LGLuis Gil

Luis Gil

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luis Gil has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Juan Soto

    Centro de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Unidad Mixta Universidad Politécnica de Valencia–Universidad de Valencia de Valéncia, Camino de Vera s/n, E-46022 Valencia, Spain

    7 shared publications
  • Ramón Martínez-Máñez

    Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Spain

    7 shared publications
  • Eduardo Garcia-Breijo

    Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, 46022 Valencia, Spain

    5 shared publications
  • Eduard Llobet

    Universitat Rovira i Virgili

    3 shared publications
  • Jose Manuel Barat

    Instituto Universitario de Ingeniería de Alimentos-Food UPV, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain

    3 shared publications
  • Inmaculada Campos

    Centro de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Unidad Mixta Universidad Politécnica de Valencia–Universidad de Valencia de Valéncia, Camino de Vera s/n, E-46022 Valencia, Spain

    2 shared publications

Latest Publications

  • Open Access

    An Electronic Tongue Designed to Detect Ammonium Nitrate in Aqueous Solutions

    by Inmaculada Campos, Lluis Pascual, Juan Soto, Luis Gil-Sánchez, Ramón Martínez-Máez

    An electronic tongue has been developed to monitor the presence of ammonium nitrate in water. It is based on pulse voltammetry and consists of an array of eight working electrodes (Au; Pt; Rh; Ir; Cu; Co; Ag and Ni) encapsulated in a stainless steel cylinder. In a first step the electrochemical response of the different electrodes was studied in the presence of ammonium nitrate in water in order to further design the wave form used in the voltammetric tongue. The response of the electronic tongue was then tested in the presence of a set of 15 common inorganic salts; i.e.; NH4NO3; MgSO4; NH4Cl; NaCl; Na2CO3; (NH4)2SO4; MgCl2; Na3PO4; K2SO4; K2CO3; CaCl2; NaH2PO4; KCl; NaNO3; K2HPO4. A PCA plot showed a fairly good discrimination between ammonium nitrate and the remaining salts studied. In addition Fuzzy Art map analyses determined that the best classification was obtained using the Pt; Co; Cu and Ni electrodes. Moreover; PLS regression allowed the creation of a model to correlate the voltammetric response of the electrodes with concentrations of ammonium nitrate in the presence of potential interferents such as ammonium chloride and sodium nitrate.


  • Open Access

    An Embedded Simplified Fuzzy ARTMAP Implemented on a Microcontroller for Food Classification

    by Eduardo Garcia-Breijo, Jose Garrigues, Luis Gil Sanchez, Nicolas Laguarda-Miro

    In the present study, a portable system based on a microcontroller has been developed to classify different kinds of honeys. In order to do this classification, a Simplified Fuzzy ARTMAP network (SFA) implemented in a microcontroller has been used. Due to memory limits when working with microcontrollers, it is necessary to optimize the use of both program and data memory. Thus, a Graphical User Interface (GUI) for MATLAB® has been developed in order to optimize the necessary parameters to programme the SFA in a microcontroller. The measures have been carried out by potentiometric techniques using a multielectrode made of seven different metals. Next, the neural network has been trained on a PC by means of the GUI in Matlab using the data obtained in the experimental phase. The microcontroller has been programmed with the obtained parameters and then, new samples have been analysed using the portable system in order to test the model. Results are very promising, as an 87.5% recognition rate has been achieved in the training phase, which suggests that this kind of procedures can be successfully used not only for honey classification, but also for many other kinds of food.


  • Open Access

    Glyphosate Detection by Means of a Voltammetric Electronic Tongue and Discrimination of Potential Interferents

    by Román Bataller, Inmaculada Campos, Nicolas Laguarda-Miro, Miguel Alcañiz, Juan Soto, Ramón Martínez-Máñez, Luís Gil, Eduardo García-Breijo, Javier Ibáñez-Civera

