Břetislav Mikel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Břetislav Mikel has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Martin Cizek
Institute of Scientific Instruments of the CAS, v.v.i. (Czech Republic)
6 shared publications - Josef Lazar
Institute of Scientific Instruments of the CAS, v.v.i. (Czech Republic)
5 shared publications - Ondrej Cip
Institute of Scientific Instruments of the Czech Academy of Sciences
5 shared publications - Jan Hrabina
Institute of Scientific Instruments of the CAS, v.v.i. (Czech Republic)
3 shared publications Ondrej Cip
Institute of Scientific Instruments ISI Brno CZ Czech Academy of Sciences Kralovopolska 147 612 00 Brno Czech Republic
3 shared publications- Radek Šmíd
Institute of Scientific Instruments of Academy of Sciences of Czech Republic, v.v.i., Brno 61264, Czech Republic
3 shared publications
Latest Publications
- Open Access
Monolithic interferometric modules for multi-axis coordinate positioning with sub-nanometre precision
We report on developing, characterizing, and verifying a compact, monolithic laser interferometric assembly designed for high-precision two- and three-axis displacement measurements in coordinate positioning systems. The design targets OEM integration into advanced precision motion platforms, including nanometrology instruments, semiconductor manufacturing equipment, and ultra-high vacuum (UHV) environments. Using a single laser source, the assembly integrates multiple interferometers into a monolithic L-shaped base frame, enabling sub-nanometer periodic error in X-Y motion systems while minimizing geometric and thermal instabilities. The pre-aligned and pre-adjusted architecture simplifies integration, enhances long-term stability, and ensures consistent metrological performance. The system's verification protocol employs quadrature phase analysis and systematic error metrics to characterize performance and optimise assembly. The results indicate sub-nanometer measurement capability and suggest the system's suitability for scalable implementation in advanced coordinate metrology applications.
Open AccessMonolithic interferometric modules for multi-axis coordinate positioning with sub-nanometre precision
We report on developing, characterizing, and verifying a compact, monolithic laser interferometric assembly designed for high-precision two- and three-axis displacement measurements in coordinate positioning systems. The design targets OEM integration into advanced precision motion platforms, including nanometrology instruments, semiconductor manufacturing equipment, and ultra-high vacuum (UHV) environments. Using a single laser source, the assembly integrates multiple interferometers into a monolithic L-shaped base frame, enabling sub-nanometer periodic error in X-Y motion systems while minimizing geometric and thermal instabilities. The pre-aligned and pre-adjusted architecture simplifies integration, enhances long-term stability, and ensures consistent metrological performance. The system's verification protocol employs quadrature phase analysis and systematic error metrics to characterize performance and optimise assembly. The results indicate sub-nanometer measurement capability and suggest the system's suitability for scalable implementation in advanced coordinate metrology applications.
- Open Access
Design and Characterisation of an Optical Fibre Dosimeter Based on Silica Optical Fibre and Scintillation Crystal
In nuclear power plants, particle accelerators, and other nuclear facilities, measuring the level of ionising gamma radiation is critical for the safety and management of the operation and the environment’s protection. However, in many cases, it is impossible to monitor ionising radiation directly at the required location continuously. This is typically either due to the lack of space to accommodate the entire dosimeter or in environments with high ionising radiation activity, electromagnetic radiation, and temperature, which significantly shorten electronics’ lifetime. To allow for radiation measurement in such scenarios, we designed a fibre optic dosimeter that introduces an optical fibre link to deliver the scintillation radiation between the ionising radiation sensor and the detectors. The sensors can thus be placed in space-constrained and electronically hostile locations. We used silica optical fibres that withstand high radiation doses, high temperatures, and electromagnetic interference. We use a single photon counter and a photomultiplier to detect the transmitted scintillation radiation. We have shown that selected optical fibres, combined with different scintillation materials, are suitable for measuring gamma radiation levels in hundreds of kBq. We present the architecture of the dosimeter and its experimental characterisation with several combinations of optical fibres, detectors, and scintillation crystals.
