Jian-Wu Sheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jian-Wu Sheng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Han-Chang Shi
State Key Joint Laboratory of Environmental Simulate & Pollution Control, School of Environment, Tsinghua University, Beijing 10084, China
4 shared publications - Miao He
State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing 100084, China
3 shared publications - Feng Long
School of Environment and Natural Resources, Renmin University of China, Beijing 100872, China
2 shared publications - Anna Zhu
Research Institute of Chemical Defense, Academy of Military Sciences PLA China, Beijing 102205, China; State Key Laboratory of NBC Protection FOR Civilian, Beijing 102205, China
1 shared publication Hong-Chen Wang
1 shared publicationShao-Qing Yu
1 shared publication
Latest Publications
- 1 April 2014
- Vol. 35 (4) , 1561-5
[Immunosensor for rapid detection of 1,3-dinitrobenzene].
An immunosensor for the rapid detection of 1,3-dinitrobenzene was developed based on an evanescent wave all-fiber biosensing platform with the detection limits of 0.054 mg x L(-1), and the detection cycle was less than 10 min. Hapten-carrier conjugates NB-OVA were synthesized by mixing 4-nitrohippuric acid and OVA activated by EDC, and then the conjugates were immobilized onto the silane layer on the probe with a heterobifunctional crosslinker. The probe modified had good robustness and regeneration performance, which allowed the performance of more than 100 assay cycles without significant loss of reactivity. Several water samples of different origins were measured with less than 4.5% -10.0% deviation of the detection and the recovery rate of 1,3-dinitrobenzene was between 80% and 120%, which proved the system's precision and accuracy and negligible matrix effects. This immunosensor shows great potential in rapid detection of 1,3-dinitrobenzene in practical waters.
- 1 April 2014
- Vol. 35 (4) , 1561-5
[Immunosensor for rapid detection of 1,3-dinitrobenzene].
An immunosensor for the rapid detection of 1,3-dinitrobenzene was developed based on an evanescent wave all-fiber biosensing platform with the detection limits of 0.054 mg x L(-1), and the detection cycle was less than 10 min. Hapten-carrier conjugates NB-OVA were synthesized by mixing 4-nitrohippuric acid and OVA activated by EDC, and then the conjugates were immobilized onto the silane layer on the probe with a heterobifunctional crosslinker. The probe modified had good robustness and regeneration performance, which allowed the performance of more than 100 assay cycles without significant loss of reactivity. Several water samples of different origins were measured with less than 4.5% -10.0% deviation of the detection and the recovery rate of 1,3-dinitrobenzene was between 80% and 120%, which proved the system's precision and accuracy and negligible matrix effects. This immunosensor shows great potential in rapid detection of 1,3-dinitrobenzene in practical waters.
- 1 June 2012
- Vol. 33 (6) , 2095-103
[Matrix effect and control of immunoassay for environmental samples].
Immunoassay provides very specific, highly sensitive, rapid, and cost-effective analyses for a variety of environmental contaminants. Since the immunoassay detects the environmental samples without pre-treatment, the interferences caused by various matrixes of environmental samples are a major problem, which can greatly affect the detection results. In this paper, based on the enzyme-linked immunosorbent assay (ELISA) for detection of Microcystin-LR (MC-LR), the effect of many kinds of matrixes on ELISA was systematically analyzed, and the corresponding method to control or eliminate the disbennifit effect was proposed. Finally, an integrated and packaged strategy-using the following buffer system as a diluent, i.e. 0.1 mol x L(-1) pH 7.4 PBS (10 x PBS) containing 1% BSA, 0.5% EDTA and 40 g x L(-1) sodium chloride-was given to control the overall matrix effects of environmental samples on ELISA detection. This strategy is also applicable to other kinds of immunoassays for environmental samples.
- 1 June 2012
- Vol. 33 (6) , 2095-103
[Matrix effect and control of immunoassay for environmental samples].
Immunoassay provides very specific, highly sensitive, rapid, and cost-effective analyses for a variety of environmental contaminants. Since the immunoassay detects the environmental samples without pre-treatment, the interferences caused by various matrixes of environmental samples are a major problem, which can greatly affect the detection results. In this paper, based on the enzyme-linked immunosorbent assay (ELISA) for detection of Microcystin-LR (MC-LR), the effect of many kinds of matrixes on ELISA was systematically analyzed, and the corresponding method to control or eliminate the disbennifit effect was proposed. Finally, an integrated and packaged strategy-using the following buffer system as a diluent, i.e. 0.1 mol x L(-1) pH 7.4 PBS (10 x PBS) containing 1% BSA, 0.5% EDTA and 40 g x L(-1) sodium chloride-was given to control the overall matrix effects of environmental samples on ELISA detection. This strategy is also applicable to other kinds of immunoassays for environmental samples.
