Concepción Sánchez-Pedreño
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Concepción Sánchez-Pedreño has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Joaquín A. Ortuño
Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, 30071 Murcia, Spain
5 shared publications- Joaquín Angel Ortuño
Department of Analytical Chemistry, University of Murcia, 30100 Murcia, Spain
4 shared publications - Isabel Albero
Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, 30071 Murcia, Spain
3 shared publications - María Soledad García
Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, 30071 Murcia, Spain
3 shared publications Isabel Albero
Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, 30071 Murcia, Spain
2 shared publicationsJorge Hernández
Department of Analytical Chemistry, University of Murcia, 30071 Murcia, Spain
2 shared publications
Latest Publications
- Open Access
A New Tiapride Selective Electrode and Its Clinical Application
The construction and electrochemical response characteristics of a poly(vinylchloride) (PVC) membrane selective electrode for the determination of tiapride (TPD) are described. The sensing membrane comprised an ion-pair formed between the protonated drug and tetraphenylborate (TPB-) in a plasticized PVC matrix. The influence of membrane composition on the electrode response was studied. The electrode showed a fast, stable and Nernstian response over a wide tiapride concentration range (1x10-5-1x10-2 M) with a slope of 57.5±0.2 mV dec-1 of concentration, a detection limit of 4.3x10-6±2.5x10-7 M, a wide working pH range (2-8) and a fast response time (< 5 s). The electrode showed good selectivity towards tiapride with respect to some inorganic and organic compounds. The electrode has been applied to the determination of tiapride in human urine and iontophoresis solution.
Open AccessA New Tiapride Selective Electrode and Its Clinical Application
The construction and electrochemical response characteristics of a poly(vinylchloride) (PVC) membrane selective electrode for the determination of tiapride (TPD) are described. The sensing membrane comprised an ion-pair formed between the protonated drug and tetraphenylborate (TPB-) in a plasticized PVC matrix. The influence of membrane composition on the electrode response was studied. The electrode showed a fast, stable and Nernstian response over a wide tiapride concentration range (1x10-5-1x10-2 M) with a slope of 57.5±0.2 mV dec-1 of concentration, a detection limit of 4.3x10-6±2.5x10-7 M, a wide working pH range (2-8) and a fast response time (< 5 s). The electrode showed good selectivity towards tiapride with respect to some inorganic and organic compounds. The electrode has been applied to the determination of tiapride in human urine and iontophoresis solution.
- Open Access
Flow-through Bulk Optode for Spectrophotometric Determination of Thiocyanate and Its Application to Water and Saliva Analysis
A flow-through spectrophotometric bulk optode for the flow-injectiondetermination of thiocyanate is described. As active constituents, the optode incorporatesthe lipophilized pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazo)phenol andmethyltridodecyl ammonium chloride, dissolved in a plasticized poly(vinyl)chloridemembrane entrapped in a cellulose support. The optode is applied, in conjunction with theflow injection technique, to the determination of thiocyanate at pH 7.5 (TRIS/H2SO4). Thesensor is readily regenerated with a 10-2 M NaOH carrier solution. The analyticalcharacteristics of this optode with respect to thiocyanate response time, dynamicmeasurement range, reproducibility and selectivity are discussed. The proposed FI methodis applied to the determination of thiocyanate in waters from different sources and in humansaliva samples in order to distinguish between smokers and non-smokers.
Open AccessFlow-through Bulk Optode for Spectrophotometric Determination of Thiocyanate and Its Application to Water and Saliva Analysis
A flow-through spectrophotometric bulk optode for the flow-injectiondetermination of thiocyanate is described. As active constituents, the optode incorporatesthe lipophilized pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazo)phenol andmethyltridodecyl ammonium chloride, dissolved in a plasticized poly(vinyl)chloridemembrane entrapped in a cellulose support. The optode is applied, in conjunction with theflow injection technique, to the determination of thiocyanate at pH 7.5 (TRIS/H2SO4). Thesensor is readily regenerated with a 10-2 M NaOH carrier solution. The analyticalcharacteristics of this optode with respect to thiocyanate response time, dynamicmeasurement range, reproducibility and selectivity are discussed. The proposed FI methodis applied to the determination of thiocyanate in waters from different sources and in humansaliva samples in order to distinguish between smokers and non-smokers.
- 9 October 2006
- Vol. 6 (10) , 1224-1233
Flow-through Bulk Optode for Spectrophotometric Determination of Thiocyanate and Its Application to Water and Saliva Analysis
A flow-through spectrophotometric bulk optode for the flow-injection determination of thiocyanate is described. As active constituents, the optode incorporates the lipophilized pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazo)phenol and methyltridodecyl ammonium chloride, dissolved in a plasticized poly(vinyl)chloride membrane entrapped in a cellulose support. The optode is applied, in conjunction with the flow injection technique, to the determination of thiocyanate at pH 7.5 (TRIS/H2SO4). The sensor is readily regenerated with a 10-2 M NaOH carrier solution. The analytical characteristics of this optode with respect to thiocyanate response time, dynamic measurement range, reproducibility and selectivity are discussed. The proposed FI method is applied to the determination of thiocyanate in waters from different sources and in human saliva samples in order to distinguish between smokers and non-smokers.
