Nan Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nan Xiao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Shuxiang Guo
Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, China
7 shared publications - Baofeng Gao
Faculty of Engineering, Kagawa University, 2217-20 Hayashi-cho, Takamatsu, Kagawa 761-0396, Japan
4 shared publications - Zhibin Song
Faculty of Engineering, Kagawa University, 2217-20 Hayashi-cho, Takamatsu, Kagawa 761-0396, Japan
3 shared publications - Liwei Shi
Department of Intelligent Mechanical Systems Engineering, Kagawa University, Hayashi-cho, Takamatsu 761-0369, Japan
2 shared publications - Takashi Tamiya
Department of Neurosurgery, Kagawa University Hospital, 1750-1 Ikenobe, Miki, Kita, Kagawa 761-0793, Japan
2 shared publications Jian Guo
1 shared publication
Latest Publications
- 1 October 2013
- Published by Bentham Science Publishers Ltd. in Neuroscience and Biomedical Engineering
- Vol. 666 (666) , 1-5
Clamping Force Evaluation For A Robotic Catheter Navigation System
- 1 October 2013
- Published by Bentham Science Publishers Ltd. in Neuroscience and Biomedical Engineering
- Vol. 666 (666) , 1-5
Clamping Force Evaluation For A Robotic Catheter Navigation System
- 10 March 2013
- Published by Springer Nature in Journal of Micro and Bio Robotics
- Vol. 8 (3-4) , 133-143
Evaluating performance of a novel developed robotic catheter manipulating system
- 10 March 2013
- Published by Springer Nature in Journal of Micro and Bio Robotics
- Vol. 8 (3-4) , 133-143
Evaluating performance of a novel developed robotic catheter manipulating system
- Open Access
A Novel Soft Biomimetic Microrobot with Two Motion Attitudes
A variety of microrobots have commonly been used in the fields of biomedical engineering and underwater operations during the last few years. Thanks to their compact structure, low driving power, and simple control systems, microrobots can complete a variety of underwater tasks, even in limited spaces. To accomplish our objectives, we previously designed several bio-inspired underwater microrobots with compact structure, flexibility, and multi-functionality, using ionic polymer metal composite (IPMC) actuators. To implement high-position precision for IPMC legs, in the present research, we proposed an electromechanical model of an IPMC actuator and analysed the deformation and actuating force of an equivalent IPMC cantilever beam, which could be used to design biomimetic legs, fingers, or fins for an underwater microrobot. We then evaluated the tip displacement of an IPMC actuator experimentally. The experimental deflections fit the theoretical values very well when the driving frequency was larger than 1 Hz. To realise the necessary multi-functionality for adapting to complex underwater environments, we introduced a walking biomimetic microrobot with two kinds of motion attitudes: a lying state and a standing state. The microrobot uses eleven IPMC actuators to move and two shape memory alloy (SMA) actuators to change its motion attitude. In the lying state, the microrobot implements stick-insect-inspired walking/rotating motion, fish-like swimming motion, horizontal grasping motion, and floating motion. In the standing state, it implements inchworm-inspired crawling motion in two horizontal directions and grasping motion in the vertical direction. We constructed a prototype of this biomimetic microrobot and evaluated its walking, rotating, and floating speeds experimentally. The experimental results indicated that the robot could attain a maximum walking speed of 3.6 mm/s, a maximum rotational speed of 9°/s, and a maximum floating speed of 7.14 mm/s. Obstacle-avoidance and swimming experiments were also carried out to demonstrate its multi-functionality.
