Frank Rupp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Frank Rupp has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Bünger
DWI e.V. and Institute of Technical and Macromolecular Chemistry, RWTH Aachen University, Pauwelsstr. 8, D-52056 Aachen, Germany
1 shared publication - Frank K. Gehring
Biosensor Research Group, Institute of Clinical and Experimental Transfusion Medicine and Centre of Clinical Transfusion Medicine (ZKT), Tuebingen University and German Red Cross Blood Transfusion Service BW/H, Germany
1 shared publication - Gerhard Ziemer
Clinical Research Laboratory, Department of Congenital & Pediatric Cardiac Surgery, Children’s University Hospital, Tuebingen University, Calwerstr 7/1, 72076 Tuebingen, Germany
1 shared publication - Hans Peter Wendel
Department of Thoracic and Cardiovascular Surgery, University Hospital Tuebingen, Calwerstraße 7/1, 72076 Tuebingen, Germany
1 shared publication - Hinnak Northoff
Zentrum für Klinische Transfusionsmedizin (ZKT) and Institute of Clinical and Experimental Transfusion Medicine (IKET), University Hospital Tuebingen, Tuebingen, Germany
1 shared publication Ingrid Stephan
University Hospital Tübingen Section Medical Materials Science & Technology, Germany
1 shared publication
Latest Publications
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 237
QCM analysis of chlorhexidine interaction with salivary and S. gordonii films on titanium implant surfaces
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 237
QCM analysis of chlorhexidine interaction with salivary and S. gordonii films on titanium implant surfaces
- Open Access
NCO-sP(EO-stat-PO) Coatings on Gold Sensors—a QCM Study of Hemocompatibility
The reliability of implantable blood sensors is often hampered by unspecific adsorption of plasma proteins and blood cells. This not only leads to a loss of sensor signal over time, but can also result in undesired host vs. graft reactions. Within this study we evaluated the hemocompatibility of isocyanate conjugated star shaped polytheylene oxide—polypropylene oxide co-polymers NCO-sP(EO-stat-PO) when applied to gold surfaces as an auspicious coating material for gold sputtered blood contacting sensors. Quartz crystal microbalance (QCM) sensors were coated with ultrathin NCO-sP(EO-stat-PO) films and compared with uncoated gold sensors. Protein resistance was assessed by QCM measurements with fibrinogen solution and platelet poor plasma (PPP), followed by quantification of fibrinogen adsorption. Hemocompatibility was tested by incubation with human platelet rich plasma (PRP). Thrombin antithrombin-III complex (TAT), β-thromboglobulin (β-TG) and platelet factor 4 (PF4) were used as coagulation activation markers. Furthermore, scanning electron microscopy (SEM) was used to visualize platelet adhesion to the sensor surfaces. Compared to uncoated gold sensors, NCO-sP(EO-stat-PO) coated sensors revealed significant better resistance against protein adsorption, lower TAT generation and a lower amount of adherent platelets. Moreover, coating with ultrathin NCO-sP(EO-stat-PO) films creates a cell resistant hemocompatible surface on gold that increases the chance of prolonged sensor functionality and can easily be modified with specific receptor molecules.
Open AccessNCO-sP(EO-stat-PO) Coatings on Gold Sensors—a QCM Study of Hemocompatibility
The reliability of implantable blood sensors is often hampered by unspecific adsorption of plasma proteins and blood cells. This not only leads to a loss of sensor signal over time, but can also result in undesired host vs. graft reactions. Within this study we evaluated the hemocompatibility of isocyanate conjugated star shaped polytheylene oxide—polypropylene oxide co-polymers NCO-sP(EO-stat-PO) when applied to gold surfaces as an auspicious coating material for gold sputtered blood contacting sensors. Quartz crystal microbalance (QCM) sensors were coated with ultrathin NCO-sP(EO-stat-PO) films and compared with uncoated gold sensors. Protein resistance was assessed by QCM measurements with fibrinogen solution and platelet poor plasma (PPP), followed by quantification of fibrinogen adsorption. Hemocompatibility was tested by incubation with human platelet rich plasma (PRP). Thrombin antithrombin-III complex (TAT), β-thromboglobulin (β-TG) and platelet factor 4 (PF4) were used as coagulation activation markers. Furthermore, scanning electron microscopy (SEM) was used to visualize platelet adhesion to the sensor surfaces. Compared to uncoated gold sensors, NCO-sP(EO-stat-PO) coated sensors revealed significant better resistance against protein adsorption, lower TAT generation and a lower amount of adherent platelets. Moreover, coating with ultrathin NCO-sP(EO-stat-PO) films creates a cell resistant hemocompatible surface on gold that increases the chance of prolonged sensor functionality and can easily be modified with specific receptor molecules.