- 9 October 2006
- Vol. 6 (10) , 1224-1233
Flow-through Bulk Optode for Spectrophotometric Determination of Thiocyanate and Its Application to Water and Saliva Analysis
A flow-through spectrophotometric bulk optode for the flow-injection determination of thiocyanate is described. As active constituents, the optode incorporates the lipophilized pH indicator 5-octadecanoyloxy-2-(4-nitrophenylazo)phenol and methyltridodecyl ammonium chloride, dissolved in a plasticized poly(vinyl)chloride membrane entrapped in a cellulose support. The optode is applied, in conjunction with the flow injection technique, to the determination of thiocyanate at pH 7.5 (TRIS/H2SO4). The sensor is readily regenerated with a 10-2 M NaOH carrier solution. The analytical characteristics of this optode with respect to thiocyanate response time, dynamic measurement range, reproducibility and selectivity are discussed. The proposed FI method is applied to the determination of thiocyanate in waters from different sources and in human saliva samples in order to distinguish between smokers and non-smokers.
- 11 July 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 122 (2) , 369-374
Flow-injection pulse amperometric detection based on ion transfer across a water-plasticized polymeric membrane interface for the determination of imipramine
- 11 July 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 122 (2) , 369-374
Flow-injection pulse amperometric detection based on ion transfer across a water-plasticized polymeric membrane interface for the determination of imipramine
- 26 June 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 115 (2) , 584-588
Linear and nonlinear approaches to study transient signals of a flow-through bulk optode
- 26 June 2006
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 115 (2) , 584-588
Linear and nonlinear approaches to study transient signals of a flow-through bulk optode
- 21 May 2004
- Published by Wiley in Electroanalysis
- Vol. 16 (10) , 827-831
Flow‐Injection Amperometric Detection with Solvent Polymeric Membrane Ion Sensors
An amperometric detector for hydrophobic ions based on a plasticized poly(vinyl) chloride (PVC) membrane incorporated in a flow‐injection system was developed. A four‐electrode potentiostat with ohmic drop compensation was used, while a flow‐through cell incorporated the four electrodes and the membrane, which contained tetrabutylammonium tetraphenylborate. When the influence of the applied potential and of the flow‐injection variables on the determination of tetrabutylammonium was studied, a linear relationship was observed between current peak height and ion concentration over a range of 5×10−6–6×10−5 M tetrabutylammonium. Good repeatability and between‐day reproducibility and high sample frequency were obtained. The effect of other ions was studied. Two different amperometric methods, indirect and direct, were also developed for the determination of dodecylsulfate in the concentration range 3×10−5–9×10−4 M.
- 21 May 2004
- Published by Wiley in Electroanalysis
- Vol. 16 (10) , 827-831
Flow‐Injection Amperometric Detection with Solvent Polymeric Membrane Ion Sensors
An amperometric detector for hydrophobic ions based on a plasticized poly(vinyl) chloride (PVC) membrane incorporated in a flow‐injection system was developed. A four‐electrode potentiostat with ohmic drop compensation was used, while a flow‐through cell incorporated the four electrodes and the membrane, which contained tetrabutylammonium tetraphenylborate. When the influence of the applied potential and of the flow‐injection variables on the determination of tetrabutylammonium was studied, a linear relationship was observed between current peak height and ion concentration over a range of 5×10−6–6×10−5 M tetrabutylammonium. Good repeatability and between‐day reproducibility and high sample frequency were obtained. The effect of other ions was studied. Two different amperometric methods, indirect and direct, were also developed for the determination of dodecylsulfate in the concentration range 3×10−5–9×10−4 M.
- 8 October 2003
- Published by Wiley in Electroanalysis
- Vol. 15 (19) , 1536-1540
Nonmonotonic Transient Potential Signals with an 18‐Crown‐6 based Ion‐Selective Electrode in a Flow‐Injection System
The dynamic potential response of an 18‐crown‐6 based ion‐selective electrode towards Li+, Na+, K+ and Ca2+, in a flow‐injection system is studied. Different double nonmonotonic transient signals are obtained for the different ions. The influence of the flow‐injection variables and of ion concentration on the signals is studied. Two signal parameters, the relative return rates, are found to be characteristic for each ion and are constant for a concentration range of 1–3 decades. The nonmomotonic transient signals obtained are explained by reference to the theoretical models reported.
- 8 October 2003
- Published by Wiley in Electroanalysis
- Vol. 15 (19) , 1536-1540
Nonmonotonic Transient Potential Signals with an 18‐Crown‐6 based Ion‐Selective Electrode in a Flow‐Injection System
The dynamic potential response of an 18‐crown‐6 based ion‐selective electrode towards Li+, Na+, K+ and Ca2+, in a flow‐injection system is studied. Different double nonmonotonic transient signals are obtained for the different ions. The influence of the flow‐injection variables and of ion concentration on the signals is studied. Two signal parameters, the relative return rates, are found to be characteristic for each ion and are constant for a concentration range of 1–3 decades. The nonmomotonic transient signals obtained are explained by reference to the theoretical models reported.
- 1 September 2003
- Published by Springer Nature in Microchimica Acta
- Vol. 143 (1) , 59-63
Flow-Through Bulk Optode for the Spectrophotometric Determination of Perchlorate
- 1 September 2003
- Published by Springer Nature in Microchimica Acta
- Vol. 143 (1) , 59-63
Flow-Through Bulk Optode for the Spectrophotometric Determination of Perchlorate
- 28 May 2003
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 32 (4-5) , 1003-1010
Spectrophotometric determination of cimetidine in pharmaceuticals and urine using batch and flow-injection methods
- 28 May 2003
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 32 (4-5) , 1003-1010
Spectrophotometric determination of cimetidine in pharmaceuticals and urine using batch and flow-injection methods
- 1 July 2002
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 29 (5) , 779-786
Determination of zinc (II) in pharmaceuticals based on a flow-through bulk optode
- 1 July 2002
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 29 (5) , 779-786
Determination of zinc (II) in pharmaceuticals based on a flow-through bulk optode