Open AccessA Novel Soft Biomimetic Microrobot with Two Motion Attitudes
A variety of microrobots have commonly been used in the fields of biomedical engineering and underwater operations during the last few years. Thanks to their compact structure, low driving power, and simple control systems, microrobots can complete a variety of underwater tasks, even in limited spaces. To accomplish our objectives, we previously designed several bio-inspired underwater microrobots with compact structure, flexibility, and multi-functionality, using ionic polymer metal composite (IPMC) actuators. To implement high-position precision for IPMC legs, in the present research, we proposed an electromechanical model of an IPMC actuator and analysed the deformation and actuating force of an equivalent IPMC cantilever beam, which could be used to design biomimetic legs, fingers, or fins for an underwater microrobot. We then evaluated the tip displacement of an IPMC actuator experimentally. The experimental deflections fit the theoretical values very well when the driving frequency was larger than 1 Hz. To realise the necessary multi-functionality for adapting to complex underwater environments, we introduced a walking biomimetic microrobot with two kinds of motion attitudes: a lying state and a standing state. The microrobot uses eleven IPMC actuators to move and two shape memory alloy (SMA) actuators to change its motion attitude. In the lying state, the microrobot implements stick-insect-inspired walking/rotating motion, fish-like swimming motion, horizontal grasping motion, and floating motion. In the standing state, it implements inchworm-inspired crawling motion in two horizontal directions and grasping motion in the vertical direction. We constructed a prototype of this biomimetic microrobot and evaluated its walking, rotating, and floating speeds experimentally. The experimental results indicated that the robot could attain a maximum walking speed of 3.6 mm/s, a maximum rotational speed of 9°/s, and a maximum floating speed of 7.14 mm/s. Obstacle-avoidance and swimming experiments were also carried out to demonstrate its multi-functionality.
- Open Access
Implementation of Human-Machine Synchronization Control for Active Rehabilitation Using an Inertia Sensor
According to neuro-rehabilitation practice, active training is effective for mild stroke patients, which means these patients are able to recovery effective when they perform the training to overcome certain resistance by themselves. Therefore, for rehabilitation devices without backdrivability, implementation of human-machine synchronization is important and a precondition to perform active training. In this paper, a method to implement this precondition is proposed and applied in a user’s performance of elbow flexions and extensions when he wore an upper limb exoskeleton rehabilitation device (ULERD), which is portable, wearable and non-backdrivable. In this method, an inertia sensor is adapted to detect the motion of the user’s forearm. In order to get a smooth value of the velocity of the user’s forearm, an adaptive weighted average filtering is applied. On the other hand, to obtain accurate tracking performance, a double close-loop control is proposed to realize real-time and stable tracking. Experiments have been conducted to prove that these methods are effective and feasible for active rehabilitation.
Open AccessImplementation of Human-Machine Synchronization Control for Active Rehabilitation Using an Inertia Sensor
According to neuro-rehabilitation practice, active training is effective for mild stroke patients, which means these patients are able to recovery effective when they perform the training to overcome certain resistance by themselves. Therefore, for rehabilitation devices without backdrivability, implementation of human-machine synchronization is important and a precondition to perform active training. In this paper, a method to implement this precondition is proposed and applied in a user’s performance of elbow flexions and extensions when he wore an upper limb exoskeleton rehabilitation device (ULERD), which is portable, wearable and non-backdrivable. In this method, an inertia sensor is adapted to detect the motion of the user’s forearm. In order to get a smooth value of the velocity of the user’s forearm, an adaptive weighted average filtering is applied. On the other hand, to obtain accurate tracking performance, a double close-loop control is proposed to realize real-time and stable tracking. Experiments have been conducted to prove that these methods are effective and feasible for active rehabilitation.
- 25 September 2012
- Published by Springer Nature
- p. 175-190
A Novel Robot-Assisted Catheter Surgery System with Force Feedback
- 25 September 2012
- Published by Springer Nature
- p. 175-190
A Novel Robot-Assisted Catheter Surgery System with Force Feedback
- Open Access
- 23 May 2012
- Published by IntechOpen
Robotic Catheter Operating Systems for Endovascular Neurosurgery
- 23 May 2012
- Published by IntechOpen
Open AccessRobotic Catheter Operating Systems for Endovascular Neurosurgery
- 1 January 2012
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 27 (2)
MODELLING AND CONTROL OF A KIND OF PARALLEL MECHANISM DRIVEN BY PIEZOELECTRIC ACTUATORS
- 1 January 2012
- Published by ACTA Press in International Journal of Robotics and Automation
- Vol. 27 (2)
MODELLING AND CONTROL OF A KIND OF PARALLEL MECHANISM DRIVEN BY PIEZOELECTRIC ACTUATORS