IMInkyu Moon

Inkyu Moon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Inkyu Moon has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Three-dimensional image authentication scheme using sparse phase information in double random phase encoded integral imaging

    by Faliu Yi, Yousun Jeoung, Inkyu Moon

    In recent years, many studies have focused on authentication of two-dimensional (2D) images using double random phase encryption techniques. However, there has been little research on three-dimensional (3D) imaging systems, such as integral imaging, for 3D image authentication. We propose a 3D image authentication scheme based on a double random phase integral imaging method. All of the 2D elemental images captured through integral imaging are encrypted with a double random phase encoding algorithm and only partial phase information is reserved. All the amplitude and other miscellaneous phase information in the encrypted elemental images is discarded. Nevertheless, we demonstrate that 3D images from integral imaging can be authenticated at different depths using a nonlinear correlation method. The proposed 3D image authentication algorithm can provide enhanced information security because the decrypted 2D elemental images from the sparse phase cannot be easily observed by the naked eye. Additionally, using sparse phase images without any amplitude information can greatly reduce data storage costs and aid in image compression and data transmission.


  • Lossless and lossy compression of quantitative phase images of red blood cells obtained by digital holographic imaging

    by Keyvan Jaferzadeh, Samaneh Gholami, Inkyu Moon

    In this paper, we evaluate lossless and lossy compression techniques to compress quantitative phase images of red blood cells (RBCs) obtained by an off-axis digital holographic microscopy (DHM). The RBC phase images are numerically reconstructed from their digital holograms and are stored in 16-bit unsigned integer format. In the case of lossless compression, predictive coding of JPEG lossless (JPEG-LS), JPEG2000, and JP3D are evaluated, and compression ratio (CR) and complexity (compression time) are compared against each other. It turns out that JP2k can outperform other methods by having the best CR. In the lossy case, JP2k and JP3D with different CRs are examined. Because some data is lost in a lossy way, the degradation level is measured by comparing different morphological and biochemical parameters of RBC before and after compression. Morphological parameters are volume, surface area, RBC diameter, sphericity index, and the biochemical cell parameter is mean corpuscular hemoglobin (MCH). Experimental results show that JP2k outperforms JP3D not only in terms of mean square error (MSE) when CR increases, but also in compression time in the lossy compression way. In addition, our compression results with both algorithms demonstrate that with high CR values the three-dimensional profile of RBC can be preserved and morphological and biochemical parameters can still be within the range of reported values.


  • Open Access

    Cell morphology-based classification of red blood cells using holographic imaging informatics

    by Faliu Yi, Inkyu Moon, Bahram Javidi

    We present methods that automatically select a linear or nonlinear classifier for red blood cell (RBC) classification by analyzing the equality of the covariance matrices in Gabor-filtered holographic images. First, the phase images of the RBCs are numerically reconstructed from their holograms, which are recorded using off-axis digital holographic microscopy (DHM). Second, each RBC is segmented using a marker-controlled watershed transform algorithm and the inner part of the RBC is identified and analyzed. Third, the Gabor wavelet transform is applied to the segmented cells to extract a series of features, which then undergo a multivariate statistical test to evaluate the equality of the covariance matrices of the different shapes of the RBCs using selected features. When these covariance matrices are not equal, a nonlinear classification scheme based on quadratic functions is applied; otherwise, a linear classification is applied. We used the stomatocyte, discocyte, and echinocyte RBC for classifier training and testing. Simulation results demonstrated that 10 of the 14 RBC features are useful in RBC classification. Experimental results also revealed that the covariance matrices of the three main RBC groups are not equal and that a nonlinear classification method has a much lower misclassification rate. The proposed automated RBC classification method has the potential for use in drug testing and the diagnosis of RBC-related diseases.


  • Automated tracking of temporal displacements of a red blood cell obtained by time-lapse digital holographic microscopy

    by Inkyu Moon, Faliu Yi, Benjamin Rappaz

    Red blood cell (RBC) phase images that are numerically reconstructed by digital holographic microscopy (DHM) can describe the cell structure and dynamics information beneficial for a quantitative analysis of RBCs. However, RBCs investigated with time-lapse DHM undergo temporal displacements when their membranes are loosely attached to the substrate during sedimentation on a glass surface or due to the microscope drift. Therefore, we need to develop a tracking algorithm to localize the same RBC among RBC image sequences and dynamically monitor its biophysical cell parameters; this information is helpful for studies on RBC-related diseases and drug tests. Here, we propose a method, which is a combination of the mean-shift algorithm and Kalman filter, to track a single RBC and demonstrate that the optical path length of the single RBC can be continually extracted from the tracked RBC. The Kalman filter is utilized to predict the target RBC position in the next frame. Then, the mean-shift algorithm starts execution from the predicted location, and a robust kernel, which is adaptive to changes in the RBC scale, shape, and direction, is designed to improve the accuracy of the tracking. Finally, the tracked RBC is segmented and parameters such as the RBC location are extracted to update the Kalman filter and the kernel function for mean-shift tracking; the characteristics of the target RBC are dynamically observed. Experimental results show the feasibility of the proposed algorithm.


