Giuseppe Forte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Giuseppe Forte has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Camps
CommSensLab-UPC, Departament Teoria del Senyal i Comunicacions, Universitat Politècnica de Catalunya, 08034 Barcelona, Spain
3 shared publications - Enric Valencia
Dept. Teor. del Senyal i Comunicacions, Univ. Politec. de Catalunya, Barcelona, Spain
2 shared publications - Hyuk Park
CommSensLab—UPC, Department of Signal Theory and Communications, Universitat Politècnica de Catalunya—BarcelonaTech, 08034 Barcelona, Spain
2 shared publications - Isaac Ramos-Perez
Remote Sensing Lab., Department Signal Theory and Communications, Universitat Politecnica de Catalunya (UPC) Campus Nord, Bldg D3, E-08034 Barcelona, Spain
2 shared publications - Mercè Vall-Llossera
Universitat Politecnica de Catalunya
2 shared publications - Nereida Rodriguez-Alvarez
Radio Science and Solar System Radar Group, Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
2 shared publications
Latest Publications
- Open Access
MERITXELL: The Multifrequency Experimental Radiometer with Interference Tracking for Experiments over Land and Littoral—Instrument Description, Calibration and Performance
MERITXELL is a ground-based multisensor instrument that includes a multiband dual-polarization radiometer, a GNSS reflectometer, and several optical sensors. Its main goals are twofold: to test data fusion techniques, and to develop Radio-Frequency Interference (RFI) detection, localization and mitigation techniques. The former is necessary to retrieve complementary data useful to develop geophysical models with improved accuracy, whereas the latter aims at solving one of the most important problems of microwave radiometry. This paper describes the hardware design, the instrument control architecture, the calibration of the radiometer, and several captures of RFI signals taken with MERITXELL in urban environment. The multiband radiometer has a dual linear polarization total-power radiometer topology, and it covers the L-, S-, C-, X-, K-, Ka-, and W-band. Its back-end stage is based on a spectrum analyzer structure which allows to perform real-time signal processing, while the rest of the sensors are controlled by a host computer where the off-line processing takes place. The calibration of the radiometer is performed using the hot-cold load procedure, together with the tipping curves technique in the case of the five upper frequency bands. Finally, some captures of RFI signals are shown for most of the radiometric bands under analysis, which evidence the problem of RFI in microwave radiometry, and the limitations they impose in external calibration.
Open AccessMERITXELL: The Multifrequency Experimental Radiometer with Interference Tracking for Experiments over Land and Littoral—Instrument Description, Calibration and Performance
MERITXELL is a ground-based multisensor instrument that includes a multiband dual-polarization radiometer, a GNSS reflectometer, and several optical sensors. Its main goals are twofold: to test data fusion techniques, and to develop Radio-Frequency Interference (RFI) detection, localization and mitigation techniques. The former is necessary to retrieve complementary data useful to develop geophysical models with improved accuracy, whereas the latter aims at solving one of the most important problems of microwave radiometry. This paper describes the hardware design, the instrument control architecture, the calibration of the radiometer, and several captures of RFI signals taken with MERITXELL in urban environment. The multiband radiometer has a dual linear polarization total-power radiometer topology, and it covers the L-, S-, C-, X-, K-, Ka-, and W-band. Its back-end stage is based on a spectrum analyzer structure which allows to perform real-time signal processing, while the rest of the sensors are controlled by a host computer where the off-line processing takes place. The calibration of the radiometer is performed using the hot-cold load procedure, together with the tipping curves technique in the case of the five upper frequency bands. Finally, some captures of RFI signals are shown for most of the radiometric bands under analysis, which evidence the problem of RFI in microwave radiometry, and the limitations they impose in external calibration.
- Open Access
PAU-SA: A Synthetic Aperture Interferometric Radiometer Test Bed for Potential Improvements in Future Missions
The Soil Moisture and Ocean Salinity (SMOS) mission is an Earth Explorer Opportunity mission from the European Space Agency (ESA). Its goal is to produce global maps of soil moisture and ocean salinity using the Microwave Imaging Radiometer by Aperture Synthesis (MIRAS). The purpose of the Passive Advanced Unit Synthetic Aperture (PAU-SA) instrument is to study and test some potential improvements that could eventually be implemented in future missions using interferometric radiometers such as the Geoestacionary Atmosferic Sounder (GAS), the Precipitation and All-weather Temperature and Humidity (PATH) and the Geostationary Interferometric Microwave Sounder (GIMS). Both MIRAS and PAU-SA are Y-shaped arrays with uniformly distributed antennas, but the receiver topology and the processing unit are quite different. The purpose of this work is to identify the elements in the MIRAS’s design susceptible of improvement and apply them in the PAU-SA instrument demonstrator, to test them in view of these future interferometric radiometer missions.