Open AccessDesign and Characterisation of an Optical Fibre Dosimeter Based on Silica Optical Fibre and Scintillation Crystal
In nuclear power plants, particle accelerators, and other nuclear facilities, measuring the level of ionising gamma radiation is critical for the safety and management of the operation and the environment’s protection. However, in many cases, it is impossible to monitor ionising radiation directly at the required location continuously. This is typically either due to the lack of space to accommodate the entire dosimeter or in environments with high ionising radiation activity, electromagnetic radiation, and temperature, which significantly shorten electronics’ lifetime. To allow for radiation measurement in such scenarios, we designed a fibre optic dosimeter that introduces an optical fibre link to deliver the scintillation radiation between the ionising radiation sensor and the detectors. The sensors can thus be placed in space-constrained and electronically hostile locations. We used silica optical fibres that withstand high radiation doses, high temperatures, and electromagnetic interference. We use a single photon counter and a photomultiplier to detect the transmitted scintillation radiation. We have shown that selected optical fibres, combined with different scintillation materials, are suitable for measuring gamma radiation levels in hundreds of kBq. We present the architecture of the dosimeter and its experimental characterisation with several combinations of optical fibres, detectors, and scintillation crystals.
- 23 December 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10142, 101420
Simultaneous transfer of optical frequency and time over 306 km long-haul optical fibre link
Optical fibre links for distributing optical frequencies and time stamps were researched and experimentally tested in the past fifteen years. They have been used mainly for stability comparison of experimental optical clocks. But recent development puts demands on a technology transfer from laboratory experiments to the real industry. The remote calibration of interrogators of Fibre Bragg Grating strain sensory networks is one of important examples. The first step of the adoption the time and frequency broadcasting should be the drop-out free long-term operation of this technology between research laboratories connected via long-haul fibre links. We present a 306 km long-haul optical fibre link between the cities of Prague and Brno in the Czech Republic where a coherent transfer of stable optical frequency and a stable time signal has been firstly demonstrated. The link between ISI CAS Brno and CESNET Prague uses an internet communication fibre where a window of 1540-1546 nm is dedicated for the coherent transfer and 1PPS signal. The link is equipped with 6 bidirectional EDFA amplifiers. The optical frequency standard based on the highly-coherent laser Koheras Adjustik working at 1540.5 nm and stabilized with a saturation absorption spectroscopy technique was used for the coherent wave transfer. The suppression of the Doppler shift induced by the optical fibre was based on an accoustooptical modulator with a servo-loop including a fast PID controller processing the beat-note frequency given by mixing of the Adjustik laser (Brno) and the reflected frequency of this laser from the far end of 306 km long-haul fibre link (Prague). We verified the Doppler shift suppression for the coherent wave with a measuring method analysing the transport delay of the 1PPS signal. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- 23 December 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10142, 101420
Simultaneous transfer of optical frequency and time over 306 km long-haul optical fibre link
Optical fibre links for distributing optical frequencies and time stamps were researched and experimentally tested in the past fifteen years. They have been used mainly for stability comparison of experimental optical clocks. But recent development puts demands on a technology transfer from laboratory experiments to the real industry. The remote calibration of interrogators of Fibre Bragg Grating strain sensory networks is one of important examples. The first step of the adoption the time and frequency broadcasting should be the drop-out free long-term operation of this technology between research laboratories connected via long-haul fibre links. We present a 306 km long-haul optical fibre link between the cities of Prague and Brno in the Czech Republic where a coherent transfer of stable optical frequency and a stable time signal has been firstly demonstrated. The link between ISI CAS Brno and CESNET Prague uses an internet communication fibre where a window of 1540-1546 nm is dedicated for the coherent transfer and 1PPS signal. The link is equipped with 6 bidirectional EDFA amplifiers. The optical frequency standard based on the highly-coherent laser Koheras Adjustik working at 1540.5 nm and stabilized with a saturation absorption spectroscopy technique was used for the coherent wave transfer. The suppression of the Doppler shift induced by the optical fibre was based on an accoustooptical modulator with a servo-loop including a fast PID controller processing the beat-note frequency given by mixing of the Adjustik laser (Brno) and the reflected frequency of this laser from the far end of 306 km long-haul fibre link (Prague). We verified the Doppler shift suppression for the coherent wave with a measuring method analysing the transport delay of the 1PPS signal. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
- Open Access
Noise Suppression on the Tunable Laser for Precise Cavity Length Displacement Measurement
