HHHong-Yi Huang

Hong-Yi Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hong-Yi Huang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A 2.5 mW/ch, 50 Mcps, 10-Analog Channel, Adaptively Biased Read-Out Front-End IC With Low Intrinsic Timing Resolution for Single-Photon Time-of-Flight PET Applications With Time-Dependent Noise Analysis in 90 nm CMOS

    by Hugo Cruz, Hong-Yi Huang, Ching-Hsing Luo, Shuenn-Yuh Lee

    This paper presents a 10-channel time-of-flight application-specific integrated circuit (ASIC) for positron emission tomography in a 90 nm standard CMOS process. To overcome variations in channel-to-channel timing resolution caused by mismatch and process variations, adaptive biases and a digital-to-analog converter (DAC) are utilized. The main contributions of this work are as follows. First, multistage architectures reduce the total power consumption, and detection bandwidths of analog preamplifiers and comparators are increased to 1 and 1.5 GHz, respectively, relative to those in previous studies. Second, a total intrinsic electronic timing resolution of 9.71 ps root-mean-square (RMS) is achieved (13.88 ps peak and 11.8 ps average of the 10 channels in 5 ASICs). Third, the proposed architecture reduces variations in channel-to-channel timing resolution to 2.6 bits (equivalent to 4.17 ps RMS) by calibrating analog comparator threshold levels. A 181.5 ps full-width-at-half-maximum timing resolution is measured with an avalanche photo diode and a laser setup. The power consumption is 2.5 mW using 0.5 and 1.2 V power supplies. The proposed ASIC is implemented in a 90 nm TSMC CMOS process with a total area of 3.3 mm × 2.7 mm.


  • Open Access

    A Self-Testing Platform with a Foreground Digital Calibration Technique for SAR ADCs

    by Yi-Hsiang Juan, Hong-Yi Huang, Shuenn-Yuh Lee, Shin-Chi Lai, Wen-Ho Juang, Ching-Hsing Luo

    This study presents a self-testing platform with a foreground digital calibration technique for successive approximation register (SAR) analog-to-digital converters (ADCs). A high-accuracy digital-to-analog converter (DAC) with digital control is used for the proposed self-testing platform to generate the sinusoidal test signal. This signal is then implemented using an Arduino board, and the clock signal is generated to test the ADCs. In addition, fast Fourier transform and recursive discrete Fourier transform (RDFT) processors are adopted for dynamic performance evaluation and calibration of the ADCs. The third harmonic distortion caused by the non-linearity of the track-and-hold circuit, the mismatch of the DAC capacitor array, and the direct current (DC) offset of the comparator can be calculated using the processors to improve the ADC performance. The advantages of the proposed platform include its low cost, high integration, and no need for an extra analogy compensation circuit to deal with calibration. In this work a 12 bit SAR ADC and an RDFT processor are used in the Taiwan Semiconductor Manufacturing Co., Ltd. (TSMC) 0.18 μm standard complementary metal–oxide–semiconductor (CMOS) process with a sampling rate of 18.75 kS/s to validate the proposed method. The measurement results show that the signal-to-noise and distortion ratio is 55.07 dB before calibration and 61.35 dB after calibration.


  • All digital pulsewidth control loop

    by Hong-Yi Huang, Shiun-Dian Jan, Ruei-Iun Pu

    This work presents an all-digital pulsewidth control loop (ADPWCL). The proposed system accepts a wide range of input duty cycles and performs a fast correction to the target output pulsewidth. An all-digital delay-locked loop (DLL) with fast locking time using a simplified time to digital converter and a new differential two-step delay element is proposed. The area of the delay element is much smaller than that in conventional designs, while having the same delay range. A test chip is verified in a 0.18-µm CMOS process. The measured duty cycle ranges from 4% to 98% with 7-bit resolution.


  • High-gain, high-bandwidth, rail-to-rail, constant-gmCMOS operational amplifier

    by Hong-Yi Huang, Bo-Ruei Wang

    This study presents a high-gain, high-bandwidth, constant-gm , rail-to-rail operational amplifier (op-amp). The constant transconductance is improved with a source-to-bulk bias control of an input pair. A source degeneration scheme is also adapted to the output stage for receiving wide input range without degradation of the gain. Additionally, several compensation schemes are employed to enhance the stability. A test chip is fabricated in a 0.18 µm complementary metal-oxide semiconductor process. The active area of the op-amp is 181 × 173 µm2 and it consumes a power of 2.41 mW at a supply voltage of 1.8 V. The op-amp achieves a dc gain of 94.3 dB and a bandwidth of 45 MHz when the output capacitive load is connected to an effective load of 42.5 pF. A class-AB output stage combining a slew rate (SR) boost circuit provides a sinking current of 6 mA and an SR of 17 V/µs.