Open AccessPAU-SA: A Synthetic Aperture Interferometric Radiometer Test Bed for Potential Improvements in Future Missions
The Soil Moisture and Ocean Salinity (SMOS) mission is an Earth Explorer Opportunity mission from the European Space Agency (ESA). Its goal is to produce global maps of soil moisture and ocean salinity using the Microwave Imaging Radiometer by Aperture Synthesis (MIRAS). The purpose of the Passive Advanced Unit Synthetic Aperture (PAU-SA) instrument is to study and test some potential improvements that could eventually be implemented in future missions using interferometric radiometers such as the Geoestacionary Atmosferic Sounder (GAS), the Precipitation and All-weather Temperature and Humidity (PATH) and the Geostationary Interferometric Microwave Sounder (GIMS). Both MIRAS and PAU-SA are Y-shaped arrays with uniformly distributed antennas, but the receiver topology and the processing unit are quite different. The purpose of this work is to identify the elements in the MIRAS’s design susceptible of improvement and apply them in the PAU-SA instrument demonstrator, to test them in view of these future interferometric radiometer missions.
- 10 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Geoscience and Remote Sensing Letters
- Vol. 9 (4) , 774-777
Optimum Intercalibration Time in Synthetic Aperture Interferometric Radiometers: Application to SMOS
Interpolation strategies for calibration of the Soil Moisture and Ocean Salinity (SMOS) mission of the European Space Agency are tested and compared. Calibration strategy (how and how often) is critical in achieving the required performance of any instrument, but it is even more important in very complex instruments such as the new family of synthetic aperture interferometric radiometers and, in particular, in the Microwave Imaging Radiometer by Aperture Synthesis instrument aboard the SMOS mission. On one hand, frequent calibration reduces the available observation time. On the other hand, the calibration requirements for soil moisture applications are more relaxed than those for ocean salinity, so the intercalibration time requirements are very different. Since SMOS drifts are stationary, half-orbit information is available to perform different interpolation strategies. In this letter, these approaches are tested to estimate the calibration parameters between consecutive calibrations. The average root-mean-square phase error is then used to find the optimum interpolation strategy and intercalibration time. On the other side, in real-time instruments, the “future” calibration data are not available at the time of taking the measurements, and predictors are required to estimate the evolution of the calibration parameters from past data only. For these systems, the extended Kalman filter can be used. The intercalibration time in a real-time instrument is evaluated, and the requirements and performances are compared to offline instruments.
- 10 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Geoscience and Remote Sensing Letters
- Vol. 9 (4) , 774-777
Optimum Intercalibration Time in Synthetic Aperture Interferometric Radiometers: Application to SMOS
Interpolation strategies for calibration of the Soil Moisture and Ocean Salinity (SMOS) mission of the European Space Agency are tested and compared. Calibration strategy (how and how often) is critical in achieving the required performance of any instrument, but it is even more important in very complex instruments such as the new family of synthetic aperture interferometric radiometers and, in particular, in the Microwave Imaging Radiometer by Aperture Synthesis instrument aboard the SMOS mission. On one hand, frequent calibration reduces the available observation time. On the other hand, the calibration requirements for soil moisture applications are more relaxed than those for ocean salinity, so the intercalibration time requirements are very different. Since SMOS drifts are stationary, half-orbit information is available to perform different interpolation strategies. In this letter, these approaches are tested to estimate the calibration parameters between consecutive calibrations. The average root-mean-square phase error is then used to find the optimum interpolation strategy and intercalibration time. On the other side, in real-time instruments, the “future” calibration data are not available at the time of taking the measurements, and predictors are required to estimate the evolution of the calibration parameters from past data only. For these systems, the extended Kalman filter can be used. The intercalibration time in a real-time instrument is evaluated, and the requirements and performances are compared to offline instruments.