Juozas Kulys
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Juozas Kulys has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Romas Baronas
Faculty of Mathematics and Informatics, Institute of Computer Science, Vilnius University, Didlaukio 47, LT-08303 Vilnius, Lithuania
5 shared publications Irina Bratkovskaja
Vilnius University, Institute of Biochemistry, Mokslininku 12, 08662 Vilnius, Lithuania tel: 37052729176; fax: 37052729196
2 shared publications- Liucija Marcinkevičienė
Institute of Biochemistry Life Sciences Center, Vilnius University Saulėtekio al. 7 LT-10257 Vilnius Lithuania
2 shared publications - Rolandas Meškys
Department of Molecular Microbiology and Biotechnology, Institute of Biochemistry, Life Sciences Center, Vilnius University, 10257 Vilnius, Lithuania
2 shared publications - Vytautas Ašeris
Vilnius University
2 shared publications - Algirdas Lančinskas
Institute of Data Science and Digital Technologies, Vilnius University, Vilnius, Lithuania
1 shared publication
Latest Publications
- 15 January 2018
- Published by Wiley in ChemCatChem
- Vol. 10 (5) , 971-974
Wiring Gold Nanoparticles and Redox Enzymes: A Self‐Sufficient Nanocatalyst for the Direct Oxidation of Carbohydrates with Molecular Oxygen
The development of artificial nanocatalysts, especially those incorporating the highly active biocatalysts (enzymes) present in nature, is a rapidly developing field in nanocatalysis and nanomaterials science. Dehydrogenases are exceptionally attractive, as they catalyze the oxidation of various cheap/common substrates to more expensive and desired products. However, their use in sustainable catalysis and/or their incorporation in advanced nanomaterials with catalytic functions are limited owing to one immense problem that can be formulated as a question: how can the electrons received from the oxidized substrate be removed? Here, a solution to this problem is demonstrated: we designed a unique nanomaterial composed of two redox enzymes (nonspecific glucose dehydrogenase and oxygen‐reducing laccase) and gold nanoparticles. Both enzymes were wired through the gold nanoparticles (10 nm) and direct electrochemical “communication” was achieved, allowing electron transfer from the redox center of glucose dehydrogenase to a copper center of laccase. As a result, self‐sufficient nanocatalysts were synthesized and shown to oxidize various carbohydrates directly with molecular oxygen.
- 15 January 2018
- Published by Wiley in ChemCatChem
- Vol. 10 (5) , 971-974
Wiring Gold Nanoparticles and Redox Enzymes: A Self‐Sufficient Nanocatalyst for the Direct Oxidation of Carbohydrates with Molecular Oxygen
The development of artificial nanocatalysts, especially those incorporating the highly active biocatalysts (enzymes) present in nature, is a rapidly developing field in nanocatalysis and nanomaterials science. Dehydrogenases are exceptionally attractive, as they catalyze the oxidation of various cheap/common substrates to more expensive and desired products. However, their use in sustainable catalysis and/or their incorporation in advanced nanomaterials with catalytic functions are limited owing to one immense problem that can be formulated as a question: how can the electrons received from the oxidized substrate be removed? Here, a solution to this problem is demonstrated: we designed a unique nanomaterial composed of two redox enzymes (nonspecific glucose dehydrogenase and oxygen‐reducing laccase) and gold nanoparticles. Both enzymes were wired through the gold nanoparticles (10 nm) and direct electrochemical “communication” was achieved, allowing electron transfer from the redox center of glucose dehydrogenase to a copper center of laccase. As a result, self‐sufficient nanocatalysts were synthesized and shown to oxidize various carbohydrates directly with molecular oxygen.
