NCNathaniel C. Cady

Nathaniel C. Cady

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nathaniel C. Cady has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Analysis of Bacterial Surface Interactions Using Microfluidic Systems

    by Aaron P. Mosier, Nathaniel C. Cady

    Modern microbiological research has increasingly focused on the interactions between bacterial cells and the surfaces that they inhabit. To this end, microfluidic devices have played a large role in enabling research of cell-surface interactions, especially surface attachment and biofilm formation. This review provides background on microfluidic devices and their use in biological systems, as well specific examples from current literature. Methods to observe and interrogate cells within microfluidic devices are described, as well as the analytical techniques that are used to collect these data.


  • Copper‐Based Nanostructured Coatings on Natural Cellulose: Nanocomposites Exhibiting Rapid and Efficient Inhibition of a Multi‐Drug Resistant Wound Pathogen, A. baumannii, and Mammalian Cell Biocompatibility In Vitro

    by Nathaniel C. Cady, Jason L. Behnke, Aaron D. Strickland

    This paper describes a layer‐by‐layer (LBL) electrostatic self‐assembly process for fabricating highly efficient antimicrobial nanocoatings on a natural cellulose substrate. The composite materials comprise a chemically modified cotton substrate and a layer of sub‐5 nm copper‐based nanoparticles. The LBL process involves a chemical preconditioning step to impart high negative surface charge on the cotton substrate for chelation controlled binding of cupric ions (Cu2+), followed by chemical reduction to yield nanostructured coatings on cotton fibers. These model wound dressings exhibit rapid and efficient killing of a multidrug resistant bacterial wound pathogen, A. baumannii, where an 8‐log reduction in bacterial growth can be achieved in as little as 10 min of contact. Comparative silver‐based nanocoated wound dressings–a more conventional antimicrobial composite material–exhibit much lower antimicrobial efficiencies; a 5‐log reduction in A. baumannii growth is possible after 24 h exposure times to silver nanoparticle‐coated cotton substrates. The copper nanoparticle–cotton composites described herein also resist leaching of copper species in the presence of buffer, and exhibit an order of magnitude higher killing efficiency using 20 times less total metal when compared to tests using soluble Cu2+. Together these data suggest that copper‐based nanoparticle‐coated cotton materials have facile antimicrobial properties in the presence of A. baumannii through a process that may be associated with contact killing, and not simply due to enhanced release of metal ion. The biocompatibility of these copper‐cotton composites toward embryonic fibroblast stem cells in vitro suggests their potential as a new paradigm in metal‐based wound care and combating pathogenic bacterial infections.


  • Direct attachment of DNA to semiconducting surfaces for biosensor applications

    by Nicholas M. Fahrenkopf, Fatemeh Shahedipour-Sandvik, Natalya Tokranova, Magnus Bergkvist, Nathaniel C. Cady


  • Antibiotic‐Loaded PLGA Nanofibers for Wound Healing Applications

    by David A. Soscia, Nurazhani Abdul Raof, Yubing Xie, Nathaniel C. Cady, Anand P. Gadre

    Incorporating antibiotics into biocompatible nanoscale non‐woven fibrous mats could provide utility for wound healing applications and for incorporation into wound dressing materials. In this study, the antibiotic chloramphenicol (Cm) was incorporated into electrospun poly(lactic‐co‐glycolic acid) (PLGA) nanofibers, which were then tested for inhibition of bacterial growth for multiple bacterial species (Escherichia coli, Staphylococcus aureus, Bacillus cereus, Salmonella typhimurium, and Pseudomonas aeruginosa). In addition, the cytotoxicity of Cm‐PLGA nanofibers was examined for two types of mammalian cells including mouse embryonic stem cells and fibroblasts. Electrospun PLGA nanofibers containing Cm were able to reduce bacterial growth on solid agar plates for all species except for P. aeruginosa. In liquid culture, Cm‐loaded nanofibers inhibited growth for E. coli, B. cereus and S. typhimurium by 93% or greater, while P. aeruginosa and S. aureus growth was inhibited by 42% and 56%, respectively. Cm‐loaded nanofibers showed limited cytoxicity on fibroblasts and embryonic stem cells, with viability greater than 96% for all conditions tested. These results suggest that Cm can be successfully incorporated into electrospun nanofibers and that these fibers could be used for wound healing applications with minimal cytotoxicity to the surrounding tissue.


  • Low-power microfluidic electro-hydraulic pump (EHP)

