Mark F. Tardiff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mark F. Tardiff has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Stephen J. Walsh
Department of Mathematics and Statistics Utah State University Logan Utah USA
3 shared publications - Candace N. Metoyer
Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99352, USA
2 shared publications - Kevin K. Anderson
Pacific Northwest National Laboratory, Richland, WA, USA
2 shared publications - Lawrence Chilton
Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99352, USA
2 shared publications Danny Katzman
Los Alamos National Laboratory, Post Office Box 1663,Los Alamos,USA
1 shared publicationLawrence Chilton
1 shared publication
Latest Publications
- Open Access
Predicting the Detectability of Thin Gaseous Plumes in Hyperspectral Images Using Basis Vectors
This paper describes a new method for predicting the detectability of thin gaseous plumes in hyperspectral images. The novelty of this method is the use of basis vectors for each of the spectral channels of a collection instrument to calculate noise-equivalent concentration-pathlengths instead of matching scene pixels to absorbance spectra of gases in a library. This method provides insight into regions of the spectrum where gas detection will be relatively easier or harder, as influenced by ground emissivity, temperature contrast, and the atmosphere. Our results show that data collection planning could be influenced by information about when potential plumes are likely to be over background segments that are most conducive to detection.
Open AccessPredicting the Detectability of Thin Gaseous Plumes in Hyperspectral Images Using Basis Vectors
This paper describes a new method for predicting the detectability of thin gaseous plumes in hyperspectral images. The novelty of this method is the use of basis vectors for each of the spectral channels of a collection instrument to calculate noise-equivalent concentration-pathlengths instead of matching scene pixels to absorbance spectra of gases in a library. This method provides insight into regions of the spectrum where gas detection will be relatively easier or harder, as influenced by ground emissivity, temperature contrast, and the atmosphere. Our results show that data collection planning could be influenced by information about when potential plumes are likely to be over background segments that are most conducive to detection.
- 29 December 2009
- Published by Office of Scientific and Technical Information (OSTI)
Predicting detection probabilities for gas mixtures over HSI backgrounds
Detecting and identifying weak gaseous plumes using thermal image data acquired by airborne detectors is an area of ongoing research. This contribution investigates the relative detectability of gas mixtures over different backgrounds and a range of plume temperatures that are warmer and cooler than the ground. The focus of this analysis to support mission planning. When the mission is intended to collect evidence of particular chemicals, the analysis presented is this report can be used to determine conditions under which useful data can be acquired. Initial analyses can be used to determine whether LWIR is useful for the anticipated gas, temperature, and background combination.
- 29 December 2009
- Published by Office of Scientific and Technical Information (OSTI)
Predicting detection probabilities for gas mixtures over HSI backgrounds
Detecting and identifying weak gaseous plumes using thermal image data acquired by airborne detectors is an area of ongoing research. This contribution investigates the relative detectability of gas mixtures over different backgrounds and a range of plume temperatures that are warmer and cooler than the ground. The focus of this analysis to support mission planning. When the mission is intended to collect evidence of particular chemicals, the analysis presented is this report can be used to determine conditions under which useful data can be acquired. Initial analyses can be used to determine whether LWIR is useful for the anticipated gas, temperature, and background combination.
- Open Access
Effect of the Temperature-Emissivity Contrast on the Chemical Signal for Gas Plume Detection Using Thermal Image Data
Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. These include variability due to atmosphere, ground and plume temperature, and background clutter. This paper presents an analysis of one formulation of the physics-based radiance model, which describes at-sensor observed radiance. The background emissivity and plume/ground temperatures are isolated, and their effects on chemical signal are described. This analysis shows that the plume’s physical state, emission or absorption, is directly dependent on the background emissivity and plume/ground temperatures. It then describes what conditions on the background emissivity and plume/ground temperatures have inhibiting or amplifying effects on the chemical signal. These claims are illustrated by analyzing synthetic hyperspectral imaging data with the adaptive matched filter using two chemicals and three distinct background emissivities.
Open AccessEffect of the Temperature-Emissivity Contrast on the Chemical Signal for Gas Plume Detection Using Thermal Image Data
Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. These include variability due to atmosphere, ground and plume temperature, and background clutter. This paper presents an analysis of one formulation of the physics-based radiance model, which describes at-sensor observed radiance. The background emissivity and plume/ground temperatures are isolated, and their effects on chemical signal are described. This analysis shows that the plume’s physical state, emission or absorption, is directly dependent on the background emissivity and plume/ground temperatures. It then describes what conditions on the background emissivity and plume/ground temperatures have inhibiting or amplifying effects on the chemical signal. These claims are illustrated by analyzing synthetic hyperspectral imaging data with the adaptive matched filter using two chemicals and three distinct background emissivities.