- 1 April 2015
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 30, 135-139
Laccase-catalyzed bisphenol A oxidation in the presence of 10-propyl sulfonic acid phenoxazine
- 1 April 2015
- Published by Elsevier in Journal of Environmental Sciences
- Vol. 30, 135-139
Laccase-catalyzed bisphenol A oxidation in the presence of 10-propyl sulfonic acid phenoxazine
- Open Access
Effect of Diffusion Limitations on Multianalyte Determination from Biased Biosensor Response
The optimization-based quantitative determination of multianalyte concentrations from biased biosensor responses is investigated under internal and external diffusion-limited conditions. A computational model of a biocatalytic amperometric biosensor utilizing a mono-enzyme-catalyzed (nonspecific) competitive conversion of two substrates was used to generate pseudo-experimental responses to mixtures of compounds. The influence of possible perturbations of the biosensor signal, due to a white noise- and temperature-induced trend, on the precision of the concentration determination has been investigated for different configurations of the biosensor operation. The optimization method was found to be suitable and accurate enough for the quantitative determination of the concentrations of the compounds from a given biosensor transient response. The computational experiments showed a complex dependence of the precision of the concentration estimation on the relative thickness of the outer diffusion layer, as well as on whether the biosensor operates under diffusion- or kinetics-limited conditions. When the biosensor response is affected by the induced exponential trend, the duration of the biosensor action can be optimized for increasing the accuracy of the quantitative analysis.
Open AccessEffect of Diffusion Limitations on Multianalyte Determination from Biased Biosensor Response
The optimization-based quantitative determination of multianalyte concentrations from biased biosensor responses is investigated under internal and external diffusion-limited conditions. A computational model of a biocatalytic amperometric biosensor utilizing a mono-enzyme-catalyzed (nonspecific) competitive conversion of two substrates was used to generate pseudo-experimental responses to mixtures of compounds. The influence of possible perturbations of the biosensor signal, due to a white noise- and temperature-induced trend, on the precision of the concentration determination has been investigated for different configurations of the biosensor operation. The optimization method was found to be suitable and accurate enough for the quantitative determination of the concentrations of the compounds from a given biosensor transient response. The computational experiments showed a complex dependence of the precision of the concentration estimation on the relative thickness of the outer diffusion layer, as well as on whether the biosensor operates under diffusion- or kinetics-limited conditions. When the biosensor response is affected by the induced exponential trend, the duration of the biosensor action can be optimized for increasing the accuracy of the quantitative analysis.
- 9 May 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (6) , 1491-1496
Electrochemical Peroxidase‐Catalase Clark‐Type Biosensor: Computed and Experimental Response
A bioelectrode containing immobilized catalase and peroxidase was built using a Clark‐type oxygen electrode. The bioelectrode responded to hydrogen peroxide (H2O2) as well as to acetaminophen (Ac). The sensitivity of the bioelectrode for H2O2 was 0.35 mM O2/mM H2O2 and for Ac it was 0.23–1.05 µM O2/µM Ac at pH 6.6 and 25 °C. The limit of detection of Ac varied from 12 to 44 µM. The half‐time of the bioelectrode response to hydrogen peroxide was 36 s. The modeling of the bioelectrode action was performed digitally at transition and steady‐state conditions using finite difference technique. The calculated half‐time of the bioelectrode response to hydrogen peroxide was 53 % larger and the steady‐state response 11 % less than experimentally determined. The response to Ac was 2–3 times smaller in comparison to the experimental values. The calculated response change correlated with the experimentally determined when the catalase and peroxidase concentrations in the biocatalytical membrane changed 3–4 orders of magnitude. The simulations of the bioelectrode response revealed that the bioelectrode acts in diffusion limiting conditions at almost all enzymes concentrations. The model appears to be promising for optimization of the bioelectrode response.
- 9 May 2013
- Published by Wiley in Electroanalysis
- Vol. 25 (6) , 1491-1496
Electrochemical Peroxidase‐Catalase Clark‐Type Biosensor: Computed and Experimental Response
A bioelectrode containing immobilized catalase and peroxidase was built using a Clark‐type oxygen electrode. The bioelectrode responded to hydrogen peroxide (H2O2) as well as to acetaminophen (Ac). The sensitivity of the bioelectrode for H2O2 was 0.35 mM O2/mM H2O2 and for Ac it was 0.23–1.05 µM O2/µM Ac at pH 6.6 and 25 °C. The limit of detection of Ac varied from 12 to 44 µM. The half‐time of the bioelectrode response to hydrogen peroxide was 36 s. The modeling of the bioelectrode action was performed digitally at transition and steady‐state conditions using finite difference technique. The calculated half‐time of the bioelectrode response to hydrogen peroxide was 53 % larger and the steady‐state response 11 % less than experimentally determined. The response to Ac was 2–3 times smaller in comparison to the experimental values. The calculated response change correlated with the experimentally determined when the catalase and peroxidase concentrations in the biocatalytical membrane changed 3–4 orders of magnitude. The simulations of the bioelectrode response revealed that the bioelectrode acts in diffusion limiting conditions at almost all enzymes concentrations. The model appears to be promising for optimization of the bioelectrode response.