    A new electronic tongue to monitor the presence of glyphosate (a non-selective systemic herbicide) has been developed. It is based on pulse voltammetry and consists in an array of three working electrodes (Pt, Co and Cu) encapsulated on a methacrylate cylinder. The electrochemical response of the sensing array was characteristic of the presence of glyphosate in buffered water (phosphate buffer 0.1 mol·dm−3, pH 6.7). Rotating disc electrode (RDE) studies were carried out with Pt, Co and Cu electrodes in water at room temperature and at pH 6.7 using 0.1 mol·dm−3 of phosphate as a buffer. In the presence of glyphosate, the corrosion current of the Cu and Co electrodes increased significantly, probably due to the formation of Cu2+ or Co2+ complexes. The pulse array waveform for the voltammetric tongue was designed by taking into account some of the redox processes observed in the electrochemical studies. The PCA statistical analysis required four dimensions to explain 95% of variance. Moreover, a two-dimensional representation of the two principal components differentiated the water mixtures containing glyphosate. Furthermore, the PLS statistical analyses allowed the creation of a model to correlate the electrochemical response of the electrodes with glyphosate concentrations, even in the presence of potential interferents such as humic acids and Ca2+. The system offers a PLS prediction model for glyphosate detection with values of 098, −2.3 × 10−5 and 0.94 for the slope, the intercept and the regression coefficient, respectively, which is in agreement with the good fit between the predicted and measured concentrations. The results suggest the feasibility of this system to help develop electronic tongues for glyphosate detection.


  • Fish freshness analysis using metallic potentiometric electrodes

    by Luis Gil, José M. Barat, Eduardo Garcia-Breijo, Javier Ibañez, Ramón Martínez-Máñez, Juan Soto, Eduard Llobet, Jesús Brezmes, M.-Concepción Aristoy, Fidel Toldrá


  • An electronic tongue for fish freshness analysis using a thick-film array of electrodes

    by Luis Gil, José M. Barat, Isabel Escriche, Eduardo Garcia-Breijo, Ramón Martínez-Máñez, Juan Soto


  • Analysis of Fish Freshness by Using Metallic Potentiometric Electrodes

    by Luis Gil, Eduardo Garcia-Breijo, Jose M. Barat, Ramon Martinez-Manez, Juan Soto, Francisco Baena, Javier Ibanez, Eduard Llobet, Jesus Brezmes

    We report herein the development of a simple electronic system that uses simple potentiometric electrodes applied to the analysis fish freshness. The array of sensors is built by using metallic electrodes as plain sharp wires or in a thick-film configuration. Experiments on real fish led to the conclusion that gold and silver electrodes are suitable for the development of qualitative systems able to classify fish in relation to its freshness. Equipment based on a microprocessors programmed with fuzzy logic can be developed for in situ monitorization of fish quality.


  • Open Access

    Electronic Tongue for Qualitative Analysis of Aqueous Solutions of Salts Using Thick-film Technology and Metal Electrodes

    by Luis Gil, Eduardo Garcia-Breijo, Javier Ibañez, Roberto H. Labrador, Eduard Llobet, Ramón Martínez-Máñez, Juan Soto

    An electronic tongue for the qualitative analysis of aqueous solutions of salts hasbeen developed. The following set of electrodes was used: RuO2, Ag, and Cu in thick-filmtechnology and Au, Pb, Zn and Ni as small bars of the corresponding metal. The response ofthe designed “electronic tongue” was tested on a family of samples containing pure salt andcomplex mixtures. The electrodes were used as potentiometric un-specific sensors and thee.m.f. of each electrode in contact with a certain aqueous solution was used as input signalfor a PCA analysis. The study showed that the set of electrodes were capable to discriminatebetween aqueous solutions of salts basically by their different content in anions and cations(the anions SO42-, Cl-, PO4H2-, CO3H-, NO3- and cations Na+ and K+ were studied). In orderto better analyze the basis for the discrimination power shown by the electronic tongue, aquantitative analysis was also envisaged. A fair estimation of the concentrations of thedifferent ions in the solutions studied appeared to be possible using this electronic tonguedesign.Keywords:


  • Coordinative and electrostatic forces in action: from the design of differential chromogenic anion sensors to selective carboxylate recognition

    by Beatriz García-Acosta, Xavier Albiach-Martí, Eduardo García, Luis Gil, Ramón Martínez-Máñez, Knut Rurack, Félix Sancenón, Juan Soto

    A new family of differential chromogenic anion chemosensors is described based on anilinopyridine–metal cation coordinative signalling ensembles.