AHAlireza Hariri

Alireza Hariri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alireza Hariri has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Jean W. Zu

    University of Toronto, Toronto, ON, Canada

    3 shared publications
  • Ming Jia

    Department of Mechanical & Industrial Engineering, University of Toronto/5 King’s College Road, Toronto, ON M5S 3G8, Canada

    2 shared publications
  • J. W. Zu

    Department of Mechanical and Industrial Engineering, University of Toronto, King's College Road, Toronto, ON, M5S 3G8 Canada

    1 shared publication
  • R. Ben Mrad

    Department of Mechanical and Industrial Engineering, University of Toronto, King's College Road, Toronto, ON, M5S 3G8 Canada

    1 shared publication

Latest Publications

  • Open Access

    A New Tissue Resonator Indenter Device and Reliability Study

    by Ming Jia, Jean W. Zu, Alireza Hariri

    Knowledge of tissue mechanical properties is widely required by medical applications, such as disease diagnostics, surgery operation, simulation, planning, and training. A new portable device, called Tissue Resonator Indenter Device (TRID), has been developed for measurement of regional viscoelastic properties of soft tissues at the Bio-instrument and Biomechanics Lab of the University of Toronto. As a device for soft tissue properties in-vivo measurements, the reliability of TRID is crucial. This paper presents TRID’s working principle and the experimental study of TRID’s reliability with respect to inter-reliability, intra-reliability, and the indenter misalignment effect as well.


  • Reliability Investigation of Tissue Resonator Indenter Device

    by Ming Jia, Jean W. Zu, Alireza Hariri

    Knowledge of tissue mechanical properties is widely required by medical applications, such as disease diagnostics, surgery operation, simulation, planning, and training. A new portable device, called Tissue Resonator Indenter Device (TRID), has been developed for measurement of regional viscoelastic properties of soft tissues at the Bio-instrument and Biomechanics Lab of the University of Toronto. As a device for soft tissue properties in-vivo measurements, the reliability of TRID is crucial. This paper presents TRID’s working principle and the experimental study of TRID’s reliability with respect to inter-reliability, intra-reliability, and the indenter misalignment effect as well. The experimental results show that TRID is a reliable device for in-vivo measurements of soft tissue mechanical properties.

  • Design of a Tissue Resonator Indenter Device for Measurement of Soft Tissue Viscoelastic Properties Using Parametric Identification

    by Alireza Hariri, Jean W. Zu

    The design of a new device called Tissue Resonator Indenter Device (TRID) for measuring soft tissue viscoelastic properties is presented. The two degrees-of-freedom device works based on mechanical vibration principles. When TRID comes into contact with a soft tissue, it can identify the tissue’s viscoelastic properties through the change of the device’s natural frequencies and damping ratios. In this paper, the deign of TRID is presented assuming Kelvin model for tissues. By working in the linear viscoelastic domain, TRID is designed to identify tissue properties in the range of 0–100 Hz. Assuming Kelvin model for tissues, the current paper develops a method for determining unknown tissue parameters using input-output data from TRID. Moreover, it is proved that the TRID’s parameters as well as the Kelvin tissue model parameters are globally identifiable. A parametric identification method using the prediction error approach is proposed for identifying the unknown tissue parameters in a grey-box state-space model. The reliability and effectiveness of the method for measuring soft tissue’s viscoelastic properties is demonstrated through simulation in the presence of considerable input and output noises.

  • Modeling of Elastic/Plastic Contact Between Nominally Flat Rough Surfaces Using an n-Point Asperity Model

    by A. Hariri, J. W. Zu, R. Ben Mrad

    The asperities of rough surfaces have long been considered to be points higher than their immediate neighbors. Based on this concept, theories were developed for quantitatively understanding the elastic and plastic nature of contact between rough surfaces. Recently it has been recognized that the above model for asperities is inadequate. Consequently, all the models that have been constructed based on that model are inadequate too. In this paper, based on a newly developed multiple-point asperity model, the elastic and plastic contact problem between nominally flat surfaces is reformulated. This leads to finding the deformed area, and load produced by the contact. The model is developed for the general form of isotropic rough surfaces with arbitrary height distribution and autocorrelation function (ACF). The microcontact areas generated by each asperity contact are considered to be circles. The Gaussian distribution of heights and exponential ACF are considered as a benchmark to compare the results of the new model with the existing models. Using results from numerical models developed by other groups, the new model is validated.