The absolute distance between the mirrors of a Fabry-Perot cavity with a spacer from an ultra low expansion material was measured by an ultra wide tunable laser diode. The DFB laser diode working at 1542 nm with 1.5 MHz linewidth and 2 nm tuning range has been suppressed with an unbalanced heterodyne fiber interferometer. The frequency noise of laser has been suppressed by 40 dB across the Fourier frequency range 30–300 Hz and by 20 dB up to 4 kHz and the linewidth of the laser below 300 kHz. The relative resolution of the measurement was that corresponds to 0.3 nm (sub-nm) for 0.178 m long cavity with ability of displacement measurement of 0.5 mm.Open AccessNoise Suppression on the Tunable Laser for Precise Cavity Length Displacement Measurement
The absolute distance between the mirrors of a Fabry-Perot cavity with a spacer from an ultra low expansion material was measured by an ultra wide tunable laser diode. The DFB laser diode working at 1542 nm with 1.5 MHz linewidth and 2 nm tuning range has been suppressed with an unbalanced heterodyne fiber interferometer. The frequency noise of laser has been suppressed by 40 dB across the Fourier frequency range 30–300 Hz and by 20 dB up to 4 kHz and the linewidth of the laser below 300 kHz. The relative resolution of the measurement was that corresponds to 0.3 nm (sub-nm) for 0.178 m long cavity with ability of displacement measurement of 0.5 mm. - Open Access
Frequency Noise Suppression of a Single Mode Laser with an Unbalanced Fiber Interferometer for Subnanometer Interferometry
We present a method of noise suppression of laser diodes by an unbalanced Michelson fiber interferometer. The unstabilized laser source is represented by compact planar waveguide external cavity laser module, ORIONTM (Redfern Integrated Optics, Inc.), working at 1540.57 nm with a 1.5-kHz linewidth. We built up the unbalanced Michelson interferometer with a 2.09 km-long arm based on the standard telecommunication single-mode fiber (SMF-28) spool to suppress the frequency noise by the servo-loop control by 20 dB to 40 dB within the Fourier frequency range, remaining the tuning range of the laser frequency.
Open AccessFrequency Noise Suppression of a Single Mode Laser with an Unbalanced Fiber Interferometer for Subnanometer Interferometry
We present a method of noise suppression of laser diodes by an unbalanced Michelson fiber interferometer. The unstabilized laser source is represented by compact planar waveguide external cavity laser module, ORIONTM (Redfern Integrated Optics, Inc.), working at 1540.57 nm with a 1.5-kHz linewidth. We built up the unbalanced Michelson interferometer with a 2.09 km-long arm based on the standard telecommunication single-mode fiber (SMF-28) spool to suppress the frequency noise by the servo-loop control by 20 dB to 40 dB within the Fourier frequency range, remaining the tuning range of the laser frequency.
- Open Access
Two-Stage System Based on a Software-Defined Radio for Stabilizing of Optical Frequency Combs in Long-Term Experiments
A passive optical resonator is a special sensor used for measurement of lengths on the nanometer and sub-nanometer scale. A stabilized optical frequency comb can provide an ultimate reference for measuring the wavelength of a tunable laser locked to the optical resonator. If we lock the repetition and offset frequencies of the comb to a high-grade radiofrequency (RF) oscillator its relative frequency stability is transferred from the RF to the optical frequency domain. Experiments in the field of precise length metrology of low-expansion materials are usually of long-term nature so it is required that the optical frequency comb stay in operation for an extended period of time. The optoelectronic closed-loop systems used for stabilization of combs are usually based on traditional analog electronic circuits processing signals from photodetectors. From an experimental point of view, these setups are very complicated and sensitive to ambient conditions, especially in the optical part, therefore maintaining long-time operation is not easy. The research presented in this paper deals with a novel approach based on digital signal processing and a software-defined radio. We describe digital signal processing algorithms intended for keeping the femtosecond optical comb in a long-time stable operation. This need arose during specialized experiments involving measurements of optical frequencies of tunable continuous-wave lasers. The resulting system is capable of keeping the comb in lock for an extensive period of time (8 days or more) with the relative stability better than 1.6 × 10−11.
Open AccessTwo-Stage System Based on a Software-Defined Radio for Stabilizing of Optical Frequency Combs in Long-Term Experiments
A passive optical resonator is a special sensor used for measurement of lengths on the nanometer and sub-nanometer scale. A stabilized optical frequency comb can provide an ultimate reference for measuring the wavelength of a tunable laser locked to the optical resonator. If we lock the repetition and offset frequencies of the comb to a high-grade radiofrequency (RF) oscillator its relative frequency stability is transferred from the RF to the optical frequency domain. Experiments in the field of precise length metrology of low-expansion materials are usually of long-term nature so it is required that the optical frequency comb stay in operation for an extended period of time. The optoelectronic closed-loop systems used for stabilization of combs are usually based on traditional analog electronic circuits processing signals from photodetectors. From an experimental point of view, these setups are very complicated and sensitive to ambient conditions, especially in the optical part, therefore maintaining long-time operation is not easy. The research presented in this paper deals with a novel approach based on digital signal processing and a software-defined radio. We describe digital signal processing algorithms intended for keeping the femtosecond optical comb in a long-time stable operation. This need arose during specialized experiments involving measurements of optical frequencies of tunable continuous-wave lasers. The resulting system is capable of keeping the comb in lock for an extensive period of time (8 days or more) with the relative stability better than 1.6 × 10−11.
