Stefanie Demming
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stefanie Demming has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Stephanus Büttgenbach
Institute for Microtechnology, Technische Universität Braunschweig, Alte Salzdahlumer Str. 203, 38124 Braunschweig, Germany
3 shared publications- Andreu Llobera
Institut de Microelectrònica de Barcelona (IMB-CNM, CSIC), SPAIN
2 shared publications Astrid Edlich
Institut für Bioverfahrenstechnik, Technische Universität Braunschweig, Braunschweig, Germany
2 shared publications- Jordi Vila-Planas
Instituto de Microelectrónica de Barcelona (IMB-CNM), CSIC, Campus UAB, 08193 Bellaterra, Spain
2 shared publications - Andrey Ipatov
International Iberian Nanotechnology Laboratory (INL), Avenida Mestre José Veiga, 4715-310, Braga, Portugal
1 shared publication - Anne Hahn
Nanotechnology Department, Laser Zentrum Hannover e.V. (LZH), Hollerithallee 8, 30419 Hannover, Germany
1 shared publication
Latest Publications
- 20 May 2011
- Published by Wiley in Physica Status Solidi (a)
- Vol. 208 (6) , 1301-1307
Characterization of long‐term stability of hydrophilized PEG‐grafted PDMS within different media for biotechnological and pharmaceutical applications
Poly(dimethylsiloxane) (PDMS) is broadly utilized for the development of disposable lab‐on‐a‐chip systems. For many microfluidic applications hydrophilic surface characteristics are indispensable. In this work, an easy, reliable and stable surface hydrophilization procedure based on poly(ethylene glycol) (PEG)‐silanization is presented that overcomes the hydrophobic nature of PDMS. Furthermore, the long‐term stability of the grafting as well as the effect of different parameters (e.g., applied solvent) on the hydrophilicity according to the measured contact angles (CAs) are analyzed within different media. Finally, the successful hydrophilization of different PDMS microfluidic devices and the effect of its performance are demonstrated (e.g., in a micro‐emulsification component). magnified image Effect of the surface properties of PDMS‐structured devices on the performance of drop emulsification with regard to the CA: (a) bare, hydrophobic and (b) PEG‐grafted, hydrophilic PDMS.
- 20 May 2011
- Published by Wiley in Physica Status Solidi (a)
- Vol. 208 (6) , 1301-1307
Characterization of long‐term stability of hydrophilized PEG‐grafted PDMS within different media for biotechnological and pharmaceutical applications
Poly(dimethylsiloxane) (PDMS) is broadly utilized for the development of disposable lab‐on‐a‐chip systems. For many microfluidic applications hydrophilic surface characteristics are indispensable. In this work, an easy, reliable and stable surface hydrophilization procedure based on poly(ethylene glycol) (PEG)‐silanization is presented that overcomes the hydrophobic nature of PDMS. Furthermore, the long‐term stability of the grafting as well as the effect of different parameters (e.g., applied solvent) on the hydrophilicity according to the measured contact angles (CAs) are analyzed within different media. Finally, the successful hydrophilization of different PDMS microfluidic devices and the effect of its performance are demonstrated (e.g., in a micro‐emulsification component). magnified image Effect of the surface properties of PDMS‐structured devices on the performance of drop emulsification with regard to the CA: (a) bare, hydrophobic and (b) PEG‐grafted, hydrophilic PDMS.
- Open Access
Application of an E-Tongue to the Analysis of Monovarietal and Blends of White Wines
This work presents a multiparametric system capable of characterizing and classifying white wines according to the grape variety and geographical origin. Besides, it quantifies specific parameters of interest for quality control in wine. The system, known as a hybrid electronic tongue, consists of an array of electrochemical microsensors—six ISFET based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, a gold microelectrode and a microelectrode for sensing electrochemical oxygen demand—and a miniaturized optofluidic system. The test sample set comprised eighteen Catalan monovarietal white wines from four different grape varieties, two Croatian monovarietal white wines and seven bi- and trivarietal mixtures prepared from the Catalan varieties. Different chemometric tools were used to characterize (i.e., Principal Component Analysis), classify (i.e., Soft Independent Modeling Class Analogy) and quantify (i.e., Partial-Least Squares) some parameters of interest. The results demonstrate the usefulness of the multisensor system for analysis of wine.
