JKJosef Kröll

Josef Kröll

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Josef Kröll has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of a Sensor-Based Dynamic Ski Deflection Measurement in the Lab and Proof-of-Concept Field Investigation

    by Christoph Thorwartl, Josef Kröll, Andreas Tschepp, Helmut Holzer, Wolfgang Teufl, Thomas Stöggl

    Introduction: Ski deflection is a performance-relevant factor in alpine skiing and the segmental and temporal curvature characteristics (m−1) along the ski have lately received particular attention. Recently, we introduced a PyzoFlex® ski deflection measurement prototype that demonstrated high reliability and validity in a quasi-static setting. The aim of the present work is to test the performance of an enhanced version of the prototype in a dynamic setting both in a skiing-like bending simulation as well as in a field proof-of-concept measurement. Material and methods: A total of twelve sensor foils were implemented on the upper surface of the ski. The ski sensors were calibrated with an empirical curvature model and then deformed on a programmable bending robot with the following program: 20 times at three different deformation velocities (vslow, vmedium, vfast) with (1) central bending, (2) front bending, (3) back bending, (4) edging left, and (5) edging right. For reliability assessment, pairs of bending cycles (cycle 1 vs. cycle 10 and cycle 10 vs. cycle 20) at vslow, vmedium, and vfast and between pairs of velocity (vslow vs. vmedium and vslow vs. vfast) were evaluated by calculating the change in the mean (CIM), coefficient of variation (CV) and intraclass correlation coefficient (ICC 3.1) with a 95% confidence interval. For validity assessment, the calculated segment-wise mean signals were compared with the values that were determined by 36 infrared markers that were attached to the ski using an optoelectrical measuring system (Qualisys). Results: High reliability was found for pairs of bending cycles (CIM −0.69–0.24%, max CV 0.28%, ICC 3.1 > 0.999) and pairs of velocities (max CIM = 3.03%, max CV = 3.05%, ICC 3.1 = 0.997). The criterion validity based on the Pearson correlation coefficient was r = 0.98. The accuracy (systematic bias) and precision (standard deviation), were −0.003 m−1 and 0.047 m−1, respectively. Conclusions: The proof-of-concept field measurement has shown that the prototype is stable, robust, and waterproof and provides characteristic curvature progressions with plausible values. Combined with the high laboratory-based reliability and validity of the PyzoFlex® prototype, this is a potential candidate for smart ski equipment.


  • Open Access

    Curvature Detection with an Optoelectronic Measurement System Using a Self-Made Calibration Profile

    by Christoph Thorwartl, Thomas Stöggl, Wolfgang Teufl, Helmut Holzer, Josef Kröll

    So far, no studies of material deformations (e.g., bending of sports equipment) have been performed to measure the curvature (w″) using an optoelectronic measurement system OMS. To test the accuracy of the w″ measurement with an OMS (Qualisys), a calibration profile which allowed to: (i) differentiates between three w″ (0.13˙ m−1, 0.2 m−1, and 0.4 m−1) and (ii) to explore the influence of the chosen infrared marker distances (50 mm, 110 mm, and 170 mm) was used. The profile was moved three-dimensional at three different mean velocities (vzero = 0 ms−1, vslow = 0.2 ms−1, vfast  = 0.4 ms−1) by an industrial robot. For the accuracy assessment, the average difference between the known w″ of the calibration profile and the detected w″ from the OMS system, the associated standard deviation (SD) and the measuring point with the largest difference compared to the defined w″ (=maximum error) were calculated. It was demonstrated that no valid w″ can be measured at marker distances of 50 mm and only to a limited extent at 110 mm. For the 170 mm marker distance, the average difference (±SD) between defined and detected w″ was less than 1.1 ± 0.1 mm−1 in the static and not greater than −3.8 ± 13.1 mm−1 in the dynamic situations. The maximum error in the static situation was small (4.0 mm−1), while in the dynamic situations there were single interfering peaks causing the maximum error to be larger (−30.2 mm−1 at a known w″ of 0.4 m−1). However, the Qualisys system measures sufficiently accurately to detect curvatures up to 0.13˙ m−1 at a marker distance of 170 mm, but signal fluctuations due to marker overlapping can occur depending on the direction of movement of the robot arm, which have to be taken into account.