  • Open Access

    A Multispectral Photon-Counting Double Random Phase Encoding Scheme for Image Authentication

    by Faliu Yi, Inkyu Moon, Yeon H. Lee

    In this paper, we propose a new method for color image-based authentication that combines multispectral photon-counting imaging (MPCI) and double random phase encoding (DRPE) schemes. The sparsely distributed information from MPCI and the stationary white noise signal from DRPE make intruder attacks difficult. In this authentication method, the original multispectral RGB color image is down-sampled into a Bayer image. The three types of color samples (red, green and blue color) in the Bayer image are encrypted with DRPE and the amplitude part of the resulting image is photon counted. The corresponding phase information that has nonzero amplitude after photon counting is then kept for decryption. Experimental results show that the retrieved images from the proposed method do not visually resemble their original counterparts. Nevertheless, the original color image can be efficiently verified with statistical nonlinear correlations. Our experimental results also show that different interpolation algorithms applied to Bayer images result in different verification effects for multispectral RGB color images.


  • Simultaneous reconstruction of multiple depth images without off-focus points in integral imaging using a graphics processing unit

    by Faliu Yi, Jieun Lee, Inkyu Moon

    The reconstruction of multiple depth images with a ray back-propagation algorithm in three-dimensional (3D) computational integral imaging is computationally burdensome. Further, a reconstructed depth image consists of a focus and an off-focus area. Focus areas are 3D points on the surface of an object that are located at the reconstructed depth, while off-focus areas include 3D points in free-space that do not belong to any object surface in 3D space. Generally, without being removed, the presence of an off-focus area would adversely affect the high-level analysis of a 3D object, including its classification, recognition, and tracking. Here, we use a graphics processing unit (GPU) that supports parallel processing with multiple processors to simultaneously reconstruct multiple depth images using a lookup table containing the shifted values along the x and y directions for each elemental image in a given depth range. Moreover, each 3D point on a depth image can be measured by analyzing its statistical variance with its corresponding samples, which are captured by the two-dimensional (2D) elemental images. These statistical variances can be used to classify depth image pixels as either focus or off-focus points. At this stage, the measurement of focus and off-focus points in multiple depth images is also implemented in parallel on a GPU. Our proposed method is conducted based on the assumption that there is no occlusion of the 3D object during the capture stage of the integral imaging process. Experimental results have demonstrated that this method is capable of removing off-focus points in the reconstructed depth image. The results also showed that using a GPU to remove the off-focus points could greatly improve the overall computational speed compared with using a CPU.


  • Automated quantitative analysis of 3D morphology and mean corpuscular hemoglobin in human red blood cells stored in different periods

    by Inkyu Moon, Faliu Yi, Yeon H. Lee, Bahram Javidi, Daniel Boss, Pierre Marquet

    Quantitative phase (QP) images of red blood cells (RBCs), which are obtained by off-axis digital holographic microscopy, can provide quantitative information about three-dimensional (3D) morphology of human RBCs and the characteristic properties such as mean corpuscular hemoglobin (MCH) and MCH surface density (MCHSD). In this paper, we investigate modifications of the 3D morphology and MCH in RBCs induced by the period of storage time for the purpose of classification of RBCs with different periods of storage by using off-axis digital holographic microscopy. The classification of RBCs based on the duration of storage is highly relevant because a long storage of blood before transfusion may alter the functionality of RBCs and, therefore, cause complications in patients. To analyze any changes in the 3D morphology and MCH of RBCs due to storage, we use data sets from RBC samples stored for 8, 13, 16, 23, 27, 30, 34, 37, 40, 47, and 57 days, respectively. The data sets consist of more than 3,300 blood cells in eleven classes, with more than 300 blood cells per class. The classes indicate the storage period of RBCs and are listed in chronological order. Using the RBCs donated by healthy persons, the off-axis digital holographic microscopy reconstructs several quantitative phase images of RBC samples stored for eleven different periods. We employ marker-controlled watershed transform to remove the background in the RBC quantitative phase images obtained by the off-axis digital holographic microscopy. More than 300 single RBCs are extracted from the segmented quantitative phase images for each class. Such a large number of RBC samples enable us to obtain statistical distributions of the characteristic properties of RBCs after a specific period of storage. Experimental results show that the 3D morphology of the RBCs, in contrast to MCH, is essentially related to the aging of the RBCs.


  • Hybrid square-lattice photonic crystal fiber with high birefringence and negative dispersion

    by So Eun Kim, Chung Ghiu Lee, Inkyu Moon, Chul-Sik Kee

    We have proposed a hybrid square-lattice PCF using two different sized air holes and conventional square lattice cladding structure. Based on the plane wave expansion method and finite element method, we numerically investigated it polarization and dispersion properties compared to the conventional square lattice photonic crystal fiber. From the numerical results, it is shown that the proposed structure provides high birefringence and still maintains negative dispersion property. Numerical results show that the birefringence of the hybrid square-lattice PCF reaches 10-2. The value and slope of the chromatic dispersion are also negative over the C band.