- Open Access
Novel Principle of Contactless Gauge Block Calibration
In this paper, a novel principle of contactless gauge block calibration is presented. The principle of contactless gauge block calibration combines low-coherence interferometry and laser interferometry. An experimental setup combines Dowell interferometer and Michelson interferometer to ensure a gauge block length determination with direct traceability to the primary length standard. By monitoring both gauge block sides with a digital camera gauge block 3D surface measurements are possible too. The principle presented is protected by the Czech national patent No. 302948.
Open AccessNovel Principle of Contactless Gauge Block Calibration
In this paper, a novel principle of contactless gauge block calibration is presented. The principle of contactless gauge block calibration combines low-coherence interferometry and laser interferometry. An experimental setup combines Dowell interferometer and Michelson interferometer to ensure a gauge block length determination with direct traceability to the primary length standard. By monitoring both gauge block sides with a digital camera gauge block 3D surface measurements are possible too. The principle presented is protected by the Czech national patent No. 302948.
- 23 November 2009
- Published by Springer Nature
- p. 1-4
Multiwavelength laser interferometry
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6606, 660607
Design and fabrication of fiber Bragg gratings for vertical cavity surface emitting laser diodes
We simulated chirped and apodized fiber Bragg gratings (fiber gratings with modulation of the amplitude and with modulation of the spacing) the same as uniform fiber gratings. Results of our simulations are presented. Apodization of fiber Bragg gratings (FBG) has many advantages in comparison to other types of FBGs. Main improvement is suppressing of the side lobes in the grating spectral properties. The difference of side lobes suppression for uniform and Gaussian apodized grating is more than 110dB. On the basis of these results we designed a special fiber Bragg grating with apodization especially for using to stabilize semiconductor lasers for high precision laser applications with central wavelength 760nm. We present application of methods for calculation of parameters of apodized fiber Bragg gratings (FBG). We used combination of methods based on layered dielectric media (LDM) and the transfer matrix. On the contrary to the other calculation techniques the LDM method is based on sequence of thin films of dielectric media assembled in the direction of wave propagation. The combination of the LDM method and the transfer matrix method can be used to the calculation of arbitrary fiber gratings with high precision. For this designed apodized FBG we calculated the phase mask to manufacture by interference patterns. The phase mask and the fixation bottom of the fiber were made by e-beam lithography to achieve highly precise stability during manufacturing. We present the set-up of this system for writing FBG by pulsed UV laser with wavelength 266nm. Measurement of commercially available FBG with comparison to our calculated FBG is presented.
- 16 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6606, 660607
Design and fabrication of fiber Bragg gratings for vertical cavity surface emitting laser diodes
We simulated chirped and apodized fiber Bragg gratings (fiber gratings with modulation of the amplitude and with modulation of the spacing) the same as uniform fiber gratings. Results of our simulations are presented. Apodization of fiber Bragg gratings (FBG) has many advantages in comparison to other types of FBGs. Main improvement is suppressing of the side lobes in the grating spectral properties. The difference of side lobes suppression for uniform and Gaussian apodized grating is more than 110dB. On the basis of these results we designed a special fiber Bragg grating with apodization especially for using to stabilize semiconductor lasers for high precision laser applications with central wavelength 760nm. We present application of methods for calculation of parameters of apodized fiber Bragg gratings (FBG). We used combination of methods based on layered dielectric media (LDM) and the transfer matrix. On the contrary to the other calculation techniques the LDM method is based on sequence of thin films of dielectric media assembled in the direction of wave propagation. The combination of the LDM method and the transfer matrix method can be used to the calculation of arbitrary fiber gratings with high precision. For this designed apodized FBG we calculated the phase mask to manufacture by interference patterns. The phase mask and the fixation bottom of the fiber were made by e-beam lithography to achieve highly precise stability during manufacturing. We present the set-up of this system for writing FBG by pulsed UV laser with wavelength 266nm. Measurement of commercially available FBG with comparison to our calculated FBG is presented.