- 1 January 2013
- Published by Vilnius University Press in Informatica
- Vol. 24 (4) , 505-521
Computational Modeling of Bienzyme Biosensor with Different Initial and Boundary Conditions
- 1 January 2013
- Published by Vilnius University Press in Informatica
- Vol. 24 (4) , 505-521
Computational Modeling of Bienzyme Biosensor with Different Initial and Boundary Conditions
- 1 October 2012
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 685, 63-71
Modelling the biosensor utilising parallel substrates conversion
- 1 October 2012
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 685, 63-71
Modelling the biosensor utilising parallel substrates conversion
- Open Access
Modelling Carbon Nanotubes-Based Mediatorless Biosensor
This paper presents a mathematical model of carbon nanotubes-based mediatorless biosensor. The developed model is based on nonlinear non-stationary reaction-diffusion equations. The model involves four layers (compartments): a layer of enzyme solution entrapped on a terylene membrane, a layer of the single walled carbon nanotubes deposited on a perforated membrane, and an outer diffusion layer. The biosensor response and sensitivity are investigated by changing the model parameters with a special emphasis on the mediatorless transfer of the electrons in the layer of the enzyme-loaded carbon nanotubes. The numerical simulation at transient and steady state conditions was carried out using the finite difference technique. The mathematical model and the numerical solution were validated by experimental data. The obtained agreement between the simulation results and the experimental data was admissible at different concentrations of the substrate.
Open AccessModelling Carbon Nanotubes-Based Mediatorless Biosensor
This paper presents a mathematical model of carbon nanotubes-based mediatorless biosensor. The developed model is based on nonlinear non-stationary reaction-diffusion equations. The model involves four layers (compartments): a layer of enzyme solution entrapped on a terylene membrane, a layer of the single walled carbon nanotubes deposited on a perforated membrane, and an outer diffusion layer. The biosensor response and sensitivity are investigated by changing the model parameters with a special emphasis on the mediatorless transfer of the electrons in the layer of the enzyme-loaded carbon nanotubes. The numerical simulation at transient and steady state conditions was carried out using the finite difference technique. The mathematical model and the numerical solution were validated by experimental data. The obtained agreement between the simulation results and the experimental data was admissible at different concentrations of the substrate.
- Open Access
Modelling of Amperometric Biosensor Used for Synergistic Substrates Determination
In this paper the operation of an amperometric biosensor producing a chemically amplified signal is modelled numerically. The chemical amplification is achieved by using synergistic substrates. The model is based on non-stationary reaction-diffusion equations. The model involves three layers (compartments): a layer of enzyme solution entrapped on the electrode surface, a dialysis membrane covering the enzyme layer and an outer diffusion layer which is modelled by the Nernst approach. The equation system is solved numerically by using the finite difference technique. The biosensor response and sensitivity are investigated by altering the model parameters influencing the enzyme kinetics as well as the mass transport by diffusion. The biosensor action was analyzed with a special emphasis to the effect of the chemical amplification. The simulation results qualitatively explain and confirm the experimentally observed effect of the synergistic substrates conversion on the biosensor response.
Open AccessModelling of Amperometric Biosensor Used for Synergistic Substrates Determination
In this paper the operation of an amperometric biosensor producing a chemically amplified signal is modelled numerically. The chemical amplification is achieved by using synergistic substrates. The model is based on non-stationary reaction-diffusion equations. The model involves three layers (compartments): a layer of enzyme solution entrapped on the electrode surface, a dialysis membrane covering the enzyme layer and an outer diffusion layer which is modelled by the Nernst approach. The equation system is solved numerically by using the finite difference technique. The biosensor response and sensitivity are investigated by altering the model parameters influencing the enzyme kinetics as well as the mass transport by diffusion. The biosensor action was analyzed with a special emphasis to the effect of the chemical amplification. The simulation results qualitatively explain and confirm the experimentally observed effect of the synergistic substrates conversion on the biosensor response.
- 12 January 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (2) , 273-277
Glucose Dehydrogenase Based Bioelectrode Utilizing a Synergistic Scheme of Substrate Conversion
- 12 January 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (2) , 273-277
Glucose Dehydrogenase Based Bioelectrode Utilizing a Synergistic Scheme of Substrate Conversion