and the dependence on pulse lengths of the incoming light are shown. Examples for applications for the visible and mid-infrared spectral region are given by and absorption spectroscopy of oxygen and nitric oxide, respectively.- 22 December 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (4) , B119-B125
Resonant tuning fork detector for electromagnetic radiation
A mechanical quartz microresonator (tuning fork) is used to detect electromagnetic radiation. The detection scheme is based on forces created due to the incident electromagnetic radiation on the piezoelectric tuning fork. A force can be created due to the transfer of the photon momentum of the incident electromagnetic radiation. If the surfaces of the tuning fork are nonuniformly heated, a second force acts on it, the so-called photophoretic force. These processes occur for all wavelengths of the incident radiation, making the detector suitable for sensing of ultraviolet, visible, and mid-infrared light, even THz- radiation. Here the detector is characterized in the visible range; noise analysis is performed for and . A linear power characteristic and the dependence on pulse lengths of the incoming light are shown. Examples for applications for the visible and mid-infrared spectral region are given by and absorption spectroscopy of oxygen and nitric oxide, respectively.- 13 August 2008
- Published by Springer Nature in Applied Physics B
- Vol. 92 (3) , 327-333
Potentials and limits of mid-infrared laser spectroscopy for the detection of explosives
- 13 August 2008
- Published by Springer Nature in Applied Physics B
- Vol. 92 (3) , 327-333
Potentials and limits of mid-infrared laser spectroscopy for the detection of explosives
- 1 January 2007
- Published by Optica Publishing Group
A Fiber-Coupled Eye Safe Spectrometer for the Stand-off Detection of Explosives
A compact laser spectrometer for the detection of explosives from a safe spot is presented. This laser setup also opens the possibility for the trace detection of explosives.
- 1 January 2007
- Published by Optica Publishing Group
A Fiber-Coupled Eye Safe Spectrometer for the Stand-off Detection of Explosives
A compact laser spectrometer for the detection of explosives from a safe spot is presented. This laser setup also opens the possibility for the trace detection of explosives.
- 1 January 2006
- Published by Optica Publishing Group
- p. PThD4
Remote Detection of Explosive Contaminated Surfaces by Mid-Infrared Lasers
Vaporization of explosives is done at 1.5 µm and the vapor is analyzed for NO emission by MIR laser spectroscopy. The ratio of NO/NOx is an indicator to distinguish between energetic and non-energetic materials.
- 1 January 2006
- Published by Optica Publishing Group
- p. PThD4
Remote Detection of Explosive Contaminated Surfaces by Mid-Infrared Lasers
Vaporization of explosives is done at 1.5 µm and the vapor is analyzed for NO emission by MIR laser spectroscopy. The ratio of NO/NOx is an indicator to distinguish between energetic and non-energetic materials.