- Open Access
Matrix Effects on the Microcystin-LR Fluorescent Immunoassay Based on Optical Biosensor
Matrix effects on the microcystin-LR fluorescent immunoassay based on the evanescent wave all-fiber immunosensor (EWAI) and their elimination methods were studied. The results indicated that PBS and humic acid did not affect the monitoring of samples under the investigated conditions. When the pH was less than 6 or higher than 8, the fluorescence signals detected by immunosensor systems were obviously reduced with the decrease or increase of pH. When the pH ranged from 6 to 8, IC50 and the linear working range of MC-LR calculated from the detection curves were 1.01~1.04 μg/L and 0.12~10.5 μg/L, respectively, which was favourable for an MC-LR immunoassay. Low concentrations of Cu2+ rarely affected the detection performance of MC-LR. When the concentration of CuSO4 was higher than 5 mg/L, the fluorescence signal detected by EWAI clearly decreased, and when the concentration of CuSO4 was 10 mg/L, the fluorescence signal detected was reduced by 70%. The influence of Cu2+ on the immunoassay could effectively be compromised when chelating reagent EDTA was added to the pre-reaction mixture.
Open AccessMatrix Effects on the Microcystin-LR Fluorescent Immunoassay Based on Optical Biosensor
Matrix effects on the microcystin-LR fluorescent immunoassay based on the evanescent wave all-fiber immunosensor (EWAI) and their elimination methods were studied. The results indicated that PBS and humic acid did not affect the monitoring of samples under the investigated conditions. When the pH was less than 6 or higher than 8, the fluorescence signals detected by immunosensor systems were obviously reduced with the decrease or increase of pH. When the pH ranged from 6 to 8, IC50 and the linear working range of MC-LR calculated from the detection curves were 1.01~1.04 μg/L and 0.12~10.5 μg/L, respectively, which was favourable for an MC-LR immunoassay. Low concentrations of Cu2+ rarely affected the detection performance of MC-LR. When the concentration of CuSO4 was higher than 5 mg/L, the fluorescence signal detected by EWAI clearly decreased, and when the concentration of CuSO4 was 10 mg/L, the fluorescence signal detected was reduced by 70%. The influence of Cu2+ on the immunoassay could effectively be compromised when chelating reagent EDTA was added to the pre-reaction mixture.
- 1 June 2006
- Vol. 27 (6) , 1166-70
[Detection of microcystin-LR in waters using indirect competitive ELISA].
Indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was established to detect microcystin-LR in waters, with the concentration of the complete antigen was 5microg/mL, the dilution of the monoclonal antibody was 1:3,000, the dilution of the enzyme tracer (goat anti-rabbit IgG-peroxidase) was 1:3,000, the concentration range of microcystin-LR was between 0.001 approximately 30microg/L, and using o-phenylenediamine as substrate. The assay showed a high relativity of more than 99% with high performance liquid chromatography, a mean relative standard deviation less than 10% , a detection limitation under 0.01microg/L and quantitative detection range was 0.01 approximately 3microg/L, high specificity for [4-arginine] microcystin, and it could still perform well under the influence from the samples.
- 1 June 2006
- Vol. 27 (6) , 1166-70
[Detection of microcystin-LR in waters using indirect competitive ELISA].
Indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) was established to detect microcystin-LR in waters, with the concentration of the complete antigen was 5microg/mL, the dilution of the monoclonal antibody was 1:3,000, the dilution of the enzyme tracer (goat anti-rabbit IgG-peroxidase) was 1:3,000, the concentration range of microcystin-LR was between 0.001 approximately 30microg/L, and using o-phenylenediamine as substrate. The assay showed a high relativity of more than 99% with high performance liquid chromatography, a mean relative standard deviation less than 10% , a detection limitation under 0.01microg/L and quantitative detection range was 0.01 approximately 3microg/L, high specificity for [4-arginine] microcystin, and it could still perform well under the influence from the samples.