- 2 October 2008
- Published by Office of Scientific and Technical Information (OSTI)
Effect of Background Emissivity on Gas Detection in Thermal Hyperspectral Imagery
Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. These include variability due to atmosphere, ground and plume temper- ature, and background clutter. This paper presents an analysis of one formulation of the physics-based radiance model, which describes at-sensor observed radiance. The background emissivity and plume/ground temperatures are isolated, and their effects on net chemical signal are described. This analysis shows that the plume’s physical state, emission or absorption, is directly dependent on the background emissivity. It then describes what conditions on the background emissivity have inhibiting effects on the net chemical signal. These claims are illustrated by analyzing synthetic hyperspectral imaging data with the Adaptive Matched Filter using four chemicals and three distinct background emissivities. Two chemicals (Carbontetrachloride and Tetraflourosilane) in the analysis had a very strong relationship with the background emissivities: they exhibited absorbance over a small range of wavenumbers and the background emissivities showed a consistent ordering at these wavenumbers. Analysis of simulated hyperspectral images containing these chemicals showed complete agreement with the analysis of the physics-based model that described when the background emissivities would have inhibiting effects on gas detection. The other chemicals considered (Ammonia and Tributylphosphate) exhibited very complexmore » absorbance structure across the longwave infrared spectrum. Analysis of images containing these chemicals revealed that the the analysis of the physics-based model did not hold completely for these complex chemicals but did suggest that gas detection was dominated by their dominant absorbance features. These results provide some explanation of the effect of the background emissivity on gas detection and a more general exploration of gas absorbance/background emissivity variability and their effects on gas detection is warranted. i« less
- 2 October 2008
- Published by Office of Scientific and Technical Information (OSTI)
Effect of Background Emissivity on Gas Detection in Thermal Hyperspectral Imagery
Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. These include variability due to atmosphere, ground and plume temper- ature, and background clutter. This paper presents an analysis of one formulation of the physics-based radiance model, which describes at-sensor observed radiance. The background emissivity and plume/ground temperatures are isolated, and their effects on net chemical signal are described. This analysis shows that the plume’s physical state, emission or absorption, is directly dependent on the background emissivity. It then describes what conditions on the background emissivity have inhibiting effects on the net chemical signal. These claims are illustrated by analyzing synthetic hyperspectral imaging data with the Adaptive Matched Filter using four chemicals and three distinct background emissivities. Two chemicals (Carbontetrachloride and Tetraflourosilane) in the analysis had a very strong relationship with the background emissivities: they exhibited absorbance over a small range of wavenumbers and the background emissivities showed a consistent ordering at these wavenumbers. Analysis of simulated hyperspectral images containing these chemicals showed complete agreement with the analysis of the physics-based model that described when the background emissivities would have inhibiting effects on gas detection. The other chemicals considered (Ammonia and Tributylphosphate) exhibited very complexmore » absorbance structure across the longwave infrared spectrum. Analysis of images containing these chemicals revealed that the the analysis of the physics-based model did not hold completely for these complex chemicals but did suggest that gas detection was dominated by their dominant absorbance features. These results provide some explanation of the effect of the background emissivity on gas detection and a more general exploration of gas absorbance/background emissivity variability and their effects on gas detection is warranted. i« less
- 9 February 2007
- Published by Royal Society of Chemistry (RSC)
- Vol. 9 (3) , 266-274
Estimating contaminant attenuation half-lives in alluvial groundwater systems
One aspect of describing contamination in an alluvial aquifer is estimating changes in concentrations over time. A variety of statistical methods are available for assessing trends in contaminant concentrations. We present a method that extends trend analysis to include estimating the coefficients for the exponential decay equation and calculating contaminant attenuation half-lives. The conceptual model for this approach assumes that the rate of decline is proportional to the contaminant concentration in an aquifer. Consequently, the amount of time to remove a unit quantity of the contaminant inventory from an aquifer lengthens as the concentration decreases. Support for this conceptual model is demonstrated empirically with log-transformed time series of contaminant data. Equations are provided for calculating system attenuation half-lives for non-radioactive contaminants. For radioactive contaminants, the system attenuation half-life is partitioned into the intrinsic radioactive decay and the concentration reduction caused by aquifer processes. Examples are presented that provide the details of this approach. In addition to gaining an understanding of aquifer characteristics and changes in constituent concentrations, this method can be used to assess compliance with regulatory standards and to estimate the time to compliance when natural attenuation is being considered as a remediation strategy. A special application of this method is also provided that estimates the half-life of the residence time for groundwater in the aquifer by estimating the half life for a conservative contaminant that is no longer being released into the aquifer. Finally, the ratio of the half-life for groundwater residence time to the attenuation half-life for a contaminant is discussed as a system-scale retardation factor which can be used in analytical and numerical modeling.
- 9 February 2007
- Published by Royal Society of Chemistry (RSC)
- Vol. 9 (3) , 266-274
Estimating contaminant attenuation half-lives in alluvial groundwater systems
One aspect of describing contamination in an alluvial aquifer is estimating changes in concentrations over time. A variety of statistical methods are available for assessing trends in contaminant concentrations. We present a method that extends trend analysis to include estimating the coefficients for the exponential decay equation and calculating contaminant attenuation half-lives. The conceptual model for this approach assumes that the rate of decline is proportional to the contaminant concentration in an aquifer. Consequently, the amount of time to remove a unit quantity of the contaminant inventory from an aquifer lengthens as the concentration decreases. Support for this conceptual model is demonstrated empirically with log-transformed time series of contaminant data. Equations are provided for calculating system attenuation half-lives for non-radioactive contaminants. For radioactive contaminants, the system attenuation half-life is partitioned into the intrinsic radioactive decay and the concentration reduction caused by aquifer processes. Examples are presented that provide the details of this approach. In addition to gaining an understanding of aquifer characteristics and changes in constituent concentrations, this method can be used to assess compliance with regulatory standards and to estimate the time to compliance when natural attenuation is being considered as a remediation strategy. A special application of this method is also provided that estimates the half-life of the residence time for groundwater in the aquifer by estimating the half life for a conservative contaminant that is no longer being released into the aquifer. Finally, the ratio of the half-life for groundwater residence time to the attenuation half-life for a contaminant is discussed as a system-scale retardation factor which can be used in analytical and numerical modeling.