  • Open Access

    A Novel Sensor Foil to Measure Ski Deflections: Development and Validation of a Curvature Model

    by Christoph Thorwartl, Josef Kröll, Andreas Tschepp, Philipp Schäffner, Helmut Holzer, Thomas Stöggl

    The ski deflection with the associated temporal and segmental curvature variation can be considered as a performance-relevant factor in alpine skiing. Although some work on recording ski deflection is available, the segmental curvature among the ski and temporal aspects have not yet been made an object of observation. Therefore, the goal of this study was to develop a novel ski demonstrator and to conceptualize and validate an empirical curvature model. Twenty-four PyzoFlex® technology-based sensor foils were attached to the upper surface of an alpine ski. A self-developed instrument simultaneously measuring sixteen sensors was used as a data acquisition device. After calibration with a standardized bending test, using an empirical curvature model, the sensors were applied to analyze the segmental curvature characteristic (m−1) of the ski in a quasi-static bending situation at five different load levels between 100 N and 230 N. The derived curvature data were compared with values obtained from a high-precision laser measurement system. For the reliability assessment, successive pairs of trials were evaluated at different load levels by calculating the change in mean (CIM), the coefficient of variation (CV) and the intraclass correlation coefficient (ICC 3.1) with a 95% confidence interval. A high reliability of CIM −1.41–0.50%, max CV 1.45%, and ICC 3.1 > 0.961 was found for the different load levels. Additionally, the criterion validity based on the Pearson correlation coefficient was R2 = 0.993 and the limits of agreement, expressed by the accuracy (systematic bias) and the precision (SD), was between +9.45 × 10−3 m−1 and −6.78 × 10−3 m−1 for all load levels. The new measuring system offers both good accuracy (1.33 × 10−3 m−1) and high precision (4.14 × 10−3 m−1). However, the results are based on quasi-static ski deformations, which means that a transfer into the field is only allowed to a limited extent since the scope of the curvature model has not yet been definitely determined. The high laboratory-related reliability and validity of our novel ski prototype featuring PyzoFlex® technology make it a potential candidate for on-snow application such as smart skiing equipment.


  • Open Access

    Foot Strike Angle Prediction and Pattern Classification Using LoadsolTM Wearable Sensors: A Comparison of Machine Learning Techniques

    by Stephanie R. Moore, Christina Kranzinger, Julian Fritz, Thomas Stӧggl, Josef Krӧll, Hermann Schwameder

    The foot strike pattern performed during running is an important variable for runners, performance practitioners, and industry specialists. Versatile, wearable sensors may provide foot strike information while encouraging the collection of diverse information during ecological running. The purpose of the current study was to predict foot strike angle and classify foot strike pattern from LoadsolTM wearable pressure insoles using three machine learning techniques (multiple linear regression―MR, conditional inference tree―TREE, and random forest―FRST). Model performance was assessed using three-dimensional kinematics as a ground-truth measure. The prediction-model accuracy was similar for the regression, inference tree, and random forest models (RMSE: MR = 5.16°, TREE = 4.85°, FRST = 3.65°; MAPE: MR = 0.32°, TREE = 0.45°, FRST = 0.33°), though the regression and random forest models boasted lower maximum precision (13.75° and 14.3°, respectively) than the inference tree (19.02°). The classification performance was above 90% for all models (MR = 90.4%, TREE = 93.9%, and FRST = 94.1%). There was an increased tendency to misclassify mid foot strike patterns in all models, which may be improved with the inclusion of more mid foot steps during model training. Ultimately, wearable pressure insoles in combination with simple machine learning techniques can be used to predict and classify a runner’s foot strike with sufficient accuracy.


  • Open Access

    Does enhanced footwear comfort affect oxygen consumption and running biomechanics?

    by Julia Lindorfer, Josef Kröll, Hermann Schwameder

    Comfort as an essential parameter for running footwear is gaining importance in footwear research and development, and has also been proposed to decrease injury rate and improve metabolic demand in the paradigm of the comfort filter. The aims of this study were to determine differences in oxygen consumption and biomechanical variables associated with lower extremity injuries in response to running shoes of differing comfort. Fifteen male runners attended two testing sessions including an incremental lactate threshold test, a comfort assessment and treadmill running trials for the biomechanical and physiological measurements. Statistical analyses were performed on oxygen consumption, spatio‐temporal variables including foot‐ground angle and coupling angle variability of 12 couplings in five stride phases. No decrease in oxygen consumption was found in the most preferred shoe condition. Investigation of potential biomechanical contributors to changes in metabolic demands revealed differences in the stride rate between the most and least preferred condition. In coupling angle variability analyses, only one coupling (ankle dorsiflexion/plantarflexion to knee varus/valgus) yielded a significant difference between conditions in the phase including the touch down. Based on the findings of this study, previous suggestions regarding positive effects of enhanced footwear comfort during running cannot be supported – neither on economy nor on injury prevention perspective. However, a prospective study of lower extremity injury combined with measurements of biomechanical and physiological variables seems to be required for a definite support or contradiction of the comfort filter.