Open AccessApplication of an E-Tongue to the Analysis of Monovarietal and Blends of White Wines
This work presents a multiparametric system capable of characterizing and classifying white wines according to the grape variety and geographical origin. Besides, it quantifies specific parameters of interest for quality control in wine. The system, known as a hybrid electronic tongue, consists of an array of electrochemical microsensors—six ISFET based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, a gold microelectrode and a microelectrode for sensing electrochemical oxygen demand—and a miniaturized optofluidic system. The test sample set comprised eighteen Catalan monovarietal white wines from four different grape varieties, two Croatian monovarietal white wines and seven bi- and trivarietal mixtures prepared from the Catalan varieties. Different chemometric tools were used to characterize (i.e., Principal Component Analysis), classify (i.e., Soft Independent Modeling Class Analogy) and quantify (i.e., Partial-Least Squares) some parameters of interest. The results demonstrate the usefulness of the multisensor system for analysis of wine.
- 30 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (3-4) , 431-439
Poly(dimethylsiloxane) photonic microbioreactors based on segmented waveguides for local absorbance measurement
We present the development of microbioreactors (MBRs) based on poly(dimethylsiloxane) (PDMS) segmented waveguides (SWG) for local absorbance measurements. Two different MBRs were studied, either using symmetric or asymmetric SWG (being defined as MBR-S and MBR-A, respectively). Their optical and fluidic performances were numerically analyzed, showing robustness from an optical point of view and distinct fluid flow profile. The optical characterization was done in two steps. Initially, the experimental limit of detection (LOD) and the sensitivity were determined for two different analytes (fluorescein and methylorange). With both systems, a similar limit of detection for both analytes was obtained, being in the micromolar level. Their sensitivities were 20.2±0.3 (×10−3) A.U./μM and 5.5±0.2 (×10−3) A.U./μM for fluorescein and methylorange, respectively. Once validated its applicability for local absorbance measurements, a continuous cultivation of Saccharomyces cerevisiae was done to test the viability of the proposed systems for photonic MBRs. Concretely, the cell growth was locally monitored inside the MBR during 33 h. Spectral analysis showed that the determination of the culture parameters were wavelength dependant, with a growth rate of 0.39±0.02 h−1 and a doubling time of 1.65±0.09 h at an optimal wavelength of 469.9±0.3 nm. Besides the easy and monolithic integration of the SWG into poly(dimethylsiloxane) microfluidic systems, the results presented here are very promising for the application in any disposable photonic lab-on-a-chip systems used for online analysis or photonic MBRs.
- 30 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (3-4) , 431-439
Poly(dimethylsiloxane) photonic microbioreactors based on segmented waveguides for local absorbance measurement
We present the development of microbioreactors (MBRs) based on poly(dimethylsiloxane) (PDMS) segmented waveguides (SWG) for local absorbance measurements. Two different MBRs were studied, either using symmetric or asymmetric SWG (being defined as MBR-S and MBR-A, respectively). Their optical and fluidic performances were numerically analyzed, showing robustness from an optical point of view and distinct fluid flow profile. The optical characterization was done in two steps. Initially, the experimental limit of detection (LOD) and the sensitivity were determined for two different analytes (fluorescein and methylorange). With both systems, a similar limit of detection for both analytes was obtained, being in the micromolar level. Their sensitivities were 20.2±0.3 (×10−3) A.U./μM and 5.5±0.2 (×10−3) A.U./μM for fluorescein and methylorange, respectively. Once validated its applicability for local absorbance measurements, a continuous cultivation of Saccharomyces cerevisiae was done to test the viability of the proposed systems for photonic MBRs. Concretely, the cell growth was locally monitored inside the MBR during 33 h. Spectral analysis showed that the determination of the culture parameters were wavelength dependant, with a growth rate of 0.39±0.02 h−1 and a doubling time of 1.65±0.09 h at an optimal wavelength of 469.9±0.3 nm. Besides the easy and monolithic integration of the SWG into poly(dimethylsiloxane) microfluidic systems, the results presented here are very promising for the application in any disposable photonic lab-on-a-chip systems used for online analysis or photonic MBRs.
- 18 March 2010
- Published by Wiley in Physica Status Solidi (a)
- Vol. 207 (4) , 898-903
Softlithographic partial integration of surface-active nanoparticles in a PDMS matrix for microfluidic biodevices
- 18 March 2010
- Published by Wiley in Physica Status Solidi (a)
- Vol. 207 (4) , 898-903
Softlithographic partial integration of surface-active nanoparticles in a PDMS matrix for microfluidic biodevices