    by Clarissa Lui, Scott Stelick, Nathaniel Cady, Carl Batt

    Low-power electrolysis-based microfluidic pumps utilizing the principle of hydraulics, integrated with microfluidic channels in polydimethylsiloxane (PDMS) substrates, are presented. The electro-hydraulic pumps (EHPs), consisting of electrolytic, hydraulic and fluidic chambers, were investigated using two types of electrodes: stainless steel for larger volumes and annealed gold electrodes for smaller-scale devices. Using a hydraulic fluid chamber and a thin flexible PDMS membrane, this novel prototype successfully separates the reagent fluid from the electrolytic fluid, which is particularly important for biological and chemical applications. The hydraulic advantage of the EHP device arises from the precise control of flow rate by changing the electrolytic pressure generated, independent of the volume of the reagent chamber, mimicking the function of a hydraulic press. Since the reservoirs are pre-filled with reagents and sealed prior to testing, external fluid coupling is minimized. The stainless steel electrode EHPs were manufactured with varying chamber volume ratios (1 : 1 to 1 : 3) as a proof-of-concept, and exhibited flow rates of 1.25 to 30 µl/min with electrolysis-based actuation at 2.5 to 10 VDC. The miniaturized gold electrode EHPs were manufactured with 3 mm diameters and 1 : 1 chamber volume ratios, and produced flow rates of 1.24 to 7.00 µl/min at 2.5 to 10 VAC, with a higher maximum sustained pressure of 343 KPa, suggesting greater device robustness using methods compatible with microfabrication. The proposed technology is low-cost, low-power and disposable, with a high level of reproducibility, allowing for ease of fabrication and integration into existing microfluidic lab-on-a-chip and analysis systems.


  • Open Access

    Nucleic Acid-based Detection of Bacterial Pathogens Using Integrated Microfluidic Platform Systems

    by Clarissa Lui, Nathaniel C. Cady, Carl A. Batt

    The advent of nucleic acid-based pathogen detection methods offers increased sensitivity and specificity over traditional microbiological techniques, driving the development of portable, integrated biosensors. The miniaturization and automation of integrated detection systems presents a significant advantage for rapid, portable field-based testing. In this review, we highlight current developments and directions in nucleic acid-based micro total analysis systems for the detection of bacterial pathogens. Recent progress in the miniaturization of microfluidic processing steps for cell capture, DNA extraction and purification, polymerase chain reaction, and product detection are detailed. Discussions include strategies and challenges for implementation of an integrated portable platform.


  • Quantum Dot Molecular Beacons for DNA Detection

    by Nathaniel C. Cady

    Molecular beacons have become an important fluorescent probe for sequence-specific DNA detection. To improve the sensitivity and robustness of molecular beacon assays, fluorescent semiconductor quantum dots (QDs) are now being used as the fluorescent moiety for molecular beacon synthesis. Multiple linkage strategies can be used for attaching molecular beacon DNA to QDs, and multiple quenchers, including gold particles, can be used for fluorescence quenching. Covalent attachment of QDs to DNA can be achieved through amide linkage, and affinity-based attachment can be achieved with streptavidin-biotin linkage. We have shown that these linkage strategies can be used to successfully create quantum dot molecular beacons that can be used in DNA detection assays with high specificity.


  • Phosphate-dependent DNA Immobilization on Hafnium Oxide for Bio-Sensing Applications

    by Nicholas M Fahrenkopf, Serge Oktyabrsky, Eric Eisenbraun, Magnus Bergkvist, Hua Shi, Nathaniel C Cady


  • Direct Cell Printing With Microfabricated Quill-Pen Cantilevers

    by William F. Hynes, Alison Gracias, Nicholas M. Fahrenkopf, Nurazhani Abdul Raof, Waseem K. Raja, Katherine Lee, Yubing Xie, Magnus Bergkvist, Nathaniel C. Cady

    A novel direct cell printing technique has been developed to control and manipulate the position of cells on solid surfaces. The method utilizes microfabricated polymeric “quill-pen” cantilevers to transfer living cells onto a wide variety of surfaces. In contrast with existing cell deposition methods, such as ink jet or laser ablation methods, the quill-pen approach imparts minimal thermal and shear stress to cells, preserving cell viability and biological functionality. Deposition of both bacterial and mammalian cells into defined patterns has been demonstrated using this method. The size of printed, cell-containing droplets could be controlled by varying the geometry of the quill-pen stylus and by varying printing conditions such as contact time, relative humidity, and surface hydrophobicity. Initial experiments using 10 μm diameter polymer beads demonstrated that the number of beads per droplet could be controlled by varying spot size and particle concentration in the printing solution. Spots could be printed ranging from 20 μm and 100 μm in diameter with approximate volumes ranging from 1-250 pL. We demonstrated deposition of both cells and beads onto a variety of solid surfaces including agarose gel, polystyrene, polyethylene, and glass. Printed cells have also been immobilized on glass and polymer surfaces using biocompatible hydrogel materials (both alginic acid and hyaluronic acid-based matrices) as well as poly-L-lysine. Similar to polymer beads, the number of cells in printed droplets was shown to be dependent upon the size of the droplet, and could be varied by adjusting the concentration of cells present in the printing fluid. As few as one cell per spot could be achieved by adjusting these parameters. The viability and proliferation of printed cells has been evaluated using live optical imaging to observe cell growth and division. Both bacterial cells (Escherichia coli) and mammalian cells were able to divide and proliferate for at least 96 hr post-printing (experiments were discontinued after 96 hr). Live/dead staining was also used to confirm the viability of printed cells. Rat mammary adenocarcinoma MTLn3 cells and mouse embryonic stem cells were also shown to survive the printing process for at least 24 - 96 hr post-printing. These results demonstrate the feasibility of the printing method and its compatibility with a wide range of cell types. It is especially noteworthy that embryonic stem cells could survive the printing process (and proliferate on the printing substrate). This novel printing method has applications for tissue engineering, cell-to-cell signaling studies, and for directly interfacing cells with nanodevices and biosensors.