  • Open Access

    A Magnet-Based Timing System to Detect Gate Crossings in Alpine Ski Racing

    by Benedikt Fasel, Jörg Spörri, Josef Kröll, Erich Müller, Kamiar Aminian

    In alpine skiing, intermediate times are usually measured with photocells. However, for practical reasons, the number of intermediate cells is limited to three–four, making a detailed timing analysis difficult. In this paper, we propose and validate a magnet-based timing system allowing for the measurement of intermediate times at each gate. Specially designed magnets were placed at each gate and the athletes wore small magnetometers on their lower back to measure the instantaneous magnetic field. The athlete’s gate crossings caused peaks in the measured signal which could then be related to the precise instants of gate crossings. The system was validated against photocells placed at four gates of a slalom skiing course. Eight athletes skied the course twice and one run per athlete was included in the validation study. The 95% error intervals for gate-to-gate timing and section times were below 0.025 s. Each athlete’s gate-to-gate times were compared to the group’s average gate-to-gate times, revealing small performance differences that would otherwise be difficult to measure with a traditional photocell-based system. The system could be used to identify the effect of tactical choices and athlete specific skiing skills on performance and could allow a more efficient and athlete-specific performance analysis and feedback.


  • How can we prove that a preventive measure in elite sport is effective when the prevalence of the injury (eg, ACL tear in alpine ski racing) is low? A case for surrogate outcomes

    by Josef Kröll, Jörg Spörri, Sophie Elspeth Steenstrup, Hermann Schwameder, Erich Müller, Roald Bahr

    When dealing with small cohorts, as is typical in elite sport, the well-known four-step ‘sequence of prevention’ described by van Mechelen et al 1 (figure 1) potentially represents a vicious circle: When introducing a prevention measure, an otherwise reasonable call for targeting specific subgroups (ie, relevant groups of athletes, injury locations and specific injury causes) may undermine study power, breaking down an already-small baseline cohort into undersized pieces. Consequently, statistical testing becomes impossible. Figure 1 The four-step ‘sequence of prevention’ as described by van Mechelen et al .1 To illustrate the problem we (1) discuss a recently implemented preventive measure in alpine ski racing as an example, (2) highlight the influence of sample size and effect size on study power and the possibility for statistical hypothesis testing and (3) provide a solution to increase study power for comparable injury prevention initiatives in elite sports. In elite alpine ski racing, we recently tested potential preventive measures (eg, ski equipment changes) that target a specific body part (eg, knee/ACL injuries),2 their specific mechanisms (eg, aggressive ski–snow interaction driven by the skiing equipment)3 4 and specific disciplines (eg, different ski alterations in downhill, super-G and giant slalom).5 Based on this research process,6 the International Ski Federation (FIS) introduced new equipment rules for the 2012–2013 season. The effect of these changes was assessed by repeating step 1 …


  • Open Access

    How to Prevent Injuries in Alpine Ski Racing: What Do We Know and Where Do We Go from Here?

    by Jörg Spörri, Josef Kröll, Matthias Gilgien, Erich Müller

    Alpine ski racing is known to be a sport with a high risk of injury and a high proportion of time-loss injuries. In recent years, substantial research efforts with regard to injury epidemiology, injury etiology, potential prevention measures, and measures’ evaluation have been undertaken. Therefore, the aims of this review of the literature were (i) to provide a comprehensive overview of what is known about the aforementioned four steps of injury prevention research in the context of alpine ski racing; and (ii) to derive potential perspectives for future research. In total, 38 injury risk factors were previously reported in literature; however, a direct relation to injury risk was proven for only five factors: insufficient core strength/core strength imbalance, sex (depending on type of injury), high skill level, unfavorable genetic predisposition, and the combination of highly shaped, short and wide skis. Moreover, only one prevention measure (i.e. the combination of less-shaped and longer skis with reduced profile width) has demonstrated a positive impact on injury risk. Thus, current knowledge deficits are mainly related to verifying the evidence of widely discussed injury risk factors and assessing the effectiveness of reasonable prevention ideas. Nevertheless, the existing knowledge should be proactively communicated and systematically implemented by sport federations and sport practitioners.