  • Open Access

    An Efficient Micro Control Unit with a Reconfigurable Filter Design for Wireless Body Sensor Networks (WBSNs)

    by Chiung-An Chen, Shih-Lun Chen, Hong-Yi Huang, Ching-Hsing Luo

    In this paper, a low-cost, low-power and high performance micro control unit (MCU) core is proposed for wireless body sensor networks (WBSNs). It consists of an asynchronous interface, a register bank, a reconfigurable filter, a slop-feature forecast, a lossless data encoder, an error correct coding (ECC) encoder, a UART interface, a power management (PWM), and a multi-sensor controller. To improve the system performance and expansion abilities, the asynchronous interface is added for handling signal exchanges between different clock domains. To eliminate the noise of various bio-signals, the reconfigurable filter is created to provide the functions of average, binomial and sharpen filters. The slop-feature forecast and the lossless data encoder is proposed to reduce the data of various biomedical signals for transmission. Furthermore, the ECC encoder is added to improve the reliability for the wireless transmission and the UART interface is employed the proposed design to be compatible with wireless devices. For long-term healthcare monitoring application, a power management technique is developed for reducing the power consumption of the WBSN system. In addition, the proposed design can be operated with four different bio-sensors simultaneously. The proposed design was successfully tested with a FPGA verification board. The VLSI architecture of this work contains 7.67-K gate counts and consumes the power of 5.8 mW or 1.9 mW at 100 MHz or 133 MHz processing rate using a TSMC 0.18 μm or 0.13 μm CMOS process. Compared with previous techniques, this design achieves higher performance, more functions, more flexibility and higher compatibility than other micro controller designs.


  • Open Access

    Real-Time Telemetry System for Amperometric and Potentiometric Electrochemical Sensors

    by Wei-Song Wang, Hong-Yi Huang, Shu-Chun Chen, Kuo-Chuan Ho, Chia-Yu Lin, Tse-Chuan Chou, Chih-Hsien Hu, Wen-Fong Wang, Cheng-Feng Wu, Ching-Hsing Luo

    A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC), a microcontroller unit (MCU), a graphical user interface (GUI), and a radio frequency (RF) transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA) to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA). The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR) greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment), a small size of 5.6 cm × 8.7 cm, high portability, and high integration.


  • A 6-GHz Built-in Jitter Measurement Circuit Using Multiphase Sampler

    by Kuo-Hsing Cheng, Jen-Chieh Liu, Hong-Yi Huang, Yu-Liang Li, Yong-Jhen Jhu

    This brief presents a 6-GHz built-in jitter measurement (BIJM) with the time amplifier (TA) and the multiphase sampler (MPS) to achieve a 1-ps timing resolution. The proposed MPS can reduce the area, and the TA can extend the total timing resolution of BIJM. The self-referenced circuit with the autocalibration technique can eliminate the process variations and create a reference clock being a sampled signal. Using the calibration technique, the gain variation of TA and the timing resolution variation of MPS can be aligned to achieve a 1-ps timing resolution. The sense amplifier delay flip-flop uses the bulk input to reduce the measured error. The BIJM is fabricated by a 90-nm CMOS process. The core area of BIJM is 130 μm × 200 μm, and the power consumption is 20.4 mW with the I/O buffers.


  • Open Access

    An Asynchronous Multi-Sensor Micro Control Unit for Wireless Body Sensor Networks (WBSNs)

    by Chiung-An Chen, Shih-Lun Chen, Hong-Yi Huang, Ching-Hsing Luo

    In this work, an asynchronous multi-sensor micro control unit (MCU) core is proposed for wireless body sensor networks (WBSNs). It consists of asynchronous interfaces, a power management unit, a multi-sensor controller, a data encoder (DE), and an error correct coder (ECC). To improve the system performance and expansion abilities, the asynchronous interface is created for handshaking different clock domains between ADC and RF with MCU. To increase the use time of the WBSN system, a power management technique is developed for reducing power consumption. In addition, the multi-sensor controller is designed for detecting various biomedical signals. To prevent loss error from wireless transmission, use of an error correct coding technique is important in biomedical applications. The data encoder is added for lossless compression of various biomedical signals with a compression ratio of almost three. This design is successfully tested on a FPGA board. The VLSI architecture of this work contains 2.68-K gate counts and consumes power 496-μW at 133-MHz processing rate by using TSMC 0.13-μm CMOS process. Compared with the previous techniques, this work offers higher performance, more functions, and lower hardware cost than other micro controller designs.


  • Open Access

    A Power-Efficient Bio-Potential Acquisition Device with DS-MDE Sensors for Long-Term Healthcare Monitoring Applications

    by Chia-Lin Chang, Chih-Wei Chang, Hong-Yi Huang, Chen-Ming Hsu, Chia-Hsuan Huang, Jin-Chern Chiou, Ching-Hsing Luo

    This work describes a power-efficient bio-potential acquisition device for long-term healthcare applications that is implemented using novel microelectromechanical dry electrodes (MDE) and a low power bio-potential processing chip. Using micromachining technology, an attempt is also made to enhance the sensing reliability and stability by fabricating a diamond-shaped MDE (DS-MDE) that has a satisfactory self-stability capability and superior electric conductivity when attached onto skin without any extra skin tissue injury technology. To acquire differential bio-potentials such as ECG signals, the proposed processing chip fabricated in a standard CMOS process has a high common mode rejection ratio (C.M.R.R.) differential amplifier and a 12-bit analog-to-digital converter (ADC). Use of the proposed system and integrate simple peripheral commercial devices can obtain the ECG signal efficiently without additional skin tissue injury and ensure continuous monitoring more than 70 hours with a 400 mAh battery.